					                                    SPECIFICATIOS
             ege=com® Macroduct Multi 2 to 5-channel Multi-duct System

Item   Product                                                     Article   Group   N Unit    Total
                                                                                     o price   price
                                                                                     .
1.     Supply or laying of the cable protection 2 to 5-
       channel multi-duct for drawing into cable
       conduits, cable channels or lining other empty
       piping.

       PE-HD multi-duct to DIN 8074 / 8075, which can be
       easily and flexibly folded, suitable for drawing into
       protection pipes, consisting of 2 – 5 cable protection
       pipes with rough or fine inner grooving that runs
       lengthwise or smooth inside without grooving, and the
       strong but very flexible and securely welded PE-HD
       bar connectors of neighbouring pipes.
       Pipes are tightly held together both at one level next to
       each other and also folded together as a block. The
       multi-duct is easy to lay with spacing between
       individual pipes, bars which can be easily separated
       during assembly.

       Pressure resistance 17 bar at 20 °C for 2 h (material
       level QS1

       Pressure resistance 20 bar at 20 °C for 2 h (material
       level RC+);

       Lettering: according to customer specifications or
                 ®
       ege=com Macroduct Multi (dimension)(production
       code) continuous distance measurement

       Delivery: drums, special drums, customer drums

       Connection of lengths of pipe using fittings and
       couplings. Or:

       The cable protection pipes can be welded to
       continuous pipe lengths according to butt welding
       methods or using electrical sleeve welding with
       incorporated heating element.
Item   Product                                                   Article   Group   No.   Unit    Total
                                                                                         price   price
       Laying only by authorised specialist companies
       according to the valid laying guidelines and
       manufacturer’s specifications

       Supplier: Egeplast Procable

       Colour black RAL.

       Laying of the cable protection pipe according to the
       laying guidelines of T-Com, France Telecom,
       Telecom Italia, Belga-Com, current data and TV
       networks and the technical information provided by
       the manufacturer.

       1, 2, 3, 4 or 5 cable protection pipes with outer
       diameter OD 50 x 3.0, internal diameter ID 44 mm;

       1, 2, 3, 4 or 5 cable protection pipes OD 40 x 2.4, ID
       35 mm;

       1, 2, 3, 4 or 5 cable protection pipes OD 32 x 1.9, ID
       28 mm;

       1, 2, 3, 4 or 5 cable protection pipes OD 25 x 1.8, ID
       21 mm;

       Outer diameter of bundled pipes in line with pipe
       composition;

       Delivery presentation: 1,000 m on drums, pipe ends
       closed with end caps;
                       ®
       Make: ege=com Macroduct Multi X (X= 2 to 5) from
       egeplast or equivalent,

2.     Supply or laying of the cable protection 2 to 5-
       channel multi-duct for direct laying in open
       trenches or laying using plough or cut-and-cover.

       PE-HD multi-duct to DIN 8075, suitable for drawing
       into protection piping consisting of 2 – 5 cable
       protection pipes with rough or fine inner grooving that
       runs lengthwise or smooth inside without grooving,
       and the strong but very flexible and securely welded
       PE-HD bar connectors of neighbouring pipes, which
       can be easily and flexibly folded.
Item   Product                                                     Article   Group   No.   Unit    Total
                                                                                           price   price
       Pipes are tightly held together both at one level next to
       each other and also folded together as a block.

       The multi-duct is easy to lay with spacing between
       individual pipes, eminently suited to simple filling of
       spacing between pipes with ground material, with no
       cavity formation, no blistering and no buoying upwards
       in damp areas with ground water or with Düker
       drainage application,

       with holding bars between pipes which can be easily
       separated during assembly without special tools;

       Pressure resistance 17 bar at 20 °C for 2 h (material
       level QS1

       Pressure resistance 20 bar at 20 °C for 2 h (material
       level RC+);

       Lettering: according to customer specifications or
                 ®
       ege=com Macroduct Mono (dimension)(production
       code) continuous distance measurement or

       Colour black RAL.

       Delivery: drums, special drums, customer drums

       Connection of lengths of pipe using fittings and
       couplings. Or:

       The cable protection pipes can be welded to
       continuous pipe lengths according to butt welding
       methods or using electrical sleeve welding with
       incorporated heating element

       Laying only by authorised specialist companies
       according to the valid laying guidelines and
       manufacturer’s specifications

       Supplier: Egeplast Procable

        Laying of the multi-duct according to the laying
        guidelines of T-Com, France Telecom, Telecom
        Italia, Belga-Com, current data and TV networks and
        the technical information provided by the
        manufacturer.
Item   Product                                                    Article   Group   No.   Unit    Total
                                                                                          price   price

       1, 2, 3, 4 or 5 cable protection pipes with outer
       diameter OD 50 x 3.0, internal diameter ID 44 mm;

       1, 2, 3, 4 or 5 cable protection pipes with OD 40 x 2.4,
       ID 35 mm;

       1, 2, 3, 4 or 5 cable protection pipes with OD 32 x 1.9,
       ID 28 mm;

       1, 2, 3, 4 or 5 cable protection pipes with OD 25 x 1.8,
       ID 21 mm;

       Delivery presentation: 1,000 m on drums, pipe ends
       closed with end caps;
                        ®
       Make: ege=com Macroduct Multi X (X= 2 to 5)
       from egeplast or equivalent

				