Docstoc

Presentation - No Slide Title - PowerPoint

Document Sample
Presentation - No Slide Title - PowerPoint Powered By Docstoc
					PEERLESS PINNACLE
       ®            ®
                        Rev2
              PEERLESS PINNACLE
                           ®              ®
                                              Rev2




     Many States and Local Utilities Offer Additional Rebates
Visit www.dsireusa.org/incentives to Find Rebates in Your Area.
PEERLESS PINNACLE
       ®            ®
                        Rev2
                PEERLESS PINNACLE
                               ®                   ®
                                                       Rev2


       Giannoni Stainless Steel Heat Exchanger
                    Mono Block

                                                           Top Vent Outlet
                                                         for Simplified Vent
                                                             Connection


                             At the Heart of All
                         PureFire Heat Exchangers
                        - the Stainless Steel Loop –
                       Highly Resistant to Corrosion

Bottom-Up Burner Connection
Helps Keep Flue Gasses from
 Backing out at Shut-Down
                PEERLESS PINNACLE
                               ®              ®
                                                   Rev2


      Giannoni Stainless Steel Heat Exchanger
                   Mono Block
                      Boiler                  Boiler
                      Return                  Supply
                       (In)                    (Out)

                    Return                                 Supply
                    Sensor                                 Sensor




                                                  Baffle in Manifold
                                                     to Separate
                                                  Supply & Return
                                                        Water



Drain/Purge Valve        Separate Condensate Drain
    (Supplied)         Connections for Heat Exchanger
                            & Vent Connectors
             PEERLESS PINNACLE
                           ®                   ®
                                                   Rev2




    Sleek & Functional Mono Design
                                                            Vent & Air
                               System Return               Connections
                                    (In)
Display
                                                          Service Switch
                               System Supply
                                    (Out)
 Main                                                          Fuel Gas
Control                                                       Connection
                          Blower &
                          Gas Valve                           Front
                                                              Cover
Left Side
 Panel
                          Condensate
                            System


 Removable Front Plastic Cover - Removable Metal Side Panels
   Well-Sealed Cabinet - Prevents Combustion Odors which
                Promotes Healthy Indoor Air
     Top Connections – Fuel, Piping Wiring & Venting
 PEERLESS PINNACLE
              ®                 ®
                                    Rev2


      Duo Block Design
Stainless Steel Heat Exchanger




      Top Vent Outlet Connection

      Bottom-Up Burner Mounting
      Helps Keep Flue Gasses from
       Backing out at Shut-Down

       Duo Design Allows
     Smaller Boiler Footprint
              PEERLESS PINNACLE
                         ®              ®
                                            Rev2



                   Mono Block Design:
          4 Inputs: 50, 80, 110 & 140
                      2 Cabinet Sizes




PureFire 50 & 80                               PureFire 110 & 140
                                      PEERLESS PINNACLE                     ®                                  ®
                                                                                                                    Rev2



                                    Duo Design Concept
                     Cooled Exhaust Gas Outlet
                                                                         Cooled Exhaust Gas Outlet
      Before Second
                                                                                                                          Condensate Deflector
          Exchange                                                                                                          in Upper Chamber
                                                       Condensate
                                                        Deflector
                                                                                                                           Eliminates the Need
                                                                                                                          For 2nd Connection on
    After Second                                                                                                          Condensate Collector,
       Exchange
                                                                                                                              which is Sealed
                                                       Manifold with                                                            with a Cap
                                                        Return Inlet
Return Water                                          &Supply Outlet                                   Manifold Between
                                                                                                         Exchangers
                                         Condensate




Supply Water
                                         Drip




                        Burner




                                          Target Wall
 After First Exchange
                                 Condensate Drain                           Condensate Drain

                                                               Cooled Flue Gas After First Exchange
                   Hot Flue Gas from Burner
                                                               Cooled Flue Gas After Second Exchange
           PEERLESS PINNACLE
                        ®               ®
                                            Rev2



 New Duo PureFire Design Features




 Removable Metal Side Panels & Improved Cabinet Seals
Top Connections for Fuel, Venting & Wiring – 8 Knockouts
        Lower Left Side Brass Piping Connections
                  PEERLESS PINNACLE
                         ®             ®
                                            Rev2


       Duo Heat Exchanger Tappings

Flue Gas Sensor
  (Other Side)

                                           Vent Pressure Switch
         Return
                              Relief            (Front Side)
         Sensor
                              Valve
                                       Baffle in Manifold to Separate
 ⅝” Condensate                            Supply & Return Water
  Connection                 Supply
                             Sensor

         Boiler               Boiler
         Return               Supply
          (In)                 (Out)


                                             Drain/Purge Valve
                                                  (Inside)
       PEERLESS PINNACLE
                ®          ®
                               Rev2

Duo Block Design - Inputs: 210 & 399mbh
            2 Cabinet Sizes
                     PEERLESS PINNACLE        ®                                  ®
                                                                                      Rev2


                 PureFire 210 & 399 Ratings
• 5:1 Turndown Ratio
• Can Be Higher When Approval Agencies Raise Maximum
• Higher Turndown with Large Inputs Are More Reliable
      & Have a Greater Impact on Efficiency
• Vent Length As Much As 200’ Total Equivalent
• Circulators
       PF-210 – Taco 0014 or Grundfos UPS 26-99FC
       PF-399 – Taco1400-20 or Grundfos UP 32-80F

                        Input (MBH)      Heating    Net I=B=R
                                                                                                  Appx Shipping
  Boiler Model                           Capacity    Ratings     AFUE (%)
                                                                                                   Weight (lbs)
                                          (MBH)      (MBH)
                 Minimum       Maximum
  PF-210           42            210      192         167          97.3                               160

                        Input (MBH)      Gross      Net I=B=R
                                                                   Thermal        Combustion      Appx Shipping
  Boiler Model                           Output      Ratings
                                                                Efficiency (%)   Efficiency (%)    Weight (lbs)
                                         (MBH)       (MBH)
                 Minimum       Maximum

  PF-399           80            399      373         324          93.4              95.5             250
       PEERLESS PINNACLE
                   ®            ®
                                    Rev2



Full-Featured & Easy-To-Use Boiler Control
        with Plain English Text Display
          No Need to Memorize Codes
Most Features are Pre-Programmed & Ready-to-go
          PEERLESS PINNACLE
                    ®            ®
                                     Rev2




    New Features Scheduled for Release with
          PF-210 & PF-399 in 2009




    Display                             Main Control



Same Location for Display As Mono Block Design
 New Location for Main Control for Easy Access
         PEERLESS PINNACLE
                       ®                ®
                                            Rev2



All PureFire Boiler Controls Use Fuse Protection
           - Easily Replaceable Fuse -




                                               Main Control



Fuse Size = 5mm x 20mm, 250 Volt, Slow Blow
Available at Radio Shack (Part# 270-1067) 4-Pack - $2.99
   PEERLESS PINNACLE®                  ®
                                           Rev2



      Molded Plastic Jacket
With Tinted Clear Lens for Viewing Control Display
PEERLESS PINNACLE
              ®                  ®
                                     Rev2


EBM-Papst Blowers
 Dungs Gas Valves
   Extensively Field-
   Tested by Peerless
 Patented Whirlwind Technology
    Promotes Better Fuel/Air
  Mixing for Better Combustion




      Various Swirl Plates for
       Different Boiler Sizes
  PEERLESS PINNACLE
                ®                 ®
                                      Rev2


Dungs Gas Valve Operation
      Adjust CO2 ONLY with
       Throttle Screw
      Gas valves are preset
       at factory for fuel type
      Fuel Pressure can be
       measured at Inlet
       Pressure Tap
               PEERLESS PINNACLE
                               ®                  ®
                                                      Rev2


         Worgas Metal Mesh Burners
                 Provide Stable and Reliable Flame




              Igniters & Flame Sensors
Provide Dual Sensing of Burner Flame – Help Prevent Unnecessary Lockouts
  PEERLESS PINNACLE
              ®            ®
                               Rev2

    Molded Plastic Vessels for
Condensate Collection & Neutralizing




                                Optional for PF-210 & 399
      PEERLESS PINNACLE
                  ®            ®
                                   Rev2


Simplified Electrical Connections
Pre-Wired Harnesses & Split Terminal Strips
      PEERLESS PINNACLE
                ®         ®
                              Rev2




     Additional Features




Leveling Legs       Courtesy Outlet
          PEERLESS PINNACLE
                         ®           ®
                                         Rev2




                        Features




                             Knock-out Grommet
Outdoor Sensor                 For Low-Voltage Wires
  For Outdoor Reset            Helps Protect Wires &
(Supplied as Standard           Keep Cabinet Sealed
     Equipment)
         PEERLESS PINNACLE®                  ®
                                                 Rev2


Venting Options: PVC, CPVC & PP (M&G)
 with Stainless Steel, Concentric PVC & PP Termination Options
PEERLESS PINNACLE
        ®             ®
                          Rev2


  Control Display
     Sample Screens
PEERLESS PINNACLE
        ®             ®
                          Rev2


  Control Display
     Sample Screens
                       PEERLESS PINNACLE       ®                           ®
                                                                               Rev2



                             Control Features
                         New or Enhanced in 2009
    Feature                                             Description

Cascade            Multiple boilers operate together in order to satisfy the heating or DHW demand.

                   One hour after a lockout on ignition or flame failure, the PUREFIRE control will
One Hour Retry
                   reinitiate boiler operation.

Restore System     Allows the installer to reset all parameters to the factory defaults if desired. The
Defaults           installer can also save and restore site defaults.


Adjustable Blower This feature allows the installer to increase the blower postpurge to counteract the
Postpurge         effects of high winds or unusual wind currents.


                 This troubleshooting tool captures the flame signal at four increments during the
Flame Signal Log two second flame proving period. This can help installers/service personnel to
                 quickly diagnose problems with flame rectifications.

                   The PUREFIRE control allows service personnel to access the last 15 Blocking
Fault History      Errors and the last 15 Lockout Errors in addition to records of the interval between
                   Errors.
         PEERLESS PINNACLE®                  ®
                                                 Rev2


          New Control Features
     Cascade Firing of Multiple Boilers
• Control up to16 Boilers in One System
• No Extra Controls Required, Only 1 System Sensor
• Automatic Rotation of Boilers (Lead/Lag)
• No Extensive Programming Required
        - Most Options Are Pre-Selected, But Adjustable
• Boilers will be Fired Proportionally with Timed Start and
        Stop for Maximum Efficiency & Longevity
• All PureFire™ Boilers will be Cascade Capable
        - After the Release of the new PF-210 & PF-399
        - Existing PF Boilers Can Be Easily Upgraded
• New Controls will be Compatible with Older Displays &
        Vice Versa
              PEERLESS PINNACLE®                  ®
                                                      Rev2


     Cascade Functions with Multiple Boilers
• The Control on Any Boiler can be the Master Control
• Simple Instructions Explain How to Designate the Master
        Control and All Dependent Controls
• All Sensors and Non-Boiler Pumps are Wired to the Master
• Control & Status of All Boilers Including Resets can be
        Done Through Master
• Each Dependent Boiler Controls Only Its Own Pump
• Boiler Controls are Interconnected in Parallel with only 1 Set of
        Thermostat Wires Between Each Boiler
• Future PC Connections can be made to Any Dependent Control
                       PEERLESS PINNACLE      ®                           ®
                                                                              Rev2



                             Control Features
                                Safety & Efficiency
     Feature                                             Description
                    Activates pumps if temperatures fall below the specified value. If the temperatures
Freeze Protection
                    continue to fall, the boiler is activated.

                This feature is used to prevent short cycling in systems using very small zones. The
Ramp Delay Step
                input rate is gradually increased from 20% to 100% over 2 minutes. When used, this
Modulation
                only effects central heating operation.

Add’l Safety        Allows the installer to choose between a low water cutoff and a flow switch for water
Functions           level safety shutdown.

                 Reduces the firing rate if the vent temperature approaches the maximum limit of the
Vent Temperature
                 vent material. If the vent temperature continues to climb, the PUREFIRE control will
Safety Limit
                 shut down the boiler.

                    If enabled, the PUREFIRE control will display a service notification after an installer
Service
                    defined number of hours or cycles. It can also display a notification based on a date of
Notification
                    the installers choosing.

                    The PUREFIRE boiler will allow the installer to operate the boiler at low power, high
System Test
                    power and ignition input for troubleshooting purposes.
                   PEERLESS PINNACLE       ®                           ®
                                                                           Rev2



                         Control Features
                                Central Heating
    Feature                                           Description

                The PUREFIRE control changes the boiler supply target temperature to compensate
Outdoor Reset   for changes in load due to milder outdoor temperatures. This increases the efficiency
                of the boiler and is more comfortable.


                By choosing the heat distribution type (finned tube baseboard, hydro air, cast iron
System Type
                radiators, cast iron baseboard, low mass radiant or high mass radiant) the installer
Presets
                can automatically select practical boiler design and mild weather temperatures.

Temperature     The temperature boost function increases the boiler supply target to recover more
Boost           quickly from setback conditions.

                The PUREFIRE control will shut down the boilers CH functions if the outdoor
Warm Weather
                temperature is above an installer defined maximum. This prevents the boiler from
Shutdown
                running during warm weather.

                The anti-cycling function prevents rapid on/off cycling of the boiler. This includes an
Anti-Cycling
                override function to be sure that all loads are satisfied.
PEERLESS PINNACLE
       ®            ®
                        Rev2



   Outdoor Reset
                    PEERLESS PINNACLE   ®                           ®
                                                                        Rev2




       Central Heating Mode Choices
CH Mode   Display Text               Description

                                     Call-for-Heat signal from thermostat with user selected boiler
   0      Indoor Thermostat
                                     supply target setpoint temperature. (Factory Default)

          Thermostat and Outdoor     Call-for-Heat signal from thermostat with boiler supply target
   1
          Reset                      temperature calculated using outdoor temperature.

                                     Continuous heat demand with boiler supply target temperature
   2      Full Outdoor Reset
                                     calculated using outdoor temperature.
                                     Continuous heat demand with user selected boiler supply target
   3      Permanent Demand
                                     temperature.
          0-10 V Input to modulate
   4                                 This mode is not available at this time.
          Setpoint
          0-10 V Input to modulate
   5                                 This mode is not available at this time.
          Rate

                                     Call-for-Heat signal from a thermostat with user selected boiler
   6      Hydro-Air Unit             supply target setpoint temperature optimized for hydro-air
                                     heating systems.
                 PEERLESS PINNACLE     ®                         ®
                                                                     Rev2



                       Control Features
                         Domestic Hot Water
    Feature                                      Description


DHW Tank Warm Prevents boiler from ramping up to high power if the DHW demand is only to
Hold          keep the tank warm.




                 The PUREFIRE control provides DHW priority for boiler operation. However, the
Limited DHW
                 control will automatically switch between CH and DHW loads after an installer
Priority
                 determined switch time.




                 If enabled, the DHW heat dump function serves to dump heat from the boiler
DHW Heat Dump
                 system to the DHW tank after a CH demand has ended.
                PEERLESS PINNACLE      ®                            ®
                                                                        Rev2




               DHW Mode Choices

DHW Mode          Display Text                                    Description

   0       No DHW                          No domestic hot water tank is used. (Factory Default)


                                           The domestic hot water tank is equipped with a
   1       DHW store with sensor           temperature sensor. The PUREFIRE control modulates the
                                           boiler firing rate based on tank temperature.




                                           The domestic hot water tank is equipped with a thermostat.
                                           The PUREFIRE control responds to the demand from the
   2       DHW store with thermostat
                                           thermostat and modulates the boiler firing rate targeting the
                                           DHW boiler setpoint
                    PEERLESS PINNACLE      ®                        ®
                                                                        Rev2




                    Pump Mode Choices

Pump
            Display Text                                 Description Detail
Mode



                                The General pump is on when the CH pump runs on CH demand. The
       DHW or CH & DHW
 0                              DHW pump runs on DHW demand. Either the CH or DHW pump runs;
       pump
                                they never run at the same time. (Factory Default)

       General pump with        The General pump is always on when burner is on. A line voltage (120
 1
       3-way valve              VAC) 3-way valve is operated to supply water to the DHW tank.


                                The General pump is always on when the burner is on. The CH pump
       Manifold with pump for
 2                              runs on CH demand. The DHW pump runs on DHW Demand. Either
       DHW
                                the CH or DHW pump runs; they never run at the same time.
       PEERLESS PINNACLE
                   ®             ®
                                     Rev2


    Typical Cast Iron Boiler Piping
Parallel Piping Conversion to Primary/Secondary
    PEERLESS PINNACLE
           ®            ®
                            Rev2



Primary/Secondary Piping
DHW Piped into Primary Loop        Zone
                                   Relay




X
X
     PEERLESS PINNACLE
              ®          ®
                             Rev2



Primary/Secondary Piping
    DHW Piped into Boiler Loop
                                    Zone
                                    Relay




X
X
PEERLESS PINNACLE
       ®            ®
                        Rev2



Low Voltage Wiring
PEERLESS PINNACLE
       ®            ®
                        Rev2



Line Voltage Wiring
   PEERLESS PINNACLE
          ®            ®
                           Rev2



Wiring for PF-210 & PF-399
       PEERLESS PINNACLE
                 ®                         ®
                                               Rev2

Line Voltage Wiring – High Amp Circ Pumps
                      PureFire main control has a max amp draw of 5
                        amps including gas valve & other internal loads.
                     Total amp draw of all operating Circulators must be
                       less than about 4.5 amps.
                      For example the General Circulator + the CH
                        Circulator or the DHW circulator must be less than
                        4.5 amps.
                      If the circulator amp draw is higher than 4.5 amps,
                       it must be isolated using a relay.
                     A RIB2401B relay may be used for circulator motors
                       up to 1 horsepower.
                      The wiring schematic below shows how to wire
                        isolation relays to the circulators.
             PEERLESS PINNACLE®              ®
                                                 Rev2




                     Accessories




System Pipe Sensor                      DHW Sensor
 To Aid in System Mixing             For Optional Control of
For Multiple Boiler Systems           Indirect Water Heater -
                                  Control Tank Temp From Boiler
            PEERLESS PINNACLE®      ®
                                        Rev2




                    Accessories




                                 Stainless Steel Table
Wall Mounting Bracket                   Adjustable Legs
  Now Included with Boiler
   For All Four Sizes:
    50, 80, 110, 140
   PEERLESS PINNACLE
                   ®                   ®
                                           Rev2

  Simple Fuel Conversion - LP & NG
 Conversion Kit Included with Every Boiler
 No Orifices to Install or Remove
 Spelled Out in the Conversion Kit:
 Adjust Throttle Screw WITH CO/CO2 Meter
               PEERLESS PINNACLE
                               ®                 ®
                                                     Rev2


            TESTING EQUIPMENT IS REQUIRED
 Electronic CO/CO2 Combustion Analyzers are CRITICAL for Maintaining
       Safe & Efficient Operation of ANY 90+ Efficiency Equipment
 Allowable Carbon Monoxide (CO) emission levels in Pinnacle flue gases:
       Hi-Fire <100 ppm
       Lo-Fire < 20 ppm
     PEERLESS PINNACLE
              ®          ®
                             Rev2


All PureFire Boilers are Thoroughly
       Tested At the Factory




                        Factory Test
                      Record Sheet Is
                       Included with
                       IOM Manual
    PEERLESS PINNACLE
                   ®               ®
                                       Rev2


    More Control Features
        Maximum Input Limits
            New in 2010
• Limit the Maximum Input on Any Boiler
       for Best Efficiency
• Limits can be on either Central Heating, DHW
       or Both with Their Own Limits
• Ideal for Applications Where DHW Load is
        Greater Than CH Load or Vice-Versa
• Boiler Can be Sized for Future Expansion
       Without Sacrificing Efficiency Now
            PEERLESS PINNACLE
                            ®                  ®
                                                   Rev2



  Optional Boiler Interface Board
                        New in 2010
• Allows boiler(s) to be connected to a Building Management System
(BMS)
• Can be Used with Existing Boiler Control to Receive
       an External 0-10 Volt Signal to
        Control Boiler Setpoint.
• Can be Used to Connect to an External Alarm for Boiler
        Shutdown Through Lockout or Block Error.
• Order as PFA-1 InterFace Board Kit (54271)
    PEERLESS PINNACLE
             ®          ®
                            Rev2



Optional Boiler Interface Board
       PEERLESS PINNACLE
                ®            ®
                                 Rev2


Coming Soon: PC Software &
USB Connection For Control
         PEERLESS PINNACLE
                    ®           ®
                                    Rev2



        Ratings & Designations
• The PureFire™ Name has been Granted
     Trademark Status.
• PF50, PF80, PF110 & PF140 have been
     Approved for Mobil Homes and
     Manufactured Homes.
• PF50, PF80, PF110 & PF140 have been
     Certified to the Strict California
     Air Quality Standards (SCAQMD)
           PEERLESS PINNACLE
                      ®            ®
                                       Rev2



              Selling PureFire
•   Literature, Features and Benefits Sheets
•   Extended Warranties
•   Advertising Support
•   Custom ads available
•   PB Energy Calculator
•   Best Practices Training
PEERLESS PINNACLE
       ®            ®
                        Rev2
             PEERLESS PINNACLE
                             ®                 ®
                                                   Rev2



  PureFire Extended Warranty Program
• Standard Program -1 Yr parts and labor from 31st day after install
   – Free if warranty card is returned
• PUREFIRE Introductory Program - $99 cost (PF50, 80, 110, 140
   & PF210) or $179 (PF399) to Contractor/Dealer for a 5 Year
   Parts and Labor Program - 10 Year program Cost - $279 (PF50,
   80, 110, 140 & PF210) or $432 (PF399).
• Program Administered by CornerStone United, a US/Canadian
   Warranty Administrator


         * Installer MUST Sign Up to be
           Registered Warranty Dealer
         PEERLESS PINNACLE
                   ®         ®
                                 Rev2



PureFire Warranty Form &
 Extended Warranty Form
        PEERLESS PINNACLE
                    ®             ®
                                      Rev2


Parts of Peerless Extended Warranty Dealer Forms
  PEERLESS PINNACLE
              ®            ®
                               Rev2


Peerless Extended Warranty Brochure
              PEERLESS PINNACLE
                              ®                  ®
                                                       Rev2


              Energy Saving Calculator
• Used by Installers to Help Sell High Efficiency to          Homeowners
   by Showing Fuel Savings
• Easy to Use 4-Step procedure with Slide Windows and Most Factors
  Provided. Building Heat Loss & Fuel Type are Needed.
• Handy Size, Attractive and Loaded with Information
• Current Cost: $6 each (Oil Version & Natural Gas/LP Version) or $10
   for both
           PEERLESS PINNACLE
                       ®            ®
                                        Rev2



       AD Program for PureFire
•   Custom ads on IMUS in the morning
•   Trade magazines
•   Local Meetings – Co-Op
•   PureFire PB Trailer for Live Fire Training
•   Trade Shows
•   Local Advertising Opportunities
PEERLESS PINNACLE
       ®            ®
                        Rev2
                 PEERLESS PINNACLE ®                   ®
                                                           Rev2




•   What is EnergyLoan?
                             Financing
•   The EnergyLoan is a special          •   No Home Equity is Required -
    financing program offered by AFC         You can qualify even if you are
    First as a FannieMae Approved            a new homeowner.
    Energy Loan Lender and in            •   "No Payment for 3 Months"
    cooperation with our Approved            Deferred First Payment
    Contractor/Dealers.                      Available
•   EnergyLoan is an unsecured loan      •   No Closing Costs - The
    program with preferential interest       EnergyLoan has no fees of any
    rates and terms designed to make         kind.
    fast and affordable financing from   •   Term of Up to 10 Years with No
    $1,000 to $20,000 available to           Pre-Payment Penalty - Lower
    homeowners for most types of             payments, but the flexibility to
    improvements that improve the            pay extra principal or pay the
    energy efficiency of your home.          loan off early.
                                         •   Rates of 9.99% to 12.99%
                 PEERLESS PINNACLE   ®                     ®
                                                               Rev2



                  Payment Calculator
AMOUNT

                                                                   10 Year
                      3 Year                 5 Year

$2,500                $ 81                   $ 56                  $ 39
$5,000                $ 161                  $ 111                 $ 78
$7,500                $ 242                  $ 167                 $ 116
$10,000               $ 342                  $ 233                 $ 155
$12,500               $ 427                  $ 291                 $ 194
$15,000               $ 513                  $ 349                 $ 233
$17,500               $ 598                  $ 407                 $ 272
$20,000               $ 683                  $ 465                 $ 310
Estimated payment is based on interest rates ranging from 9.99% to 12.99% APR.
    Actual rate and payment depends on customer's credit, term and other factors
PEERLESS PINNACLE
       ®            ®
                        Rev2
 PEERLESS PINNACLE
        ®            ®
                         Rev2




 THE END

THANK YOU

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:180
posted:1/12/2011
language:English
pages:68