									Core Criteria                                                        CECP                                                               ELI                                                                                  ENERGY STAR (proposed)                                                             Vietnamese Procurement Specification (2005)

                                                                                                      CFL must continuously illuminate within 1.5 second of being switched                                                                                                                              CFL must continuously illuminate within 1.5 seconds of being
Starting Time                     For electronic ballast:≤4s;    For magnetic ballast:≤10s                                                                                     Time after switching on until full start (and remain lighted), average of ten samples shall be less than 1.00 second.
                                                                                                      on.                                                                                                                                                                                               switched on

                                                                                                                                                                                                                                            Bare (amalgam),
                                                                                                                                                                                                          Average of 10 samples tested                                  Average of 10 samples tested    The time to 75% of stabilized light output ≤ 100 seconds, or,
Run-up Time                       NA                                                                  NA                                                                       Bare (non-amalgam)                                           covered and outdoor
                                                                                                                                                                                                          shall be less than 1.0 minute                                 shall be less than 3.0 minute   the time to 80% of stabilized light output ≤ 120 seconds
                                                                                                                                                                                                                                            reflectors
                                                                     Initial Luminous Efficacy                                          Initial Luminous Efficacy              Input Power                                                  Initial Luminous Efficacy                                   Input Power                   Initial Luminous Efficacy

                                   Input power(W) Correlated Color Temperature (CCT)                   Input power(W) Correlated Color Temperature (CCT)                       Lamp power < 10                                              50                                                          <15 W:                        ≥ 45

                                                      6500K,5000K           4000K,3500K,3000K,2700K                      6500K,5000K            4000K,3500K,3000K,2700K        10 < Lamp power < 15                                         55                                                          ≥15 W                         ≥ 55
Initial Efficacy(without cover)          ≥ 5 to <9              46                       50                 ≥ 5 to <9              46                         50               15 < Lamp power < 25                                         60
                                        ≥ 9 to <15              54                       58                 ≥ 9 to <15             52                         55               Lamp power > 25                                              65
                                       ≥ 15 to <25              61                       65                ≥ 15 to <25             57                         60
                                     ≥ 25 to < 60               67                       70              ≥ 25 to < 60              62                         65
                                                                                                                                                                               Input Power                                                  Initial Luminous Efficacy                                   N/a
                                                                                                                                                                               Lamp power < 10                                              45
                                                                                                      The mininum initial luminous efficacy of a lamp model with a cover(no
                                  The requirements of minimum initial luminous efficacy of a lamp
Initial Efficacy(with a cover)                                                                        reflect)shall be no less than 85% of the requirements indicated in the   10 < Lamp power < 15                                         50
                                  model with a cover are same as the above table.
                                                                                                      above table.
                                                                                                                                                                               15 < Lamp power < 25                                         55
                                                                                                                                                                               Lamp power > 25                                              60
                                                                                                                                                                               Input Power                                                  Initial Luminous Efficacy                                   N/a
Initial Efficacy (Outdoor                                                                                                                                                      Lamp power < 20                                              33
                                  N/a                                                                 N/a
Reflectors)
                                                                                                                                                                               Lamp power > 20                                              40



                                                                                                                                                                               Average lumen output > 90.0% of initial lumen output @       Average lumen output > 80.0% of initial lumen output @
                                  The lumen maintenance shall be no less than 80% when burned for The luminous flux of the lamp must be ≥ 80% of initial levels at 40% of                                                                                                                               After 2000 hours of operation the luminous flux of 80% sample
Lumen Maintenance                                                                                                                                                              1,000 hours of rated life, with ≤ 2 samples having lumen     40% of rated life, with ≤ 3 samples having lumen output <
                                  2000hrs.                                                        model’s rated lifetime.                                                                                                                                                                               CFLs must be ≥ 80% of initial levels
                                                                                                                                                                               output < 85.0%                                               75.0%



Premature Lamp Failure Rate NA                                                                        NA                                                                       NA                                                                                                                       NA


Lifetime                          Must have a minimum rated lifetime of 6,000 hours.                  Must have a minimum rated lifetime of 6,000 hours.                       Must have a minimum rated lifetime of 6,000 hours.                                                                       Must have a minimum rated lifetime of 6,000 hours.

Power Factor                      The actually power facter shall be ≤0.05 of rated value.            Power factor shall be ≥ 0.5 at maximum power.                            Average of sample must be ≥ 0.5.                                                                                         Power factor shall be ≥ 0.5

                                                                                                      Must comply with IEC 60969 and the color tolerance shall be within       Lamps must be marketed as one of the following: 2700K, 3000K, 3500K, 4100K, 5000K, or 6500K. ≥ 90% of                    The CFLs supplied shall be “daylight” color temperature (5500
Colour Appearance                 The color tolerance shall be within 5SDCM from the target values
                                                                                                      5SDCM from the target values.                                            sample must fall withing 7-step ANSI MacAdam ellipse for that color temperature.                                         K to 6500 K).

                                        Correlated Color Temperature        Color Rendering Index
                                               6500K,5000K                  ≥77
Colour Rendering Index                                                                                Color Rendering Index (CRI) should be at least 80.                       Average of the 10 samples CRI > 80.0, and no more than 2 samples can have a CRI less than 77.0                           Color Rendering Index (CRI) should be at least 80.
                                               4000K,3500K                  ≥79
                                               3000K,2700K                  ≥81
                                                                                                      Lamp and lamp package must comply with any local regulations
Mercury Content                   NA                                                                  regarding disclosure and disposal, including regulations regarding toxic N/a                                                                                                                      N/a
                                                                                                      materials such as mercury.
Core Criteria                                                                 CNIS                                                                               EU Quality Charter                                                                    EST Specification


Starting Time                     For electronic ballast:≤4s;   For magnetic ballast:≤10s                                                                                                                                   Measured after 2 seconds



Run-up Time                       NA                                                                                       The time to 60% of stabilized light output ≤ 60 seconds                                          Measured after 60 seconds

                                                                                     Initial Luminous Efficacy
                                                                Correlated Color Temperature (CCT)                                                                                                                           Class S - which meet the energy labelling requirements for Class A of
                                        Input power(W)
                                                                                                                                                                                                                                              the European Directive 98/11/EC.
                                                                6500K,5000K                      4000K,3500K,3000K,2700K
Initial Efficacy(without cover)             ≥ 5 to <9                         36                                 40        Class A of the EU energy label
                                                                                                                                                                                                                             Class L – which meet the energy labelling requirements for Class B of
                                           ≥ 9 to <15                         44                                 48                                                                                                          the European Directive 98/11/EC. Additionally they shall also meet the
                                          ≥ 15 to <25                         51                                 55                                                                                                          energy labelling requirements of at least 85% of the minimum Class A
                                                                                                                                                                                                                                               requirements of Directive 98/11/EC.
                                          ≥ 25 to < 60                        57                                 60


                                                                                                                                                                                                                             Class P – which are used for decorative effect lighting and which meet
                                                                                                                                                                                                                            the energy labelling requirements for Class B of the European Directive
                                  The requirements of minimum initial luminous efficacy of a lamp model with a cover are
Initial Efficacy(with a cover)                                                                                                                                                                                                  98/11/EC. Additionally they shall also meet the energy labelling
                                  same as the above table.
                                                                                                                                                                                                                             requirements of at least 45% of the minimum Class A requirements of
                                                                                                                                                                                                                                                       Directive 98/11/EC

                                                                                                                                                                                                                            Class R
Initial Efficacy (Outdoor                                                                                                                                                                                                    The efficacy of the centre beam intensity in candelas per watt of rated
                                  N/a
Reflectors)                                                                                                                                                                                                                 power shall not be less than five times that of the incandescent filament
                                                                                                                                                                                                                                              reflector lamp it is claimed to replace.

                                                                                                                                               The lumen maintenance shall               The lumen maintenance
                                                                                                                           Bare Lamps          be no less than 88% when    Covered Lamps shall be no less than 83%
                                                                                                                                               burned for 2000hrs.                       when burned for 2000hrs.           Lumen maintenance measured at 2000 hours life, 5000 hours life, and at
Lumen Maintenance                 The lumen maintenance shall be no less than 80% when burned for 2000hrs.
                                                                                                                                                                                                                            declared median life
                                                                                                                           For both types of
                                                                                                                                                 The lumen maintenance shall be no less than 75% at 100% of rated life.
                                                                                                                           lamps

Premature Lamp Failure Rate NA

                                                                                                                           Must have a minimum rated lifetime of 6,000 hours. If defined as 'Long Life' must have a rated   Lifetime of Type 'S' lamps ≥ 12,000hrs. Lifetime of Type 'L' & 'P' ≥
Lifetime                          Must have a minimum rated lifetime of 6,000 hours.
                                                                                                                           life ≥ 12000 hrs                                                                                 6,000hrs.
Power Factor                      The actually power facter shall be ≤0.05 of rated value.                                 Power factor shall be ≥ 0.55 or ≥ 0.9 for lamps claiming to be high power factor

                                                                                                                                                                                                                            The rated Correlated Colour Temperature (CCT) shall lie between
Colour Appearance                 The color tolerance shall be within 5SDCM from the target values
                                                                                                                                                                                                                            2650K and 2800K.

                                                 Correlated Color Temperature                    Color Rendering Index
                                                          6500K,5000K                            ≥77
Colour Rendering Index                                                                                                     CRI > 80                                                                                         CRI > 80
                                                          4000K,3500K                            ≥79
                                                          3000K,2700K                            ≥81


Mercury Content                   NA




                                  Note: coloured boxes have not been confirmed
                                                                                   Bare Lamps
                                                           Low                                          Medium                                                 High                                Notes

Starting Time                       2.5 seconds                                     1.5 seconds                                          0.5 seconds                                               Since the test method is new, these figures may have to revised after the round-robin

Run-up Time                         180 seconds                                     120 seconds                                          60 seconds                                                Since the test method is new, these figures may have to revised after the round-robin

                                    Input power(W)         Initial Luminous Efficacy Input power(W)          Initial Luminous Efficacy                             Initial Luminous Efficacy       High values are the same as ESTAR for >4040K
                                                                                                                                                             Correlated    Color     Temperature
                                    <15 W:                 ≥ 45                     <15 W:                   ≥ 45                                                                                  Increasing the efficiency of CFLs is probably less important than increasing their reliability at this time
                                                                                                                                            Input power(W)   (CCT)

                                                                                                                                                                                4000K,3500K,30
                                    ≥15 W                  ≥ 55                     ≥15 W                    ≥ 55                                            6500K,5000K
Initial Efficacy(without cover)                                                                                                                                                 00K,2700K
                                                                                                                                              ≥ 5 to <10            46                 50
                                                                                                                                             ≥ 10 to <15            52                 55
                                                                                                                                             ≥ 15 to <25            57                 60
                                                                                                                                             ≥ 25 to < 60           62                 65
Lumen Maintenance (2000 hours)                       80%                                               80%                                      88%                                                High Value based on EU Quality Charter
Premature Lamp Failure Rate (1000
                                             ≤ 15%                                           ≤ 10%                                              ≤ 5%                                               Since this test is performed on 20 samples, these % mean that 3, 2 and 1 lamp is allowed to fail.
hours)
Lifetime                            Min 4000                                        Min 6000                                             Min 8000
Power Factor                                  0.5                                             0.5                                                0.9                                               Possibly the most controversial! Currently very few high power factor products are manufactured

                                                                                                                                                             ≥ 90% of
                                     Lamps must be                                Lamps must be                                Lamps must be                 sample must
                                    marketed as one                              marketed as one of                           marketed as one of             fall withing 7-
                                                       The color tolerance shall                    The color tolerance shall
                                     of the following:                             the following:                               the following:               step ANSI
Colour Appearance                                      be within 5SDCM from                         be within 5SDCM from                                                                           High spec is based on ESTAR
                                     2700K, 3000K,                                2700K, 3000K,                                2700K, 3000K,                 MacAdam
                                                       the target values                            the target values
                                     3500K, 4100K,                                3500K, 4100K,                                3500K, 4100K,                 ellipse for that
                                    5000K, or 6500K.                             5000K, or 6500K.                             5000K, or 6500K.               color
                                                                                                                                                             temperature.

Colour Rendering Index                   CRI > 75                                           CRI > 80                                         CRI > 80
Mercury Content                         5mg/lamp                                         5mg/lamp                                            5mg/lamp                                              EU ROHS

								