									                                                                                      For internal use only:
                                                                        BBP Project #
                                                                        Date of Application Received:




APPLICATION FORM
This application will allow you to tap into rebates to help make your existing building more energy efficient. There are
incentives for energy-efficiency upgrades and energy audits. These rebates could cover up to 50% of your energy
upgrade costs.

The Better Buildings Partnership (BBP) assists building owners and managers to improve their buildings through energy
efficiency measures. The Multifamily Energy Efficiency Rebates (MEER) offer financial incentives to encourage energy
efficiency projects that reduce peak electricity demand (kW) and/or electricity consumption (kWh) in existing
multifamily residential buildings.

To get started, complete the attached Application Form with your plans for energy efficiency upgrades (you should
continually reference the Guidelines document as you go). If you have already completed an energy efficiency upgrade
project, you may still be eligible for rebates if your upgrade started after January 1, 2008.


Please send your completed Application Form and supporting documentation to:

Better Buildings Partnership - MEER
Metro Hall, 2nd Floor, Room 206
55 John Street
Toronto, ON M5V 3C6

If you have any questions, we’re here to help. Just call us at 416-392-1500, email us at applybbp@toronto.ca, or visit us
at toronto.ca/bbp. For buildings located outside the City of Toronto’s 416 area, please contact 1-877-679-MEER (6337).
SECTION 1A BASIC ELIGIBILITY CHECK
BEFORE YOU BEGIN Please ensure you can check the "Yes" box beside all of the following statements to be eligible for a
rebate (see Guidelines for more details):
I am the building’s owner or legally authorized to act for the building’s owner.                                                            YES
My building contains 6 or more Residential Units totalling more than 600 square meters (6,450 square feet) in area.                         YES
More than 50% of my building’s use is comprised of Residential Units.                                                                       YES
My building is located in Ontario and outside the City of Toronto 416 area.                                                                 YES
My building is not owned by an Institution* and is not located on Native reserve land.                                                      YES
All of the measures being applied for will provide electricity savings.                                                                     YES

The number of residential units will not change as a result of the project. This project is not an addition to an existing build.           YES


Calculated Savings Project Eligibility Check:
My building square footage is greater than 2,300 square meters (25,000 square feet).                                                        YES
* Refer to MEER Program Guidelines for Details.

SECTION 1B APPLICATION SUMMARY DETAILS
Choose one of the following options:

        I have commenced a project after January 1, 2008                          I plan to start a project with the following timelines:
        (for Retroactive Applications)
                                                                              Start
        I have completed a prescriptive measures project.                     Finish

Which of the following best describes your reasons for this retrofit project?
        Planned replacement                     Unexpected replacement
        Efficiency upgrade                      Other

Have you received or are you anticipating any other financial incentives for these upgrades through any other rebate
program?

If yes, please provide the names of all agencies providing additional funding and the amount(s):

                 NAME OF FUNDING AGENCY                                       NAME OF PROGRAM                              FUNDING ($)




SECTION 2 CONTACT INFORMATION
Refer to Guidelines to determine role requirements:

LEGAL NAME OF BUILDING OWNER:
(e.g. Corporation Name, Sole Proprietor)
CONTACT NAME:
JOB TITLE:
STREET NUMBER:                                    STREET NAME:
CITY:                                             PROVINCE:                                POSTAL CODE:
TELEPHONE:                                        E-MAIL:




                                                                          2
SITE CONTACT INFORMATION (e.g. Property Manager)
        same as above or:

NAME OF PRIMARY CONTACT:
JOB TITLE:
COMPANY NAME:
STREET NUMBER:                           STREET NAME:
CITY:                                               PROVINCE:                             POSTAL CODE:
TELEPHONE:                                          E-MAIL:
RELATIONSHIP TO BUILDING OWNER/APPLICANT

CONSULTANT/CONTRACTOR
to be contacted for technical details (if applicable), see Guidelines for more details.

COMPANY:
CONTACT NAME:                                                                        JOB TITLE:
STREET NUMBER:                           STREET NAME:
CITY:                                               PROVINCE:                             POSTAL CODE:
TELEPHONE:                                          E-MAIL:

Check ONE for Primary Contact
             BUILDING OWNER
             SITE CONTACT
             CONSULTANT / CONTRACTOR

OTHER INFORMATION                     How did you hear about these rebates?
                                      Check all that apply

        In the news                 Advertising                 Conference / trade show                      Referral
        Web                         Association                 Local utility                                Manufacturer/contractor
        Direct mailer               Consultant                  Other


SECTION 2A ABOUT THE BUILDING
BUILDING NAME (IF APPLICABLE):
STREET NUMBER:                           STREET NAME:
CITY:                                               PROVINCE:                             POSTAL CODE:
OWNERSHIP:              PRIVATELY OWNED                                   SOCIAL AND ASSISTED HOUSING
                            Corporate Owner                                     Municipal Housing Authority
                            Condominium Corporation                             Provincial or Federal Government
                            Other                                               Co-operative
                                                                                Off-reserve Native Housing
                                                                                Shelter
                                                                                Religious Organization (Residence)
                                                                                Other non-profit
                                                                                Other




                                                                     3
   BUILDING USE (select the one that applies)
         Multi-unit residential building (MURB)                                    Mixed (at least 50% of the building's floor space must be
                                                                                   residential)

   TOTAL BUILDING FLOOR AREA                                                       m2           Sq.ft     NUMBER OF RESIDENTIAL UNITS

   AGE (Years)                                                                                            NUMBER OF COMMERCIAL UNITS

   FLOORS

   THIS BUILDING INCLUDES THE FOLLOWING:
       Pool (indoor or outdoor)                                           Parking garage                     Outdoor parking lot
       Gym/fitness room                                                   Event room                         Laundry room
       Elevators                                                          Other


SECTION 2B                  BUILDING SYSTEMS AND EQUIPMENT
                            Check all that apply

   BUILDING HEATING FUEL TYPE(S)                                 Electricity                 Gas                    Oil
   WATER-HEATER FUEL TYPE(S)                                     Electricity                 Gas
   UTILITIES PAID BY RESIDENTS                                   Electricity                 Gas
   AIR-CONDITIONING TYPE(S)                                      None                        Chiller
                                                                 Rooftop unit                In-suite units (window/through-the-wall)


SECTION 3                   APPLICATION SUMMARY
 This section is to be filled out once you have completed Schedules A and/or B. Please move forward and return to this section later.

       I am interested in providing energy efficiency information to the residents in my building.


                                                              kW SAVINGS                kWh SAVINGS
                                                                                                               PROJECT REBATE             PROJECT COST
                                                               SUBTOTAL                  SUBTOTAL

SCHEDULE A Prescriptive measures rebate                                                                              $0.00


SCHEDULE B Calculated Savings measures rebate                      0.00                       0.00                   $0.00


PROJECT SUBTOTALS                                                  0.00                       0.00                   $0.00                     $0.00


                                                           TOTAL NUMBER OF
                                                                                             REBATE             AUDIT REBATE
                                                           RESIDENTIAL UNITS                                                                AUDIT COST
                                                                     A                          B                    AxB
ENERGY AUDIT SUBTOTALS (Refer to Energy Audit
                                                                                           $35 per unit              $0.00
Guidelines for eligibility)


                                                                                                              MAXIMUM REBATE            TOTAL PROJECT COST

TOTALS (Add Project and Energy Audit Subtotals)                                                                      $0.00                     $0.00


Note: Incentive Payments are capped at 40% of Total Project Costs.




                                                                            4
SUPPORTING DOCUMENTS All applicants must attach the following:
        PHOTO REQUIREMENTS Recent photos of equipment related to each Calculated Savings measure listed, as per the photo
        documentation requirements outlined. This includes photos of both the original and new equipment.
        INVOICES Invoices supporting the Project Cost numbers used in each Schedule. Each invoice clearly references the measure listed and
        meets requirements outlined. This includes equipment invoices indicating model number, cost and quantities, labour and materials,
        and written confirmation of payment. If your project is not complete, you may submit these at a later date.

        EQUIPMENT DOCUMENTATION A copy of manufacturer’s specifications literature (specification sheets) for each measure equipment
        described in Schedule A and/or B.
        ENERGY AUDIT If applying for the energy audit rebate, attach copies of the energy audit report and audit invoice. Ensure at least one
        measure recommended by the report is implemented as part of Schedule A or B.

If you have installed a new non-electric chiller and/or ground source heat pump, you must also include
the following:
        COOLING LOAD CALCULATIONS
        INSTALLATION by a Canadian GeoExchange Coalition (CGC)-qualified firm (required for ground-source heat pumps only)

If you have completed any Calculated Savings Measures, you must also attach the following:
        ELECTRICITY-USE CALCULATIONS Calculations (handwritten, spreadsheets or modelling software) showing how the kW and kWh
        electricity numbers in Columns A, B, C and D of the Calculated Savings Measures Worksheet were reached.
        REFERENCED VALUES All assumptions, manufacturer’s values and industry standards used in calculations. Calculation formulas used
        are referenced.
  EXISTING EQUIPMENT/SYSTEM For each Calculated Savings measure, briefly describe existing equipment, including type, number of units,
  building estimated age, purpose and area affected (e.g., floors 2-7, parking garage, etc.)




  NEW OR PROPOSED EQUIPMENT/SYSTEM For each Calculated Savings measure, briefly describe the new equipment, including
  proposed/actual make and model numbers.




  CERTIFICATION STATEMENT

  I certify the following: All information in this Application is true and complete. I am authorized to enter into this Application. I have
  reviewed and I agree to the terms and conditions as set forth in this Application package (including the Project Application, Guidelines and
  Terms of Agreement).




        Company name                                                                               Signature




        Name                                                Title                                  Date




                                                                      5
SCHEDULE A PRESCRIPTIVE MEASURES WORKSHEET
Provide information for each prescriptive measure* in your project. Please see Section 3-Supporting Documents on page 5 for a list of additional documentation required for attachment.
* A measure refers to a specific energy-efficiency upgrade. There are two measure categories: prescriptive and custom.

                                                                                                           LIGHTING
                                                                                                                                      Item Count for    Item Count for    Item Count for
            NON-DIMMABLE SELF-BALLASTED                                                                                                                                                        Rebate        Total Rebate   Total Item
                                                                                     Model Number                 Manufacturer         In-suite Area    Common Area         Other Area
         COMPACT FLUORESCENT LIGHT BULBS (CFL)                                                                                                                                                   D           (A+B+C) x D      Count
                                                                                                                                             A                B                 C
Screw-in and GU24 base CFL                 Screw-in and GU24 all sizes <40
                                                                                                                                                                                             $1 per lamp
                                           watts
PAR CFLs - to be used in indoor lighting   11 watts of less PAR CFL                                                                                                                          $4 per lamp
applications
                                           12-20 watts PAR CFL                                                                                                                               $4 per lamp
                                           >20 watts PAR CFL                                                                                                                                 $4 per lamp

                                                                                                                                      Item Count For Item Count For      Item Count For
                                                                                                                                                                                               Rebate        Total Rebate   Total Item
    PIN-SOCKET CFL - DIMMABLE AND NON-DIMMABLE                                       Model Number                 Manufacturer          In-Suite Area Common Area          Other Area
                                                                                                                                                                                                 D           (A+B+C) X D      Count
                                                                                                                                              A            B                   C
2-Pin-socket lamps shall have the          Up to 14 Watts, hard wired,
following efficacy:                        fixture and bulb
● Up to 14 Watts – minimum efficacy        14-26 Watts, hard wired,
of 45 initial Lumens/Watt                                                                                                                                                                  $25 per fixture
                                           fixture and bulb
● 15 to 40 Watts – minimum efficacy of     26-39 Watts, hard wired,
60 initial Lumens/Watt                     fixture and bulb
4-Pin-socket lamps shall have the          Up to 14 Watts, hard wired,
following efficacy:                        fixture and bulb
● Up to 14 Watts – minimum efficacy        14-26 Watts, hard wired,
                                                                                                                                                                                           $25 per fixture
of 45 initial Lumens/Watt                  fixture and bulb
● 15 to 40 Watts – minimum efficacy of     26-39 Watts, hard wired,
60 initial Lumens/Watt                     fixture and bulb

                                                                                                                                      Item Count for    Item Count for    Item Count for
                                                                                                                                                                                               Rebate        Total Rebate   Total Item
                   DIMMABLE CFL - ALL STYLES                                         Model Number                 Manufacturer         In-suite Area    Common Area         Other Area
                                                                                                                                                                                                 D           (A+B+C) x D      Count
                                                                                                                                             A                B                 C
Dimmable CFLs                              Up to 16 Watts dimmable CFL
for the replacement of incandescent
bulbs.                                     17 - 20 Watts dimmable CFL                                                                                                                        $6 per lamp
                                           >21 Watts dimmable CFL


Note: EnergyStar-qualified CFL products are available in a number of formats and styles. EnergyStar-certified CFL products meet the minimum EnergyStar specifications for energy performance and other criteria.
For more information please visit: http://oee.nrcan.gc.ca/residential/energystar-portal.cfm All CFL products must be legal for sale in Ontario and must meet all applicable code and safety requirements (CSA, cUL, etc.)




                                                                                                                   6
                                                                                                              LIGHTING
                                                                                                                                         Item Count for    Item Count for    Item Count for
                                                                                      Model Numbers                  Manufacturer                                                                  Rebate        Total Rebate    Total Item
           STANDARD-PERFORMANCE T-8 FIXTURES                                           Lamp/Ballast                  Lamp/Ballast
                                                                                                                                          In-suite Area    Common Area         Other Area
                                                                                                                                                                                                     D           (A+B+C) x D       Count
                                                                                                                                                A                B                 C
New or Retrofit Fixtures                   Single-lamp standard T-8
                                                                                                                                                                                                $12 / fixture
Re-lamp and re-ballast or new fixtures     fixtures
with standard performance T8 lamps and     2-lamp standard T-8 fixtures                                                                                                                         $14 / fixture
electronic ballasts. Lamps must be 4’ to
8’ in length. Up to four lamps per         3-lamp standard T-8 fixtures                                                                                                                         $16 / fixture
fixture.
                                           4-lamp standard T-8 fixtures                                                                                                                         $18 / fixture

Note: The rebate for Standard Performance T-8 and Reduced Wattage and High Performance T-8 fixtures applies only to the replacement of T12 lamps and ballast with T8 lamps using electronic ballasts.
Replacements of T12 lamps to T8 lamps without installation of electronic ballast(s) are not eligible. It is the Applicant’s responsibility to confirm that light levels of the energy efficient design meet the minimum regulatory
requirements and the suggested maximum levels for the proposed use of the space. All products must be legal for sale in Ontario and meet applicable code and safety requirements (CSA, cUL, etc.).

                                                                                                                                         Item Count for    Item Count for    Item Count for
                   REDUCED WATTAGE AND                                                Model Numbers                  Manufacturer                                                                  Rebate        Total Rebate    Total Item
                                                                                                                                          In-suite Area    Common Area         Other Area
               HIGH PERFORMANCE T-8 FIXTURES                                           Lamp/Ballast                  Lamp/Ballast                                                                    D           (A+B+C) x D       Count
                                                                                                                                                A                B                 C
New or Retrofit Fixtures                        Single-lamp high
                                                                                                                                                                                                $15 / fixture
Re-lamp and re-ballast or new fixtures with     performance T-8 fixtures
high-performance T-8 lamps and electronic       2-lamp high performance
ballasts. Up to four lamps per fixture. T-8                                                                                                                                                     $17 / fixture
                                                T-8 fixtures
lamps and electronic ballasts must comply
                                                3-lamp high performance
with Consortium for Energy Efficiency (CEE)                                                                                                                                                     $19 / fixture
                                                T-8 fixtures
qualifying list. Visit: http://www.cee1.org.
                                                4-lamp high performance
                                                                                                                                                                                                $21 / fixture
                                                T-8 fixtures

Note: The rebate for Standard Performance T-8 and Reduced Wattage and High Performance T-8 fixtures applies only to the replacement of T12 lamps and ballast with T8 lamps using electronic ballasts.
Replacements of T12 lamps to T8 lamps without installation of electronic ballast(s) are not eligible. It is the Applicant’s responsibility to confirm that light levels of the energy efficient design meet the minimum regulatory
requirements and the suggested maximum levels for the proposed use of the space. All products must be legal for sale in Ontario and meet applicable code and safety requirements (CSA, cUL, etc.).

                                                                                                                                         Item Count for    Item Count for    Item Count for
                    STANDARD-PERFORMANCE                                              Model Numbers                  Manufacturer                                                                  Rebate        Total Rebate    Total Item
                                                                                                                                          In-suite Area    Common Area         Other Area
                    MEDIUM BAY T-8 FIXTURES                                            Lamp/Ballast                  Lamp/Ballast                                                                    D           (A+B+C) x D       Count
                                                                                                                                                A                B                 C
New Fixtures Only                               4-lamp standard T-8
                                                                                                                                                                                                $90 / fixture
Standard T8 lamps and electronic ballasts for   fixtures
use in medium bay applications (those
                                                6-lamp standard T-8
where the bottom of the luminaire is                                                                                                                                                            $100 / fixture
                                                fixtures
between 16' to 25' above the floor). Up to 8
lamps per fixture. For replacement of high-     8-lamp standard T-8
                                                                                                                                                                                                $125 / fixture
intensity-discharge (HID) luminaires.           fixtures

NOTE: The rebate for Medium Bay T-8 fixtures (both Standard- and High-Performance) applies only to the replacement of HID lighting with T-8 fixtures with electronic ballasts mounted at a height of no less than 16' above the
floor. It is the Applicant’s responsibility to confirm that light levels of the energy-efficient design meet the minimum regulatory requirements and the suggested maximum levels for the proposed use of the space. All products
must be legal for sale in Ontario and meet applicable code and safety requirements (CSA, cUL, etc.).




                                                                                                                     7
                                                                                                           LIGHTING
                                                                                                                                      Item Count for   Item Count for    Item Count for
                     HIGH-PERFORMANCE                                               Model Numbers                 Manufacturer                                                                Rebate        Total Rebate   Total Item
                                                                                                                                       In-suite Area   Common Area         Other Area
                   MEDIUM BAY T-8 FIXTURES                                           Lamp/Ballast                 Lamp/Ballast                                                                  D           (A+B+C) x D      Count
                                                                                                                                             A               B                 C
New Fixtures Only                                           4-lamp High
High-performance T8 lamps and electronic ballasts for       Perf.
                                                                                                                                                                                           $100 / fixture
use in medium-bay applications (those where the             T-8 fixtures per
bottom of the luminaire is between 16' and 25' above        250W MH
the floor). Up to 8 lamps per fixture. For replacement of   6-lamp High
high-intensity-discharge (HID) luminaires. Lamps and        Perf.
                                                                                                                                                                                           $120 / fixture
ballasts must be on the Consortium for Energy Efficiency    T-8 fixtures per
(CEE) High-Performance qualifying list. Visit               400W MH
http://www.cee1.org                                         8-lamp High
                                                            Perf.
                                                                                                                                                                                           $150 / fixture
                                                            T-8 fixtures per
                                                            400W MH
NOTE: The rebate for Medium-Bay T-8 fixtures (both Standard- and High-Performance) applies only to the replacement of HID lighting with T-8 fixtures with electronic ballasts mounted at a height of no less than 16' above the
floor. It is the Applicant’s responsibility to confirm that light levels of the energy-efficient design meet the minimum regulatory requirements and the suggested maximum levels for the proposed use of the space. All products
must be legal for sale in Ontario and meet applicable code and safety requirements (CSA, cUL, etc.).
                                                                                                                                      Item Count for   Item Count for    Item Count for
                                                                                    Model Numbers                 Manufacturer                                                                Rebate        Total Rebate   Total Item
                            T-5 FIXTURES                                             Lamp/Ballast                 Lamp/Ballast
                                                                                                                                       In-suite Area   Common Area         Other Area
                                                                                                                                                                                                D           (A+B+C) x D      Count
                                                                                                                                             A               B                 C
                                                T-5 fixtures with 1, 2 or 3
                                                lamps and 1 electronic                                                                                                                     $105 / fixture
New or Retrofit Fixtures.
                                                ballast
Fixtures with standard T5 ballast and lamps
                                                HO T-5 fixtures with 1 or 2
or high-output ballast and lamps.
                                                lamps and 1 electronic                                                                                                                     $105 / fixture
                                                ballast

                                                                                                                                      Item Count for   Item Count for    Item Count for
                                                                                    Model Numbers                 Manufacturer                                                                Rebate        Total Rebate   Total Item
            T-5 MEDIUM- AND HIGH-BAY FIXTURES                                        Lamp/Ballast                 Lamp/Ballast
                                                                                                                                       In-suite Area   Common Area         Other Area
                                                                                                                                                                                                D           (A+B+C) x D      Count
                                                                                                                                             A               B                 C
New Fixtures                                    4-lampT-5 fixtures                                                                                                                         $105 / fixture
Standard T5 ballast and lamps or high-
output ballast and lamps. Medium-bay            6-lampT-5 fixtures                                                                                                                         $105 / fixture
applications include luminaires that are 16'    8-lampT-5 fixtures
to 25' above the floor. High bay applications                                                                                                                                              $105 / fixture
include luminaires that are higher than 25'     10-lampT-5 fixtures                                                                                                                        $105 / fixture
above the floor.
                                                12-lampT-5 fixtures                                                                                                                        $105 / fixture




                                                                                                                  8
                                                                                                LIGHTING
                                                                                                                  Item Count for   Item Count for   Item Count for
                                                                                Model Numbers      Manufacturer                                                         Rebate        Total Rebate   Total Item
              INFRARED COATED HALOGEN LAMPS                                      Lamp/Ballast      Lamp/Ballast
                                                                                                                   In-suite Area   Common Area        Other Area
                                                                                                                                                                          D           (A+B+C) x D      Count
                                                                                                                         A               B                C
Infrared coated Halogen Lamps                      IR coated MR16 lamp
MR16, PAR30 or PAR38 infrared coated               all sizes < 25 Watts
                                                                                                                                                                     $3 per lamp
halogen are eligible for replacement of            IR coated MR16 lamp
standard halogen or incandescent lamps.            all sizes 26 - 35 Watts
                                                   IR coated PAR lamp
                                                                                                                                                                     $5 per lamp
                                                   48 Watts or less
                                                   IR coated PAR lamp
                                                                                                                                                                     $5 per lamp
                                                   100 Watts

                                                                                                                  Item Count for   Item Count for   Item Count for
                                                                                Model Numbers      Manufacturer                                                         Rebate        Total Rebate   Total Item
             PULSE-START CERAMIC METAL HALIDE                                    Lamp/Ballast      Lamp/Ballast
                                                                                                                   In-suite Area   Common Area        Other Area
                                                                                                                                                                          D           (A+B+C) x D      Count
                                                                                                                         A               B                C
New or Retrofit Fixtures                        320 Watts ceramic
Re-lamp and re-ballast or new lamps and ballast pulse-start                                                                                                          $143 / fixture
combination meeting ANSI #M154.

                                                                                                                  Item Count for   Item Count for   Item Count for
                                                                                Model Numbers      Manufacturer                                                         Rebate        Total Rebate   Total Item
           SELF-BALLASTED CERAMIC METAL HALIDE                                   Lamp/Ballast      Lamp/Ballast
                                                                                                                   In-suite Area   Common Area        Other Area
                                                                                                                                                                          D           (A+B+C) x D      Count
                                                                                                                         A               B                C
Self-ballasted PAR Ceramic Metal Halide lamps <30 Watts PAR Ceramic
are eligible for direct replacement of a 50- to Metal Halide                                                                                                          $30 / lamp
120- Watt Halogen Lamp

                                                                                                                  Item Count for   Item Count for   Item Count for
                                                                                                                                                                        Rebate        Total Rebate   Total Item
                   LOWER WATTAGE HID LAMPS                                      Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                          D           (A+B+C) x D      Count
                                                                                                                         A               B                C
Metal Halide Retrofit Lamps                            150 Watts Metal Halide
                                                                                                                                                                       $6 / lamp
Eligible lamps shall be used for the direct            lamp
replacement of 175-Watt and 400-Watt metal             360 Watts Metal Halide
halide lamps.                                                                                                                                                          $6 / lamp
                                                       lamp
High Pressure Sodium Retrofit Lamps Eligible    225 Watts
lamps shall be used for the direct replacement High-Pressure Sodium
                                                                                                                                                                       $4 / lamp
of 250-Watt metal halide lamps. Must be used in lamp
an indoor lighting application.

                                                                                                                  Item Count for   Item Count for   Item Count for
                       ELECTRONIC BALLASTS                                                                                                                              Rebate        Total Rebate   Total Item
                                                                                Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                     FOR METAL HALIDE LAMPS                                                                                                                               D           (A+B+C) x D      Count
                                                                                                                         A               B                C
New or retrofit fixtures                           <200 Watts Metal Halide
                                                                                                                                                                     $15 / ballast
Pulse-start electronic ballasts are eligible for   electronic ballast
replacement of magnetic metal halide               250 - 360 Watts Metal
                                                                                                                                                                     $30 / ballast
ballasts. Must be used for indoor lighting         Halide electronic ballast
applications.                                      400 Watts Metal Halide
                                                                                                                                                                     $40 / ballast
                                                   electronic ballast




                                                                                                   9
                                                                                            LIGHTING
                                                                                                              Item Count for   Item Count for   Item Count for
                  ELECTRONIC BALLASTS FOR                                   Model Numbers      Manufacturer                                                         Rebate       Total Rebate   Total Item
                                                                                                               In-suite Area   Common Area        Other Area
                HIGH-PRESSURE SODIUM LAMPS                                   Lamp/Ballast      Lamp/Ballast                                                           D          (A+B+C) x D      Count
                                                                                                                     A               B                C
                                             <200 Watts HPS electronic
                                                                                                                                                                 $10 / ballast
                                             ballast
                                             250 Watts HPS electronic
New or retrofit fixtures                                                                                                                                         $12 / ballast
                                             ballast
Pulse-start electronic ballasts are eligible
                                             400 Watts HPS electronic
for the replacement of magnetic high                                                                                                                             $15 / ballast
                                             ballast
pressure sodium ballasts. All must be
                                             600 Watts HPS electronic
used for indoor lighting applications.                                                                                                                           $20 / ballast
                                             ballast
                                             1000 Watts HPS electronic
                                                                                                                                                                 $25 / ballast
                                             ballast

                                                                                                              Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate       Total Rebate   Total Item
     LIGHTING OCCUPANCY SENSORS (Not for In-Suite)                          Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D          (A+B+C) x D      Count
                                                                                                                     A               B                C
Principle of operation shall be passive         Switch plate mounted
infrared, ultrasonic or a combination only.     occupancy sensor                                                                                                  $150 / unit
Commercial grade sensors only. Minimum
controlled load 300 Watts per sensor.           Ceiling mounted occupancy
Prorating of rebate amounts is permitted for    sensor                                                                                                            $150 / unit
controlled loads of less than 300 Watts per
sensor.
                                                                                                              Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate       Total Rebate   Total Item
                               EXIT SIGNS                                   Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D          (A+B+C) x D      Count
                                                                                                                     A               B                C
Signs that are 5 watts or less, including LED
retrofit kits, replacement fixtures and
                                                5 Watts or less                                                                                                   $25 / sign
photoluminescent signs with no
supplemental lighting are eligible.

                                                                                                              Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate       Total Rebate   Total Item
           REFRIGERATED DISPLAY LED STRIP LIGHT                             Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D          (A+B+C) x D      Count
                                                                                                                     A               B                C
Refrigerated display LED lighting. Eligible
units shall be 29 Watts or less, 48" to 70"                                                                                                                      $175 per LED
                                                29 Watts or less
LED strips for use in refrigerated display                                                                                                                         strip light
cases.




                                                                                              10
                                                                    HEATING, VENTILATION AND AIR-CONDITIONING (HVAC)
                                                                                                                                 Item Count for     Item Count for     Item Count for
                                                                                                                                                                                            Rebate        Total Rebate   Total Item
              IN-SUITE TEMPERATURE CONTROLS                                      Model Number                Manufacturer         In-suite Area     Common Area          Other Area
                                                                                                                                                                                              D           (A+B+C) x D      Count
                                                                                                                                        A                 B                  C
In-Suite Temperature Controls                                                                                                                                                            $12/thermostat
                                                      For electric space                                                                                                                     and/or
In-suite measures that reduce space-heating and/or                                                                                                       N/A                N/A
                                                      heating                                                                                                                              occupancy
space-cooling energy use during unoccupied periods.
Eligible measures include programmable                                                                                                                                                       sensor
thermostats and/or occupancy sensors linked to        For electric space
                                                                                                                                                         N/A                N/A
thermostats. A programmable thermostat must           cooling                                                                                                                            $25/thermostat
allow for programming both unoccupied/occupied                                                                                                                                               and/or
setpoints and occupied/unoccupied time periods.                                                                                                                                            occupancy
Occupancy sensors must permit the thermostat to       For electric space                                                                                                                     sensor
                                                                                                                                                         N/A                N/A
switch between an occupied and unoccupied set         heating and cooling
points.

                                                                                                                                                                       Item Count for
                                                                                                                                                       Fan Size                             Rebate        Total Rebate   Total Item
           ECM MOTOR FOR FORCED AIR FURNACE                                      Model Number                         Manufacturer
                                                                                                                                                         (HP)
                                                                                                                                                                         Other Area
                                                                                                                                                                                              D              CxD           Count
                                                                                                                                                                             C
                                                                                                                                                                                         $125 / furnace
Electronically Commutated Motor (ECM) for forced air furnaces.                                                                                                                             with ECM
                                                                                                                                                                                            blower

                                                                                                                                                                        Total Cooling
                                                                                                                                                                       Capacity (Tons)      Rebate        Total Rebate   Total Item
                 GROUND SOURCE HEAT PUMP                                                  Model Number                                     Manufacturer
                                                                                                                                                                                              D              CxD           Count
                                                                                                                                                                              C

Ground-Source Heat Pump
                                            Minimum Cooling COP
System must be installed by a Canadian
                                            (coefficient of                                                                                                                                $250 / ton
GeoExchange Coalition (CGC) qualified firm.
                                            performance) of 3.5
Visit: http://www.geo-exchange.ca

    Replacement Reason                      Ground Heat Exchanger Type                                                        Total facility conditioned area (m2)
            Efficiency Upgrade                    Vertical                  Open-loop           Total facility estimated cooling load (Latent and Sensible) in Tons
                                                                                                                      Total facility estimated cooling run hours
              Equipment Failure                       Horizontal            Closed-loop                                 Total facility estimated latent cooling load

                                                                                                                                                                        Total Cooling
                                                                                                                                                                       Capacity (Tons)      Rebate        Total Rebate   Total Item
                     NON-ELECTRIC CHILLERS                                                Model Number                                     Manufacturer
                                                                                                                                                                                              D              CxD           Count
                                                                                                                                                                              C

Chiller (Engine Driven or Absorption)       Minimum COP of 1.0                                                                                                                             $250 / ton
                                                                                                                                                               2
    Replacement Reason                      Fuel Type                                                                        Total facility conditioned area (m )
              Efficiency Upgrade                      Natural Gas                               Total facility estimated cooling load (Latent and Sensible) in Tons
              Equipment Failure                       Oil                                                                Total facility estimated cooling run hours
                                                      Other                                                            Total facility estimated latent cooling load




                                                                                                            11
                                                                              HOT WATER SERVICE
                                                                                                                                                       Total Capacity
          NON-ELECTRIC CENTRAL INSTANTANEOUS                                                                                                                                Rebate       Total Rebate   Total Item
                                                                             Model Number                                 Manufacturer                   (MBtu/h)
               SERVICE HOT WATER HEATER                                                                                                                                       D             CxD           Count
                                                                                                                                                              C
Non-Electric Tankless / instantaneous service Replaces electric storage
water heater with electric ignition and an EF tank water heaters                                                                                                         $2 per MBtu/h
of 0.8 or greater
     Replacement Reason                       Fuel Type
               Efficiency Upgrade                     Natural Gas                                              Total facility conditioned area (m2)

              Equipment Failure                       Oil                                   Total facility estimated daily hot water use (in litres)

                                                      Other                                 Total facility estimated annual hot water use (in m3)

                                                                                                                                                       Total Collector
                                                                                                                                                                            Rebate       Total Rebate   Total Item
                 SOLAR HOT WATER COLLECTOR                                   Model Number                                 Manufacturer                  Area (in m2)
                                                                                                                                                                              D             CxD           Count
                                                                                                                                                             C
Solar Hot Water Collector
Must comply with the Government of Canada's       Augments or replaces
list of ecoAction Qualified Solar Hot Water       central electric storage                                                                                                $240 per m2
Collectors. Visit:                                tank water heaters
http://ecoaction.gc.ca/ecoenergy-ecoenergie
      Replacement Reason                                                                                       Total facility conditioned area (m2)
                Efficiency Upgrade                                                         Total facility estimated daily hot water use (in litres)
                                                                                            Total facility estimated annual hot water use (in m3)
              Equipment Failure                                                      Percentage of annual hot water use met by solar collectors

                                                                                                                                                       Total Capacity
           NON-ELECTRIC CENTRAL STORAGE TANK                                                                                                                                Rebate       Total Rebate   Total Item
                                                                             Model Number                                 Manufacturer                   (MBtu/h)
               SERVICE HOT WATER HEATER                                                                                                                                       D             CxD           Count
                                                                                                                                                              C
Non-electric Storage Tank Service Water     Replaces central electric
Heater with a minimum thermal efficiency of storage tank water heaters                                                                                                   $2 per MBtu/h
90%
    Replacement Reason                        Fuel Type                                                         Total facility conditioned area (m2)
              Efficiency Upgrade                      Natural Gas                           Total facility estimated daily hot water use (in litres)
                                                      Oil                                    Total facility estimated annual hot water use (in m3)
              Equipment Failure                       Other




                                                                                            12
                                                                                   HOT WATER SERVICE
                                                                                                                                                             Item Count
           DOMESTIC HOT-WATER RECIRCULATION                                                                                                                                      Rebate         Total Rebate   Total Item
                                                                                  Model Number                                 Manufacturer                 (in all areas)
                     PUMP CONTROL                                                                                                                                                  D               CxD           Count
                                                                                                                                                                   C
                                                                                                                                                                             $12 for purchase
                                              For domestic hot water                                                                                                          of both timer
Timer and clip-on thermostatic controls for
                                              recirculation pumps                                                                                                               and clip-on
hot-water recirc pumps
                                              without existing controls                                                                                                        thermostatic
                                                                                                                                                                                  control


                                                                                                                                     Number of Units        Item Count           Rebate         Total Rebate   Total Item
                 DRAIN WATER HEAT RECOVERY                                  Model Number                   Manufacturer
                                                                                                                                        Served                   C                 D               CxD           Count

Drain-water heat recovery                             Minimum length of
A copper coil wrapped around a hot-water              60” for 3“ diameter
drainpipe. Cold water flows through the coil and is   drainpipe.
warmed by the drain water. The warmed water is        Minimum length of                                                                                                        $250 / drain
then added to the hot-water storage tank. System      48” for 4”                                                                                                                water heat
must have a minimum heat-recovery efficiency of       drainpipe. For heat                                                                                                    recovery system
40% and must be used to recover heat from             recovery from
electrically heated hot water.                        electrically heated
                                                      water.

    Replacement Reason                        Fuel Type                                                              Total facility conditioned area (m2)
            Efficiency Upgrade                        Natural Gas                                Total facility estimated daily hot water use (in litres)
                                                      Oil                                         Total facility estimated annual hot water use (in m3)
              Equipment Failure                       Other




                                                                                                 13
                                                                                             APPLIANCES
                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                ENERGY STAR® CLOTHES WASHER                                   Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D        (A+B+C) x D      Count
                                                                                                                       A               B                C
                                              Replaces an existing
Energy Star® clothes washer                                                                                                                                        $75 each
                                              clothes washer

                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                  IN-SUITE NATURAL GAS DRYER                                  Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D           AxD           Count
                                                                                                                       A               B                C
                                              Replaces an existing electric
Natural gas dryer for in-suite use                                                                                                   N/A              N/A          $200 each
                                              clothes dryer

                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                 CENTRAL NATURAL GAS DRYER                                    Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D           BxD           Count
                                                                                                                       A               B                C
Natural gas dryer for common laundry          Replaces an existing electric
                                                                                                                    N/A                               N/A          $200 each
facility                                      clothes dryer

                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                   ENERGY STAR® DISHWASHER                                    Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D        (A+B+C) x D      Count
                                                                                                                       A               B                C

Energy Star® dishwasher                       Replaces an existing unit                                                                                            $20 each

                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                 ENERGY STAR® REFRIGERATOR                                    Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D        (A+B+C) x D      Count
                                                                                                                       A               B                C
                                       Replaces existing unit equal to or
Energy Star® refrigerator                                                                                                                                          $60 each
                                       more than 8 years old

                                                                                                                Item Count for   Item Count for   Item Count for
                                                                                                                                                                    Rebate     Total Rebate   Total Item
                   ENERGY STAR® CEILING FANS                                  Model Number       Manufacturer    In-suite Area   Common Area        Other Area
                                                                                                                                                                      D        (A+B+C) x D      Count
                                                                                                                       A               B                C
                                              New or replaces an existing
Energy Star® ceiling fan                                                                                                                                           $25 each
                                              ceiling fan

                                                                                                                                                                                Total All      Total
                                                                                                                                                                                Rebates        Item
                                                                                                                   Total All Prescriptive Measures from Pages 6




                                                                                                14
SCHEDULE B CALCULATED SAVINGS MEASURES WORKSHEET
Provide information for each custom measure in your project. Please see the Program Guidelines for a list of additional documentation required for attachment.


                                                     CALCULATED SAVINGS MEASURES ELECTRICAL SUMMARY


                                                                                 Existing Equipment             New Equipment                Electricity Savings

Sr.                                                                                                                          Annual                       Annual
                        Measure Description                                   Summer Peak Annual Electricity Summer Peak                  Summer Peak
No.                                                                             Demand     Consumption         Demand
                                                                                                                            Electricity
                                                                                                                                            Demand
                                                                                                                                                         Electricity   Incentive
                                                                                                                                                                                   Total Rebate
                                                                  M&V Code                                                 Consumption                  Consumption     Option
                                                                                  kW          kWh/yr             kW                           kW
                                                                                                                             kWh/yr                       kWh/yr           G
                                                                                   A             B                C                          A-C
                                                                                                                                D                           B-D

                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                                                                                                                                             0.00           0.00                      $0.00


                             MEASURES TOTAL                                       0.00            0.00          0.00           0.00          0.00           0.00                      $0.00




                                                                                             15
                                              Better Buildings Partnership
                                                  Terms of Agreement
1.0 INCENTIVE PAYMENT: The City of Toronto shall pay the Applicant a financial incentive payment for the completion of the Project
described in Part 1 – Project Application ("Project Application") (“the Project”) following the Expected Project Completion Date identified in
the Project Application, subject to the City of Toronto verifying and confirming that the Project has attained the targeted peak demand
reduction identified in the Project Application. The agreed upon maximum amount of the financial incentive is identified in the City of
Toronto's Project approval letter and will be provided in the form of a lump sum payment. The incentive payment is inclusive of all applicable
taxes, except GST. The City of Toronto will not be responsible for any tax liability imposed on the Applicant as a result of any incentive given
pursuant to this Agreement. The City of Toronto shall have no liability for any amounts in connection of the Project in excess of the incentive
payment. Notwithstanding anything else contained in this Agreement, the Applicant agrees and acknowledges that the City of Toronto shall
have no obligation to pay any monies hereunder until it has determined in its reasonable discretion that the Project has

attained the peak demand reduction as set out in the Project Application. The Project, other than space cooling Projects, must be completed
and in service (as determined by the City of Toronto) by December 31, 2010. Space cooling Projects must be completed and in service (as
determined by the City of Toronto) by April 30, 2011. All invoices for total project costs for a Project, other than a space cooling Project, must
be submitted to the City of Toronto by January 31, 2011. All invoices for total project costs for a space cooling Project must be submitted to
the City of Toronto by May 31, 2011.

The City of Toronto shall not be responsible for making any financial incentive payments if a Project, other than a space cooling Project, is
not completed and in service by December 31, 2010 and invoices for total project costs are not received by January 31, 2011. The City of
Toronto shall not be responsible for making any financial incentive payments if a space cooling Project is not completed and in service by
April 30, 2011 and invoices for total project costs are not received by May 31, 2011.

2. APPLICANT ACKNOWLEDGEMENTS: The Applicant acknowledges and agrees that: (a) it did not begin the Project prior to the City of
Toronto's acceptance of the Application; (b) the City of Toronto alone shall submit the incentives paid under this Agreement for credit or
recognition by the Ontario Power Authority; and (c) the Applicant has not and shall not receive funding in or from any other Ontario Power
Authority sponsored energy efficient incentive program.


3.0 COVENANTS OF APPLICANT: The Applicant covenants and agrees that it shall:
(a) undertake and complete the Project identified in the Project Application in order to achieve the peak kW reduction target as set out in the
Project Application, all in accordance with the terms of this Agreement,
(b) comply with all applicable laws and requirements of all governmental authorities, and obtain and maintain all permits, licences, insurance
and approvals as may be required in connection with the Project, during the Term of this Agreement;
(c) maintain all the equipment of the Project in good working order and maintain the Project as determined by this Agreement without any
modification, for a continuous period of at least 36 months following the financial incentive payment by the City of Toronto failing which the
applicant shall be deemed to be in default and the City of Toronto may request repayment of all or a portion of the financial incentive
from the Applicant. This section shall survive the Term of this Agreement; and
(d) maintain complete and accurate records for the City of Toronto to verify the completion of the Project and attainment of peak demand
reduction for three (3) years following payment of the incentive, and provide the City of Toronto with reasonable access to such records, or
answers to questions regarding same, as may be necessary. This section shall survive the Term of this Agreement.

4.0 CONFIDENTIALITY: Each party shall maintain in strict confidence any and all proprietary and confidential information it may receive
about the other party under this Agreement, and will not disclose such confidential information to any other party without the prior written
consent of the disclosing party. Notwithstanding the foregoing, the City of Toronto shall be permitted to disclose confidential information
regarding this Agreement to the Ontario Power Authority. The Applicant further acknowledges that the City of Toronto is subject to the
Municipal Freedom of Information and Protection of Privacy Act (Ontario) and the Personal Information Protection and Electronic Documents
Act (Canada) and may be required to disclose confidential information concerning this Agreement in accordance with the provisions thereof.
This section shall survive the Term of this Agreement.
5.0 LIABILITY AND INDEMNITY: The Applicant does hereby indemnify and save harmless the City of Toronto and its Representatives
from all liability and all loss, cost or damages, including consequential damages, expenses and costs for injury to or death of any person, or
damage to or destruction of property of any person arising from or occurring by reason of (i) the Applicant's misrepresentation or breach of a
covenant or material obligation under this Agreement or (ii) the Applicant's actual or alleged implementation of the Project and its operation
or any matter contemplated by this Agreement, the Application or attachments thereto, whether negligent or otherwise. Notwithstanding
the fact that the City of Toronto may have reviewed the information contained in the Application for the purpose of assessing the possible
reduction of peak demand as a result of implementing the Project, it is understood and agreed that the City of Toronto shall not be held liable
for, and makes no representation or warranty regarding the Project, expressed or implied, including, but not restricted to, any representation
or warranty as or measures of the design or the capability respect to the expected or or workmanship
in any features to the fitness included in the Project or with of the material, equipment anticipated energy demand reduction, nor does the
City of Toronto warrant or certify that any equipment, features or measures included in the Project will satisfy the requirements of any law,
rule, specifications or contract. This section shall survive the termination of this Agreement.

6.0 ASSIGNMENT: The Applicant may not assign any of its rights or obligations hereunder without the prior written consent of the City of
Toronto.

7.0 AMENDMENTS: This Agreement may be amended only by mutual written agreement of the parties.
8.0 NON-WAIVER: No failure to exercise and no delay in exercising, any right or remedy under this Agreement will be deemed to be a
waiver of that right or remedy. No waiver of any breach of any term of this Agreement will be deemed to be a waiver of any subsequent
breach of that term.
9.0 TERM: Subject to any termination rights herein and those provisions that survive the termination of this Agreement, the term of this
Agreement shall commence on the date of acceptance of the project by the City of Toronto, as evidenced by the City of Toronto's approval of
the Project Application and shall terminate (1) for a Project that is not a space cooling Project, on April 30, 2011, and (2) for a space cooling
Project, on July 1, 2011, or following "completion" of the Project by the Applicant, whichever is earlier. "Completion" means that the
Applicant has submitted invoices, receipts and where applicable, reports required to verify performance and the financial incentive claimed
and that the peak load reduction has been achieved and verified by the City of Toronto.

10.0 TERMINATION: The City shall have the right, in its discretion, to terminate this Agreement by giving a written notice of termination
to the Applicant, where the Applicant has breached any covenant or material obligation under the Agreement and such breach has not been
remedied within 15 days after written notice thereof by the Applicant.
11.0 INDEPENDENT CONTRACTORS: Nothing in this Agreement shall be deemed to constitute a partnership or a joint venture or to
create any agency or fiduciary relationship between the parties.

12.0 GENERAL TERMS: This Agreement (comprising of the Project Application, Guidelines and Terms of Agreement) constitutes the entire
agreement between the parties with respect to the subject matter and supersedes all prior agreements, negotiations, discussions,
representations, warranties and understandings, whether written or verbal. This Agreement is governed by, and is to be construed and
interpreted in accordance with, the laws of Ontario. If any term of this Agreement is or becomes illegal, invalid or unenforceable, the
illegality, invalidity or unenforceability will be deemed severable and will not affect any other term of this Agreement.

13.0 ENVIRONMENTAL ATTRIBUTES: Environmental Attributes means all benefits or entitlements associated with decreased
environmental impacts now or in the future, direct or indirect, arising as a result of, relating to or in connection with the Program, and the
right to quantify and register such benefits and entitlements with competent authorities, including: (a) all right, title, interest and benefit in
and to any renewable energy certificate, credit, reduction right, offset, allocated pollution right, emission reduction allowance, carbon credit,
or other proprietary or contractual right, whether or not tradeable; (b) rights to any fungible or non-fungible attributes or entitlements
relating to environmental impacts, however arising; (c) any and all rights, title and interest relating to the nature of an energy source as may
be defined and awarded through applicable laws or voluntary programs, including all emission reduction credits; and (d) all revenues,
entitlements, benefits, and other proceeds arising from or related to the foregoing. For greater certainty, in the event that any governmental
or non-governmental agency, whether provincial, federal, national or international in scope or authority, creates or sanctions
a registry, trading system, credit, offset or other program relating to Environmental Attributes or their equivalent, the term "Environmental
Attributes" as used in these Terms of Agreement shall include the rights or benefits created or sanctioned under any such program or
programs to the extent available as a result of, or arising from, any Program. The Applicant hereby agrees to transfer and assign to the OPA,
unconditionally and absolutely, all of its right, title and interest in and to all Environmental Attributes arising from the Project and covenants
and agrees:
(i) not to sell, supply or deliver any of such transferred Environmental Attributes to the IESOAdministered Markets, other markets or any
other Person, or to retire any of such transferred Environmental Attributes, unless the OPA has requested and approved such sale, supply,
delivery or retirement;
(ii) not to participate in any voluntary programs with respect to any of such transferred Environmental Attributes without the prior written
consent of the OPA, which consent may be unreasonably withheld or delayed in the OPA's sole discretion;
(iii) to deliver all such transferred Environmental Attributes to the OPA free and clear of all liens, claims and encumbrances (other than those
in favour of the OPA); and
(iv) that, upon request by the OPA, it shall use commercially reasonable efforts to ensure the ownership by the OPA of all such transferred
Environmental Attributes, including:
(A) on behalf and in the name of or in trust for the OPA, quantifying, verifying, certifying and registering with the relevant Governmental
Authorities or other agencies all such transferred Environmental Attributes,
(B) obtaining, registering, certifying or delivering all such transferred Environmental Attributes or any evidence of the OPA's right, title and
interest thereto to the OPA, to the IESO-Administered Markets or other markets, or to any Person as the OPA may direct, on behalf, or for the
benefit, of the OPA, and/or
(C) assisting the OPA in doing any of the foregoing, for which the Applicant shall be reimbursed by the OPA for all reasonable expenses
incurred in respect thereof.

14.0 DEFINITIONS: In addition to terms defined in the body of the Agreement, "Representatives", in reference to a party, means the
party's directors, officers, employees, agents, contractors and volunteers, the party's Affiliates (as defined in the Ontario Business
Corporations Act) and such Affiliates' respective directors, officers, employees, agents, contractors and volunteers.
15.0 EXECUTION: This Agreement may be executed in counterparts and delivered by facsimile transmission, and the counterparts
together shall constitute an original.

								