Documents
Resources
Learning Center
Upload
Plans & pricing Sign in
Sign Out

280

VIEWS: 7 PAGES: 2

									KLEEN-FLO TUMBLER INDUSTRIES LIMITED

MATERIAL SAFETY DATA SHEET

PAGE 1

SECTION I-MATERIAL IDENTIFICATION AND USE

Material Name/Identifier: Manufacturer's Name: City: Postal Code: Chemical Name: Chemical Formula: Material Use:

Armashell Metal Polish Kleen-Flo Tumbler Industries Ltd Brampton L6T 4N1 N.Ap (mixture) N.Ap (mixture) Cleaner/Polish

Stock No. Street Address: Province: Emergency Phone #: Chemical Family: Trade Names & Synonyms: Molecular Weight:

280 75 Advance Blvd. Ontario (905) 793-4311 N/Av. (Mixture) None N.Ap (Mixture)

SECTION II-HAZARDOUS INGREDIENTS OF MATERIAL

Hazardous Ingredients Hydrotreated Light Distillate Ethylene Glycol Monobutyl ether C.A.S. 64742-47-8 111-76-2

Approximate Concentration 15 - 40 % 1-5%

LD50 Species & Route >5000 mg/kg rat-oral 1746 mg/kg rat-oral

LC50 Species & Route 1400ppm (4hr) rat-inh. 700 ppm (7hr) rat-inh.

SECTION III-PHYSICAL DATA FOR MATERIAL

Physical State: Specific Gravity: Boiling Point: Freezing Point: % Volatile Vapour Density(Air=1): pH:

Semi viscous liquid 1.06 -1.11 N/E 0 oC N/E >1 7.8 - 8.5

Odour/Appearance: Odour Threshold(p.p.m.): Evaporation Rate: Solubility in Water: Vapour Pressure(mm)Hg: Coefficient of Water/Oil Distribut:

Off white liquid with solvent odor 25ppm (as NH3) <1 Miscible N/E N/E

SECTION IV-FIRE AND EXPLOSION HAZARD OF MATERIAL Flammability Yes/No Auto Ignition Temperature: Flashpoint and Method: Upper Flammable limit (%vol) Explosion Data: No None None N/E Sensitivity to Mechanical Impact: No If yes under which conditions: Means of Extinction: Dry Chemical, CO2 Foam, Water Hazardous Combustion Products: Lower Flammable Limit (% by volume): Sensitivity to Static Discharge: N/A N/E N/E

SECTION V-REACTIVITY DATA

Chemical Stability Yes/No: Incompatibility to Other Substances Yes/No: Reactivity and under what conditions? Hazardous Decomposition Products: N/E: not established

Yes Yes

If NO under which conditions? If so which ones? Strong Acid and Oxidizers

Open flames, fire, hot surfaces. N/E N.Ap.:not applicable N/Av.: not available

Material Name/Identifier:

Armashell Metal Polish

Stock No.

280

PAGE 2

SECTION VI-TOXICOLOGICAL PROPERTIES OF PRODUCT Route of Entry: Effects of Acute Exposure: --SKIN CONTACT --SKIN ABSORPTION --EYE CONTACT --INHALATION --INGESTION Headache,vomiting, dizziness,nausea,dermatitis, local irritation,corrosion of the mouth, esophagus and stomach. Effects of Chronic Exposure: LD 50 of Product: Irritancy of Product: Sensitization of Product: None known N/E Eyes and skin irritant N/E LC 50 of Product: Exposure Limits of Product: Toxicologically Synergistic Materials: N/E N/E N/E

--CARCINOGENICITY --REPRODUCTIVE EFFECTS --TERATOGENICITY --MUTAGENICITY: Not known

SECTION VII-PREVENTIVE MEASURES Personal Protective Equipment to be used: Gloves(specify): Respiratory(specify): Respiratory Protection: Engineering Controls: Leak and Spill Procedure: Waste Disposal: Storage Requirements: Handling Procedures and Equipment: TDG Classification: WHMIS Classification: Keep away from children. Do not ingest or inhale. Handle with care. Non regulated. Non regulated. Vinyl or Rubber Niosh approved mask if fumes are exessive Eye (specify): Safety Glasses Clothing: Not required

If used indoors or on a continuous basis, use of cartridge type respirator is recommended Local exhaust and general mechanical ventilation. Rinse away or use absorbent material Standard methods approved in your region. Store at room temperature. Keep closed when not in use.

SECTION VIII-FIRST AID MEASURES

Eye: Skin: Inhalation Ingestion:

Wash with water for at least 15 minutes. Consult a physician. Flush with clean soapy water for 5-10 minutes, apply hand cream. Remove clothing. Move patient to fresh air. DO NOT INDUCE VOMITNG. Rinse mouth. Give water. Seek medical assistance.

SECTION IX- PREPARATION DATE OF M.S.D.S.

Additional Info/Comments: Phone Number: Date Prepared: (905) 793-4311 January 2, 2009.

Sources Used: Supplier's data Prepared By: Quality Control Laboratory Kleen-Flo Tumbler Industries Limited

THIS SHEET SUPERSEDES ANY OTHER M.S.D.S. PREVIOUSLY PREPARED N/E: not established N.Ap.:not applicable N/Av.: not available


								
To top