									                 +V Power Input
                                                                                                   Notes for E-Motor operation:


                                                                                                   1) User must de-select ‘Reverse acting valve’ feature in standard HFS-J GUI.
                                  AGC5
                                  FUSE
                                                                                                   2) Module outputs 0-5VDC to represent 0 – 100% fan speed ( 0V = Minimum fan speed )

                         5                                                                         3) 12 or 24V operation – select coil voltage to match vehicle voltage
                         6                  Fan Reverse Switch                                     4) Use suitable fuse rated for valve current in power supply line to protect controller and
                                                                                                   wire harness
                             CAN_H                     Charge Air Temp
                         3                                                                         5) Ensure all cables are rated to optimize power, ground and all input/output voltages and
                                     J1939 I/O         Coolant Temp
                                                                                                   currents.
                         4   CAN_L                     Transmission Temp
                                                                                                   6) Use twisted pair for J1939 data cables
                         1
Hydraulic Fan            8                                                                         7) This controller does NOT have internally fitted 120 Ohm J1939 termination resistors.
System Controller        2                                                                         8) User must supply and fit item in 7) as required to maintain DATA BUS integrity
Part No: HFS-J-Emotor    9
                                                                                                   9) Alarm output ( pin 10 ) use is fitted as standard and an optional customer feature
                                                                        0-5VDC output
                        12                                            ( 10mA max O/P )
                               Fan Reverse Valve




                                                                                                              1    2     3        4   5     6
                        11
                                                                                                                                                         View looking at male connector on
                        10                                                                                                                                   HFS-J-Emotor controller
                                  Alarm Output
                         7                                                                                    12   11    10       9   8     7




                 0V Power Input



                                                                                                                                 High Country Tek, Inc. - Nevada City, CA, 95959

                HFS-J-Emotor                                                                                                                        HFS-J-Emotor Wiring diagram for
                                                                                                                                                    Hydraulic Fan System Controller
       J1939 controller with 0-5VDC output
                                                                                                                         SIZE             FSCM NO                         DWG NO                 REV
                                                                                         Drawn By: Gary Gotting
                                                                                                                             A                                        HFS-J-Emotor-B             A
                                                                                            Date: 4/29/2010             SCALE             NTS                              SHEET       1 OF 2
                                                           A
                                     B                                                                                                                           Label        Inches      Millimeters

                                                               C
                                                                                                                                                                  A           3.77          96.0
                                                                                                                                                                  B           1.625         41.3

                       STATUS



                                    ERROR
                                     REV /
                                                 FAN CONTROLLER                                                                                                   C         Ø 0.186          4.7
                                                               SAE J1939 Compatible
                                                                                                                                                                  D           3.82          97.0
                                                           HFS-J-Emotor
                                                                                                                                                                  E           3.10          78.7
                                                               S/N: AXXXX                                                                                         F           0.46          11.7
    D
    E




                                                                                                                RS232 serial communication connection used for    G           3.25          82.6
                                www.highcountrytek.com                                                          programming and diagnostics only. NOT
                                                                                                                connected during normal operation
                                                                                                                                                                  H           1.75         44.95
                                                      Made in USA                     RS232                                                                        I          0.64          16.3
                                                                                                          C
                                      1      2    3    4   5     6                                      3 x #8 Screw
                                                                                                                                                                  J           0.26           6.6
                  C                                                                           C
                                      12     11   10 9     8     7




F                               J                              G

Notes:                                                                                                                      H
1) Programming cable removed from drawing for clarity
2) Fully encapsulated in flame retardant resin                                                                                    I
3) Mount unit with connector facing outwards
4) Mount controller in coolest location possible
5) Use all three (3) #8 screw locations to ensure module security
6) Mating connector Parts:-
          Deutsch # DT06-12SB-P012
                                                                                                                                         High Country Tek, Inc. - Nevada City, CA, 95959
          Deutsch # W12S – Lock
          Deutsch # 0462-201-16141 – Socket pins
                                                                                                                                                 HFS-J-Emotor Fan system controller
                HFS-J-Emotor                                                                                                          SIZE        FSCM NO                   DWG NO                      REV
                                                                                                  Based on HFS-J Platform
         J1939 controller with 0-5VDC output                                                                                                                             HFS-J-Emotor-B
                                                                                                      Date: 4/29/2010             SCALE           NTS                        SHEET         2 OF 2

								
To top