									                Healthcare-Associated
            Infection Control Solutions of
                   Welcome to the World
                           Kimberly-Clark

    Micro Cool Gowns




1
1
        Healthcare-Associated
    Infection Control Solutions




2
                                                  Healthcare-Associated
                                              Infection Control Solutions

    KIMBERLY-CLARK* MICROCOOL* Gowns for breathable
    impervious protection

    Strikethrough of blood and other fluids is a major cause
    of HAI’s such as Hepatitis B, C and HIV.
     1. MICROCOOL* gowns offer the highest level of
        protection for lengthy, fluid intensive
        procedures (meet high performance requirements
        EN13795)
     2. Proprietary breathable impervious
        technology provides impervious protection
        and excellent comfort
     3. Education and implementation support to define
        your optimal gown mix



3
                                                     Healthcare-Associated
                                                 Infection Control Solutions

    KIMBERLY CLARK FABRIC INNOVATION: MICROCOOL
    Breathable…
    Thanks to the micro porous                                          Outer layer:
    film that permits vapor to easily                                   Spunbond
    pass through the gown,
    dispelling heat and keeping the
                                            Breathable
    wearer cool and comfortable
                                            Film


                                                                                  Inner layer:
                                                                                  SMS
                                    … and Impervious
                                    The film center layer provides
                                    impervious protection against blood and
                                    body fluids. It is impervious to both fluid
                                    and viral insults.

4
                                               Healthcare-Associated
                                           Infection Control Solutions

    MICROCOOL IS 100% IMPERVIOUS
    Why is (all over) impervious protection needed?
       Management of risk of spraying/splashing outside critical areas
       HIV, MRSA, Hepatitis C, bloodborne pathogens and all Hospital Aquired
        Infection
       Not only from patient to staff but also the opposite way

    Usually, impervious protection has always been synonymous with
      feeling hot and uncomfortable
    Through Kimberly-Clark’s proprietary breathable impervious
      technology, Microcool* offers impervious protection without
    compromising comfort
    MicroCool* is therefore ideal for use in fluid intensive procedures &
      lengthy procedures


5
                                                  Healthcare-Associated
                                              Infection Control Solutions

    MICROCOOL IS PROVEN TO BE IMPERVIOUS
     Impervious to Viral insults – measured by:
       ASTM F1671, Resistance to penetration by bloodborne pathogens
         Pass
         This is required in the US by the FDA (Food & Drug Administration) to be able
         to say that a product is “impervious”

     Impervious to Blood and Body Fluids – measured by:
       ASTM F1670, Resistance to Blood Penetration
         Pass

     Strikethrough CEN Hydrohead test (EN 20811) for High Performance
       Gown
       MicroCool* results are above requirements: > 150 cm

     CEN Wet Microbial Penetration (EN ISO 22610)
       Pass
6
                                                     Healthcare-Associated
                                                 Infection Control Solutions

    US TEST METHODS
    Test                    Description
    US ASTM   Resistance    Measures the resistance of materials to Penetration by Synthetic
    F1670     to Blood      Blood.
              Penetration   A fabric is clamped to a test cell and exposed to 55-60 ml of synthetic
                            blood for one hour. During that hour, the liquid pressure is raised to 2
                            pounds per square inch for five minutes, and then left at normal air
                            pressure for the remainder of the time.
                            After the hour, if there is no visible evidence of synthetic blood
                            penetrating the sample, the fabric "passes" the test


    US ASTM   Resistance    Measures the resistance of materials to Viral Penetration.
    F1671     to            Fabrics are challenged on one side (i.e. - outside of a gown) with viral
              penetration   solution under pressure of 2 psi for five minutes and then allowed to
              by            sit for 55 minutes at normal pressure. The surface of the opposite
              bloodborne    side of the fabric (i.e. - the inside of the gown) then undergoes a
              pathogens     culturing process to detect the presence of the viral challenge
                            solution. Results are then recorded as pass or fail



7
                                                          Healthcare-Associated
                                                      Infection Control Solutions

      EU TEST METHODS
    Test                          Description
    Hydrohead       Resistance    Measures the resistance of fabrics to liquid penetration by water
    test            to Blood &    under constantly increasing hydrostatic pressure.
    (EN 20811)      body fluids   A fabric sample is subjected to water pressure which is increased
                                  at a constant rate until leakage appears on the outer surface of the
                                  fabric sample. The head height results are then recorded in
                                  centimeters of water pressure on the fabric sample.
                                  A higher value indicates greater resistance to water penetration.

    Wet Microbial   Resistance    Used to determine a fabric's resistance to penetration of liquids
    Penetration     to viral      carrying bacteria, while being subjected to mechanical rubbing.
    (EN ISO         insults       Test fabric is subjected to material that has been contaminated with
    22610)                        Staphylococcus aureus suspension. If penetration occurs due to
                                  the combined effect of liquid pooling and rubbing, bacteria will
                                  collect on to an agar surface, incubated, and formed colonies can
                                  be counted.
                                  Per pr EN 13795-3: 2004, test method and target values are tentative
                                  and will be reviewed within one year after publishing.



8
                                                 Healthcare-Associated
                                             Infection Control Solutions

    MICROCOOL IS BREATHABLE
     MicroCool* passes the Water Vapor Transmission Rate Test
        This test is used to indicate "breathability" of film based fabrics.
        Moisture vapor particles are much smaller in size than blood droplets and
         other fluids, as well as viruses and bacteria.
        A dry chamber is separated from a wet chamber (of known temperature and
         humidity) by a permanent guard film and the sample. Water vapor is
         introduced and the transmission rate through the sample is calculated using
         electrical signals




9
         Healthcare-Associated
     Infection Control Solutions




10
                                     Healthcare-Associated
                                 Infection Control Solutions
     • For the Surgeon
• Designed for fluid-intensive
         procedures




11
                                        Healthcare-Associated
                                    Infection Control Solutions
      • For the Surgical Team
• Designed for low - to- moderate
           fluid contact




 12

								