S H E D SEALED HOUSING FOR EVAPORATIVE DETERMINATIONS

Document Sample
scope of work template
							                                        SHED
       SEALED HOUSING FOR EVAPORATIVE DETERMINATIONS




                                     (Photo courtesy of Subaru)

Webber EMI manufactures a wide range of SHEDs in a variety of sizes, ranging from 10 cu-ft Micro
SHEDs to full sized Vehicle SHEDs capable of testing HD construction vehicles. Starting from one of
our standard configurations, a SHED can be designed to customer specifications with regard to size,
window placement, vehicle door type, and other performance or capability options.
All Webber EMI SHEDs incorporate a modular systems design that allows the basic Fixed Volume /
Fixed Temperature (FV/FT) enclosure to be upgraded to full Variable Volume / Variable
Temperature (VV/VT) enclosure. These upgrades can even be performed on-site, after installation.


                             _______________________________
                             1307 S Wanamaker Ave, Ontario, CA 91761
                                  909.605.6800 Fax: 909.605.6811
                                       www.WebberEMI.com
FV/FT Vehicle SHED

The Webber EMI Model 101 Vehicle
SHED is available as a Fixed-Volume
/ Fixed-Temperature (FV/FT) full-
vehicle test chamber used for
evaporative emissions testing. It is
also suitable for testing motorcycles,
small tractors and other machines &
equipment of similar size.




                                                           (Photo courtesy of Harley Davidson)




VV/VT Vehicle SHED

The Webber EMI Model 101 Vehicle
SHED is also available as a Variable
Volume / Variable Temperature
(VV/VT) SHED. This SHED is
designed to support a full range of test
protocols and temperature profiles
between 45 ºF and 120 ºF. Using the
Webber EMI moveable roof system,
absolute      SHED       volume       is
automatically controlled to maintain
zero-differential pressure between the
SHED interior and ambient laboratory
conditions. It is designed for testing
large equipment such as cars, trucks,
tractors and other large machinery
                                                              (Photo courtesy of Hyundai)



                                    _______________________________
                                    1307 S Wanamaker Ave, Ontario, CA 91761
                                         909.605.6800 Fax: 909.605.6811
                                              www.WebberEMI.com
Micro SHED

The Webber EMI Model 103 Micro
SHED is designed for testing discrete
fuel system components such as fuel
containers, hoses, and canisters as
well as complete miniature systems or
engines.




                                                        (Photo courtesy of Yachiyo of America)




Mini SHED

The Webber EMI Model 102 Mini
SHED is suitable for testing small
equipment such as ATVs, lawn mowers
and other objects equivalent in size.




                                                 (Photo courtesy of the California Air Resources Board)

                                 _______________________________
                                  1307 S Wanamaker Ave, Ontario, CA 91761
                                       909.605.6800 Fax: 909.605.6811
                                            www.WebberEMI.com
Running Loss SHED

The Webber EMI Model 106 Running
Loss SHED is a modified version of
our full-sized Vehicle SHED. This
extra long SHED, equipped with
special air handling equipment, a
proportional speed fan, vehicle
combustion makeup air, and an
auxiliary personnel door, is combined
with a centrally located dynamometer
to accept both front and rear wheel
drive vehicles. In addition to full
exhaust emissions testing capability,
this SHED supports all applicable
diurnal evaporative emissions test
protocols.                                       (Photo courtesy of the California Air Resources Board)




On-Board Refueling & Vapor
Recovery

Webber EMI can provide On-Board
Refueling / Vapor Recovery (OR/VR)
capability for any of our SHEDs.
Using several different methods,
vehicles or other fuel-dependent
machines can be re-fueled while the
SHED is sealed.




                                                            (Photo courtesy of Volkswagen)



                All Webber EMI SHEDs are available as full VV/VT enclosures, or as
                  FV/FT enclosures that can later be upgraded to VV/VT capability.

                                  _______________________________
                                  1307 S Wanamaker Ave, Ontario, CA 91761
                                       909.605.6800 Fax: 909.605.6811
                                            www.WebberEMI.com
                                                     SHED Systems
                                Micro SHED                   Mini SHED                  Vehicle SHED
                                (10-100 cu ft)             (100-1000 cu ft)            (1000-2000 cu ft)

                                     Fixed Volume / Fixed Temperature (FV / FT)
Standard Volume                    48 cu ft                    288 cu ft                   1680 cu ft
ID (W x H x L)                     4'x4'x3'                    6'x6'x8'                    10'x8'x21'
Temperature                          72° F                       72° F                        72° F
Vehicle Door                     Side-hinge                  Side-hinge                    Top-hinge
Heat & Cool Unit                Self contained              Self contained               Self contained
Purge System                 Single poppet valve         Single poppet valve          Single poppet valve

                                                              Options
                                              (Available at time of manufacture only.)
Volume                        Custom volume                Custom length               Custom length
                               Guillotine or                Guillotine or
Vehicle Door                                                                             Guillotine
                             Top/Bottom-hinge            Top/Bottom-hinge
Personnel Door                        --                          --                    Side-hinge
Heating & Cooling Unit       Facility dependent         Facility dependent           Facility dependent
Purge System                 Dual poppet valves         Dual poppet valves          Dual poppet valves

                                                             Upgrades
                                        (Available both at manufacture and after installation.)

                                 Variable Volume / Variable Temperature (VV / VT)
                              Moveable Roof,              Moveable Roof,              Moveable Roof,
Volume System                Mass-Flow Balance,          Mass-Flow Balance,          Mass-Flow Balance,
                               or Bag system               or Bag system               or Bag system
Standard Temp Range            65° F - 105° F              65° F - 105° F              65° F - 105° F
Extended Temp Range            45° F - 145° F              45° F - 145° F              45° F - 145° F

                               Fuel Tank Temperature Management System (FTTMS)
Heater Outlets                       1                         Up to 3                      Up to 3
Heater Power                    2kW / outlet                 2kW / outlet                 2kW / outlet
Auxiliary Outlets                    1                         Up to 2                      Up to 2
Auxiliary Power                 20A / outlet                 20A / outlet                 20A / outlet

                                   Onboard Re-fueling / Vapor-Recovery (OR / VR)
                                                        Glove & Nozzle Boots        Glove & Nozzle Boots
Nozzle Access                Quick Disconnects
                                                        or Quick Disconnects        or Quick Disconnects

         If you need additional equipment not shown here, contact us with your requirements.

                                _______________________________
                                1307 S Wanamaker Ave, Ontario, CA 91761
                                     909.605.6800 Fax: 909.605.6811
                                          www.WebberEMI.com
                               Why choose a Webber EMI SHED?
Each Webber EMI SHED uses our exclusive ‘Ure-lok’ interlocking panel design, which serves to double the
sealing surface between each panel. Panels are held together by a patented mechanical interlocking system to
further increase sidewall rigidity and live load ratings. Each panel employs a chemically bonded cross-section
with an exterior surface of aluminum, an interior surface of type-304 stainless steel, and a 4” thick fire retardant
urethane foam core. The panels contain no organic materials (i.e., wood or other cellulose-based materials),
which can warp or naturally deform. All panel-mounted windows use triple-pane safety glass and are fully sealed
and trimmed inside and out. This ensures that all Webber EMI SHEDs have a durable and attractive exterior and
an easy to clean interior surface that is impermeable and non-reactive to both hydrocarbons and test fuels.
Webber EMI SHEDs can be fitted with either a top-hinged, tilt-up or vertical-sliding, ‘guillotine’ style vehicle
door. Vehicle SHEDs can also include a separate, side-opening personnel door. All door styles feature
pneumatic seals and triple-pane safety glass windows.
Every Webber EMI SHED structure fully complies with the leakage limits and HC retention requirements stated
in CFR 40 86.117-96. Additionally, the SHED structure is designed to safely withstand an internal-to-external
pressure differential of +/- 2 “H20 (+/- 0.5 kPa) without deformation or other negative effect.
In addition to our exclusive Moveable-Roof volume compensation system, Webber EMI is the only manufacturer
to offer a Mass-Flow Balance (MFB) orifice system, and a conventional ‘bag-based’ volume compensation
system. These systems are all designed to maintain a zero pressure differential relative to outside ambient
conditions across the SHED’s entire temperature range. While all three systems provide excellent accuracy and
repeatability, the Webber EMI Moveable-Roof system has been designed to eliminate the need for Tedlar bags or
other artificial devices to facilitate SHED expansion. By eliminating the ‘dead space’ typically required in a
‘bag-based’ SHED, the working volume of a Moveable-Roof SHED is reduced, thereby resulting in improved
testing accuracy – an absolute must for the new ‘zero evap’ regulations. Additionally, the Moveable-Roof system
provides precise feedback of SHED volume at ALL times during the test procedure, thus allowing for real-time
reporting of HC mass values.
Webber EMI SHEDs use dedicated, self-contained HVAC systems as standard equipment. Each system is sized
according to the SHED enclosure and the customer’s temperature requirements. In the case of VV/VT SHEDs,
the HVAC systems are capable of moving the SHED air temperature between 65 and 105 °F in approximately 1
hour. Custom systems are available to produce and maintain SHED air temperatures below 40 and above 140
°F. In all cases, Webber EMI SHEDs are capable of maintaining temperatures required for diurnal emission and
hot soak testing as described in CFR 40-86.117.96 and CFR 40 part 86 subpart B, respectively.
All Webber EMI SHED systems utilize a Windows-based, proprietary SHED data acquisition and control system.
This system is versatile, powerful and very user-friendly. It contains a menu of all pertinent U.S. EPA and
California ARB SHED test procedures, ready for immediate use. It also provides the ability to easily develop and
save custom test procedures for internal product development. This control system is capable of being used with
a variety of HC analyzers. In addition to the PC-based controller, Webber EMI SHED systems include a local
control panel, which allows for full manual operation of the SHED and various sub-systems.
All Webber EMI SHED systems are supplied with a number of safety systems such as a Low Explosion Limit
(LEL) detection system and pressure / temperature limiting switches. Optional safety equipment includes fire
suppression systems, retractable vehicle grounding straps, rotating light beacons, and audible alarms. All safety
systems are interlocked with both the manual and computer control systems to ensure safe operation.
  Webber EMI SHEDs… recognized for their accuracy, durability, and quality… since 1975

                                    _______________________________
                                     1307 S Wanamaker Ave, Ontario, CA 91761
                                          909.605.6800 Fax: 909.605.6811
                                               www.WebberEMI.com

						
Related docs