        Hold to run control panel for GfA ELEKTROMATEN with mechanical limit NES




       Approvals and certificates
       Certified according to DIN EN 12453




   Technical data

          For all GfA ELEKTROMATEN                                 Supply voltage: 1x230V/N/PE;
          with mechanical limit switch NES.                        3x230V/PE; 3x400V/N/PE; 3x400V/PE
          Up to 3.0 kW motor power                                 Control voltage 24V DC



   Housing

          Dimensions W x H x D: 190 x 300 x 115 mm                 Live electrical parts covered
          IP65 with direct connection or IP54 with CEE plug        Encl. drilling template and fixing elements
          We recommend the use of an additional cover
          if the panel is to be subject to constant spraying
          with water or installed in the open air.
          (Page 7.82)




   Description

          Integrated OPEN-STOP-CLOSE push-button                   Plug-in connections for ELEKTROMATEN                   Blatt 6.11
          Available with optional ready-wired CEE plug and         Connection cable for ELEKTROMATEN
          1m of cable, replaces main switch according to           from 3 up to 15m available.
          DIN EN 12453.                                            Plug-in connection for spiral cable
          Adjustment settings via selector switch                  Emergency stop-button (optional)
          with 7-segment display.                                  Key-switch (optional)
                                                                                                                          page 7.21




   Functions

          Selectable operating mode:                               Slack-rope / pass-door switch contact is available.
          • Hold to run CLOSE / OPEN                               Status and information display
          • Hold to run CLOSE / self-hold OPEN                     Operations cycle counter (non re-settable)
          • Hold to run FULLY CLOSE FUNCTION / self-hold OPEN      Maintenance indicator:
            Keep the CLOSE button pressed until the door           • Adjustment range: 1,000 to 99,000 cycles
            is completely CLOSED.                                  • After reaching the adjusted maintenance cycles,
            If the CLOSE button is released early, the door will     the selected function will be displayed or changes
            reverse automatically to its OPEN position.              the door operation when service is due.


Subject to measurement and design revisions.
            Connectable accessories TS 956
1-2007




                     3 x 400 V/N/PE
                     3 x 400 V/PE      230 V      Relay
                     3 x 230 V/PE     External   contact
                     1 x 230 V/N/PE
page 7.22




                                                           Subject to measurement and design revisions.
                                                                                                               1-2007
        Control panel TS 958


        Hold to Run control panel for GfA ELEKTROMATEN with digital limit switch DES




       Approvals and certificates
       Certified according to DIN EN 12453




   Technical data

          For all GfA ELEKTROMATEN with digital limit          Supply voltage: 1x230V/N/PE;
          switch DES.                                          3x230V/PE; 3x400V/N/PE; 3x400V/PE
          Up to 3.0 kW motor power                             Control voltage 24V DC




   Housing

          Dimensions W x H x D: 190 x 300 x 115 mm             Live electrical parts covered
          IP65 with direct connection or                       Encl. drilling template and fixing elements
          IP54 with CEE plug
          We recommend the use of an additional cover
          if the panel is to be subject to constant spraying
          with water or installed in the open air.
          (Page 7.82)




   Description
                                                                                                             page 7.25




          Integrated OPEN-STOP-CLOSE push-button               Connection cable for ELEKTROMATEN
          Available with optional ready-wired CEE plug         from 3 up to 15m available.
          and 1m of cable, replaces main switch according      Plug-in connection for spiral cable
          to DIN EN 12453.                                     Emergency stop-button (optional)
          Adjustment settings via selector                     Key-switch (optional)
          switch with 7-segment display.
          Plug-in connections for ELEKTROMATEN




Subject to measurement and design revisions.
            Functions
1-2007




              Comfortable limit adjustment and programming of        Slack-rope / pass-door switch contact is available.
              all functions from the ground.
              Initial rapid limit adjustment in 4 steps,
              when adjusted the door moves in CLOSE / OPEN
              hold to run function.

              Selectable operating mode:
              • Hold to run CLOSE / OPEN
              • Hold to run CLOSE / self-hold OPEN
              • Hold to run FULLY CLOSE FUNCTION /
                self-hold OPEN.
                Keep the CLOSE button pressed until the door
                is completely CLOSED.
                If the CLOSE button is released early, the door
                will reverse automatically to its OPEN position.




            Special functions

              Status and information display                         Monitoring of the door operation integrated.
              Counter for program changes                            This recognizes any sudden change in the door
              Operations cycle counter (non re-settable)             operation (e.g. the door is locked). The digital limit
              Maintenance indicator:                                 switch DES detects any change of movement and
              • Adjustment range: 1,000 to 99,000 cycles             switches the control panel OFF.
              • After reaching the adjusted maintenance cycles,      Overload monitoring in open direction:
                the selected function will be displayed or changes   • Only for balanced doors, detects any
                the door operation when service is due.                sudden changes in balancing behaviour
                                                                     • Self-learning, no reaction by overload monitoring
                                                                       when slowly changes in spring tension.
                                                                     • Two levels of sensitivity may be adjusted.
page 7.26




                                                                                                    Subject to measurement and design revisions.
   Connectable accessories TS 958




                                                                      1-2007
                           3 x 400 V/N/PE
                           3 x 400 V/PE         230 V      Relay
                           3 x 230 V/PE        External   contact
                           1 x 230 V/N/PE




                                                                    page 7.27




Subject to measurement and design revisions.
                                                                                                                  1-2007
        Control panel TS 961


        Automatic control panel for GfA ELEKTROMATEN with mechanical limit switch NES




       Approvals and certificates
       Certified according to DIN EN 12453




   Technical data

          For all GfA ELEKTROMATEN                               Supply voltage: 1x230V/N/PE;
          with mechanical limit switch NES.                      3x230V/PE; 3x400V/N/PE; 3x400V/PE
          Up to 3.0 kW motor power                               Control voltage 24V DC




   Housing

          Dimensions W x H xD: 190 x 300 x115 mm                 Live electrical parts covered
          IP65 with direct connection or IP54                    Encl. drilling template and fixing elements
          with CEE plug
          We recommend the use of an additional cover
          if the panel is to be subject to constant spraying
          with water or installed in the open air (Page 7.82).
                                                                                                               Blatt 6.11




   Description
                                                                                                               page 7.31




          Integrated OPEN-STOP-CLOSE push-button                 Connection cable for ELEKTROMATEN
          Available with optional ready-wired CEE plug and       from 3 up to 15m available.
          1m of cable, replaces main switch according to         Plug-in connection for spiral cable
          DIN EN 12453.                                          Emergency stop-button (optional)
          Adjustment settings via selector switch                Key-switch (optional)
          with 7-segment display.                                Latching switch for intermediate stop
          Plug-in connections for ELEKTROMATEN                   adjustment (optional).




Subject to measurement and design revisions.
            Functions
1-2007




              Selectable operating mode:                              Intermediate stop position
              • Hold to run CLOSE / OPEN                              (may be selected ON / OFF):
              • Hold to run CLOSE / self-hold OPEN                    • Stop position is free adjustable between final
              • Self-hold CLOSE / OPEN                                  OPEN and CLOSE position.
              Automatic safety-edge detection                         • Automatic closing starts also from intermediate
              and evaluation:                                           stop position.
              • Normally closed 1K2 with testing system               Signal light mode with fore-warning or changeover
              • Normally open 8K2 resistor                            relay contact (freely programmable).
              • Optical safety edge (e.g. Brand Fraba)                Plug-in connection for:
              Automatic closing feature adjustable from               • Radio control
              1 to 240 seconds (ON / OFF possible):                     or
              • The door closes automatically from final open or      • UBS junction module with 5 ports for fitting
                intermediate stop position after the adjusted time.     UBS accessories e.g. push button,
              • Timer can be interrupted by triggering of the           photo-beam etc. (UBS optional accessories, page 7.77)
                photo-beam; adjustable function.
              Slack-rope / pass-door switch contact is available.
              Terminals for one pull-switch or radio control
              1-channel available, function programmable:
              • On command, the door travels to its OPEN
                or CLOSE position, if a new command would
                be issued during closing, the door re-opens.
                or
              • Step by Step Function
                OPEN-STOP-CLOSE-STOP-…




            Special functions

              Status and information display                          Operations cycle counter (non re-settable)
              Checking of program changes                             Maintenance indicator:
              Dynamic running-time monitoring:                        • Adjustment range: 1,000 to 99,000 cycles
              • During each upwards movement the running              • After reaching the adjusted maintenance cycles,
                time is monitored and compared to the last              the selected function will be displayed or changes
                reference time.                                         the door operation when service is due.
              • If the timer counts 7 seconds more than previous
                reference time the control switches OFF.
page 7.32




                                                                                                     Subject to measurement and design revisions.
   Connectable accessories TS 961




                                                                           1-2007
                                                                24 V

                                                              External




                           3 x 400 V/N/PE
                           3 x 400 V/PE         230 V
                           3 x 230 V/PE        External
                           1 x 230 V/N/PE



                                                          U
                                                          B
                                                          S




                                                                         page 7.33




Subject to measurement and design revisions.
                                                                                                                 1-2007
        Control panel TS 970


        Automatic control panel for GfA ELEKTROMATEN with digital limit switch DES




       Approvals and certificates
       Certified according to DIN EN 12453




   Technical data

          For all GfA ELEKTROMATEN with digital                  Supply voltage: 1x230V/N/PE;
          end-limit switch DES.                                  3x230V/PE; 3x400V/N/PE; 3x400V/PE
          Up to 3.0 kW motor power                               Control voltage 24V DC




   Housing

          Dimensions W x H x D: 190 x 300 x 115 mm               Live electrical parts covered
          P65 with direct connection or IP54                     Encl. drilling template and fixing elements
          with CEE plug
          We recommend the use of an additional cover
          if the panel is to be subject to constant spraying
          with water or installed in the open air (Page 7.82).




   Description
                                                                                                               page 7.41




          Integrated OPEN-STOP-CLOSE push-button                 Connection cable for ELEKTROMATEN
          Available with optional ready-wired CEE plug           from 3 up to 15m available.
          and 1m of cable, replaces main switch according        Plug-in connection for spiral cable
          to DIN EN 12453.                                       Emergency stop-button (optional)
          Adjustment settings via selector switch                Key-switch (optional)
          with 7-segment display.                                Latching switch for intermediate stop
          Plug-in connections for ELEKTROMATEN                   adjustment (optional).




Subject to measurement and design revisions.
            Functions
1-2007




              Comfortable limit adjustment and programming             Terminals for one pull-switch or radio control
              of all functions from the ground.                        1-channel available, function programmable:
              Initial rapid limit adjustment in 4 steps,               • On command, the door travels to its OPEN or
              when adjusted the door moves in CLOSE / OPEN               CLOSE position, if a new command would be
              hold to run function.                                      issued during closing, the door re-opens.
              Selectable operating mode:                                 or
              • Hold to run CLOSE / OPEN                               • Step by Step Function
              • Hold to run CLOSE / self-hold OPEN                       OPEN-STOP-CLOSE-STOP-…
              • Self-hold CLOSE / OPEN                                 Intermediate stop position
              Automatic safety-edge detection                          (may be selected ON / OFF):
              and evaluation:                                          • Stop position is free adjustable between final
              • Normally closed 1K2 with testing system                  OPEN and CLOSE position.
              • Normally open 8K2 resistor                             • Automatic closing starts also from intermediate
              • Optical safety edge (e.g. Brand Fraba)                   stop position.
              Automatic closing feature adjustable from                Signal light mode with fore-warning or
              1 to 240 seconds (ON / OFF possible):                    changeover relay contact (freely programmable).
              • The door closes automatically from final open or       Plug-in connection for:
                intermediate stop position after the adjusted time.    • Radio control
              • Timer can be interrupted by triggering of                or
                the photo beam; adjustable function.                   • UBS junction module with 5 ports for fitting
              Slack-rope / pass-door switch contact is available.        UBS accessories e.g. push button,
                                                                         photo-beam etc. (UBS accessories, page 7.77)




            Special functions

              Automatic ground adjustment                              Overload monitoring in open direction:
              to compensate cable extension (slackness) or             • Only for balanced doors, detects any sudden
              subsequent change of ground height.                        changes in balancing behaviour.
              Overrun correction                                       • Self-learning, no reaction by overload monitoring
              to compensate door over running, e.g. due to               when slowly changes in spring tension.
              temperature changes, cable extension, etc.               • Two levels of sensitivity may be adjusted.
              Status and information display                           Direct-Inverter (DU) recognition:
              Counter for program changes                              • Recognised automatically ELEKTROMATEN
              Operations cycle counter (non re-settable)                 with direct inverter (DU).
              Maintenance indicator:                                   • Output speed adjustment by selector switch.
              • Adjustment range: 1,000 to 99,000 cycles               • Soft start and soft stop with automatic adjustment
              • After reaching the adjusted maintenance cycles,          of acceleration and deceleration.
                the selected function will be displayed or changes     • Individual adjustment of acceleration and
                the door operation when service is due.                  deceleration in three steps possible.
              Monitoring of the door operation integrated
              This recognizes any sudden change in the door
              operation (e.g. the door is locked). The digital limit
              switch DES detects any change of movement and
              switches the control panel OFF.
page 7.42




                                                                                                    Subject to measurement and design revisions.
   Connectable accessories TS 970




                                                                           1-2007
                                                                24 V

                                                              External




                           3 x 400 V/N/PE
                           3 x 400 V/PE         230 V
                           3 x 230 V/PE        External
                           1 x 230 V/N/PE



                                                          U
                                                          B
                                                          S




                                                                         page 7.43




Subject to measurement and design revisions.
                                                                                                                    1-2007
        Control panel TS 981


        Control panel with traffic management for GfA ELEKTROMATEN with digital limit switch DES




       Approvals and certificates
       Certified according to DIN EN 12453




   Technical data

          For all GfA ELEKTROMATEN with digital end-limit        Supply voltage: 1x230V/N/PE;
          switch DES.                                            3x230V/PE; 3x400V/N/PE;3x400V/PE
          Up to 3.0 kW motor power                               Control voltage 24V DC




   Housing

          Dimensions W x H x D: 190 x 300 x 115 mm               Live electrical parts covered
          IP65 with direct connection or IP54 with CEE plug      Encl. drilling template and fixing elements
          We recommend the use of an additional cover
          if the panel is to be subject to constant spraying
          with water or installed in the open air (Page 7.82).

                                                                                                                 Blatt 6.11




   Description
                                                                                                                 page 7.51




          Integrated OPEN-STOP-CLOSE push-button                 Connection cable for ELEKTROMATEN
          Available with optional ready-wired CEE plug           from 3 up to 15m.
          and 1m of cable, replaces main switch according        Plug-in connection for spiral cable
          to DIN EN 12453.                                       Emergency stop-button (optional)
          Adjustment settings via selector switch                Key-switch (optional)
          with 7-segment display.                                Latching switch for intermediate stop setting
          Plug-in connections for ELEKTROMATEN                   (optional).




Subject to measurement and design revisions.
            Functions
1-2007




              Comfortable limit adjustment and programming of          Intermediate stop position
              all functions from the ground.                           (may be selected ON / OFF):
              Initial rapid limit adjustment in 4 steps,               • Stop position is free adjustable between final
              when adjusted the door moves in CLOSE / OPEN               OPEN and CLOSE position.
              hold to run function.                                    • Automatic closing starts also from intermediate
              Selectable operating mode:                                 stop position.
              • Hold to run CLOSE / OPEN                               Two relay contacts (freely programmable).
              • Hold to run CLOSE / self-hold OPEN                     Terminals to connect two external push-buttons
              • Self-hold CLOSE / OPEN                                 available.
              Automatic safety-edge detection and                      One-way and two-way traffic control.
              evaluation:                                              Traffic-light management, adjustable: flashing or
              • Normally closed 1K2 with testing system                continuous, fore-warning time of 0 - 40 sec., priority
              • Normally open 8K2 resistor                             to entry or exit.
              • Optical safety edge (e.g. Fraba Brand)                 Air-lock management
              Entrapment evaluation, selectable:                       Inter-locking of two control panels via external
              • NC / NO contact with resistor                          interlocking modules (optional).
              • Optical systems                                        Status monitoring function supplies outputs signals
              • Safety photo-beams                                     via external signal module (optional).
              Automatic closing feature adjustable from 1 to 240       (Two-door position signals / six-status signals)
              seconds (ON / OFF possible):                             With 5 integrated UBS ports
              • The door closes automatically from final open or       for fitting UBS accessories e.g.
                intermediate stop position after the adjusted time.    push button, photo-beam etc.
              • Timer can be interrupted by triggering of              (UBS accessories, page 7.77)
                the photo beam; adjustable function.                   Slot for memory card (MC) for installing or
              Slack-rope / pass-door switch contact is available.      upgrading software with compact flashcards.
              Terminals for two pull-switches or radio control
              1- or 2-channel available, function programmable:
              • On command, the door travels to its OPEN or
                CLOSE position, if a new command would be
                issued during closing, the door re-opens.
                or
              • Step by Step Function
                OPEN-STOP-CLOSE-STOP-…




            Special functions

              Automatic ground adjustment                              Overload monitoring in open direction:
              to compensate cable extension (slackness) or             • Only for balanced doors, detects any sudden
              subsequent change of ground height.                        changes in balancing behaviour.
              Overrun correction                                       • Self-learning, no reaction by overload monitoring
              to compensate door over running, e.g. due                  when slowly changes in spring tension.
              to temperature changes, cable extension, etc.            • Two levels of sensitivity may be adjusted
              RWA function (smoke draining) actuates a compul-         Direct-Inverter (DU) recognition:
              sory door opening, to be used with external smoke        • Recognised automatically ELEKTROMATEN
              alarm systems.                                             with direct inverter (DU).
              Status and information display                           • Output speed adjustment by selector switch.
              Counter for program changes                              • Soft start and soft stop with automatic adjustment
              Operations cycle counter (non re-settable)                 of acceleration and deceleration.
              Maintenance indicator:                                   • Individual adjustment of acceleration and
              • Adjustment range: 1,000 to 99,000 cycles                 deceleration in three steps possible.
              • After reaching the adjusted maintenance cycles,
                the selected function will be displayed or changes
                the door operation when service is due.
              Monitoring of the door operation integrated.
page 7.52




              This recognizes any sudden change in the door
              operation (e.g. the door is locked). The digital limit
              switch DES detects any change of movement and
              switches the control panel OFF.




                                                                                                      Subject to measurement and design revisions.
            GfA – ELEKTROMATEN                                                                                                          Controls/-Functions - Comparing




                            Funktionen                                                TS 956                         TS 958           TS 961      TS 970        TS 981
   LCD Display for Status & Informations                                                    ●                             ●             ●             ●             ●
   Integrated Push - Buttons Open – Stop Close                                              ●                             ●             ●             ●             ●
   External Supply 24V - 150 / 1000mA                                                      ●/-                           ●/-           ●/-           ●/-           -/●
   With 1 m Cable & CEE-Plug                                                                ●                             ●             ●             ●             ●
   Usable for mechanical Limits “NES”                                                       ●                                           ●
   Usable for digital       Limits “DES”                                                                                   ●                         ●             ●
   Limits quick adjustment in only 4 steps                                                                                 ●                         ●             ●
   All adjustments from the control panel                                                                                  ●                         ●             ●
   Operating Mode: Hold to Run 't                                                           ●                              ●            ●            ●             ●
   Operating Mode: Hold to Run L.                                                           ●                              ●            ●            ●             ●
   Operating Mode: Automatic 't                                                             ●                              ●            ●            ●             ●
   Operating Mode: Automatic L.                                                                                                         ●            ●             ●
   Additional Intermediate Position                                                                                                     ●            ●             ●
   Auxiliary Relay Contacts                                                                  1                             1            1            1              2
   Separated signal inputs “Inside – Outside”                                                                                                                      ●
   Contacts: Traffic Light -“Red”                                                                                                       ●            ●             ●
   Contacts: Traffic Light -“Red & Green”- One way                                                                                                                 ●
   Contacts: Traffic Light -“Red & Green”-Priority in Traffic                                                                                                      ●
   Contactable Safety – Edge System: Pneumatic1,20                                                                                      ●            ●             ●
   Contactable Safety – Edge System: Resistance 8,20                                                                                    ●            ●             ●
   Contactable Safety – Edge System: Optical (FRABA)                                                                                    ●            ●             ●
   Pass Door contact                                                                        ●                              ●            ●            ●             ●
   Photo Beam: Closing Area                                                                                                             ●            ●             ●
   Drawing – In safety device                                                                                                                                      ●
   Drawing – !n safety device with integrated evaluation                                                                                                           ●
   Cycle Counter: generally (not reset able)                                                ●                              ●            ●            ●             ●
   Cycle Counter: program changing                                                          ●                              ●            ●            ●             ●
   Cycle Counter: service interval                                                          ●                              ●            ●            ●             ●
   Information: Last two faults                                                             ●                              ●            ●            ●             ●
   Automatic floor adjustment                                                                                                                        ●             ●
   Blocking monitoring                                                                                                     ●                         ●             ●
   Torque control 't                                                                                                       ●                         ●             ●
   Input: “RWA” – for doors with smoke draining function                                                                                                           ●
   Closing by time: adjustable 1- 240 sec.                                                                                              ●            ●             ●
   Speed programming for Motor – Drive “SE 6.65 DU”                                                                                                  ●             ●
   Function: “Pass through a lock”                                                                                                                   ●             ●
   Function: “Expanded pass through a lock”                                                                                                                        *1
   Expanding: By information module                                                                                                                                *2
   Software – Update                                                                                                                                               *3
*1 = Pass through a lock module (SLF) --- *2 = Information module --- *3 = Memory Card MC / SD --- *4 = mit Priority Traffic module

								
To top