SAMPLE OF HVAC COMMISSIONING TEST SHEETS AIR SYSTEMS
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
AHU PERFORMANCE SHEET WITH RETURN AIR
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Model Serial no. Ordered duty l/s Pa MOTOR Manufacturer Frame size Serial no. Power Kw Electrical supply volts / phase / hertz Motor current amps STATIC DETAILS Belt manf. Belt type / size No. of belts Motor pulley dia. mm Motor shaft dia. mm Motor bush Fan pulley dia. mm Fan shaft dia mm Fan bush Pulley centers mm Motor adjustment mm
Ref Date Job ref Sheet OVERLOAD Type Range Setting Fuse Amps Amps Amps MEASURED CURRENT Amps R-Y-B PERFORMANCE Design Actual Total system duty l/s Return air l/s Fresh air l/s Suction static pressure Pa Discharge static pressure Pa External static pressure Pa Total static pressure Pa Fan speed rpm Motor speed rpm WITNESSED i2i Eng. Date: Date: Name: Name: Signature: Signature: **Indicates not stated
QA-A001
of
% l/s l/s l/s Pa Pa Pa Pa rpm rpm
-
* Indicates unobtainable
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
AHU PERFORMANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Model Serial no. Ordered duty l/s Pa MOTOR Manufacturer Frame size Serial no. Power Kw Electrical supply volts / phase / hertz Motor current amps STATIC DETAILS Belt manf. Belt type / size No. of belts Motor pulley dia. mm Motor shaft dia. mm Motor bush Fan pulley dia. mm Fan shaft dia mm Fan bush Pulley centers mm Motor adjustment mm
Ref Date Job ref Sheet OVERLOAD Type Range Setting Fuse Amps PERFORMANCE Design Total system duty Suction static pressure Discharge static pressure External static pressure Total static pressure Fan speed Motor speed
-
QA-A002
of
Amps Amps Amps MEASURED CURRENT R-Y-B Actual l/s Pa Pa Pa Pa rpm rpm l/s Pa Pa Pa Pa rpm rpm %
-
WITNESSED i2i Eng. Date: Name: Signature: Date: Name: Signature:
**Indicates not stated
* Indicates unobtainable
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
PRESSURE DROPS TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving Fresh Pa A B C D E F Supply Deg C.
Ref Date Job ref Sheet
QA-A003
of
G
Fan Discharge Off Cw Coil / Fan Suction Off Bag Filter / On Cw Coil Off Panel Filter / On Bag Filter Mixing Chamber/On Panel Filter Return Air
Return
Pa G
Deg C. Fresh Air
F
E
D
C
B
A
Pa Total External A+B A+F+G
i2i Eng. Date Name Signed Date Name Signed Date Name Signed Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
FAN PERFORMANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Size Serial No. Ordered Duty MOTOR Manufacturer Frame Size Serial No. Power Electrical Supply Motor Current Belt Manf. Belt Type / Size No. of Belts Motor Pulley Di. Motor Shaft Dia. Motor Bush Fan Pulley Dia. Fan Shaft Dia Fan Bush Pulley Centers Motor Adjustmt. Type Range Setting Fuse
Ref Date Job ref Sheet OVERLOAD Amps Amps Amps MEASURED CURRENT amps R-Y-B PERFORMANCE design actual System Volume l/s Suction Static Pressure Pa Discharge Static Pressure Pa External Static Pressure Pa Fan Speed rpm Motor Speed rpm WITNESSED i2i eng. Date: Date: Name: Name: Signed: Signed: Date: Name: Signed: ** indicates not stated
QA-A004
of
l/s
Pa
% l/s Pa Pa Pa rpm rpm
kW volts / phase / hertz amps STATIC DETAILS
mm mm mm mm mm + / - mm
Date: Name: Signed: * indicates unobtainable
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
DIRECT DRIVE FAN PERFORMANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving
FAN Manufacturer Type Size Serial No. Ordered Duty MOTOR Manufacturer Frame Size Serial No. Power Electrical Supply Motor Current 1 PERFORMANCE Total System Duty Suction Static Pressure Discharge Static Pressure External Static Pressure Fan Speed Motor Speed OVERLOAD Type Range Setting Fuse 7 8 9 design -
Ref Date Job ref Sheet
actual l/s Pa. Pa. Pa. rpm rpm
QA-A005
of
% l/s Pa. Pa. Pa. rpm rpm MEASURED CURRENT R Y B
l/s
Pa
2
3
Kw volts / phase / hertz amps 4 5
Amps Amps Amps
DESIGN
6
10
Design Duty Design Velocity
ACTUAL
l/s m/s mm m2 m/s l/s Pa %
L>R in to air flow
Duct Size Duct Area Actual Velocity Actual Duty Static Pressure Percentage of Design
TEST HOLE LOCATION
i2i Eng. Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
TRAVERSE TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving L>R 1 1 2 3 4 5 6 7 8 9 10 i2i Eng. Date Name Signed
Ref Date Job ref Sheet 2 3 4 5 6 7 8 9 10 DESIGN Design duty Design velocity ACTUAL Duct size (mm) Duct area Actual velocity Actual duty Static pressure % of Design COMMENTS
QA-A006
of
l/s m/s
m2 m/s l/s Pa %
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
DOUBLE TRAVERSE TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving L>R 1 2 1 2 3 4 5 6
3
4
5
6
1
2
3
Ref Date Job ref Sheet 4
QA-A007
5
of 6
DESIGN Design Duty Design Velocity ACTUAL Duct Size Duct Area Actual Velocity Actual Duty Static Pressure Percentage of Design i2i Eng. Date Name Signed
l/s m/s mm m2 m/s l/s Pa % Date Name Signed
DESIGN Design Duty Design Velocity ACTUAL Duct Size Duct Area Actual Velocity Actual Duty Static Pressure Percentage of Design Date Name Signed
l/s m/s mm m2 m/s l/s Pa % Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
DRIVE CHANGE TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving Design 1 2 3 4 5 6 7 8 Measure %
Ref Date Job ref Sheet Comments
QA-A008
of
air volume total s.p motor speed fan speed fan pulley dia motor pulley dia motor amperage *take shaft size then refer to bush manufacturers details for any size difference to calculate new required motor pulley size (PD) Q1 PD2 = PD1 x Q2 to calculate power consumption Q2 Q1
3
to calculate max motor pulley given max motor amp
PD2 =
design amp actual amp
PD1
kW 1 = kW 2 x
i2i Eng. Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
AIR BALANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving Design Design Initial Ref Size Area
l/s
Ref Date Job ref Sheet Initial
%
QA-A009
of Comments
Final
Vel - m/s
Final
l/s
Vel - m/s Vel - m/s l/s
%
i2i Eng. Date Name Signed Date Name Signed Date Name Signed Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
ELECTRIC VAV BOX TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving Box Box Box Ref Size Type
Ref Date Job ref Sheet Location Design Design Test Max Min Voltage Volume Volume Min
QA-A010
of Comments
Min
i2i Eng. Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
FAN COIL PERFORMANCE SHEET DIRECT DRIVE
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Model Serial no. Ordered Duty MOTOR Manufacturer Frame Size Serial No. Power Electrical Supply Motor Current Ref Size Area
Ref Date Job ref Sheet PERFORMANCE High Speed Medium Speed Low Speed External Static Pressure Fan speed Motor speed OVERLOAD Type Range Setting Fuse Design l/s l/s l/s Pa rpm rpm Actual
QA-A011
of
%
l/s
Pa
l/s l/s l/s Pa rpm rpm MEASURED CURRENT R Y B
Kw volts / phase / hertz amps Design Design Initial Low Speed Vol-l/s Vel-m/s Vel-m/s l/s %
Amps Amps Amps High Speed l/s %
Medium Speed l/s %
Comments
i2i Engineer Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
FAN COIL PERFORMANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Model Serial no. Ordered Duty MOTOR Manufacturer Frame Size Serial No. Power Electrical Supply Motor Current DRIVE Belt Manf. Belt Type / Size No. of Belts Ref Size Area
Ref Date Job ref Sheet Motor Pulley Dia. Motor Shaft Dia. Motor Bush Fan Pulley Dia. Fan Shaft Dia l/s Pa Fan Bush Pulley Centers Motor Adjustment +/PERFORMANCE Design Volume l/s Kw External Static Pressure Pa. volts / phase / hertz Fan Speed rpm amps Motor Speed rpm OVERLOAD Type Range Amps Setting Fuse Amps Design Design Initial Initial Final Final Vol-l/s Vel-m/s Vel-m/s l/s % Vel-m/s l/s % mm mm mm mm mm mm actual
QA-A012
of
%
l/s Pa. rpm rpm MEASURED CURRENT R Y B
Comment
i2i Engineer. Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
FAN COIL PERFORMANCE SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving FAN Manufacturer Type Model Serial no. Ordered Duty MOTOR Manufacturer Frame Size Serial No. Power Electrical Supply Motor Current Ref Size Area
Ref Date Job ref Sheet PERFORMANCE Volume Fresh Air Return air External Static Pressure Fan speed Motor speed OVERLOAD Type Range Setting Fuse Design l/s l/s l/s Pa rpm rpm Actual
QA-A013
of
%
l/s
Pa
l/s l/s l/s Pa rpm rpm MEASURED CURRENT R Y B
Kw volts / phase / hertz amps Design Design Initial Initial Vol-l/s Vel-m/s Vel-m/s l/s
Amps Amps Amps
%
Final Final Vel-m/s l/s
%
Comment
i2i Engineer. Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
PACKAGE AIR CONDITIONERS SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving
UNIT DATA
Ref Date Job ref Sheet
MOTOR DATA
QA-A014
of
Manufacturer model no. Serial no. Type Fan pulley mfr Fan pulley dia Fan shaft dia no. of belts TEST DATA EVAPORATOR Total air - fan l/s Outle total air l/s External Pa. Total s.p. fan Discharge s.p Suction s.p Outside air l/s Return air l/s Ent. Air db/wb temp Lvg. Air db/wb temp Outside air db/wb Fan r.p.m Voltage Amperage
Design
Measured
Manufacturer kW RPM Volts F.L.C mm Motor pulley mfr mm Motor pulley dia Motor shaft dia TEST DATA COMPRESSOR Manufacturer model no. Serial no. Suction pres' Discharge pres' Crank case hter A Compress'r volts l.p/h.p cutout set'g no.cond'r fans Cond'r fan h.p Cond'r fan volts Cond'r fan amps
Design
mm mm Measured
i2i Engineer Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
ENVIRONMENTALS TEST SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving
Room number / Identification Temperature
Ref Date Job ref Sheet Deg. C Humidity % RH Sound Level dBA Comments
QA-A015
of
i2i Eng. Date Name Signed Date Name Signed Date Name Signed Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
HOOD CONSTRUCTION SIZES SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving Hood A no. mm 1 150x150 2 200x200 3 300x300 4 600x300 5 400x400 6 450x450 7 600x600 8 600x600 9 800x800
B mm 100x100 85 x 85 130x130 260x130 180x180 195x195 260x260 400x400 360x360
C mm 140 220 330 700/740 440 500 700 360 880
D mm 140 170 250 350 330 380 500 540 660
Neck area Extract
m2 factor 0.010 0.0098 0.0075 0.0069 0.017 0.0158 0.034 0.031 0.032 0.029 0.038 0.035 0.0655 0.06 0.162 0.148 0.13 0.118
Ref QA-A016 Date Job ref Sheet of Supply Approx volume range m3/s factor min max 0.0118 0.010 0.040 0.0083 0.007 0.030 0.019 0.015 0.070 0.037 0.03 0.130 0.035 0.03 0.130 0.042 0.035 0.150 0.072 0.060 0.300 0.178 0.200 0.650 0.142 0.120 0.550
C D B A
i2i Date Name Signed
Date Name Signed
Date Name Signed
Date Name Signed
Installation Integrity 2000
H.V.A.C Commissioning Management Tel:- +971 (0) 4 338 4806 Fax:- +971 (0) 4 338 4830
AIR BALANCE SUMMARY SHEET
www.i2ime.com
Contract Client Plant reference Location / area serving
Micromanometer Anemometer Flow hood
Ref Date Job ref Sheet design design initial volume velocity velocity final correction final velocity factor volume
QA-A017
of
ref
size
area
%
%
comments
i2i Eng. Date Name Signed Date Name Signed Date Name Signed Date Name Signed