Docstoc

Installation Instructions

Document Sample
Installation Instructions Powered By Docstoc
					                                                      Installation
                                                      Instructions
                                                      Bradley Modesty
                                                      Modules™ for Wall
                                                      and Column Showers




                                            Table of Contents
                                             Pre-Installation Information . . . . . . . . . . . . . . .2
                                             Care and Cleaning of Stainless Steel . . . . . . . . .2
                                             Wall and Column Shower Layouts . . . . . . . . . .3
                                             Install Floor Anchors . . . . . . . . . . . . . . . . . . . .4
                                             Assemble Pilaster and Post Support
                                             Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
                                             Install Floor Anchors . . . . . . . . . . . . . . . . . . . .5
                                             Install Pilasters and Posts . . . . . . . . . . . . . . . . .5
                                             Install Modesty Module™ Partitions . . . . . . . . .6
                                             Install Head and Curtain Rails . . . . . . . . . . . . .6
                                             Install Shower Seat . . . . . . . . . . . . . . . . . . . . . .7
                                             Complete Installation . . . . . . . . . . . . . . . . . . . .7
               IMPORTANT:
 Check the local codes and ordinances
 in your area for proper location and
 connection requirements. Conformity
 to local codes is the responsibility of
 the installer.
 This installation manual should be filed
 by the building owner’s maintenance
 department.




                                                    P.O. Box 309, Menomonee Falls, WI 53052-0309
215-890; Rev. D; EN 00-341                          Phone: 1-800-BRADLEY FAX: (262) 251-5817
Page 1 of 7                                         http://www.bradleycorp.com
Bradley Modesty Modules™ for Wall and Column Showers
                                                                                                Installation Instructions


Pre-Installation Information
    Overview
    Modesty Modules™ have stainless steel columns, framework and partitions. All units come complete
    with showers, partitions, framework, curtains, robe hooks, and all the necessary attaching hardware.
    Care and cleaning of Stainless Steel
    Periodic and frequent cleaning will greatly prolong the service life of stainless steel equipment and, at
    the same time, maintain a bright surface of pleasing appearance. The amount and frequency of cleaning
    depends on service conditions involved.
         IMPORTANT: Never use ordinary steel wool or steel brushes on stainless steel. Always use
                          stainless steel wool or stainless steel brushes. Do not allow salty solutions to
                          evaporate and dry on stainless steel.
       General cleaning: Ordinary deposits of dirt and grease are quickly removed with soap and water.
       Whenever possible, the metal should be thoroughly rinsed and dried after washing. To get rid of
       tightly adhering deposits, use stainless steel polishing powder. In all cases, rubbing should be in the
       direction of polishing lines.
      NOTE: Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear.
      The use of these cleaners should be avoided.




    Bradley Modesty Module™ Warranty
     Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in
     material and workmanship under normal use and service upon the following terms and conditions:
     1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the
        purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within
        the limitations of this warranty.
     2. The period during which Modesty Module™ components are warranted is one (1) year, measured from
        the date of our invoice.
     3. This warranty does not cover installation or any other labor charges and does not apply to any units
        which have been damaged by accident, abuse, improper installation or improper maintenance.
     4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of
        the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation
        shall not otherwise be liable under any circumstances for incidental, consequential or indirect damages
        caused by defects in the repair or replacement thereof.
     5. This warranty extends only to commercial and institutional purchasers and does not extend to any others,
        including consumer customers of commercial and institutional purchasers.
     6. this warranty is in lieu of all other warranties, express or implied, including any implied warranty of
        merchantability or fitness for a particular purpose or otherwise.




2                                                                  Bradley Corporation • 215-890 Rev. D; EN 00-341
                                                  Bradley Modesty Modules™ for Wall and Column Showers
Installation Instructions


Modesty Module™ Wall and Column Shower Layouts
   NOTE: These illustrations show typical shower room layouts. Your layout may vary from what is shown.

 Modesty Module™ Wall Shower Layout
                                                                   WALL SHOWERS
     HEADRAIL




  CURTAIN
     RAIL




  CURTAIN



            SEAT


                                                                                        WALL BRACKET

                    4” PILASTER


                                                                                        PARTITION
                                  6” PILASTER

                                                  POST                 STIRRUP


  Modesty Module™ Column Shower Layout
                                                                       COLUMN SHOWERS
     HEADRAIL




      CURTAIN
         RAIL


      CURTAIN




                                                                                        PARTITION


         4” PILASTER



                                                                        POST        STIRRUP
                        6” PILASTER

                                          SEAT




Bradley Corporation • 215-890 Rev. D; EN 00-341                                                        3
Bradley Modesty Modules™ for Wall and Column Showers
                                                                                           Installation Instructions


Installation Instructions
    Step 1: Install floor anchors
       1. Install your Bradley shower as instructed on the
          shower installation instructions provided with
          your new shower.
       2. Check dimensions on the layout drawing
          (identified by a "MM" number) you received
          for correct location of pilasters, posts, and
          partitions.
       3. Scribe lines on the floor to indicate the locations
          of the pilasters and posts in relation to the
          showers and/or walls according to the dimensions
          on the layout drawing you received.
    Step 2: Assemble pilaster and post support
    hardware
       1. Using a pilaster floor bracket and a post foot
          angle as templates, locate and mark hole
          locations for the support hardware on the floor
          (refer to drawing received).                            Figure 1
     NOTE: Alternate 4" and 6" pilasters as shown on
     page 3. The shower seat will be mounted to the
     partition attached to the 6" pilaster.
       2. Drill floor holes for the pilasters and posts into the floor.
     NOTE: If you are drilling into concrete, drill 1/4" deeper than the
     length of the anchor. If you are drilling into a tile floor, make sure
     the top of the anchor is below the setting bed.
       3. At each pilaster hole location, secure the hardware compo-
          nents shown in Figure 1.
       4. At each post hole location, secure the hardware components as
          shown in Figure 2.




                                                                                Figure 2




4                                                               Bradley Corporation • 215-890 Rev. D; EN 00-341
                                                      Bradley Modesty Modules™ for Wall and Column Showers
Installation Instructions


Installation Instructions continued . . .
    Step 3: Install stirrups to hold partitions
        1. Using a stirrup as a template, mark the locations for the stirrup screw
           holes on the pilasters and posts. Drill 5/32" diameter holes at the marks.
        2. Fasten the stirrups, shown in Figure 3, to the posts and pilasters
           using the #10 x 1/2" sheet metal screws provided.
        3. For column shower installations, fasten the stirrups shown in Figure
           3 to the column shower's pre-drilled holes using the #10-24 x 1/2"           Figure 3
           self-tapping screws which are in a bag tied to the shower column.
        4. For Modesty Modules fastened to the wall, mark stir-
           rup locations and drill 3/8" diameter 1-1/8" deep holes
           in the wall. Install bracket to wall with lead anchors
           and 1/4" - 20 x 1-1/4" screws provided (see Figure 4).
    Step 4: Install pilasters and posts
       1. Beginning with the first row of Modesty Modules™,
          slip shoes onto the bottom of posts (see Figure 5).
       2. Set posts into position over the post foot angle and fas-      Figure 4
          ten mounting hardware (see Figure 5).
     NOTE: To allow for adjustments, DO NOT tighten screws until Step 5,
     Procedure 4.
       3. Set pilasters into position over the floor bracket and install mount-
          ing hardware but do not tighten screws until Step 5, Procedure 4
          (see Figure 6).
       4. Assemble pilaster shoe around bottom of pilaster and install with
          #14 x 5/8" Phillip head screws provided (see Figure 6).
     NOTE: To allow for adjustments, do not tighten screws.




                                                                                        Figure 5




 Figure 6



Bradley Corporation • 215-890 Rev. D; EN 00-341                                                         5
Bradley Modesty Modules™ for Wall and Column Showers
                                                                                       Installation Instructions


Installation Instructions continued . . .
    Step 5: Install Modesty Module™ partitions
       1. Using a support, set partitions on edge and
          slide into stirrups on posts and pilasters (and
          walls).
       2. Position partition so the spaces on the sides of
          the partition are equal and the partition is
          level.
       3. Make sure the partitions are level and
          plumb. For wall shower installations, install
          notched-out Wall-Saver first. For column
          shower installations, install partitions next to    Figure 7
          the column shower first. See Figure 7 for
          determining partition height. Then mark drill
          hole locations on partitions and drill 5/32" diameter
          holes in the partitions at the marked locations.
       4. Make sure all parts are level and plumb. Fasten the
          partitions to the stirrups (and wall brackets) with
          #14 x 5/8" Phillips head screws (p/n 160-360)
          provided and secure posts and pilasters to floor
          bracket/foot angles.
    Step 6: Install head and curtain rails
        1. Using a pilaster floor bracket and a post foot angle
           as templates, locate and mark hole locations for the      Figure 8
           support hardware on the floor (refer to drawing
           received).
     NOTE: Alternate 4" and 6" pilasters as shown on
     page 2. The shower seat will be mounted to the
     partition attached to the 6" pilaster.
        1. Using the stirrup as a template, mark the
           screw hole locations on rails and drill 5/32"
           holes in marked locations.
        2. Install aluminum head and curtain rails as
           shown in Figure 9. Make sure the headrails
           junction at the corners (see Figure 8).
     NOTE: Before fastening curtain rails, be sure to         Figure 9
     slide eight hooks per curtain (ten for extra-
     strength curtains) into position on the curtain
     rails.




6                                                            Bradley Corporation • 215-890 Rev. D; EN 00-341
                                                    Bradley Modesty Modules™ for Wall and Column Showers
Installation Instructions


Installation Instructions continued . . .
    Step 7: Install shower seat
       1. At the desired location, drill a 5/16" diameter floor hole for
          seat post. Mount the seat to a partition secured to a 6"
          pilaster.
     NOTE: Only one post per seat is provided and is to be centered
     under seat.
       2. Assemble remaining seat post hardware as shown in Figure
          10.
     NOTE: Do not put spacer under post foot angle.
       3. Attach the two seat brackets included to the module parti-
          tion (see Figure 11). Make sure seat brackets are level with
          bracket installed on seat post.
     NOTE: Two seat brackets are to be used for each seat.
       4. For stainless steel seat mounting, drill two #9 (0.196" diameter)
          holes in the bottom of the seat using the bracket on seat post
          as a template.
       5. Assemble seat to seat brackets and post bracket with screws
          provided (see Figure 11).
    Step 8: Complete Installation
       1. Be sure that all hardware is mounted with proper number of
          screws and securely tightened.
       2. Clean the stainless steel, partitions, seats, etc. before use
          (See page 2 for cleaning information).
     NOTE: If these instructions are followed, your Bradley Modesty
     Modules™ will provide years of dependable service. However, if
     these cleaning instructions are not followed, Bradley will not
     accept any responsibility for product failure.
       3. Hang shower curtains on shower curtain hooks installed on
          curtain rails.
                                                                              Figure 10




             Figure 11




Bradley Corporation • 215-890 Rev. D; EN 00-341                                                       7

				
DOCUMENT INFO