Park Plaza Rm Boston Massachusetts FAX WQC APPLICATION REVIEW

Document Sample
Park Plaza Rm Boston Massachusetts FAX WQC APPLICATION REVIEW Powered By Docstoc
					                 10 Park Plaza, Rm. 4260 • Boston, Massachusetts 02116 • (617) 973-7484 • FAX (617) 973-8879

                            WQC APPLICATION REVIEW CHECKLIST



 
The following is needed prior to the review and filing of Water Quality Certification 
permit applications.  
 
                                            Narrative Outline 
1.        Existing Conditions 
2.        Proposed Conditions 
3.        Construction Sequence 
4.        Wetland Impacts 
5.        Wetland Replication (if required) 
6.        Sedimentation Control 
7.        Dewatering 
8.        Storm Water Management 
9.        Fisheries and Wildlife/Natural Heritage Endangered Species/Vernal Pools 
               End Sp           ORW 
10.  Alternative Analysis 
11.  Specifications to be included into the contract 
         Demo 
         Wetland Replication 
         Mussel Survey/Transplant Protocol 
         Vegetation Survey/Transplant Protocol 
      
 
Application & Narrative 
            Use updated application form found on the following DEP website.  
            http://www.mass.gov/dep/water/approvals/ww1011ap.doc 
            Describe the existing site conditions. 
            Describe the proposed site conditions. 
            Describe the proposed activity. 
            Direction of flow of river/stream. 
            Name of river basin. 
            Include English measurements throughout the narrative for permanent and 
            temporary impacts to resource areas. 


                                                     1 of 3
              10 Park Plaza, Rm. 4260 • Boston, Massachusetts 02116 • (617) 973-7484 • FAX (617) 973-8879

                         WQC APPLICATION REVIEW CHECKLIST



        ANY work in the water below the Ordinary High Water (OHW) line, such as 
        riprap placement or dewatering (including temporary measures), is considered 
        to be LUW impact.  The removal and/or construction of the existing 
        abutments/piers will need to be done in the dry.  The dewatering area inside the 
        cofferdam is classified as temporary impact.   
        Describe how the abutments/piers will be removed and constructed. 
        What equipment will be used during demolition and construction?  In particular, 
        will staging be placed in the water/wetlands?
        Describe the temporary and/or permanent impacts to Bordering Vegetated 
        Wetland (BVW), LUW, and measures to minimize and mitigate. 
        Anticipated Construction Sequence – Include when and how the sedimentation 
        controls, cofferdams, method of dewatering, etc. will be implemented.
        Describe the existing and proposed drainage system, with stormwater BMPs.

        Provide, or expand upon, the Alternatives Analysis.  At least three alternatives 
        need to be looked at and discussed. 
        If BVW fill is proposed, then provide a Wetland Replacement Area at a minimum 
        1:1 ratio. 
        If the project requires excavation greater then 100 cubic yards, a dredge WQC 
        (WW 7 or 8) will be required, not a fill WQC (WW 10 or 11).
                 A sediment and chemical analysis is required, since over 100 cubic yards 
                 of dredging is proposed. 
                 Complete the “Historical Parameters” section of the WQC‐dredge 
                 application. 
        Include BVW Delineation Sheets (If available). 
        Include color photos (if available) of resource areas.  Photos from the bridge 
        facing upstream and downstream, as well each quadrant and impact area at 
        abutment/pier locations are desirable. 
        Forward the Response letter from Mass Fish and Wildlife and Mass Natural 
        Heritage and Endangered Species Program (must be within 3 years). 
 
        Forward an electronic copy (in MS Word) of the WQC application and project 
        narrative with revisions. Email –susan.mcarthur@mhd.state.ma.us. 
                                                  2 of 3
            10 Park Plaza, Rm. 4260 • Boston, Massachusetts 02116 • (617) 973-7484 • FAX (617) 973-8879

                       WQC APPLICATION REVIEW CHECKLIST



Construction Plans for WQC Application
       Include a locus map. 
       Include an environmental constraints map (showing Outstanding Resource 
       Waters (ORW), Areas of Critical Environmental Concern (ACEC) and Priority 
       and Estimated Habitat of Rare Species (NHESP). 
       Provide plans showing boundary and location of all BVW, LUW, or Coastal 
       Wetlands. 
       Shade and Label (BVW and/or LUW) the temporary and permanent impacts as 
       well as replication areas (as applicable).  Provide a table (legend) with impact 
       numbers. 
       Add English scalebar to all plans. 
       Illustrate the location of the proposed cofferdam on all plan sheets. 
       Illustrate the location of the sedimentation/erosion control measures on plans. 
       Show and label the Ordinary High Water (OHW) mark as a line on the 
       construction plan, profile, elevation, and longitudinal section. 
       Insert a double arrow indicating the direction of flow & ebb on the locus plan. 
       Show contour lines on side slopes of roadway near bridge. 
       A profile and longitudinal section for the existing and proposed bridge is needed 
       with OHW, and the 10, 50, 100‐year flood elevation shown.  Show datum and 
       low cord elevation (existing vs. proposed) over the waterbody. 
       If a Wetland Replacement Area is required, provide a planting plan with 
       proposed grades, cross section plan, and construction 
       methodology/specifications. 
       If riprap is proposed include a note Riprap (M2.02.2) specifications on plans. 
       Submit 8.5 X 11 or 11 x 17 inch size plan sheets TO SCALE of the construction 
       plan, profile, elevation, and longitudinal section with revisions and/or additions.
 
If you have any questions regarding this Review Check List, please feel free to contact 
Susan McArthur at 617‐973‐7434.




                                                3 of 3