					CHEUNG HING-OCTOPUS Car Park System


CHEUNG HING-OCTOPUS Car Park System Overview
CHEUNG HING-OCTOPUS Car Park System is a simple access control system
(Figure. 1). System integrated with CHEUNG HING-OCTOPUS Access Control
System, Loop-detectors and Car Park Barriers. When a car wants to drive into/out the
car park, the car should stop beside the card reader. At this time the car should be on
the top of the loop-detector that besides the card reader. Loop-detector will send
signal to enable the card reader to read card that is available when the car drives over
the loop-detector (Car reader will disable when loop-detector has not metallic object
detected.). Then driver presents his OCTOPUS card. Card reader will send
OCTOPUS card’s IDs to CHEUNG HING Access Controller. CHEUNG HING
Access Controller checks the Cardholder's status before granting access to this car. If
it is a valid card, barrier will open. Now, the car can go through the barrier and into
the car park. The barrier will close after the car drove over the loop-detector that
located behind/under the barrier.




                                       Figure. 1
The operation of barrier rise and down are controlling by the barrier controller.
Different brands of barrier have different barrier controller and configuration. All of
barrier controllers usually have an input for human control (Rise, Down and Stop).
CHEUNG HING-OCTOPUS Car Park System only connect to barrier-rise input
request barrier rise. CHEUNG HING-OCTOPUS Car Park System is similar to
CHEUNG HING- OCTOPUS Access Control System. Only different in the output
control devices, one is door lock and another is car barrier.
CHEUNG HING-OCTOPUS Car Park System


Logic Flow of CHEUNG HING-OCTOPUS Car Park System


               The system starts, standby status. Card reader disabled.




     When a car drives beside the card       When a people stands beside the card
                 reader.                     reader.


       Loop detector detects metallic
                                                 Loop detector detects nothing.
                 objects.


       Card reader enable. Driver to             Card reader remains disabled.
       present the OCTOPUS card.


                                                        Back to standby
         The driver presents a card


       Card reader reads the card ID.


                  Send to


       Controller checks the card ID.

                 Card Valid                              Card Invalid


    Barrier raise. The car can drive into    Card reader indicates this card is
    the car park.                            invalid and the barrier will not rise.


    Drive through the rear loop detector


       The barrier drops. The system
         returns to standby status.
CHEUNG HING-OCTOPUS Car Park System


CHEUNG HING-OCTOPUS Car Park System Connection Diagram


       Hubs/Switch
                                                                      LAN(CAT 5)
               1 2 3 4 5 6 7 8 9 10   11 12 13 14 15 16 17 18 1 9
                                                                                                                                  Cards are registered at a
                                                                                                                                  central computer installed at
                                                                                                                                  the estate management
                                                                                                                R/W with buzzer
                                                                                                                   module         office, control room…. etc.


                                                                    (RS-232)                            Loop Detector             A car stop drives on the top
  LAN(CAT 5)




                                                                                                                                  of loop detector to enable
                                                                                                                                  Octopus reader. Driver
                                                                                    Bare Reader
                                                                                   (RC-S430C1/1)
                                                                                                                                  presents the OCTOPUS card
                                                                                                                                  on Bare Reader.
                                                                                   I/O Module

                                                                                                                                  Access list resides on the
                                                                                                   Signal Controlling LED         CHEUNG HING Access
                   Cheung                                                                          Signal Controlling Barrier     Controller If a valid card IDs
                    Hing                                                                           Signal Controlling Buzzer
                                                                    (RS-485)                                                      send from Bare Reader, it
                   Access
                  Controller                                                                       Signal Controlling LED         will send a signal to the
                         Address: 1                                                                Signal Controlling Barrier     barrier.
                                                                                                   Signal Controlling Buzzer



                                                                                   I/O Module                                     Barrier raise. The car can
                                                                                                                                  drive into the car park. The
                                                                                                                                  barrier will close after the
                                                                    (RS-232)                                                      car drove over the
                                                                                                        Loop Detector
To Controller 2                                                                                                                   loop-detector that located
                                                                                                                                  behind/under the barrier.
                                                                                    Bare Reader