                 LUX DUAL AC MOTOR CONTROL
                            CARD




           FEATURES
               Direct replacement for BFT LUX DUAL AC non limit, timer control card
               Controls two single phase 220V AC motor with closing, common,
               opening windings and a start capacitor
               Pedestrian opening input
               Infra red beam safety input
               Button or receiver control input
               Gate status indication output for LED display inside the house
               Built in buzzer for programming indication and pedestrian opening
               Programmable motor run time
               Programmable delay time between gates
               Lock control output for master motor
               Selectable and programmable auto-closing time
               Selectable CONDOMINIUM/LOOP mode
               Auxiliary 24V AC output supply for external devices
                                     -2-



TECHNICAL SPECIFICATIONS



POWER SUPPLY VOLTAGE                                  220V AC
MASTER AND SLAVE MOTOR VOLTAGE OUTPUT                 220V AC x 2
MASTER AND SLAVE MOTOR POWER OUTPUT                   900W Max
AUXILIARY OUTPUT VOLTAGE                              24V AC
AUXILIARY OUTPUT CURRENT                              230 mA




CONTROL                    CARD                     INSTALLATION
PROCEDURE
     REFER TO WIRING DIAGRAM PAGE 4 & 5

CON NE CTIONS

PLEASE NOTE: MOTOR COMMON (C) = (N) 220VAC NEUTRAL
            CONTROL COMMON (C) = POSSITIVE (+) 12VDC

           O The
MASTER MOTO R master motor winding is connected:
(MOT 1 ) &   Closing & Capacitor to PLG3 MOT 1 Term.3( CL )
STARTER      Opening & Capacitor to PLG3 MOT 1 Term.1( OP )
CAPACITOR:   Common to PLG3 MOT 1 Term.2( C )




SLAVE MOTOR     The slave motor winding is connected:
( MOT 2 ) &     Closing & Capacitor to PLG5 MOT 2 Term.1( CL )
STARTER         Opening & Capacitor to PLG5 MOT 2 Term.3( OP )
CAPACITOR:      Common to PLG5 MOT 2 Term.2( C )




GATE            Push button, receiver, free exit loop normally open
OPENING         contacts ( N/O ) to PLG2 CONTROL Term.2( BT ) &
                Term.1( C )
PUSH BUTTON/    A receiver [ ET-RX1L/24V ] can be used
RECEIVER/       If a magnetic free exit loop detector [ET-MD99] is used,
FREE EXIT       card must be set to condominium mode.
LOOP
                                     -3-


PEDESTRIAN      Pedestrian key switch or intercom button with normally
OPENING         open contacts ( N/O ) is connected to PLG2 CONTROL
                Term.3( PD ) & Term.1( C )
                This facility opens the gate partially for pedestrians.




INFRA RED       Beams normally closed contacts (N/C) are connected to
BEAM            PLG2 CONTROL Term.4( BM ) & Term.1( C )
                This prevents the gate closing on an object in its path.
                When closing, breaking the beam will make the gate stop
                and open. If not used, this must be shorted




GATE STATUS     An LED can be fitted inside the house for status
LED             display.
INDICATION      LED cathode ( - ) to PLG1 S/AC/* Term.1( S ) &
                anode ( + ) to PLG2 Term.1( C )


                               LED INDICATOR
                        ON                  GAT E OP EN
                        OF F                GAT E C LOS ED
                        FL ASH ING          GAT E MOV IN G
                        SLO W
                        FL ASH ING          GAT E ST OPP ED
                        FAS T




LOCK MOT1       Connect a 12V DC relay coil across PLG2 CONTROL
CONTROL :       Term.5( - to Z ) & Term.1( + to C )
RELAY           A drop-lock or mag-lock can be switched with the relay
SWITCHED        The relay contact rating must match the lock power
(OPTIONAL ET-   required.
RELAY           The lock will activate 1 second before the motors start
MODULE)         moving and stay active while they are moving. When the
                motors stop the lock will deactivate. The relay (N/O)
                contact can be used for a drop-lock and (N/C) contact can
                be used for mag-locks.
                                         -6-

               CON TROL CARD PROGRAMMING

                MOTOR MUST BE SETUP ONTO GATE
          ALL MOTOR WIRING AND LIMITS MUST BE SETUP
         SWITCH ALL CONTROL CARD (DIP) SWITCHES 1-4 OFF


                    POWER ON – BUZZER BEEPS ONCE
             J
      PLACE (J P-PROG) JUMPER ON TWO PINS – BUZZER BEEPS TWIC


   RUN TIME       SET ALL (DIP) SWITCH 1 to 4 OFF
   FOR BOTH       Press & release (PROG/SET BUTTON) – Both Motors 1 & 2
   GATES          will close. When both gates are stopped on brackets and the
                  motors are slipping: Press & release (PROG/SET BUTTON):
                  buzzer will give one long beep.
                  Press & release (PROG/SET BUT.) Both Motors 1& 2 will
                  open. When open position reached press & release
                  (PROG/SET BUT.) gates will stop – Buzzer will give one long
                  beep.
                  Press & release (PROG/SET BUT.) Both Motors 1& 2 will
                  close. When closed position reached press & release
                  (PROG/SET BUT.) gates will stop – Buzzer will give one long
                  beep.



   AUTOCLOSE      SET (DIP) SWITCH 1 ON
   TIME FOR       Press & hold (PROG BUT.) - Buzzer beeps per second.
   BOTH           At required Auto-close time release (PROG/SET BUT.) –
   GATES          Buzzer will give one long beep.
                  SWITCH (DIP) 1 OFF or buzzer will sound continuously


           2.N
1. PEDESTRIANSET (DIP) SWITCH 2 ON
   & AUTO     Press & release (PROG/SET BUTTON) –If not closed already
   CLOSE      Motor 1 will close. When gate is stopped on brackets and the
   TIME ON    motor is slipping: Press & release (PROG/SET BUTTON):
   MASTER     buzzer will give one long beep.
   MOTOR      Press & release (PROG/SET BUT.) Motor 1 will open. When
   ONLY       open position reached press & release (PROG/SET BUT.)
              gate will stop – Buzzer will give one long beep.
              At this position, for Auto close time: Press & hold
              (PROG/SET BUT.): Buzzer will beep per second, when
              required time reached, release button.
              Press & release (PROG/SET BUT.) Motors 1 will close.
              When closed position reached press & release (PROG/SET
              BUT.) gate will stop – Buzzer will give one long beep.

                  SWITCH (DIP) 2 OFF or buzzer will sound continuously
                                                   -7-



            2.
             E
1. DELAY TIME SWITCH (DIP) 3 ON.
   MOT 2       Press & hold (PROG-BUT) –Buzzer beeps per second.
               When required time is reached, release (PROG-BUT): buzzer
               will give one long beep.
               SWITCH (DIP) 3 OFF or buzzer will sound continuously



                REMOVE (JP JUMPER) - BUZZER WILL GIVE ONE
                                LONG BEEP
               SETUP (DIP) SWITCHES TO R EQUIRED SETTINGS




                  REQU IRE D SET TIN GS FO R CON TROL CARD

                 DIPSWITCH SETTINGS
                   1    ON   AUTOCLOSE ON
                   2    ON   LOOP/CONDOMINIUM MODE
                   3    ON   DELAY TIME
                   4    ON   LOCK CONTROL

      1.       AUTOCLOSE (DIP 1 ON)
               This is the time the gate will stay open before auto-closing.
               NB! USE ONLY WITH INFRA-RED SAFETY BEAMS.


      2.       LOOP/CONDOMINIUM/FREE EXIT (DIP 2 ON)
           -   This mode is used for multiple user dwellings and its function is to prevent
               another user operating the gate while one user is in the process of driving
               through the gate.
           -   The gate can only be triggered to open by remote, button or free exit loop and
               not to stop or close.

      3.       DELAY TIME (DIP 3 ON)
           -   This is the delayed time MOT 2 starts opening after MOT 1
           -   On closing MOT 2 starts closing, followed after the delayed time MOT 1

      4.       LOCK CONTROL OUTPUT (DIP 4 ON)
           -   The lock will activate 1 second before MOT 1 activates, timed for 3 seconds
               after the gate starts opening after which it will deactivate.




                                              NB!
      Auto-close should only be used with an infra-red beam for
      safety so that the gate does not auto-close onto an object
                            unsupervised.
                                             -8-



                            FAULT FIND ING
                      220V AC L UX GATE MOTORS
SYMPTOM                        CAUSE                          ACTION
Motor does not move when       Button input jammed closed     Wires shorted or button
button is pressed.                                            stuck
                               Beam (BM) input open.          Replace faulty Beam or sort
                               Must be (N/C)                  out sort connection to Beam
                                                              or input wire broken.
Motor does not turn when       Motor too hot, thermal cut-    Wait for motor to cool.
button is pressed, but card    out switch
relays are operating and
there is voltage at motor      Motor faulty.                  Replace motor.
terminals.                     Motor capacitor faulty.        Replace capacitor.
Both motors or only            Button or Pedestrian input     Check Button or Pedestrian
MOT 1 (pedestrian) opens       wiring or switch shorted or    wiring and switch.
and closes intermittently.     intermittent
                               Induced voltage on             Wire up a relay interface
                               pedestrian or button long      and use contacts across
                               line input.                    pedestrian or button input.
Gate opens but does not        Auto close not selected.       Set auto-close.(DIP 1 ON)
auto close.                    Beam input open                Beam or wiring faulty
Motor hums with gate in        Gate jammed                    Free gate from snagging or
closed or open position but                                   obstacles
does not move the gate
Auto-close time too long or    Auto close not programmed      Re-program auto-close
short.                         correctly.
Gate will not respond to       Card set to condominium        Set CONDO (DIP 2 OFF)
button while opening or        mode.
while closing, will stop and
open after button pressed
Both or one gate auto open     Both or one motor wired        Swap motors forward and
instead of auto closing.       incorrectly.                   reverse winding
Motor control card does not    Main fuse blown.               Replace with 5A fuse.
respond to button. Power       No 220VAC supply               Check supply, wiring, fuse
LED OFF.                       Card faulty                    Contact supplier
Motor control card does not    Card locked up.                Switch power OFF, wait
respond to button. Power                                      then switch ON.
LED ON.                                                       Replace with 5A fuse.
                               Interference on long wire to   Wire a relay interface.
                               button                         Connect the contacts to the
                                                              control card inputs and the
                                                              button to the coil
                               Short on button.               Remove and test at card
                                                              button input.
                               Card faulty                    Contact supplier
WARRANTY: All goods manufactured by G&C Electronics cc T/A E T Systems carry a 12 month
factory warranty from date of invoice. All goods are warranted to be free from faulty
components and manufacture. Faulty goods will be repaired or replaced at the                   sole discretion
of E T Systems, free of charge. This warranty is subject to the goods being returned to the
premises of ET Systems. The carriage of goods is for the customers account. This warranty is only
valid if the correct installation and application     of goods, as laid out in the applicable
documentation accompanying said goods, is adhered to. All warranty claims must be
accompanied by the original invoice.


RETURN OF GOODS: The return of goods for exchange or credit will only be valid for 30 days
from purchase date and, shall only take place by prior arrangement with authorized personnel
at E T Systems. E T Systems reserves the right to refuse the return of said goods or to levy a 10%
handling fee on goods correctly supplied. Credit will only validate          on the issue of an official E T
Systems credit note. All goods returned for credit or exchange will be subjected to a QA re               -
evaluation before being accepted. All returns must be accompanied by the original invoice.

Cheque, Electronic fund transfers or dir ect deposits: -
Bank guaranteed cheques will only be accepted by prior arrangement with management.
Electronic fund transfer is accepted, however goods purchased by either cheque or EFT will
only be released on clearance of funds into the G& C Electronics     bank account. (This can take
up to 14 working days in the case of cheques)
The above clearance approval will also apply to direct deposits whether cheque or cash.

								
To top