Solar Neighbourhoods Eligible Solar Thermal Hot Water Systems and
Document Sample


March 2009
Solar Neighbourhoods Eligible Solar Thermal Hot Water Systems and Contractors
Supplier Manu- System Collector Collector Freeze No. of Total Tank Size Peak Warranty**
facturer Model Model Type Protection Collec- Collector performance (years, minimum)
Type tors Area with 225
(Gross) L/day hot
water load*
(m2) (L) (kWh/yr) Collector Tank Balance Labour
of
System
CC Solar Inc. CC Solar CC 47-15 CC 47-15 Evacuated Drainback 1 5.33 300 2000 10 5 1 1
7 Farmington Crescent Tube System
Toronto , ON M1S 1E9
Tel: 647-988-5886
info@ccsolar.ca
www.ccsolar.ca
Down-To-Earth Solar EnerWorks EW1-1C11 Residential Glazed Flat Closed 1 2.87 181 1400 10 6 2 1
Power Inc. (1 COL-4x8- Plate Loop
112 Castlewood Road Collector TL-SG1 (Antifreeze)
Toronto, ON M5N 2L4 System)
Tel: 905-642-3858
info@dtesolar.ca
www.dtesolar.ca
Down-To-Earth Solar EnerWorks EW2-1C11 Residential Glazed Flat Closed 2 5.74 270 2300 10 6 2 1
Power Inc. (2 COL-4x8- Plate Loop
(see above) Collector TL-SG1 (Antifreeze)
System)
EcoGeneration Home EnerWorks EWRA1- Residential Glazed Flat Closed 1 2.87 272 1400 10 6 2 1
Services TEC/TEM COL-4x8- Plate Loop
The Home Depot (1 TL-SG1 - (Antifreeze)
1000 Gerard St. East Collector SD-10
Toronto, ON System)
Tel: 416-992-1603
www.ecogeneration.ca
info@ecogeneration.ca
EcoGeneration Home EnerWorks EWRA2- Residential Glazed Flat Closed 2 5.74 272 2300 10 6 2 1
Services TEC/TEM COL-4x8- Plate Loop
(see above) (2 TL-SG1 - (Antifreeze)
Collector SD-10
System)
1
Supplier Manu- System Collector Collector Freeze No. of Total Tank Size Peak Warranty**
facturer Model Model Type Protection Collec- Collector performance (years, minimum)
Type tors Area with 225
(Gross) L/day hot
water load*
(m2) (L) (kWh/yr) Collector Tank Balance Labour
of System
Glenbarra Energy EnerWorks EWRA2- COL-4x8-TL- Glazed Flat Closed 2 5.74 272 2300 10 6 2 1
1090 Aerowood Drive, TEC/TEM SG1-SD-10 Plate Loop
Unit 1 (2 Collector (Antifreeze)
Mississauga, ON System)
L4W 1Y5
Tel: 905-624-8669
info@glenbarraenergy.ca
www.glenbarraenergy.ca
Skyline Solar Energy Linuo U1521 U1521 Evacuated Closed 2 4.64 300 1700 10 5 5 1
175 West Beaver Creek Paradigma Tube Loop
Rd., Unit 32 (Antifreeze)
Richmond Hill, ON
L4B3M1
Tel: 905-597-6225
Toll free: 1-866-397-3268
info@skylinesolarenergy.
com
http://skylinesolarenergy.
com
Solar Ontario.com Ltd. Viessmann Closed Vitosol 200 F Glazed Flat Closed 2 5.04 299 2400 10 8 2 2
1290 Speers Rd. Unit Loop SV2 Plate Loop
#14 (Antifreeze)
Oakville, ON L6L 2X4
Tel: 905-845-2433
info@solarontario.com
www.solarontario.com
Solar Ontario.com Ltd. Thermo TDL Solar S32 Glazed Flat Closed 2 5.92 272 2300 10 6 2 2
(see above) Dynamics Boiler Plate Loop
(Antifreeze)
2
Supplier Manu- System Collector Collector Freeze No. of Total Tank Size Peak Warranty**
facturer Model Model Type Protection Collec- Collector performance (years, minimum)
Type tors Area with 225
(Gross) L/day hot
water load*
(m2) (L) (kWh/yr) Collector Tank Balance Labour
of System
Solar Ontario.com Ltd. Thermo Seasonal GP-32 Glazed Flat Seasonal 2 5.92 272 1500 10 6 2 2
(see previous page) Dynamics Direct Plate Usage Only
Circulation
System
Solar Ontario.com Ltd. Thermo Thermo GP-32 Glazed Flat Drainback 2 5.92 272 2300 10 6 2 2
(see previous page) Dynamics Dynamics - Plate System
Drain Back
Solsmart Energy Thermo Thermo G32-P Glazed Flat Drainback 2 5.96 270 2300 10 8 1 1
Solutions, Inc. Dynamics Dynamics - Plate System
36 Woodington Ave Drain Back
Toronto, ON M4C3J3
Tel: 416-876-2376
info@solsmart.com
www.solsmart.com
Solsmart Energy EnerWorks EWRA2- Residential Glazed Flat Closed 2 5.74 270 2300 10 8 2 1
Solutions, Inc. E80 COL-4x8-TL- Plate Loop
(see above) SG1 (Antifreeze)
Voltaire Power Viessmann Viessmann Vitosol 200 F Glazed Flat Closed 2 5.04 287 2400 10 6 1 2
2 Matilda St. Type 1 SV2 Plate Loop
Toronto, ON M4M1L9 - Stand (Antifreeze)
Tel: 416-407-0989 Alone
miles.mcdonald@
voltairepower.com
www.voltairepower.com
Voltaire Power Viessmann Viessmann Vitosol 200 F Glazed Flat Closed 2 5.04 300 2400 10 6 1 2
(see above) Type 2 - for SV2 Plate Loop
Boiler (Antifreeze)
3
*An average family of 4 uses roughly 225 litres / day. Peak performance in terms of heat output is based RETScreen modelling of each system given no shading,
south-facing installation (azimuth = 0), and a 45 degree sloped mount.
**Supplier conditions may apply - contact supplier for complete warranty details
List current as of March 18, 2009.
Look for the Solar Neighbourhoods
Eligible symbol on suppliers’
materials
www.solarneighbourhoods.ca