VMware Capacity Planner
Richard Stinton
Specialist Systems Engineer, EMEA Channels
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward…
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward…
What is VMware Capacity Planner?
• A service offering from VMware & its trained Partners • Provides a report on the likely consolidation ratio achievable with VI3
– Analyses customer servers (Inventory & Performance) using Microsoft APIs
• No agent required • Captures peaks & troughs in workload activity
– Customers choice of ESX hosts
• From HCL list
What is VMware Capacity Planner?
Comprehensive Plan
Assess
- What capacity do I have and how well am I using it?
Infrastructure Inventory Performance Measurement Capacity Utilization Metrics
•
•
Discover
Visualize
Infrastructure Discovery
Plan – How much capacity do I really need and what are my options to get there?
Capacity Utilization Analysis Industry Benchmarking / Comparisons Capacity Forecasting / Needs Assessment Identify Opportunities / Alternatives
• •
Consolidate Expand
iw
Industry Benchmark Data
Decide – How do I decide which is (are) the best option(s) for me?
Define / Apply Success Criteria Scenario Modeling / What-if Analysis Industry Benchmarking / Scoring Select Optimal Alternative(s)
( > 4B records and growing!) • •
Virtualize Procure
Monitor– How can I continue to run everything better and last longer?
Set Benchmarks / Thresholds Anomaly Detection / Alerts Infrastructure Capacity Reporting Ongoing Capacity Planning Recommendations
• •
Maintain Change
What is VMware Capacity Planner?
Capacity Planner Dashboard
Web
Infrastructure Assessments
Capacity Planning
Server Consolidation
Industry Data
Hosted Secure Site
Information Warehouse
Data Analyzer
Data Upload
HTTPS Agent-less Data Collection
Client IT Environment
Data Manager
Discovery Performance Inventory Data Synch
Client Site
Data Collector
Utilisation
Processor Summary
Trending during project
VMware Capacity Planner
VMware Capacity Planner
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward…
Trained Capacity Planner partners in EMEA
180 160 140 120 100 80 60 40 20 0 Q2 FY06 Q1 FY07
Number of assessments delivered in EMEA
250
200
150
100
50
0 Q2 FY06 Q3 FY06 Q4 FY06 Q1 FY07
Servers assessed per quarter in EMEA
25000
20000
15000
10000
5000
0 Q2 FY06 Q3 FY06 Q4 FY06 Q1 FY07
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward…
PDSA • Provides veterinary care for sick & injured pets of people in need • Largest private employer of vets and nurses in Europe
PDSA • Existing dual-site Data Centre, separated by about 300m • 50 servers running Windows and Red Hat
– Locally attached disk – Need for Disaster Recovery/High Availability – Need for reduced power/cooling costs
• Engaged Phoenix to carry out CP assessment
PDSA
* Industry average 6-8%
PDSA
• CP assessment suggested between 8:1 and 15:1 consolidation possible
– 6 x Dell 1955 (2 x dual-core, 16Gb) – 3 x Dell 6850 (4 x dual-core, 32Gb)
• PDSA purchased
– 6 x Dell 2950 (2 x quad-core, 16Gb) – EMC CX320 replicated SAN – IP infrastructure already in place
PDSA
• Benefits of Capacity Planner for PDSA
– Provided ‘sanity check’ on design
• Provided data to show the utilisation of current systems • Helped with choice of ESX server(s)
– Shortened decision making process from 12 months to 3 months
Brintons
• Manufacturer of fine carpets
Brintons
• Business issues
– Relocation of computer room – Need for secondary site for DR/HA
Brintons
• Assessment carried out by Esteem • 53 servers assessed • Considered HP & IBM servers
– HP DL385 (2 x 2.8 GHz AMD d/c, 24Gb) – IBM x440 (2 x 2.4GHz Intel d/c, 24Gb)
Brintons
Brintons
• Decided to go with IBM and switched to Triangle • Purchased
– 5 x IBM 3850 (4 x 3GHz Intel d/c, 16Gb)
• 3 in production, 2 in DR
– IBM DS4700 replicated SAN across dual site
• CP provided reassurance and supporting information about the VMware solution
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward
Capacity Planner 2.5
• Available since December • Key new features
– – – – – – – – – Faster Windows Discovery Automatic collector update Remote configuration of collector(s) Drag and drop of servers to groups Scenario builder wizard Duplicate scenarios Notifications Improved role management Improved Support Dashboard
Capacity Planner 2.5 - Tips & Tricks
• • • • • Use XP or W2K in preference to W2K3 Ensure locale set to US-English Inventory of ‘Chassis’ to test connection Inventory groups of servers at a time Check if authentication needed for Web Proxy (Data Sync) • Remember to disable Discovery on scheduler! • Archive data until you are happy that data is getting through to the IW
Resources available
http://mylearn1.vmware.com
Updated for CP 2.5
Resources available
Suggested values for Consolidation Scenarios
Email for a copy: rstinton@vmware.com
Agenda
• • • • • What is VMware Capacity Planner? Capacity Planner EMEA Update Case Studies Capacity Planner 2.5 tricks and tips Looking forward
Looking forward
• Capacity Planner 2.6*
– Slated for Q3 2007 – Green Power initiative – VM configuration recommendations – Automatic production of BCE report
* Usual VMware caveats on futures
Looking forward
• Capacity Planner 3.0
– Major release – Stated for Q2 2008 – Input welcome
Questions?