Feeder Schedule

Reviews
Shared by: The Vet Lives
Stats
views:
3
rating:
not rated
reviews:
0
posted:
2/12/2009
language:
English
pages:
0
FOUR-WIRE FEEDER SCHEDULE FEEDER NAME 20-4 30-4 40-4 60-4 70-4 100-4 125-4 150-4 175-4 200-4 225-4 250-4 300-4 350-4 400-4 450-4 500-4 600-4 700-4 800-4 1000-4 1200-4 1600-4 2000-4 2500-4 WIRE SIZE #12 #10 #8 #6 #4 #2 #1 #1/0 #2/0 #3/0 #4/0 #250 MCM #350 MCM #400 MCM #500 MCM (2) #4/0 (2) #250 MCM (2) #350 MCM (2) #500 MCM (2) #600 MCM (3) #400 MCM (3) #600 MCM (4) #600 MCM (5) #600 MCM (6) #600 MCM GROUND WIRE SIZE #12 #10 #10 #10 #8 #8 #6 #6 #6 #6 #4 #4 #4 #2 #2 (2) #1 (2) #1 (2) #1 (2) #1/0 (2) #1/0 (3) #2/0 (3) #3/0 (4) #4/0 (5) #250 MCM (6) #350 MCM CONDUIT SIZE 3/4" 3/4" 1" 1 1/4" 1 1/4" 1 1/4" 1 1/2" 2" 2" 2" 2 1/2" 2 1/2" 3" 3" 3 1/2" (2) 2 1/2" (2) 2 1/2" (2) 3" (2) 3 1/2" (2) 3 1/2" (3) 3 1/2" (3) 3 1/2" (4) 3 1/2" (5) 3 1/2" (6) 3 1/2" 208V MAX. 480V MAX. LENGTH LENGTH 98' 227' 109' 250' 123' 285' 128' 295' 169' 390' 176' 406' 171' 394' 182' 420' 182' 418' 192' 443' 203' 468' 202' 466' 211' 487' 194' 450' 191' 442' 203' 468' 202' 466' 210' 487' 219' 505' 207' 478' 205' 474' 207' 478' 207' 478' 207' 478' 199' 459' THREE-WIRE FEEDER SCHEDULE FEEDER NAME 20-3 30-3 40-3 60-3 70-3 100-3 125-3 150-3 175-3 200-3 225-3 250-3 300-3 350-3 400-3 450-3 500-3 600-3 700-3 800-3 1000-3 1200-3 1600-3 2000-3 2500-3 WIRE SIZE #12 #10 #8 #6 #4 #2 #1 #1/0 #2/0 #3/0 #4/0 #250 MCM #350 MCM #400 MCM #500 MCM (2) #4/0 (2) #250 MCM (2) #350 MCM (2) #500 MCM (2) #600 MCM (3) #400 MCM (3) #600 MCM (4) #600 MCM (5) #600 MCM (6) #600 MCM GROUND WIRE SIZE #12 #10 #10 #10 #8 #8 #6 #6 #6 #6 #4 #4 #4 #2 #2 (2) #1 (2) #1 (2) #1 (2) #1/0 (2) #1/0 (3) #2/0 (3) #3/0 (4) #4/0 (5) #250 MCM (6) #350 MCM CONDUIT SIZE 3/4" 3/4" 3/4" 1" 1 1/4" 1 1/4" 1 1/2" 2" 2" 2" 2 1/2" 2 1/2" 2 1/2" 3" 3 1/2" (2) 2 1/2" (2) 2 1/2" (2) 2 1/2" (2) 3 1/2" (2) 3 1/2" (3) 3" (3) 3 1/2" (4) 3 1/2" (5) 3 1/2" (6) 3 1/2" 208V MAX. 480V MAX. LENGTH LENGTH 98' 227' 109' 250' 123' 285' 128' 295' 169' 390' 176' 406' 171' 394' 182' 420' 182' 418' 192' 443' 203' 468' 202' 466' 211' 487' 194' 450' 191' 442' 203' 468' 202' 466' 210' 487' 219' 505' 207' 478' 205' 474' 207' 478' 207' 478' 207' 478' 199' 459' TWO-WIRE FEEDER SCHEDULE FEEDER NAME 20-2 30-2 40-2 60-2 70-2 100-2 125-2 150-2 175-2 200-2 225-2 250-2 300-2 350-2 400-2 450-2 500-2 600-2 700-2 800-2 1000-2 1200-2 1600-2 2000-2 2500-2 WIRE SIZE #12 #10 #8 #6 #4 #2 #1 #1/0 #1/0 #2/0 #4/0 250 MCM 350 MCM #400 MCM #500 MCM (2) #4/0 (2) #250 MCM (2) #350 MCM (2) #500 MCM (2) #600 MCM (3) #400 MCM (3) #600 MCM (4) #600 MCM (5) #600 MCM (6) #600 MCM GROUND WIRE SIZE #12 #10 #10 #10 #8 #8 #6 #6 #6 #6 #4 #4 #4 #2 #2 (2) #1 (2) #1 (2) #1 (2) #1/0 (2) #1/0 (3) #2/0 (3) #3/0 (4) #4/0 (5) #250 MCM (6) #350 MCM CONDUIT SIZE 3/4" 3/4" 3/4" 3/4" 1" 1 1/4" 1 1/4" 1 1/2" 1 1/2" 1 1/2" 2" 2" 2 1/2" 2 1/2" 2 1/2" (2) 2" (2) 2" (2) 2 1/2" (2) 2 1/2" (2) 3" (3) 2 1/2" (3) 3" (4) 3" (5) 3" (6) 3" 208V MAX. 480V MAX. LENGTH LENGTH 98' 227' 109' 250' 123' 285' 128' 295' 169' 390' 176' 406' 171' 394' 182' 420' 182' 418' 192' 443' 203' 468' 202' 466' 211' 487' 194' 450' 191' 442' 203' 468' 202' 466' 210' 487' 219' 505' 207' 478' 205' 474' 207' 478' 207' 478' 207' 478' 199' 459' NOTES: 1. Conduits smaller than 3" may be upgraded to the next larger size when used for underground installations or long runs. 2. Conduit sizes indicated are minimum recommended sizes, and may be increased for long circuits, or where multiple bends are necessary. 3. The feeder name represents its base ampacity and the number of wires (not including ground). 4. The base ampacity indicated in the feeder name does not account for voltage drop, fault current or temperature 5. All feeders for 120/208V panelboards with isolated ground (IG) bus shall include a separate IG conductor tied to the IG bus. 6. The rating of the overcurrent protection device may be lower, but not higher, than the rating of the feeder that it protects. 7. Maximum limits on the number of turns and conduit length should be verified for all underground installations. 8. Maximum feeder length is the length that produces a 3% voltage drop at the specified voltage, when the load is at the full ampacity of the feeder, and has a power factor of 90%. 9. Maximum feeder length does not apply if the feeder is sized for voltage drop rather than ampacity.

Related docs
bird feeder
Views: 0  |  Downloads: 0
CONFESSIONS OF A BOTTOM FEEDER
Views: 1  |  Downloads: 0
CONFESSIONS OF A BOTTOM FEEDER
Views: 2  |  Downloads: 0
powder filling with an auger feeder
Views: 0  |  Downloads: 0
Other docs by The Vet Lives
Emancipation Proclamation info
Views: 187  |  Downloads: 0
Sale of business with real and personal property
Views: 224  |  Downloads: 5
Exercise of Option to Purchase Real Estate
Views: 380  |  Downloads: 6
Goodwill
Views: 244  |  Downloads: 2
Employer as lessor
Views: 214  |  Downloads: 0
ajij
Views: 124  |  Downloads: 0
Amendment to Contract 2
Views: 206  |  Downloads: 1
ajij[0]
Views: 129  |  Downloads: 0
Chapter 13 bankruptcy
Views: 292  |  Downloads: 7
Vermont articles of incorporation nonprofit
Views: 267  |  Downloads: 1