TesT sysTem for ConduCTed and radiaTed immuniTy by ecj13059

VIEWS: 30 PAGES: 12

									                           nsG 4070
TesT sysTem for ConduCTed and
radiaTed immuniTy




                                         The NSG 4070, successor of the NSG 2070, is a multifunctional EMC immunity test system. Its large fre-
                                         quency range from 9 kHz to 1 GHz and its modular set-up using internal or external amplifiers enable a
                                         large variety of applications including tests according to IEC 61000-4-6, various BCI applications as well as
                                         signal generator and power meter for test systems as per IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21
                                         and many other applications. The powerful and easy to use firmware makes the NSG 4070 independent
NSG 4070                                 from an external PC and control software, however it can also be remote controlled for system operation.
                                         A state-of-the-art data transfer of test and measurement data for documentation is provided by USB
                                         stick to be plugged into the front panel.




  Integrated signal generator 9 kHz to      External access to          3 power meter            5.7“ color display,          Hard keys for
  1 GHz                                     signal generator output     inputs                   easy to use firmware         important functions
                                            and power amplifier
  3 power meter inputs 9 kHz to             input and output
  1 GHz
  Integrated power amplifier module
  for different applications
  Multiple EUT monitoring options
  5,7“ TFT color display
  Internal, menu-based control soft-
  ware
  Basic remote control software and
  report generator included




                                            User port for 4 TTL         Analog, digital and      10 MHz reference for         Remote control via
                                            inputs and 4 TTL outputs    optical monitoring       synchronisation, Trigger     RS232, LAN or USB
                                            and supply voltages for     inputs for extensive     input for external con-
                                            individual monitoring       EUT monitoring           trol of measurement
                                            and control applications    options                  routines




82-253290 E02 March 2010
2                        nsG 4070
    TesT sysTem for ConduCTed and radiaTed immuniTy




                                    Technical specifications

                                    Generator

                                     RF
                                     Frequency range:                9 kHz – 1 GHz
                                     Resolution:                     1 Hz
                                     Reference frequency:            10 MHz Reference output

                                     RF Level
                                     Level range:                    -60 dBm to +10 dBm
                                     Resolution:                     0.1 dB
                                     Settling time:                  10 ms

                                     Amplitude modulation
                                     Modulation depth:               0 – 100%
                                     Modulation frequency range:     1 Hz – 50 kHz
                                     Frequency resolution:           1 Hz

                                     Pulse modulation
                                     Rise / fall time (10% / 90%):   < 1 µs
                                     Modulation frequency range:     1 Hz – 50 kHz
                                     Frequency resolution:           1 Hz
                                     Duty cycle:                     10% to 90%

                                     External modulation
                                     Delay time:                     < 1 µs / 180°
                                     Period:                         min. 20 µs
                                     Pulse width:                    min. 10 µs



                                    Power meter

                                     Frequency range:                9 kHz – 1 GHz
                                     Linear measurement range
                                     channel 1:                      -15 dBm to +27 dBm
                                     channel 2,3:                    -25 dBm to +20 dBm
                                     Max. input/no damage
                                     channel 1-3:                    +28 dBm
                                     Noise level:                    >6 dB below the measurement range
                                     Input return loss:              >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
                                     Connector:                      BNC socket, 50 Ω




    NSG 4070 datasheet
                           nsG 4070                                                                                                  3

TesT sysTem for ConduCTed and radiaTed immuniTy




                                      Power meter (continued)

                                       Accuracy 150 kHz to 1 GHz, 10 to 30°C
                                       channel 1 to 3:                typ. <0.5 dB
                                       channel 1, below 10 MHz:       range >25 dBm typ. <1.5 dB
                                       channel 2 and 3, below 10 MHz: range >17 dBm typ. <1.5 dB




                                      Power amplifier

                                      Nominal output power:          20 W                  30 W                75 W

                                      Frequency range:              150 kHz – 230 MHz      150 kHz – 230 MHz   150 kHz – 230 MHz

                                      Input impedance:              50 Ω                   50 Ω                50 Ω

                                      Output impedance:             50 Ω                   50 Ω                50 Ω

                                      Input return loss:            min. 10 dB             min. 10 dB          min. 10 dB

                                      Output return loss:           nominal min. 9.5 dB, nominal min. 9.5 dB, nominal min. 9.5 dB,
                                                                    0 dB without damage 0 dB without damage 0 dB without damage

                                      Gain:                         min. 46 dB             min. 46 dB          min. 50 dB

                                      Gain flatness:                 max. +/- 3 dB          max. +/- 3 dB       max. +/- 3 dB

                                      Saturated output power:       min. 43 dBm            min. 45 dBm         min. 48.75 dBm

                                      Max. input power linear       < -3.5 dBm             < -1.5 dBm          < -3 dBm
                                      without damage:               max. +10 dBm           max. +10 dBm        max. +10 dBm

                                      2nd harmonic distortion       typ. < -30 dBc         typ. < -30 dBc      typ. < -35 dBc
                                      at nominal output power:

                                      3rd harmonic distortion       typ. < -20 dBc         typ. < -20 dBc      typ. < -18 dBc
                                      at nominal output power:




82-253290 E02 March 2010
4                        nsG 4070
    TesT sysTem for ConduCTed and radiaTed immuniTy




                                    Test and measurement routines
                                    Firmware: Generator mode

                                     Sweep:                        frequency sweep, level sweep
                                     Modulation:                   AM, AM PC (peak conservation), pulse modulation and external
                                     Others:                       free parameter setting from 9 kHz to 1 GHz, high power mode
                                                                   using power amplifier




    Firmware: Main generator menu   Firmware: Immunity mode

                                     Level:                        constant or slope test levels, max test levels depending on power
                                                                   amplifier, test routine for IEC 61000-4-6 level 1 to 3 and X up to
                                                                   30 V EMF, for BCI tests levels in mA or dBµA
                                     Test methods IEC 61000-4-6:   CDN, EM clamp, current clamp and direct injection, clamp injection
                                                                   with test level control using monitoring probe
                                     Test methods BCI:             substitution method with optional use of the monitoring probe,
                                                                   closed loop method with power limitation (factor adjustable)
                                     Sweep:                        frequency sweep, sweep function linear, steps per decade, percen-
                                                                   tal and as requested in ISO 11452
                                     Modulation:                   AM, AM PC (peak conservation), pulse modulation, external or
                                                                   mixed (e.g. 1 kHz AM internal modulated with 1 Hz PM external)
                                     EUT monitoring:               individual configuration of the ports, function to check or prepare
                                                                   the EUT monitoring, display of EUT monitoring results during the
    Firmware: Immunity test setup                                  test, in the result file and in the test report
                                     Calibration:                  test set-up and monitoring probe calibration, display, store
                                                                   and recall function of calibration files (limitation of file numbers only
                                                                   by the disk space, typical >340 files)
                                     EUT threshold search:         test interrupt for manual or automatic change of frequency or stress
                                                                   level
                                     Store and recall:             store and recall function of test configurations, calibration results
                                                                   and test results (number of files is only limited by the disk space,
                                                                   typical >340 files), supports USB sticks
                                     Component check:              quick check of system components, e.g. cable, attenuator max.
                                                                   52 dB/ 54 dB/ 58 dB attenuation for 20 W/ 30 W/ 75 W amplifier,
                                                                   max. +16 dB gain at 27 dBm output level
                                     Additional features:          free parameter setting from 9 kHz to 1 GHz, supports external
                                                                   power amplifier, RF switch SW 4070, monitoring probe MD 4070,
                                                                   directional coupler and attenuator
    Firmware: Calibration result




    NSG 4070 datasheet
                           nsG 4070                                                                                                            5

TesT sysTem for ConduCTed and radiaTed immuniTy




                                      Windows software

                                       General:                       The windows software includes the firmware functionality. The
                                                                      following additional features are available see below. The software
                                                                      allows the use of the report generator and all post processing
                                                                      features without the remote connection to the NSG 4070.
                                       Remote control:                remote control of NSG 4070 via LAN, USB or RS232
                                       Data transfer:                 transfer between NSG 4070 and PC via LAN connection or with USB
                                                                      stick

Software: Generator menu


                                      Windows software: Generator mode

                                       Display:                       power meter display (units dBm, V, dBµV) with reference value
                                                                      setting, min./max. display and export to a log file (frequency,
                                                                      time, power), EUT monitoring display
                                       Single step mode:              synchronized frequency sweep with power measurement, output as
                                                                      graph and log. file (application: scalar analysis on quadripole
                                                                      networks)




Software: Immunity test setup         Windows software: Immunity mode

                                       Sweep:                         test level can be different from calibration value, level sweep with
                                                                      start and stop value or with free editable table,
                                                                      level profile editor and sweep function for BCI tests
                                       EUT threshold search:          different opportunities for manual and automatic control
                                       EUT monitoring:                power meter use as EUT monitoring device, keyboard activity for
                                                                      test interrupt with possibility for writing test report commands
                                                                      (EUT reaction etc.), output control for user port
                                       Additional features:           for each frequency step or each monitoring event output control for
                                                                      user port (to control a RF switch for the use of two amplifier)
                                       One click report generation:   tool for test report generation in rtf format, works with dif-
                                                                      ferent user changeable templates, post processing of measurement
                                                                      data (input for test conditions, EUT parameters and comments), free
                                                                      changeable structure and items of the report, user support of
                                                                      repetitive inputs
                                       Export function:               result and calibration files can be converted to txt files, graphs can
                                                                      be zoomed and converted to jpg files

Software: EUT monitoring setup




82-253290 E02 March 2010
6                        nsG 4070
    TesT sysTem for ConduCTed and radiaTed immuniTy




                                         Analog ports

                                          Front panel
                                          Generator output:             N socket 50 Ω, 9 kHz – 1 GHz
                                          Power amplifier input:        N socket 50 Ω, max. +10 dBm
                                          Power amplifier output:       N socket 50 Ω
                                          Power meter channel 1 to 3:   as defined in chapter “Power meter“

                                          Back panel
                                          Monitoring input analog:      BNC socket, 0-24 V Ri=15 kΩ, 6 mV resolution
                                          External modulation input:    BNC socket, impedance >10 kΩ,
                                                                        level: 1 Vpp to get 100% AM, 1 Hz – 50 kHz
                                          10 MHz reference output:      BNC socket, approx. 1 Vpp / 50 Ω




                                         Digital ports

    NSG 4070 front panel with RF ports    Front panel
                                          USB                           USB host connector for USB stick, keyboard, mouse
                                          Back panel
                                          User port:                    D-Sub 15 pole
                                                                        4 TTL inputs
                                                                        4 TTL outputs
                                                                        +12 V / 200 mA, -12 V / 200 mA, +5 V / 200 mA power supply
                                          Monitoring digital input 1:   BNC socket
                                                                        0-24 V via optical coupler Ri=1.5 kΩ,
                                                                        switching threshold approx. 2-3 V
                                          Monitoring digital input 2:   BNC socket
                                                                        0-24V via optical coupler, Ri=1.5 kΩ,
                                                                        switching threshold approx. 2-3 V
                                          Monitoring optical input:     LWL (Light wave connector), HP versatile link HFBR0501 series 40
                                                                        kBd, (avoid scattered light on the back panel)
                                          Trigger input:                BNC socket, TTL for external triggering, max. frequency 100 Hz,
                                                                        trigger delay <10 ms
                                          RS232:                        D-Sub 9 pole, up to 115200 Bd
                                          PS2 keyboard:                 PS2
                                          USB                           USB host connector for USB stick, keyboard, mouse
                                          USB device connector:         for remote control
                                          Network:                      RJ45




    NSG 4070 datasheet
                           nsG 4070                                                                                                     7

TesT sysTem for ConduCTed and radiaTed immuniTy




                                      Power supply

                                      Power supply unit               100 to 240 VAC        recommended           recommended
                                                                      50 / 60 Hz            fuse F1 for nominal   fuse F1 for nominal
                                                                      autoranging           110 V                 230 V

                                      Power consumption
                                      without power amplifier:        approx. 80 W         1 A (slow)             0.5 A (slow)

                                      20 W module:                    approx. 215 W        4 A (slow)             1.6 A (slow)

                                      30 W module                     approx. 240 W        4 A (slow)             1.6 A (slow)

                                      75 W module                     approx. 415 W        6.3 A (slow)           2.5 A (slow)




                                      General data

                                       Operating temperature range:   0°C to 40°C
                                       Storage temperature range:     -20°C to 60°C
                                       Relative humidity:             95% / 30°C (no moisture condensation)

                                       EMC:                           DIN/EN 61326-1:2006
                                       Shock:                         DIN/EN 60068-2-27
                                       Vibration:                     DIN/EN 60068-2-6
                                       Protection class:              DIN/EN 61010-1/IEC 61010-1




                                      Mechanical specifications

                                       Size (W x H x D) :             45 cm (19“) x 15 cm (3HU) x 42.3 cm (with handle bar and foot)
                                       Weight:                        approx. 15 kg (with internal power amplifier),
                                                                      approx. 8 kg (without internal power amplifier)
                                       Size of cardboard box:         80 cm x 61 cm x 34 cm (also for options ATN 60xx and/or LE 4070
                                                                      additional space available)
                                       Weight of cardboard box:       approx. 8 kg (empty)




82-253290 E02 March 2010
8                        nsG 4070
    TesT sysTem for ConduCTed and radiaTed immuniTy




                                         Application for IEC/EN 61000-4-6, calibration set-up with CDN




                                                                      6 dB attenuator

                                                                                                                                                                                                                                     Compact generator NSG 4070
                                                                                                                                                                                                                                     with built-in power amplifier
                                                                                                                                                                                NSG 4070
                                                                                                                                                                                                                                                                                                                                                                                                                     Local
                                                                                                                                                                                  RF out                                                                                                                                                                             MHz                                              RF
                                                                                                                                                                                                                                                                                                                              7             8          9            dBµV           FRQ        LVL      MOD           ON/OFF


                                                                                                                                                                                                                                                                                                                                                                    kHz
                                                                                                                                                                                                                                                                                                                              4             5          6            dBm            STO        RCL                    Help
                                                                                                                                                                                             Power meter




                                                                                       CDN
                                                                                                                                                                                  Amp in     ch.3 < +20 dBm
                                                                                                                                                                                                                                                                                                                                                                     Hz
                                                                                                                                                                                                                                                                                                                              1             2          3             V
                                                                                                                                                                                                                                                                                                                                                                                StSize       StSize   StSize
                                                                                                                                                                                                                                                                                                                                                                                 Step         Step     Step
                                                                                                                                                                                                                                                                                                                                                                                                                      2nd
                                                                                                                                                                                                                                                                                                                                                                                     1          2       3

                                                                                                                                                                                                                                                                                                                              0             .                       Enter
                                                                                                                                                                                             ch.2 < +20 dBm                                                                                                                                                                              Tuning
                                                                                                                                                                                 < +10 dBm


                                                                                                                                                                                                                                                                                                                              Hold
                                                                                                                                                                                  Amp out
                                                              150 Ω




                                                                                                            100 Ω




                                                                                                                                                                                             ch.1 < +27 dBm



                                                                       AE-side                   EUT-side
                                                                                                                                                                                                                                                                                                                              Run
                                                                                                                                                                                                                                                                                                           Back               Stop
                                                                                                                                                                                                                                                                                                                                                                                                               USB   Power




                                                          150 Ω termination                      150/50 Ω adapter                                                                                Power meter ch. 1
                                                    Ground plane




                                         Application for IEC/EN 61000-4-6, EUT set-up with CDN

                                                                                                                                                       Compact generator NSG 4070
                                                                                                                                                       with built-in power amplifier
                                                                                                                                               NSG 4070
                                                                                                                                                                                                                                                                                                                                                                            Local
                                                                                                                                                     RF out                                                                                                                                                MHz                                                               RF
                                                                                                                                                                                                                                                                     7              8           9         dBµV                FRQ               LVL         MOD             ON/OFF


                                                                                                                                                                                                                                                                                                           kHz
                                                                                                                                                                                                                                                                     4              5           6          dBm                STO               RCL                         Help
                                                                                                                                                               Power meter
                                                                                                                                                    Amp in     ch.3 < +20 dBm
                                                                                                                                                                                                                                                                                                             Hz
                                                                                                                                                                                                                                                                     1              2           3            V
                                                                                                                                                                                                                                                                                                                             StSize         StSize         StSize
                                                                                                                                                                                                                                                                                                                              Step              Step        Step
                                                                                                                                                                                                                                                                                                                                                                             2nd
                                                                                                                                                                                                                                                                                                                                  1               2           3




                                                                                     6 dB attenuator                                                                                                                                                                 0              .                     Enter
                                                                                                                                                               ch.2 < +20 dBm                                                                                                                                                         Tuning




    NSG 4070 with KEMZ 801 and CAL 801
                                                                                                                                                   < +10 dBm


                                                                                                                                                                                                                                                                     Hold
                                                                                                                                                   Amp out
                                                                                                                                                               ch.1 < +27 dBm

                                                                                                                                                                                                                                                                     Run
                                                                                                                                                                                                                                                      Back           Stop
                                                                                                                                                                                                                                                                                                                                                                    USB     Power




                                                             Auxiliary                                                                                         Equipment
                                                             equipment                                                                                         under test
                                                                                                      CDN
                                                                      AE                                                                                                     EUT
                                                                                          AE-side                   EUT-side




                                                                       Insulating                       Ground plane                                                                         Insulating




                                         Application for IEC/EN 61000-4-6, calibration set-up with EM clamp

                                                                                                                                   Compact generator NSG 4070
                                                                                                                                   with built-in power amplifier
                                                                                                                           NSG 4070
                                                                                                                                                                                                                                                                                                                                                       Local
                                                                                                                                RF out                                                                                                                                       MHz                                                                        RF
                                                                                                                                                                                                                                               7             8   9          dBµV                    FRQ            LVL       MOD                       ON/OFF


                                                                                                                                                                                                                                                                            kHz
                                                                                                                                                                                                                                               4             5   6          dBm                      STO           RCL                                 Help
                                                                                                                                           Power meter
                                                                                                                                Amp in     ch.3 < +20 dBm
                                                                                                                                                                                                                                                                             Hz
                                                                                                                                                                                                                                               1             2   3           V
                                                                                                                                                                                                                                                                                                    StSize        StSize     StSize
                                                                                                                                                                                                                                                                                                     Step             Step    Step
                                                                                                                                                                                                                                                                                                                                                        2nd
                                                                                                                                                                                                                                                                                                      1                 2      3

                                                                                                                                                                                                                                               0             .              Enter
                                                                                                                                           ch.2 < +20 dBm                                                                                                                                                    Tuning
                                                                                                                               < +10 dBm


                                                                                                                                                                                                                                               Hold
                                                                                                                               Amp out
                                                                                                                                           ch.1 < +27 dBm

                                                                                                                                                                                                                                               Run
                                                                                                                                                                                                                              Back             Stop
                                                                                                                                                                                                                                                                                                                                      USB              Power




                                                                                           6 dB attenuator                                                       Power meter ch. 1

                                                          50 Ω
                                                          termination
                                                                                       AE-side                                                                                                                                     EUT-side
                                                                                                                                                                                                                                                                                        100 Ω
                                                                             100 Ω




                                                                                                                      EM clamp                                                                                EM-Koppelzange
                                                                                                                                                                                                              KEMZ 801
                                                                                                                                                                                                              150 kHz ... 230 MHz (1000 MHz)       EUT




                                                           Ground plane                    150/50 Ω adapter                                                                                                                                              150/50 Ω adapter




    NSG 4070 datasheet
                           nsG 4070                                                                                                                                                                                                                                                                          9

TesT sysTem for ConduCTed and radiaTed immuniTy




                                      Application for IEC/EN 61000-4-6, calibration set-up with current injection probe


                                                                                                      Compact generator NSG 4070
                                                                                                      with built-in power amplifier
                                                                                                  NSG 4070
                                                                                                                                                                                                                                                                           Local
                                                                                                    RF out                                                                                                   MHz                                                            RF
                                                                                                                                                                                 7          8       9       dBµV          FRQ           LVL            MOD                 ON/OFF


                                                                                                                                                                                                            kHz
                                                                                                                                                                                 4          5       6       dBm           STO           RCL                                Help
                                                                                                                  Power meter
                                                                                                    Amp in        ch.3 < +20 dBm
                                                                                                                                                                                                             Hz
                                                                                                                                                                                 1          2       3        V
                                                                                                                                                                                                                         StSize        StSize         StSize
                                                                                                                                                                                                                          Step          Step           Step
                                                                                                                                                                                                                                                                            2nd
                                                                                                                                                                                                                           1              2             3

                                                                                                                                                                                 0          .               Enter
                                                                                                                  ch.2 < +20 dBm                                                                                                  Tuning
                                                                                                   < +10 dBm


                                                                                                                                                                                 Hold
                                                                                                    Amp out
                                                                                                                  ch.1 < +27 dBm

                                                                                                                                                                                 Run
                                                                                                                                                           Back                  Stop
                                                                                                                                                                                                                                                               USB         Power




                                                                                                                                      Power meter ch. 1

                                                                               150 Ω
                                                                               termination


                                                                                                                                             150/50 Ω adapter


                                                                   6 dB             Calibration                          Current injection                                                                               Ground plane
                                                                   attenuator                                            probe




                                      Application for IEC/EN 61000-4-6, EUT set-up with EM clamp or current injection probe
                                      and for example with use of a monitoring probe

                                                                                                         Compact generator NSG 4070
                                                                                                         with built-in power amplifier
                                                                                                   NSG 4070
                                                                                                                                                                                                                                                                              Local
                                                                                                       RF out                                                                                                      MHz                                                         RF
                                                                                                                                                                                     7          8       9         dBµV         FRQ          LVL             MOD               ON/OFF


                                                                                                                                                                                                                  kHz
                                                                                                                                                                                     4          5       6         dBm          STO          RCL                                Help
                                                                                                                     Power meter
                                                                                                       Amp in        ch.3 < +20 dBm
                                                                                                                                                                                                                    Hz
                                                                                                                                                                                     1          2       3           V
                                                                                                                                                                                                                            StSize         StSize        StSize
                                                                                                                                                                                                                             Step              Step           Step
                                                                                                                                                                                                                                                                               2nd
                                                                                                                                                                                                                                  1              2             3

                                                                                                                                                                                     0          .              Enter
                                                                                                                     ch.2 < +20 dBm                                                                                                   Tuning
                                                                                                      < +10 dBm


                                                                                                                                                                                     Hold
                                                                                                      Amp out
                                                                                                                     ch.1 < +27 dBm

                                                                                                                                                                                     Run
                                                                                                                                                                Back                 Stop
                                                                                                                                                                                                                                                                     USB      Power




                                                                         6 dB attenuator
                                                                                                                                      Power meter ch. 1
                                                    Auxiliary                                                                                                                                                                                                                          Equipment
                                                    equipment                                                                                                                                                                                                                          under test

                                                      AE             AE-side                                                                                         EUT-side                                                                                                            EUT
                                                                                        EM clamp                                                EM-Koppelzange
                                                                                                                                                KEMZ 801
                                                                                                                                                150 kHz ... 230 MHz (1000 MHz)           EUT




                                                      Insulating                Ground plane                                                                                                        Monitoring probe                                                                       Insulating




                                      Power recommendation, achievable test levels with 6 dB attenuator, 0.5 dB cable loss,
                                      max. insertion loss of the coupling device and AM with 80% modulation depth

                                       Amplifier module:                                  20 W                                                                                   30 W                                                                                                      75 W

                                      CDN:                                               15 V EMF                                                                                18 V EMF                                                                                                  30 V EMF

                                      EM clamp (KEMZ 801):                               8 V EMF                                                                                 11 V EMF                                                                                                  17 V EMF

                                      Current injection clamp (CIP 9136):                5 V EMF                                                                                 6 V EMF                                                                                                   10 V EMF (typ.)




82-253290 E02 March 2010
10                        nsG 4070
     TesT sysTem for ConduCTed and radiaTed immuniTy




                                        Application for automotive BCI, calibration set-up (power requirements and frequency
                                        range demand external power amplifier and directional coupler)
                                                                            NSG 4070
                                                                            RF output     NSG 4070
                                                                                                                                                                                                                                                                     Local



                                                                                                                                                                                                                                                                                 Power meter
                                                                                                RF out                                                                                          MHz                                                                   RF
                                                                                                                                                                  7          8       9         dBµV           FRQ              LVL           MOD                     ON/OFF


                                                                                                                                                                                                kHz
                                                                                                                                                                  4          5       6          dBm           STO              RCL                                   Help




                                                                                                                                                                                                                                                                                 ch. 1 stress level
                                                                                                               Power meter
                                                                                                Amp in        ch.3 < +20 dBm
                                                                                                                                                                                                 Hz
                                                                                                                                                                  1          2       3           V
                                                                                                                                                                                                             StSize       StSize            StSize
                                                                                                                                                                                                              Step             Step           Step
                                                                                                                                                                                                                                                                       2nd
                                                                                                                                                                                                                1                2             3

                                                                                                                                                                  0          .                 Enter



                                                                                                                                                                                                                                                                                 ch. 2 forward power
                                                                                                              ch.2 < +20 dBm                                                                                          Tuning
                                                                                               < +10 dBm


                                                                                                                                                                  Hold
                                                                                               Amp out



                                                                                                                                                                                                                                                                                 ch. 3 reverse power
                                                                                                              ch.1 < +27 dBm

                                                                                                                                                                  Run
                                                                                                                                                  Back            Stop
                                                                                                                                                                                                                                                     USB             Power




                                                                      Power amplifier
                                                                      input                    Amp in                                                                                                                                                         Amp out




                                                 50 Ω Termination                                                                                                                                                                                                             Output

                                                                                                                                      DIRECTIONAL COUPLER
                                                                                                                                             DCP 0100
                                                                                                                                          0.01 ... 1000 MHz




                                                                                                                                                                                         Directional coupler


                                                 Calibration jig           BCI probe                                           Ground plane




                                        Application for automotive BCI, EUT set-up with monitoring probe
     NSG 4070 automotive BCI solution
                                                                            NSG 4070
                                                                            RF output    NSG 4070
                                                                                                                                                                                                                                                                Local



                                                                                                                                                                                                                                                                                Power meter
                                                                                             RF out                                                                                       MHz                                                                    RF
                                                                                                                                                              7          8       9       dBµV           FRQ             LVL            MOD                     ON/OFF


                                                                                                                                                                                         kHz
                                                                                                                                                              4          5       6       dBm            STO             RCL                                     Help




                                                                                                                                                                                                                                                                                ch. 1 level monitoring
                                                                                                           Power meter
                                                                                             Amp in        ch.3 < +20 dBm
                                                                                                                                                                                          Hz
                                                                                                                                                              1          2       3        V
                                                                                                                                                                                                       StSize          StSize         StSize
                                                                                                                                                                                                        Step            Step           Step
                                                                                                                                                                                                                                                                2nd
                                                                                                                                                                                                         1                2             3

                                                                                                                                                              0          .               Enter



                                                                                                                                                                                                                                                                                ch. 2 forward power
                                                                                                           ch.2 < +20 dBm                                                                                       Tuning
                                                                                          < +10 dBm


                                                                                                                                                              Hold
                                                                                           Amp out



                                                                                                                                                                                                                                                                                ch. 3 reverse power
                                                                                                           ch.1 < +27 dBm

                                                                                                                                                              Run
                                                                                                                                               Back           Stop
                                                                                                                                                                                                                                               USB             Power




                                                                                           Amp in                                                                                                                                                          Amp out




                                                                      Power amplifier input                                                                                                                                                                                    Output
                                                      Auxiliary                                                                     DIRECTIONAL COUPLER


                                                      equipment
                                                                                                                                           DCP 0100
                                                                                                                                       0.01 ... 1000 MHz




                                                         AE                                                          EUT                                                             Directional coupler




                                                         Insulating    BCI probe   Monitoring probe                               Equipment
                                                    Ground plane                                                                  under test




     NSG 4070 datasheet
                           nsG 4070                                                                                                                                                                                                                                                                                                             11

TesT sysTem for ConduCTed and radiaTed immuniTy




                                      Application for automotive BCI with two power amplifiers, calibration set-up

                                                                               NSG 4070                                   NSG 4070                                                                                                                                                                                        NSG 4070
                                                                               RF output                                  User port                                                                                                                                                                                       Power meter
                                                                                                                                                                                                                                                                                                                          ch. 1 stress level
                                                                                                                                                                                                                                                                                                                          ch. 2 forward power
                                                                                            NSG 4070
                                                                                               RF out
                                                                                                                                                                   7      8     9        MHz
                                                                                                                                                                                        dBµV            FRQ            LVL       MOD
                                                                                                                                                                                                                                                          Local
                                                                                                                                                                                                                                                           RF
                                                                                                                                                                                                                                                          ON/OFF
                                                                                                                                                                                                                                                                                                                          ch. 3 reverse power
                                                                                                                                                                                        kHz
                                                                                                                                                                   4      5     6       dBm              STO           RCL                                Help
                                                                                                         Power meter



                                               Switch (part of SW 4070)
                                                                                              Amp in     ch.3 < +20 dBm
                                                                                                                                                                                         Hz
                                                                                                                                                                   1      2     3        V
                                                                                                                                                                                                        StSize        StSize     StSize
                                                                                                                                                                                                         Step             Step    Step
                                                                                                                                                                                                                                                           2nd
                                                                                                                                                                                                          1                 2      3

                                                                                                                                                                   0      .             Enter
                                                                                                         ch.2 < +20 dBm                                                                                          Tuning
                                                                                             < +10 dBm


                                                                                                                                                                   Hold
                                                                                              Amp out
                                                                                                         ch.1 < +27 dBm




                                                                       1                                                                                    Back
                                                                                                                                                                   Run
                                                                                                                                                                   Stop
                                                                                                                                                                                                                                         USB              Power




                                                                           A     B


                                                                                              Amp in                                                                                                                                                 Amp out
                                                                                                                                                                                                                                                                                                                          Interlock



                                                             Power amplifier
                                                             inputs
                                                                                                                                                                                                                                                                                               2
                                                                                              Amp in                                                                                                                                                 Amp out
                                                                                                                                                                                                                                                                                                        A             B

                                                50 Ω Termination

                                                                                                                                                                                                                                                                                                                     Switch (part of SW 4070)
                                                                                                                                                   DIRECTIONAL COUPLER




                                                Calibration jig            BCI probe                                            Ground plane




                                      Application for IEC/EN 61000-4-20 up to 1 GHz (power requirements and frequency range
                                      demand external power amplifier and directional coupler, field probe control required
                                      optional software)


                                                                                                                                                                                                                                                                                                                          Software


                                                                                     NSG 4070
                                                                                     RF output                              NSG 4070
                                                                                                                               RF out
                                                                                                                                                                                                               7             8     9            MHz
                                                                                                                                                                                                                                               dBµV                 FRQ          LVL      MOD
                                                                                                                                                                                                                                                                                                             Local
                                                                                                                                                                                                                                                                                                              RF
                                                                                                                                                                                                                                                                                                            ON/OFF


                                                                                                                                                                                                                                               kHz
                                                                                                                                                                                                               4             5     6           dBm                  STO          RCL                         Help
                                                                                                                                         Power meter
                                                                                                                              Amp in     ch.3 < +20 dBm
                                                                                                                                                                                                                                                Hz
                                                                                                                                                                                                               1             2     3            V
                                                                                                                                                                                                                                                                   StSize       StSize   StSize
                                                                                                                                                                                                                                                                    Step         Step     Step
                                                                                                                                                                                                                                                                                                             2nd
                                                                                                                                                                                                                                                                     1             2       3

                                                                                                                                                                                                               0             .                 Enter
                                                                                                                                         ch.2 < +20 dBm                                                                                                                     Tuning
                                                                                                                             < +10 dBm


                                                                                                                                                                                                               Hold
                                                                                                                              Amp out
                                                                                                                                         ch.1 < +27 dBm

                                                                                                                                                                                                               Run
                                                                                                                                                                                                Back           Stop




                                                                                                                                                                                                                                                                                                                       Power meter 50 Ω
                                                                                                                                                                                                                                                                                                  USB       Power




                                                                                                                                                                                                                                                                                                                       ch. 1 n.c.
                                                                                                                                                                                                                                                                                                                       ch. 2 forward power
                                                                                                                                                                                                                                                                                                                       ch. 3 n.c.

                                                                                                                              Amp in                                                                                                                                                                    Amp out




                                                                                           Power amplifier input                                                                                                                                                                                                      Output

                                                                                                                                                                              DIRECTIONAL COUPLER
                                                                                                                                                                                     DCP 0100
                                                                                                                                                                                    0.01 ... 1000 MHz




                                                        GTEM cell                                                                                                                                                                        Directional coupler




82-253290 E02 March 2010
12                             nsG 4070
     TesT sysTem for ConduCTed and radiaTed immuniTy

                                                     Delivery items for the NSG 4070 series

                                                     Compact immunity test system NSG 4070, 9 kHz - 1 GHz RF generator and power meter (power amplifier
                                                     as selected); remote control software on USB stick; spare fuses (2); RS232 cable (Nullmodem); mains
                                                     cable GB, CH, USA/JP, EU; LAN cable, crossover, 3 m; keyboard (English); operating manual



     NSG 4070 with rack mounting kit                 Delivery information

                                                      Part number                    Description

                                                      253293                         NSG 4070-0
                                                                                     Compact immunity test system NSG 4070, 9 kHz - 1 GHz RF
                                                                                     generator and power meter (without power amplifier)
                                                      253292                         NSG 4070-20
                                                                                     Compact immunity test system NSG 4070, 9 kHz - 1 GHz RF
                                                                                     generator and power meter (with 20 W module 150 kHz - 230 MHz)
                                                      253291                         NSG 4070-30
                                                                                     Compact immunity test system NSG 4070, 9 kHz - 1 GHz RF
     MD 4070 monitoring probe                                                        generator and power meter (with 30 W module 150 kHz - 230 MHz)
                                                      253290                         NSG 4070-75
                                                                                     Compact immunity test system NSG 4070, 9 kHz - 1 GHz RF
                                                                                     generator and power meter (with 75 W module 150 kHz - 230 MHz)
                                                      97-253290                      NSG 4070-TC
                                                                                     Traceable calibration (ISO17025), order only with the device
                                                      98-253290                      NSG 4070-DKD
                                                                                     DKD calibration (ISO17025), order only with the device
                                                      253103                         NSG 4070 Rack
                                                                                     Rack mounting kit for NSG 4070
                                                      253850                         SW 4070
                                                                                     Option for NSG 4070: RF-Switch network 2x SPDT
                                                      253900                         MD 4070
     SW 4070, RF switch network 2xSPDT                                               Monitoring device (current sensing probe) active/passive with
                                                                                     PSU 6001 and LE 242 in suitcase
                                                      254747                         USO 4013-RS232-20
                                                                                     USB to serial/optical converter, 20 m POF, RS232 converter
                                                      253715                         WIN 6000
                                                                                     Test house software with 15 months support
                                                      253104                         LE 4070
                                                                                     RF cable set for NSG 4070, consist of: RF cable, N(m)-N(m), 3 m
                                                                                     with one right-angle plug, RG223; RF cable, BNC(m)-N(m), 250
                                                                                     mm, RG223; RF cable, N(m)-N(m), 120 mm, RG58; RF cable,
                                                                                     N(m)-BNC(m), 2 m, RG223; adapter N(m)-N(m); adapter N(f)-BNC(m)
                                                      235308                         ATN 6025
                                                                                     Attenuator 25 W cw N(f)-N(f)
                                                      235309                         ATN 6050
                                                                                     Attenuator 50 W cw N(f)-N(f)
     ATN 6075, 6 dB attenuator, 75 Watts              235307                         ATN 6075
                                                                                     Attenuator 75 W cw N(f)-N(f), incl. cable LE 213
     Teseq GmbH                                       For CDNs, EM clamp, current injection probes, BCI accessories and antennas please use the web
     Landsberger Str. 255 · 12623 Berlin · Germany
     T + 49 30 56 59 88 35 F + 49 30 56 59 88 34
                                                      page www.teseq.com.
     desales@teseq.com www.teseq.com


     NSG 4070 datasheet

								
To top