SPECIFICATIONS ของเครื่องตรวจรับสัญญาณ DME _DISTANCE MEASURING

Document Sample
SPECIFICATIONS ของเครื่องตรวจรับสัญญาณ DME _DISTANCE MEASURING Powered By Docstoc
					TECHNICAL SPECIFICATIONS
LIST OF CONTENTS

  1.      GENERAL REQUIREMENT
  2.      DVOR SPECIFICATIONS
  3.      DME SPECIFICATIONS
  4.      REMOTE MAINTENANCE AND MONITORING (RMM) FOR DVOR/DME
  5.      DVOR/DME SPARE PARTS
  6.      TOOL KITS AND SERVICE AIDS
  7.      TECHNICAL DOCUMENTS
  8.      ACCOMMODATION AND ENVIRONMENTAL CONDITION
  9.      MAINTENANCE
  10.     UNINTERRUPTED POWER SUPPLY
  11.     PMDT SPECIFICATIONS
  12.     HANDHELD COMPUTER SPECIFICATIONS
  13.     งานปรับปรุง COUNTERPOISE

ANNEX A          GLOSSARY
ANNEX B          REFERENCE DOCUMENTS
                         DVOR/DME SPECIFICATIONS

1. GENERAL REQUIREMENT
 1.1 Completed system of DVOR/DME shall be installed for replacement of the currently
      used for Udon Thani Airport. (RE-01-01)
 1.2 The DVOR/DME system shall be dual transmitters and dual monitors configuration.
      The DVOR/DME system shall comprise the followings: (RE-01-02)
      1.2.1 Dual DVOR equipment;
      1.2.2 Dual DME equipment;
      1.2.3 Antenna systems for the above equipment;
      1.2.4 Remote status unit for the above equipment specified in 1.2.1 - 1.2.2 shall be
                equipped at control tower;
      1.2.5 Remote control and status unit for the above equipment specified in 1.2.1 -
                1.2.2 shall be equipped at technical room;
      1.2.6 Remote maintenance and monitoring equipment for the above equipment
                specified in 1.2.1 - 1.2.3 shall be equipped at technical room;
      1.2.7 All RF generators shall be synthesizer.
 1.3 The system performance and signal quality shall be at least complied with the ICAO
      Annex 10 vol. I Radio Navigation Aids, Sixth Edition, Amendments 83 (RE-01-03)
 1.4 The proposed equipment shall be the modular design, or an easy plug - in card or
      modules for quick replacement. It shall be designed for easy maintenance and repair.
      (RE-01-04)
 1.5 The dual independent transmitters shall be housed in the cabinet (s) and operated as
      main and standby facilities. (RE-01-05)
 1.6 Maintenance on one equipment shall be accomplished without disturbing the other.
      (RE-01-06)
 1.7 The equipment shall be designed in common of modules and printed circuit boards.
      (RE-01-07)
 1.8 The equipment shall be designed for high reliability operation. Reliability analysis
       (MTBF, MTBO etc.) of all assemblies for DVOR/DME shall be submitted.
       (RE-01-08)
1.9    The DME equipment shall be designed for co-located with the DVOR system.
       (RE-01-09)
1.10   All outdoor material shall be suitably weather protected by appropriate coat or high
       grade paint in order to withstand severe ambient conditions of outdoor installation due
       to temperature, humidity, rainfalls, as specified in ICAO Annex 14 at the site.
       (RE-01-10)
1.11   The On-Line UPS shall be operated as main power source for DVOR/DME. (RE-
       01-11)
1.12   The 10 KVA On-Line UPS shall be provided. (RE-01-12)
1.13   Power Supply (RE-01-13)
       1.13.1 The DVOR/DME and all peripheral devices shall be operated with 220 + 10
                 VAC, 50 Hz + 5% single phase.
       1.13.2 Surge and lightning arrester with indicators for the stations supply (AC)
                 power shall be installed. The unit shall provide a maintenance free service
                 and bypass the energy from direct lightning strike to the incoming power line
                 without interrupt of supply. Indicator lamp shall be provided to indicate
                 failure of the arrester. Type, model and diagram shall be submitted in
                 the proposal.
       1.13.3 As minimum, surge and lightning arrester specification shall be as follow:
                 1.13.3.1 Response time less than 25 nanoseconds;
                 1.13.3.2 Maximum continuous operating voltage (Uc) at least 320 VAC;
                 1.13.3.3 Voltage protection level (Up) less than 1.5 KV;
                 1.13.3.4 Maximum discharge current (Imax) (8/20 µs) at least 100 KA
1.14   Operating environment (RE-01-14)
       1.14.1 Indoor equipment shall be designed for continuous operation under ambient
                 temperature range of 5 C to 50 C with a relative humidity of up to 90%.
       1.14.2 Outdoor equipment shall be designed for continuous operation under the
                  temperature from 0 C to 60 C with up to 100% humidity of rain and more
                  than 60 mph. wind velocity.
1.15   Manual shall be supplied 3 completed sets. The manual shall comprise : (RE-01-15)
       1.15.1 The manual shall provide information for installation, operation, service
                  maintenance, schematics diagrams and initial set up procedure.
       1.15.2 Test report shall be submitted with the equipment delivery.
1.16   The DVOR/DME station shall be provided an obstruction light with photo
       switch. Type and model shall be submitted in the proposal. (RE-01-16)
1.17   The contractor shall be responsible for improving the grounding system. (RE-
       01-17)
1.18   The contractor shall be responsible for providing installation material such as
       external and internal cablings, cable trays, connectors, cable ties, conduits etc.
       (RE-01-18)
1.19   Interface Control Document (ICD) with fully explanation shall be provided. (RE-
       01-19)

2. DVOR SPECIFICATIONS
  2.1 System accuracy (RE-02-01)
      2.1.1 Azimuth accuracy shall be better than ± 1 degree on ground
              measurement.
      2.1.2 Azimuth stability shall be better than ± 0.5 degree measured at a
              monitor.

2.2     The Dual DVOR equipment shall comprise, but not limited to: (RE-02-02)
       2.2.1 Dual carrier transmitters;
       2.2.2 Dual sideband transmitters;
       2.2.3 Dual monitors;
       2.2.4 DVOR test generator;
       2.2.5 Local control Unit;
       2.2.6 Remote Control and Status Unit;
      2.2.7    Remote Status Unit;
      2.2.8    Antenna Switching Unit;
      2.2.9    Antenna system;
      2.2.10   Portable Navigational Signal Analyzer;

2.3   Carrier transmitter (RE-02-03)
      2.3.1 Frequency band                    -   111.975 – 117.975 MHz.
      2.3.2 Operating frequency               -   114.3 MHz for Udon Thani Airport
      2.3.3 Frequency stability               -   ± 0.002% from the operating frequency.
      2.3.4 Output power                      -   at least 100 watts. (adjustable)
      2.3.5 Spurious output                   -   better than 60 dB. below carrier.
      2.3.6 Carrier Modulation:
               - Reference frequency          -   30 Hz. ± 0.2%
               - Modulation depth             -   30% (adjustable)
               - Identification frequency     -   1020 Hz. ± 50 Hz
               - Identification               -   10% (adjustable)
                 Modulation depth
               - Speech channel filter      - band pass at the range of 300 to 3,000 Hz
                                              within 3 dB relative to the level at 1,000
                                              Hz.
             - Speech modulation depth - up to 30% (the transmission of speech
                                              shall not interfere in any way with basic
                                              navigational function.) (adjustable)
      2.3.7 The identification shall be able to generate any three letters International
             Morse Code for both DVOR and DME
      2.3.8 Identification code shall be computerized set up.
      2.3.9 DME identification shall be provided on every forth DVOR
             identification cycle.
      2.3.10 Protection shall be provided for RF amplifier from damage caused by
             open or short circuit of the output.
      2.3.11 Thruline wattmeter and plug-in element shall be equipped for
             output. Type, model and diagram hall be submitted in the proposal.

2.4   Sideband transmitter (RE-02-04)
      2.4.1 Double sideband DVOR system shall be required.
      2.4.2 Sub-carrier modulation mid-frequency shall be 9960 Hz. ± 1%.
      2.4.3 Phase control circuit shall maintain phase relationship between the
               sidebands and carrier in order that resulting phase stability.
      2.4.4 Thruline wattmeters and plug-in elements shall be equipped for
               each sideband output. Type, model and diagram shall be submitted
               in the proposal.

2.5   Monitor (RE-02-05)
      2.5.1 Bearing accuracy shall be better than ± 0.3 degree
      2.5.2 The monitor shall initiate alarm signal for the following conditions:
              - Bearing alarm shall be adjustable for ± 0.1 degree to ± 2 degrees
              - RF level alarm shall be adjustable for alarm when the carrier level
                decreases 10% to 30% from defined configuration.
              - Identification alarm shall be provided for the following conditions:-
                (a) Level drops more than 50%
                (b) Continuous keyed
                (c) Loss of Identification for more than 15 second (adjustable).
              - Reference signal, 30 Hz Modulation Depth exceed ± 2%;
              - Sub-carrier, 9960 Hz Deviation exceed ± 1%;
              - Sub-carrier, 9960 Hz Modulation Depth exceed ± 2%;
               - Any combination of the above conditions.
      2.5.3 The monitor shall be provided AND/OR configuration.
      2.5.4 The primary alarms shall cause the equipment to initiate its
              shutdown/transfer sequences. The primary alarms are all alarms mentioned
              in item 2.5.2 above.
    2.5.5    The secondary alarms shall generate warning indicator. The secondary alarms
              are not mentioned in item 2.5.2 above.
    2.5.6    The monitor shall be able to display the system information for at least as
             follows:
             - Reference signal, 30 Hz modulation;
             - Variable signal, 30 Hz modulation;
             - 9960 Hz Deviation;
             - Bearing;
             - Identification;
             - Forward and reflect power or standing wave ratio.
    2.5.7    The DVOR equipment shall be transferred to the standby or shut down when
             both monitors generate same alarm signal.
    2.5.8    Alarm delay time shall be adjustable.
    2.5.9    Alarm shall be recorded and retrieved for further investigation.
    2.5.10   The field monitor system (including monitor antenna, antenna mast,
             transmission line, obstruction lighting (complied with the ICAO Annex 14
             vol. I, Fourth Edition, Chapter 6 or Federal Aviation Administration (FAA)
             Standard) with photo switch and power cable, etc.) for monitoring the
             radiated composite signal shall be able to locate at any azimuth suitable for
             installation. Type and model shall be submitted in the proposal.

2.6 DVOR Test Generator (RE-02-06)
    2.6.1 DVOR test generator shall be able to check and calibrate the monitor to
           conform ICAO Annex 10 vol. I Amendments 83.
    2.6.2 Type and model of the test generator shall be submitted in the
           proposal. (in case of separated unit)
    2.6.3 Built in Test (BIT) or Fault Diagnostics shall be provided.
    2.6.4 Built in Test (BIT) or Fault Diagnostics shall be capable of being
           initiated locally and remotely.
2.7 Local Control Unit (RE-02-07)
    2.7.1 Portable Maintenance Data Terminal (PMDT) shall be able to monitor and
             control the DVOR equipment. PMDT shall be able to store and retrieve
             system data (monitor data, controlling and setting up parameters etc.). Brand
             and model shall be submitted in the proposal. (see section 11: PMDT
             specifications)
    2.7.2 The local control unit with indicators shall be at least capable of
             2.7.2.1 Selecting main equipment by front panel switch.
             2.7.2.2 Turning on the standby transmitter into dummy loads for test
                        purposes.
             2.7.2.3 Bypassing monitor.
             2.7.2.4 Selecting Remote/Local.
             2.7.2.5 Resetting alarm.
             2.7.2.6 Shutting down station
    2.7.3 Operating status of the equipment shall be displayed on an indicator panel.

2.8 Remote Control and Status Unit (RCSU) (RE-02-08)
    2.8.1 RCSU located at the technical room at the control tower shall be capable of
             monitoring and controlling of the DVOR.
    2.8.2 RCSU shall be connected via landline (provided by AEROTHAI) and the
             outdoor wireless link (5.470-5.857 GHz).
    2.8.3 The outdoor wireless link between DVOR equipment and the technical
             room shall be provided. Type, model and diagram shall be submitted
             in the proposal.
    2.8.4 The selection for using the landline or the outdoor wireless link as the
             main communication link between DVOR equipment and the
             technical room shall be provided.
    2.8.5 Surge and lightning protection shall be provided at both ends of landline and
             the outdoor wireless link. Type, model and diagram shall be submitted
             in the proposal.
     2.8.6     RCSU shall have at least the following control and monitoring
               functions:
               2.8.6.1 Turn on/off the selected transmitter with indicator;
               2.8.6.2 Transfer and shutdown with indicator;
               2.8.6.3 NORMAL/ALARM indicator and audible alarm;
               2.8.6.4 Alarm silence control with indicator;
               2.8.6.5 Station alarm reset.
     2.8.7     RCSU shall be the desktop computer and/or rack mounted equipment. If
               desk top computer is provided, see section 12: PMDT specifications.

2.9 Remote Status Unit (RE-02-09)
    2.9.1 The status indicator with audible alarm suitable for installation in
             the control tower shall be provided.
    2.9.2 Remote Status Unit shall have at least the following features:
             2.9.2.1 Display the operating status of the DVOR.
             2.9.2.2 Visual and audible alarm with an alarm silence control;
             2.9.2.3 Turn on/off switch.
    2.9.3 The unit shall be installed to console for usage of an air traffic controller at
             the control tower.

2.10 Antenna switching unit (RE-02-10)
     2.10.1 The RF power distributor in the antenna switching unit shall be
              broadband for operation in the range of 108 - 118 MHz.
     2.10.2 Surge and lightning arrester shall be provided for all output ports
              of the distributor.

2.11 Antenna system (RE-02-11)
     2.11.1 Each antenna element shall be adjusted to its operating frequency from the
              factory.
       2.11.2   The proposal shall describe method of sideband feed lines fabrication and
                any other adjustment procedure.
       2.11.3   Antenna VSWR shall not exceed 1.2:1 for carrier and 1.1:1 for sideband.

  2.12 Portable Navigational Signal Analyzer (PNSA) (RE-02-12)
       2.12.1 One (1) set of PNSA shall be provided.
       2.12.2 PNSA shall be able for using as ground testing for the VOR/ILS (VOR,
                localizer, glide path, and marker beacon).
       2.12.3 The PNSA shall consist of the VOR/ILS receiver, built in rechargeable
                battery, battery charger (220 VAC 50 Hz), antenna, antenna pole and
                accessories.
       2.12.4 The PNSA shall be designed with lightweight (not more than 6 kg.) and
                weatherproof.
       2.12.5 PNSA shall be able to analyze VOR/ILS performance in accordance with
                ICAO Annex 10 vol. I Amendment 83 and Doc 8071 Fourth Edition.
       2.12.6 PNSA shall be able to select all VOR/ILS channels.
       2.12.7 All VOR/ILS parameters stored in PNSA shall be exported to a computer via
                RS 232C or USB port.
       2.12.8 PNSA shall be able to send real time measurement data directly to RS
                232C or USB port.
       2.12.9 Interface Control Document (ICD) with fully explanation for extracting or
                decoding the real time measurement data shall be provided. Certified
                document from the authorized company shall be submitted in the
                proposal.

3. DME SPECIFICATIONS
  3.1 The DME equipment shall comprise: (RE-03-01)
      3.1.1 Dual transponders;
      3.1.2 Dual monitors;
      3.1.3 Local Control Unit;
    3.1.4   Remote Control and Status Unit;
    3.1.5   Remote Status Unit;
    3.1.6   Antenna System;

3.2 Transponder (RE-03-02)
    3.2.1 Frequency band                                - 960 - 1215 MHz.
    3.2.2 Operating channel                             - Co-channel with the
                                                          DVOR
    3.2.3 Transmitter characteristics
          3.2.3.1 Frequency stability shall not vary more than ± 0.002% from
                     the assigned frequency.
          3.2.3.2 Pulse spacing shall meet ICAO Annex 10 vol. I Amendment 83.
          3.2.3.3 Pulse shape and spectrum of pulse modulated signal shall meet
                     the standard of DME/N in ICAO Annex 10 vol. I Amendment 83.
          3.2.3.4 Peak effective radiation power of the reply pulse shall not be less
                     than 30 dBw.
          3.2.3.5 The transponder power amplifier shall provide full output power
                     not less than 1000 watts to an antenna throughout the DME
                     frequency band. in order that changing the operating frequency
                     needs no readjustment.
    3.2.4 Receiver characteristics
          3.2.4.1 Frequency stability shall not vary more than ± 0.002% from
                     the assigned frequency.
          3.2.4.2 Sensitivity shall meet ICAO Annex 10 vol. I Amendment 83.
          3.2.4.3 Bandwidth and selectivity shall meet ICAO Annex 10 vol. I
                     Amendment 83.
          3.2.4.4 Short and long distance echo suppression shall be provided and
                     meet ICAO Annex 10 vol. I Amendment 83.
          3.2.4.5 CW. Suppression shall be provided and meet ICAO Annex 10
                      vol. I Amendment 83.
            3.2.4.6   The receiver dynamic range shall meet ICAO Annex 10 vol. I
                      Amendment 83.
     3.2.5 Video
           3.2.5.1   Interrogating pulse spacing error more than ± 2 microseconds
                     shall be rejected.
            3.2.5.2 Receiver dead time shall be adjustable for echo suppression as
                     measured after main delay time.
            3.2.5.3 Long distance echo suppressor shall be provided by automatic
                     receiver gain reduction according to each echo pulse level.
            3.2.5.4 The minimum Transmission rate shall be as close as practicable
                     to 700 PPS.
            3.2.5.5 Maximum transmission rate shall be at least 4,800 PPS.
            3.2.5.6 Identification pulses shall meet ICAO Annex 10 vol. I
                      Amendment 83.
            3.2.5.7 Reply delay, pulse spacing and pulse width shall be adjustable
                     to the specified values without removing any module from
                     the assembly.
            3.2.5.8 Reply delay stability shall be within ± 0.5 microseconds for
                     any interrogation level.
            3.2.5.9 The peak power of each pulse of any pulse pair shall not differ by
                     more than 1 dB. Pulse balance control shall be provided.
            3.2.5.10 System time reference shall be made from the first pulse or
                     second pulse.

3.3 DME Monitor (RE-03-03)
    3.3.1 The monitor shall serve two purposes.
          3.3.1.1 To ensure that the transponder signal is within tolerance as
                    specified in ICAO Annex 10 vol. I Amendment 83.
        3.3.1.2     To be used as a RF signal generator in conjunction with built -in
                    test unit, in order that calibration, testing and maintenance of the
                    transponder.
3.3.2   In case of any “out of tolerance” condition of transponder signal monitor is
        detected, an alarm signal shall be sent to the control unit for transfer or shut
        down functionality.
3.3.3   Alarm history shall be provided to indicate parameters that deviated beyond
        alarm limit and cause an alarm.
3.3.4   The monitor shall initiate alarm signal for the following conditions: -
        3.3.4.1 Reply delay error exceed 1 microsecond;
        3.3.4.2 Reply efficiency is less than 70%;
        3.3.4.3 Effective radiated power (ERP) decreases below 3 dB;
        3.3.4.4 Transmitting pulse count falls below 700 PPS;
        3.3.4.5 Transmitting pulse spacing error exceed 1 microsecond;
        3.3.4.6 Continuous or loss of identification;
        3.3.4.7 Any combination of the above conditions.
3.3.5   The occurrence of primary alarm shall control a transfer action while the
        main transponder is operating and a shut down action while the standby
        transponder is operating. The primary alarms are reply delay and pulse
        spacing alarm.
3.3.6   The occurrence of secondary alarm shall control a transfer action while the
        main transponder is operating. The secondary alarms are all alarms
        mentioned above except reply delay and pulse spacing alarm.
3.3.7   Monitor signal generator output shall be selected in order that the channel
        frequency deviation of + 200 KHz and + 900 KHz of transponder receiver
        can be tested.
3.3.8   Monitor signal generator output level shall be adjustable from -100 dBm to -
        25 dBm or wider.
3.3.9   Monitor PRF shall be adjustable from 100 to 4,800 PPS.
      3.3.10 Transponder and monitor parameters shall be provided and shown on display
             or on indicator lamps for at least the following transponder and monitor
             parameters.
             3.3.10.1 Transmit power;
             3.3.10.2 Reply pulse pair spacing;
             3.3.10.3 Reply efficiency;
             3.3.10.4 Reply delay;
             3.3.10.5 Transmitter pulse count;
             3.3.10.6 Identification.
      3.3.11 Control and Selection for display of those parameters shall be done by a
             personal computer which is permanently located at site.
      3.3.12 The main and standby transponders shall be monitored by both monitors.

3.4 Local Control Unit (RE-03-04)
     3.4.1 Portable Maintenance Data Terminal (PMDT) shall be able to monitor and
               control the DME equipment. PMDT shall be able to store and retrieve
               system data (monitor data, controlling and setting up parameters etc.).
               Brand and model shall be submitted in the proposal. (see section 11:
               PMDT specifications)
     3.4.2 The local control unit with indicators shall be at least capable
               of:
               3.4.2.1 Selecting one of transponders to be a main channel
               3.4.2.2 Turning on/off the standby transponder
               3.4.2.3 Bypassing monitor.
               3.4.2.4 Selecting Remote/Local.
               3.4.2.5 Resetting alarm.
               3.4.2.6 Shutting down station.
     3.4.3 Operating status of the equipment shall be displayed on an indicator panel.
3.5 Remote Control and Status Unit (RCSU) (RE-03-05)
     3.5.1 RCSU located at the technical room at the control tower shall be capable of
             monitoring and controlling of the DME.
     3.5.2 RCSU shall be connected via landline (provided by AEROTHAI) and the
             outdoor wireless link (5.470-5.857 GHz).
     3.5.3 The outdoor wireless link between DME equipment and the technical room
             shall be provided. Type, model and diagram shall be submitted in
             the proposal.
     3.5.4 The selection for using the landline or the outdoor wireless link as
             the main communication link between DME equipment and the
             technical room shall be provided.
     3.5.5 Surge and lightning protection shall be provided at both ends of landline
             and the outdoor wireless link. Type, model and diagram shall be
             submitted in the proposal.
     3.5.6 RCSU shall have at least the following control and monitoring
             functions:
             3.5.6.1 Turn on/off the selected transponder with indicator;
             3.5.6.2 Transfer and shutdown with indicator;
             3.5.6.3 NORMAL/ALARM indicator and audible alarm;
             3.5.6.4 Alarm silence control with indicator;
             3.5.6.5 Station alarm reset.
     3.5.7    RCSU shall be the desktop computer and/or rack mounted equipment.
             If desk top computer is provided, see section 12: PMDT
             specifications.

3.6 Remote Status Unit (RE-03-06)
     3.6.1 The status indicator with audible alarm suitable for installation in
              the control tower shall be provided.
     3.6.2 Remote Status Unit shall have at least the following features:
              3.6.2.1 Display the operating status of the DME.
                   3.6.2.2 Visual and audible alarm with an alarm silence control;
                   3.6.2.3 on/off switch.
         3.6.3     The unit shall be installed to console for usage of an air traffic controller at
                   the control tower.

  3.7 Antenna System (RE-03-07)
       3.7.1 The antenna shall be Omni-directional antenna.
       3.7.2 Dual obstruction light with installing fixture shall be included and
                complied with the ICAO Annex 14 vol. I, Fourth Edition, Chapter 6 or
                Federal Aviation Administration (FAA) Standard. Type and model shall
                be submitted in the proposal.

4. REMOTE MAINTENANCE AND MONITORING (RMM) FOR DVOR/DME
 4.1  RMM capability shall be provided for the systems to monitor and control the system
      status. RMM shall be able to store and retrieve system data (monitor data, controlling
      and setting up parameters etc.). It shall collect and store the data at anytime interval
      for maintenance purpose. (RE-04-01)
 4.2  The RMM shall monitor and control DVOR/DME equipment from anywhere by
      public telephone network. (RE-04-02)
 4.3  The RMM unit shall be interfaced with a PABX to DVOR/DME site via landline
      (provided by AEROTHAI) and the outdoor wireless link (5.470-5.857 GHz).
      (RE-04-03)
 4.4  The communication for the RMM must be separated from that for the RCSU.
      (RE-04-04)
 4.5  The outdoor wireless link between DVOR/DME site and technical room shall be
      provided for distance at least 5 kms. Type, model and diagram shall be submitted
      in the proposal. (RE-04-05)
 4.6  Surge and lightning protection shall be provided at both ends of landline and the
      outdoor wireless link. Type, model and diagram shall be submitted in the
      proposal. (RE-04-06)
 4.7     RMM shall be handheld computer. Brand and model shall be submitted in the
         proposal. (see section 12 handheld computer specification) (RE-04-07)
 4.8     Laser colour printer for hard copy report of the station status and meter reading shall
         be provided as part of the RMM. (RE-04-08)

5 DVOR/DME SPARE PARTS
 5.1  One (1) set of spare part shall be provided. (RE-05-01)
 5.2  One (1) set of spare part consists of one unit of each type of modules, printed circuit
      boards, RF Switches and outdoor wireless links. (RE-05-02)

6. TOOL KITS AND SERVICE AIDS
 6.1 Special tool kits as required by the DVOR/DME system for adjustment and
       maintenance at the site shall be supplied. A detailed list shall be submitted with
       Tender. (RE-06-01)
 6.2 Test cable and extension cards as required for each item of equipment
       shall be supplied. (RE-06-02)

7. TECHNICAL DOCUMENTS
 The Contractor shall provide with the following drawings and manuals:
 7.1    Three (3) sets, hard copy and CD, of mechanical and electrical DVOR/DME drawings
        essential for installation, maintenance and repair of the equipment, including such
        drawings as are needed to identify the components and cable terminations within the
        equipment or its subunits; (RE-07-01)
 7.2    Three (3) sets, hard copy and CD, of DVOR/DME installation and equipment
        instruction manuals, to ensure that setting out in detail the procedures for operation,
        routine maintenance, repair of equipment, test and alignment procedures, including
        schematics and inter-cabling diagrams; (RE-07-02)
 7.3    Three (3) sets, hard copy and CD, of mechanical and electrical DVOR/DME drawings
        essential for installation, maintenance and repair of the equipment, including such
        drawings as are needed to identify the components and cable terminations within the
         equipment or its subunits; (RE-07-03)
 7.4     Three (3) sets, hard copy and CD, of DVOR/DME component parts and sub-units
         manuals setting out in detail of all equipment; (RE-07-04)
 7.5     Operational software and initial setup software shall be supplied, if used.
         (RE-07-05)
 7.6     Test report shall be submitted with the equipment delivery. (RE-07-06)

8. ACCOMMODATION AND ENVIRONMENTAL CONDITION
 8.1  The supplied equipment shall not cause radio interference or shall not be interfered by
      the existing radio communication. (RE-08-01)
 8.2  The bidder shall supply full details of the maximum ambient temperature and
      humidity, which can be tolerated by the equipment under working conditions and
      non-working condition. (RE-08-02)

9. MAINTENANCE
 9.1   The bidder shall make available details of methods and facilities for the
       diagnosis and rectification of faults. (RE-09-01)
 9.2   The bidder shall recommend tools for maintenance of the offered system. The tools
       and test equipment shall be itemized and separately priced. (RE-09-02)

10. UNINTERRUPTED POWER SUPPLY (UPS)
 10.1 General Requirements (RE-10-01)
       10.1.1 UPS shall be True On-Line Type with Double Conversion.
       10.1.2 On-Line UPS including associated circuits for emergency used for the
               DVOR/DME equipment shall be capable of providing backup time at least
               3 hours.
       10.1.3 The battery shall be continuously float charged. The battery charger shall
               be capable of charging batteries, which are completely discharged.
       10.1.4 The UPS provided shall be with protection against overcharging,
               overcurrent and short-circuit, spill proof, maintenance free and with
                 capability of latching shutdown on overload.
       10.1.5 In the event of a main failure, the batteries shall automatically take over
                 without disrupting the operation of the system.
       10.1.6 When UPS is failed or an overload is occurred, Static Transfer Switch shall
                 be able to automatically transfer the load supplied by the inverter to the
                 reserve line without any interruption of the system operation
       10.1.7 In connection with 10.1.6 requirement, Static Transfer Switch shall be able
                 to automatically transfer the load supplied back to its previous operation
                 without any interruption of the system operation when above occurrences
                 are back to the normal state.
       10.1.8 Manual Bypass Switch shall be provided for maintenance purpose. When
                 the manual bypass switch is selected, the system shall be able to operate
                 without any interruption.
       10.1.9 The status of UPS shall be displayed at the technical room as well as visual
                 and audible alarm.
       10.1.10 Protection shall be provided against damage of semiconductors due to the
                 battery polarity being inadvertently reversed.
10.2   Technical Requirements (RE-10-02)
       10.2.1 Input
                 - Voltage                         : 220 VAC หรือ 230 VAC ±15% or better
                 - Frequency                       : 50 Hz ±5% or better
                 - Phase                           : Single (2 Wire + Ground)
       10.2.2 Output
                 - Voltage                         : 220 VAC หรือ 230 VAC ±15% or better
                 - Frequency                       : 50 Hz ±0.5% or better
                 - Phase                           : Single (2 Wire + Ground)
                 - Wave Form                       : Sine Wave
                 - Total Harmonics Distortion : ≤ 3 % for 100% Linear Load
                 - Overall Efficiency              : ≥ 84% at load
                  AC to AC
                 - Crest Factor                   : 3:1 or better
       10.2.3    Overload Capacity
                 - 120% Load                      : 1 Min or better
       10.2.4    Environment
                 - Ambient Temperature            : 0-40 C (Continuous) or better
                 - Humidity                        : 90% continuously with non-condensing
       10.2.5    Audible Noise                    : ≤ 55 dB(A) at 1 m.
       10.2.6    Battery
                 - Type                           :   Maintenance Free Sealed Lead Acid
                 - Discharge                      :   High Rate Discharge
                 - Life Time                      :   ≥ 4ปี at 25 C
                 - Back Up Time                   :   ≥ 15 Minute ที่พิกัดโหลด
                 - Standard Approval              :   ISO 9000 Series, UL Series

       10.2.7   Status and Control Indicator shall be able to: (at least but not limited to)
                - display status and parameters, line input, inverter, output, load on bypass,
                  battery and fault
                - provide visual and audible alarm when main fail, low battery and
                  overload
                - enable and disable alarm
10.3   UPS Training (RE-10-03)
       10.3.1 Training shall be provided for 4 engineers or technicians at site.
       10.3.2 The training course shall include theoretical, practical, installation and
                alignment procedure. The course duration and syllabus shall be submitted.




11. PMDT SPECIFICATIONS
 11.1 หน่วยประมวลผลกลาง (CPU) ต้องทางานที่สัญญาณนาฬิกาอย่างน้อย                    2.00 GHz
         และสนับสนุน Core 2 Duo Technology หรือมีคุณสมบัติดีกว่า
11.2    ระบบ                                                                          Bios
        ของเครื่องคอมพิวเตอร์ต้องมีเครื่องหมายการค้าเดียวกันกับผลิตภัณฑ์ที่เสนอ
        และต้องสามารถแสดงหมายเลขเครื่อง                      (Serial             Number)
        ที่ตรงกับหมายเลขที่ติดมากับตัวเครื่องได้
11.3    มีหน่วยความจาหลักแบบ DDR3 SDRAM 1066 MHz หรือมีคุณสมบัติดีกว่า
        ซึ่งมีขนาดไม่น้อยกว่า                             2                            GB
        และสามารถรองรับการขยายหน่วยความจาสูงสุดได้ไม่น้อยกว่า 4 GB บน Mainboard
        และมี Memory Slot จานวนรวมไม่น้อยกว่า 2 Slot
11.4    มีหน่วยความจาสารอง(Cache Memory) อยู่บนหน่วยประมวลผลกลางไม่น้อยกว่า 3
        MB หรือมีคุณสมบัติดีกว่า
11.5    มี SATA DVD+/-RW Drive ชนิด Internal Drive จานวน 1 Drive
        หรือมีคุณสมบัติดีกว่า
11.6    Hard Disk ชนิด SATA ขนาดความจุไม่น้อยกว่า 250 GB ความเร็วไม่ต่ากว่า 7200
        rpm หรือมีคุณสมบัติดีกว่า
11.7    หน่วยควบคุมการแสดงผล (Graphic Controller) สามารถแสดงความละเอียดสูงสุด
        (Maximum Resolution) ได้ไม่น้อยกว่า 1280 X 1024 จุด
11.8    จอภาพเป็นจอภาพชนิด LCD TFT ซึ่งมีขนาด (viewable image area) ไม่น้อยกว่า 17
        นิ้ว
11.9    ส่วนควบคุมการเชื่อมต่อกับระบบเครือข่าย               (Network           Controller)
        เป็นอุปกรณ์ที่ติดตั้งอยู่บน Mainboard (Build-in on Board) ซึ่งสนับสนุนความเร็ว
        10/100/1000 Mbps โดยมี Interface เป็นแบบ RJ-45
11.10   มีระบบเสียง ซึ่งสนับสนุนการทางานตามมาตรฐาน AC-97 หรือมีคุณสมบัติดีกว่า
11.11   มีส่วนเชื่อมต่ออุปกรณ์ภายนอก (I/O Interface) แบบอนุกรม (Serial Port)
        จานวนไม่น้อยกว่า 1 ช่อง และ USB 2.0 port จานวนไม่น้อยกว่า 8 ช่อง โดย I/O
        Interface ทั้งหมดต้องติดตั้งอยู่บน Mainboard (Build-in on Board)
11.12   มี Expansion Slot จานวนไม่น้อยกว่า 3 slot
11.13   Keyboard ใช้หัวเชื่อมต่อแบบ USB โดยตรง จานวนแป้นพิมพ์รวมกันไม่น้อยกว่า 104
        keys โดยมีตัวอักษรทั้งภาษาไทยและภาษาอังกฤษอยู่บนแป้นพิมพ์อย่างถาวร
11.14   Mouse เป็นชนิด Optical Mouse ที่มีปุ่ม Scroll Wheel โดยใช้หัวเชื่อมต่อแบบ USB
        โดยตรง ทั้งนี้จะต้องมี Mouse Pad ที่สามารถใช้งานร่วมกับ Optical Mouse
        ที่เสนอให้ด้วย
11.15   ตัวเครื่อง, จอภาพ, Keyboard และ Mouse ต้องมีเครื่องหมายการค้าเดียวกัน
        โดยประทับตราเครื่องหมายการค้านั้นไว้บนอุปกรณ์อย่างถาวรจากโรงงานผลิต
11.16   เครื่องคอมพิวเตอร์แต่ละเครื่องต้องมีโปรแกรมระบบปฏิบัติการ (Operating System)
        ซึ่งติดตั้งให้มากับตัวเครื่องเป็นโปรแกรม
        ซึ่งสามารถใช้งานกับโปรแกรมควบคุมการทางานของระบบเครื่องช่วยฯ ที่เสนอ
        พร้อมแผ่นโปรแกรม หรือแผ่น Recovery CD ซึ่งมีลิขสิทธิ์ถูกต้องตามกฎหมาย
        (หากเป็น WINDOWS XP ต้องเป็น XP PRO SP3)
11.17   ต้องมีแผ่น Software Driver CD ของเครื่องคอมพิวเตอร์ที่เสนอ
11.18   เครื่องคอมพิวเตอร์รุ่นที่เสนอจะต้องผ่านการรับรอง Hardware compatible list
        ของระบบปฏิบัติการตามข้อ 11.16
11.19   ตัวเครื่อง (Case) ต้องเป็นแบบ Desktop และมีขนาดของแหล่งจ่ายไฟ (Power
        Supply) ไม่น้อยกว่า 400 watt
11.20   เครื่องคอมพิวเตอร์รุ่นที่เสนอต้องผ่านการรับรองมาตรฐานดังนี้
              - ได้รับการรับรองมาตรฐานระบบคุณภาพ ISO 9000 Series
              -
                  ได้รับการรับรองมาตรฐานการแผ่กระจายของแม่เหล็กไฟฟ้าจากสถาบันที่ได้
                  รับการยอมรับจากนานาชาติ เช่น FCC , VCCI หรือ C-Tick
              -
                  ได้รับการรับรองมาตรฐานด้านความปลอดภัยจากสถาบันที่ได้รับการยอมรับ
                  จากนานาชาติ เช่น UL, CSA, หรือEN
11.21   เครื่องคอมพิวเตอร์ที่เสนอจะต้องมีบริษัทที่เป็นเจ้าของผลิตภัณฑ์
        สาขาของบริษัทที่เป็นเจ้าของผลิตภัณฑ์ หรือมีศูนย์บริการในประเทศไทย
11.22   ต้องรับประกันผลิตภัณฑ์ (อุปกรณ์ทั้งชุด) เป็นเวลาไม่น้อยกว่า 2 ปี (On Site
        Service)

12. HANDHELD COMPUTER SPECIFICATIONS
 12.1 หน่วยประมวลผลกลาง (CPU) ต้องทางานที่สัญญาณนาฬิกาไม่น้อยกว่า 2.00 GHz
       โดยมีเทคโนโลยี แบบ Core 2 Duo Processor Technology หรือมีคุณสมบัติดีกว่า
12.2    หน่วยความจาหลักแบบ DDR2 SDRAM (Memory Bus 667 MHz)
        หรือมีคุณสมบัติดีกว่า ขนาดไม่น้อยกว่า                           2              GB
        และสามารถรองรับการขยายหน่วยความจาสูงสุดได้ไม่น้อยกว่า 4 GB
12.3    หน่วยความจา L2 Cache Memory มีขนาดไม่น้อยกว่า 2 MB
12.4    Harddisk Drive ขนาดความจุไม่น้อยกว่า 250 GB
12.5    ต้องมี DVD+/-RW Drive หรือมีคุณสมบัติดีกว่า ชนิด Internal Drive จานวน 1 Drive
12.6    ต้องมีหน่วยควบคุมการแสดงผลที่มีหน่วยความจาขนาดไม่น้อยกว่า            256       MB
        ซึ่งใช้งานร่วมกับหน่วยความจาหลัก และรองรับ Microsoft DirectX9 เป็นอย่างน้อย
12.7    ต้องมีช่องสาหรับต่ออุปกรณ์ภายนอก (I/O Interface) แบบ USB 2.0 Port
        จานวนไม่น้อยกว่า 3 ช่อง, External VGA Port จานวน 1 ช่อง , มี Serial Port
        อย่างน้อย 1 ช่อง( หรือมีอุปกรณ์แปลง USB เป็น Serial อย่างน้อย 1 ชุด)
12.8    ต้องมีช่องอ่านหน่วยความจาประเภท Secure Digital (SD) แบบติดตั้งภายในตัวเครื่อง
12.9    จอภาพเป็นแบบ WXGA TFT LCD มีขนาดไม่ต่ากว่า 14 นิ้ว
        ซึ่งสามารถแสดงความละเอียดสูงสุดได้ไม่น้อยกว่า                            1280x800
        pixelหรือมีคุณสมบัติดีกว่า
12.10   ต้องมี Internal Wireless LAN ตามมาตรฐาน 802.11b/g หรือมีคุณสมบัติดีกว่า
12.11   มีเทคโนโลยีการเชื่อมต่อแบบ Bluetooth ในตัว
12.12   ต้องมีระบบเสียง พร้อมลาโพงภายในตัวเครื่อง
12.13   ต้องมี Modem ความเร็ว 56 Kbps หรือดีกว่า โดยเป็นอุปกรณ์แบบ Built-in
12.14   ต้องมี Network Interface เป็นแบบ Built-in ชนิด 10/100 Mbps จานวนอย่างน้อย 1 ช่อง
12.15   แป้นพิมพ์           (Keyboard)      มีอักษรภาษาไทย,      ภาษาอังกฤษ,        ตัวเลข
        และเครื่องหมายสัญลักษณ์ต่างๆ พิมพ์อยู่บนแป้นพิมพ์อย่างถาวร
12.16   ต้องมี Pointing Device แบบ TouchPad และมี Mouse เป็นชนิด Optical Mouse
        ที่มีปุ่ม Scroll Wheel โดยใช้หัวเชื่อมต่อแบบ USB โดยตรง ทั้งนี้จะต้องมี Mouse
        Pad ที่สามารถใช้งานร่วมกับ Optical Mouse ที่เสนอให้ด้วย
12.17   Battery ที่ใช้กับเครื่องคอมพิวเตอร์เป็นแบบ Lithium Ion ชนิด Rechargeable ขนาด 6
        Cell หรือมีคุณสมบัติดีกว่า โดยสามารถใช้งานตามปกติได้ไม่น้อยกว่า 2 ชั่วโมง
12.18   มีโปรแกรมระบบปฏิบัติการ(Operating System) ติดตั้งให้มากับตัวเครื่องเป็นโปรแกรม
        ซึ่งสามารถใช้งานกับโปรแกรมควบคุมการทางานของระบบเครื่องช่วยฯ ที่เสนอ
        ซึ่งมีลิขสิทธิ์ถูกต้องตามกฏหมาย พร้อมแผ่นโปรแกรมหรือแผ่น           Recovery CD
        (หากเป็น WINDOWS XP ต้องเป็น XP PRO SP3)
12.19   เครื่องคอมพิวเตอร์รุ่นที่เสนอต้องผ่านการรับรองมาตรฐาน ISO 9000 Series, FCC, UL
        หรือ CSA หรือ ETL เป็นอย่างน้อย
12.20   ต้องมีคู่มือการใช้งานของเครื่องคอมพิวเตอร์รุ่นที่เสนอ
        พร้อมโปรแกรมสนับสนุนการทางาน (Software Driver) ของอุปกรณ์ต่างๆ
        ที่ติดตั้งมากับเครื่องซึ่งจาเป็นต่อการใช้งาน บรรจุอยู่ในแผ่น CD หรือ DVD
12.21   ต้องผ่านการรับรอง Hardware compatible list จาก Microsoft
12.22   ต้องมีกระเป๋าสาหรับใส่เครื่องคอมพิวเตอร์แบบพกพาที่เสนอโดยเฉพาะ
12.23   เครื่องคอมพิวเตอร์ที่เสนอจะต้องมีบริษัทที่เป็นเจ้าของผลิตภัณฑ์
        สาขาของบริษัทที่เป็นเจ้าของผลิตภัณฑ์ หรือมีศูนย์บริการในประเทศไทย
12.24   ต้องรับประกันผลิตภัณฑ์ (อุปกรณ์ทั้งชุด) เป็นเวลาไม่น้อยกว่า 2 ปี
ANNEX A: GLOSSARY

 C           Degree Celsius
AEROTHAI     Aeronautical Radio of Thailand Ltd.
AC           Alternating Current
dB           Decibel
DME          Distance Measuring Equipment
DVOR         Doppler Very high frequency Omni Radio range
FAA          Federal Aviation Administration
GHz          Giga Hertz
Hz           Hertz
ICAO         International Civil Aviation Organization
ICD          Interface Control Document
ILS          Instrument Landing System
KVA          Kilo Volt Amp
Kms          Kilometers
MHz          Mega Hertz
MTBF         Mean Time Between Failure
MTBO         Mean Time Between Outage
mph          mile per hour
PABX         Private Automatic Branch Exchange
PMDT         Portable Maintenance Data Terminal
RF           Radio Frequency
RCSU         Remote Control and Status Unit
RSU          Remote Status Unit
RMM          Remote Monitoring and Maintenance
UHF          Ultra High Frequency
UPS          Uninterrupted Power Supply
USB                Universal Serial Bus
VAC                Voltage of Alternating Current
VOR                Very high frequency Omni Radio range



ANNEX B: REFERENCE DOCUMENTS
ICAO Annex 10 vol. I Radio Navigation Aids, Sixth Edition, Amendments 83
ICAO Annex 14 vol. I Fourth Edition
ICAO Doc 8071 Fourth Edition

				