Direct Digital Counting of Radioisotopes for Thin Layer Chromatography
Document Sample


Direct Digital Counting of Radioisotopes for
Thin Layer Chromatography Applications
I No cutting or scraping—no sample preparation hazards
I Fast, automated 1D and 2D image acquisition and analysis
I Accurate, reliable gas proportional detection technology
Direct Digital Quantitation
Windowless Gas Proportional
Detection Technology No Sample
Prep Hazards!
• Windowless—allows sensitive tritium detection and dual
label measurements • No cutting, scraping
or scintillation
• Resolution—selectable collimators allow optimal
cocktails
resolution and speeds for each application, with positional
to add
accuracy of less than 1 mm in the Y-axis and mechanical
• Minimize
precision of 0.1 mm in the X-axis technician
• Linearity—4-5 decades of linear detection for up to exposure and
1000 times the range of X-ray film without exposure get data in the
guesswork and potential saturation time usually
spent at the fume
• High Sensitivity—detect and quantify less than 100 dpm
hood scraping plates
of 14C per lane for metabolite analysis in less than 10
• High sensitivity
minutes counting for all
• Flexibility—measures beta (3H, 14C, 35S), gamma (99mTc) and isotopes, including
positron (18F, 11C) emitters with no hardware tritium
modifications or additional detectors • Automated acquisition of TLC
lanes or 2D images, from a
single lane, to a model that
holds three 20 x 20 cm TLC
plates
• No contaminated screens and no liquid waste
Self-adjusting Detector anode disposal
detector arm wire, surrounded
by counting gas Ionization of
(not to scale)
Electronics counting gas by
circuit board interaction of
radioactivity with
electrons in gas
Planar sample
(TLC plate or
strips)
containing
radioactivity
Sliding tabs for
automatic
lane scanning
Easy to use
front access
instrument
control
Easy-to-Use Software
WinScan Software
Provides easy-to-use interface for AR-2000 operation and
radio-chromatographic analysis, including instrument control,
method definition and storage, data acquisition, quantitative
analysis and reporting functions.
Features include :
I Real time data display and on-screen analysis tools, including
ROI definition, background subtraction, % total chromatogram
activity and Rf values
I Automatic raw data storage for GLP
I Automatic peak finding with user adjustable selection criteria
I User defined printed or exported reports with associated
acquisition parameters for quality control
I Plot to scale (1:1) printing option for plate overlays
WinScan 2D Imaging Software
Provides graphical image display and analysis for two-
dimensional radio-chromatography samples, including:
I Quantitative ROI analysis using on-screen drawing tools
with smoothing, background subtraction and 1D
chromatogram overlays for selected lane areas
I Programmable stepping and flexible collimator selection for
optimal sensitivity, resolution and scanning time
I Printing of images, associated data and acquisition
parameters, or exporting of Windows metafiles or tab-
delimited Excel compatible data tables
I Includes additional 6mm high efficiency collimator
Bio-Chrom Software for
21 CFR Part 11 Compliance
Comprehensive radio-chromatography acquisition and analysis
software designed for Bioscan instruments, which may be used
in place of WinScan.
Bio-Chrom Plus features include:
I 21 CFR Part 11 compliance features, including access control
and electronic signature tracking
I Audit trails for GLP compliance
I Real time data display and analysis
I Automatic peak detection and auto-scaling display of
chromatograms
I Intuitive method set-up, storage and editing functions
I Extensive evaluation, data export and reporting options
I Half-life correction for short-lived isotope quantitation
Bio-Chrom Lite is the lower cost version available for non-
regulated laboratories and does not include 21 CFR part 11
compliance features. Bio-Chrom Lite and Bio-Chrom Plus are
compatible with all Bioscan HPLC and TLC detection
instruments for a consistent user interface and reduced
training requirements.
AR-2000 Imaging Scanner for radio-TLC
Applications: Specifications:
PET / Nuclear Medicine: Sensitivity (10 min. analysis):
Fast, accurate results for in vivo SPECT or PET 1,000 DPM for 3H, 125I
radiopharmaceutical compounds labeled with 18F, 11C, 100 DPM for 14C, 32P and most other
99m
Tc, 111In, etc. isotopes
• Radiopharmaceutical quality control
Resolution:
• Synthesis process control
0.5—1mm for 3H
Pharmaceutical metabolite analysis: 1 – 2mm for 14C
Radioisotope flexibility and manual or automatic peak 3mm for 32P and most gamma emitters
analysis for low or high activity products, using beta (3H, Linearity:
14
C), gamma or positron-labeled compounds. Calibrated to within 1% (± 2mm)
Background:
Radiotracer toxicology studies: Less than 0.15 CPM per mm
High sensitivity for quantitative measurement of Dimensions (in / cm):
14
C-labeled organic compounds and agrichemicals. 1-Plate: 16 x 9 x 19 / 40 x 23 x 48
2-Plate: 24 x 9 x 19 / 61 x 23 x 48
Lipid biosynthesis / Lipid analysis: 3-Plate: 32 x 9 x 19 / 81 x 23 x 48
1D and 2D analysis of complex lipids, phospholipids and
Weight (lbs / kg):
glycolipids by TLC with no cutting, scraping or transfer for
fast quantitative results. 1-Plate: 33 / 15
2-Plate: 39 / 18
Radiochemical purity: 3-Plate: 45 / 20
Rapid quality assurance results for batch validation of Power:
radiolabeled compounds for tracer or metabolism 110/220 V, 50/60 Hz
studies. Operating system:
Pentium computer, Windows 98/2000/XP,
Radiolabeled reporter gene or enzyme assays: one 9-pin serial port, at least 64 Mb RAM
Simplifies the analysis and improves accuracy for (128 Mb preferred)
traditional radioisotopic CAT or enzymatic conversion Gas Supply / Flow Rates:
assays using TLC. P10 counting gas (90% Argon/10%
Methane) regulated to 10—20 psi
Quantitative biochemical separations and planar
samples using radiolabeled compounds: Environmental:
Programmable scanning and quick-change magnetic Temperature range: 10—40°C
collimators for resolution and sensitivity optimization. Humidity: less than 75% (non-condensing)
Three models provide 1, 2 or 3 TLC plate capacity
Bioscan Inc. Your local representative Bioscan Europe Ltd.
D•ACom Neuves-Maisons France - RCS Nancy B 443 901 715 - 2004/06
4590 MacArthur Blvd., N.W. 58, Avenue de Wagram
Washington, DC 20007 USA 75017 Paris - France
Toll-free (U.S. and Canada) Phone/Fax : + 33 3 83 63 62 67
1-800-255-7226 Email : europe@bioscan.com
Phone : 1-202-338-0974
Fax : 1-202-333-8514 Please visit our website for information on
Email : sales@bioscan.com your local representative
www.bioscan.com
Related docs
Get documents about "