					Revision Date December 3, 2008                                             Spec_006 - Version 2.0

                       Architectural Specification Sheet


            HEBEL SUPERCRETE COMMERCIAL INDUSTRIAL WALL
                     SYSTEMS - SUPERCOAT PAINT

1.        GENERAL
          This section covers general surface preparation of Hebel Supercrete Commercial
          Industrial Wall Systems, sealing and painting using Supercoat Paint.

          The applicator shall be suitably skilled and experienced to perform the tasks required.
          The applicator remains solely responsible for completion, quality and assurance of their
          work.

          Any amendment to this specification sheet shall be formerly agreed in writing between the
          applicator and the project designer before work shall proceed.

1.1       REFERENCED DOCUMENTS
          Documents referred to in this specification are:

          a) Health & Safety in Employment Act 1992
          b) Supercoat Coating Systems Technical Manual
          c) Supercoat Coating Systems Training Manual
          d) www.hebel.co.nz/coatings/index.php

1.2       NO SUBSTITUTIONS
          Substitutions are not permitted to any specified Supercoat Coating System, or associated
          components and products.

1.3       LICENCED APPLICATORS
          All work must be carried out by Licenced Supercoat Coating System applicators.

1.4       HEALTH & SAFETY
          Site personnel shall comply with all requirements set down by the Health & Safety in
          Employment Act 1992 including the obligations:

          a) To refer to the Material Safety Data Sheets for each Supercoat product located at
          www.hebel.co.nz/coatings/index.php .

          b) Keep the main contractor, employees and sub contractors informed of any on site
          hazards and put in place procedures for dealing with emergencies.

          c) Supply suitable protective clothing and equipment.

1.5       SAMPLE PREPARATIONS
          Prepare samples of the finished work as scheduled, this shall include preparation and
          colour as specified in section 4.0) Specified Coating System Selections. Obtain approval
          of appearance and location from the main contractor before proceeding.

2.        SPECIFIED PRODUCTS

2.1       SUPERCOAT SURFACE SEALER
          Supercoat Surface Sealer is the only permitted sealer/primer. Supercoat Surface Sealer is
          guaranteed for consistency and performance under the manufacturers product warranty
          and in accordance with the technical data & information sheets located at
          www.hebel.co.nz/coatings/index.php.
Revision Date December 3, 2008                                                Spec_006 - Version 2.0

                       Architectural Specification Sheet


2.2       SUPERCOAT PAINT
          All paint products are to be Supercoat Paint. Supercoat Paint is guaranteed for
          consistency and performance under the manufacturers product warranty and in
          accordance with the technical data & information sheets located at
          www.hebel.co.nz/coatings/index.php .

3.        EXECUTION

3.1       INSPECTION
          The Applicator shall inspect the Hebel Supercrete Commercial Industrial Wall System
          substrate to be coated and report to the main contractor if the applicator believes that
          work cannot be completed to the required standard due to the condition of the block
          surface.

3.2       PROTECTION
          All adjoining surfaces and areas susceptible to damage from coating or paint over-spill
          must be covered and protected accordingly by the applicator.

3.3       HARDWARE REMOVAL
          Remove, or mask and protect, any hardware or fittings and replace upon completion. Do
          not coat or paint over permanently attached hardware items which cannot be removed.

3.4       PRIMING & SEALING OF JOINTS
          Ensure that all priming and sealing to control joints, openings and penetrations is
          complete prior to applying any finishes.

3.5       EXTERNAL ENVIRONMENTAL CONDITIONS
          Ensure that work is conducted within the acceptable temperature range of each product
          as per the applicator and technical data sheets located at
          www.hebel.co.nz/coatings/index.php .

3.6       FINAL APPLICATION SELECTIONS
          Confirm all selections, colours and finishes for Supercoat paint.

3.7       PREPARATION OF SUBSTRATES & CORRESPONDING SURFACES
          Prepare all surfaces to be coated to the requirements of the Supercoat Coating Systems
          Technical manual located at www.hebel.co.nz/coatings/index.php .

3.8       APPLICATION
          Apply Supercoat Paint by brush, roller or spray equipment (if permitted) to a uniform
          thickness and colour to the requirements of the Supercoat Coating System specifications.
          Do not spray on site without express permission from the main contractor.

3.9       SUPERCOAT SPECIFICATIONS
          Refer to Supercoat Coating System Technical Manual located at
          www.hebel.co.nz/coatings/index.php for surface preparation, coating sequence and
          application requirements as they apply to each system. Defective work is to be corrected
          immediately, with any remedial recoating following the system requirements.

3.10      BETWEEN COATS
          Between the layers of the coating system remove any dust pick up, protruding fibres
          and/or coarse particles.

3.11      FINISHED SUPERCOAT PAINT SURFACES
          All finished paint surfaces are to show uniformity of gloss and colour, to have the correct
          thickness for each coat, and be free from painting defects such as tackiness and
          conspicuous brush marks. Finished work shall be free of any chips, scrapes, protrusions,
          or blemishes which do not form part of the required surface finish.
Revision Date December 3, 2008                                                   Spec_006 - Version 2.0

                          Architectural Specification Sheet


3.12        CLEANUP
            Clean all adjoining surfaces, glass and fittings of any paint or coating over-spill.

3.14        HARDWARE REPLACEMENT
            Where hardware has been removed to complete the coatings, it shall be re-installed
            without causing damage to the hardware or any adjoining surfaces.

3.15        RUBBISH REMOVAL
            Remove from the site unused painting and coating materials, equipment and rubbish.

4.0         SELECTIONS

4.1         EXTERIOR COATING SYSTEM
            Refer to the Supercoat online specifications for the different coating systems for each of
            the Hebel Supercrete substrate types. Refer to the Supercoat Technical Manual for
            surface preparations, coating sequence and weather tightness specifications. Refer to the
            Supercoat Training Manual for control joint application flow charts.

Description: Exterior Hebel Supercrete Commercial Industrial Wall System Substrate.

System:     Supercoat Paint over Hebel Supercrete Commercial Industrial Wall Systems.

  Surface Preparation: Refer section 2.45 of the Supercoat Technical Manual (surface preparation of
                               bare Hebel Supercrete CIWS Panels).
 st
1 Coat:                 Supercoat Surface Sealer.


                           * Control Joints to be inserted at this point *
                       Refer Supercoat Training Manual control joint flow chart

 nd                                                st
2 Coat:                 Supercoat Acrylic Paint 1 Coat.
 rd                                                nd
3 Coat:                 Supercoat Acrylic Paint 2 Coat.

				
DOCUMENT INFO