					                                                                COMPASS BAnk reMOte AtM QuiCk StArt Guide
                              COMPASS BANK                                              System Wiring                                                                         8.     Connecting Zone Inputs to XR500N Panel
                      REMOTE ATM SYSTEM INFORMATION                                     All	wiring	must	be	in	accordance	with	NEC,	ANSI,	and	NFPA	70.		Use	non-shielded	      Zones	1-10	are	located	directly	on	the	XR500N	control	panel.		Zones	1	through	8	
                                                                                        22	AWG	wire	for	short	wire	runs	from	the	panel.		Use	non-shielded	18	AWG	wire	        each	terminate	with	a	1k	Ohm	EOL	resistor.		Zones	9	and	10	each	terminate	with	a	
NOTE: PRIOR TO INSTALLING ANY EQUIPMENT FILL IN THE                                     for	longer	wire	runs	from	the	panel.		Refer	to	the	LX-Bus/Keypad	Bus	Wiring	Note	     3.3k	Ohm	EOL	resistor.		Use	the	included	22	AWG	four-conductor	wire	and	connect	
FOLLOWING INFORMATION AND REFER TO THE WORKPLAN AND ALL                                 (LT-2031).		It	is	recommended	that	strain	reliefs	be	used	in	all	locations	where	     each	device	to	the	zone	input	connections	as	listed	in	the	following	table.	
REFERENCE DOCUMENTS LISTED IN SECTION 2.                                                wires	exit	an	enclosure	and	conduit	is	not	used.                                           Zone #                Name         Zone #                  Name
Bank Programming Department Phone Number:                   (800) 239-1122              Reference Documents                                                                           1     ATM Safe Door               6      ATM	Topper	Door	(TANE	60	or	PB-52TC)
                                                                                        As	needed	during	installation,	refer	to	the	wiring	diagram	on	the	back,	the	XR500	            2     ATM	Heat/Seismic            7      spare
Account Number _____________________________________________________                    Series	Installation	Guide	(LT-0681),	XR500	Series	Programming	Guide	(LT-0679),	
                                                                                                                                                                                      3     ATM	Kiosk	Door              8      spare
                                                                                        7060	Keypad	Installation	(LT-0883),	and	any	documentation	included	with	the	
Address ____________________________________________________________                    system components.                                                                            4     ATM Motion                  9      spare
                                                                                                                                                                                      5     ATM	HUA                     10     spare
Phone Number _______________________________________________________                    Also	refer	to	the	Workplan	for	specific	instructions	and	requirements	for	Compass	
                                                                                        Bank Installations.                                                                   9.     Wire the Batteries
Installation Date _____________________________________________________                 Power Reference                                                                             Observe polarity when connecting batteries. Wire all batteries in
                                                                                                 Remove all Power! Remove	all	AC	and	battery	power	from	the	panel	                  parallel. Ensure all battery harness connectors are fully inserted
Installer Name _______________________________________________________                           before installing or connecting any modules, cards, or wires.                      to prevent shorting. The panel’s internal battery cutoff relay
                                                                                                                                                                              automatically turns on when the AC transformer is powered. Refer to Step 10.
Customer Job # ______________________________________________________                   3.   Current Draw
                                                                                                                                                                              DMP requires each battery be separated by a PTC in the battery harness wiring
                                                                                        Combined	current	draw	from	XR500N	Auxiliary	(Terminal	7),	Smoke	(Terminal	11),	
Panel IP Address _____________________________________________________                                                                                                        to protect each battery from a reversal or short within the circuit.
                                                                                        and	LX-Bus	(J22	or	additional	LX-Bus	cards)	must	not	exceed	350mA	in	order	
Gateway Address ____________________________________________________                    to	support	24	hours	standby	operations.		A	separate	power	supply	is	needed	to	        Compass	Bank	requires	each	battery	be	clearly	labeled	with	the	installation	date.		
                                                                                        support	devices	beyond	350mA.		The	350mA	rating	includes	all	devices	as	shown	in	     Mark	the	date	on	the	included	White	labels	and	attach	one	to	each	battery	before	
Subnet Mask ________________________________________________________                    the wiring diagram.                                                                   installing in the enclosures.

                                                                                        4.   Set the XR500N and 341 Enclosure                                                      1. In	the	panel	enclosure,	connect	the	Black	battery	wire	to	panel	terminal	4	
Programming Port: 2001                                                                                                                                                                 negative.
                                                                                        Note:	It	is	not	necessary	to	remove	the	XR500NPCB	when	installing	the	enclosure.		
1.   System Components - Lev. A (KIT-COMP-SMATM)                                        Ensure	strain	reliefs	are	used	for	all	wires	exiting	an	enclosure.                         2. Connect	the	Red	battery	wire	to	panel	terminal	3	positive.
The system package includes the following components:                                   ATM Topper Installations: Do not permanently mount the enclosure. After all                3. Plug	the	panel	Red	and	Black	battery	wires	onto	the	318EXT	Battery	Harness	
  •	 One	XR500N	Panel	in	341	Enclosure	with	transformer                                 connections are made, slide the enclosure into place inside the Topper.                        Extension.
  •	 One	7060	32-Character	LCD	Keypad	(Ivory)                                           ATM Secure Room or Kiosk Building Installations: Mount	the	341	enclosure	with	             4.	 Connect	the	318EXT	Battery	Harness	Extension	to	the	318	Dual	Battery	
  •	 One	696	Keypad	Backbox	(Ivory)                                                     the	XR500N	panel	in	a	dry	place	on	the	wall.		                                                 Harness.		Connect	the	318	Dual	Battery	Harness	to	the	two	12	VDC	7.0	Ah	
  •	 One	3012	Clip-on	Tamper	Switch                                                                                                                                                    Batteries.		Observe	Black	and	Red	polarity	on	all	connections.
                                                                                        5.   Mount the Model 3012 Tamper Switch
  •	 One	306	Tamper	Harness                                                             Attach one Model 3012 Tamper Switch to the lower right side of the panel              10. Installation Completion
  •	 One	318	Dual	Battery	Harness                                                       enclosure. Mount the tamper switch with the button protruding past the enclosure      Ensure	all	devices	are	properly	addressed	and	all	Keypad	Bus	wiring	is	free	of	
  •	 One	318EXT	Battery	Harness	Extension                                               edge.		Plug	the	306	tamper	harness	connector	onto	the	XR500N	panel	J4	Tamper	         grounds,	wire-to-wire	shorts,	AC,	and	RF	noise.		Ensure	all	field	devices	are	
  •	 Two	369	12	VDC	7.0	Ah	Batteries                                                    Header.		Connect	the	306	tamper	harness	wires	to	the	3012	Tamper	Switch	              properly	terminated	to	the	panel	zone	inputs.		Make	note	of	device	addresses.		
                                                                                        mounted	in	the	panel	enclosure.		This	provides	tamper	protection	for	the	panel	       This	is	needed	when	programming	the	zones	to	ensure	proper	operation.
  •	 18	AWG	Non-Shielded	Two-Conductor	Wire	30’	for	Transformer	Connection
                                                                                        enclosure.                                                                            Write	the	battery	installation	date	on	the	enclosed	White	labels	and	place	one	on	
  •	 22	AWG	Non-Shielded	Four-Conductor	Wire	50’	for	Keypad	and	XR500N	Panel	
     Zone Connections                                                                   6.   Network Connection                                                               each	battery.		Mount	the	9	x	12	Document	Storage	bag	on	the	alarm	system	door.		
                                                                                        Using	the	357-10	Ethernet	cable	with	RJ45	connectors,	plug	one	end	of	the	cable	      Place all documentation included with the installation in the storage bag.
  •	 One	9	x	12	Document	Storage	Bag
  •	 One	PB-52TC	Terminal	Door	Contact	—	as	needed	in	ATM	Topper	installations          into	the	XR500N	panel	connector	J1.		Plug	the	other	end	of	the	Ethernet	cable	into	   11. Connect the Transformer and AC Power
                                                                                        the	company	network	LAN/WAN	connection.                                                           DO NOT plug the transformer into dedicated outlet not controlled by a
  •	 One	TANE	60	Door	Contact	—	as	needed	in	ATM	Topper	installations
  •	 One	357-10	Cat-5	Network	Cable	10’	                                                7.   Install the 696 Backbox and 7060 Keypad                                                      switch until all devices are connected to the panel.
                                                                                        Use	the	included	wiring	harness	and,	as	needed,	the	included	22	AWG	                  Note:	Never	share	the	transformer	output	with	any	other	equipment.
  •	 One	sheet	White	adhesive	labels
                                                                                        four-conductor	wire	to	connect	the	DMP	7060	Keypad	bus	wiring	to	the	XR500N	
2.   Reference Information                                                              terminals	7,	8,	9,	and	10.		Observe	wire	colors	when	connecting	and	do	not	use	       As	needed,	use	the	included	18	AWG	two-conductor	wire	to	extend	the	transformer	
                                                                                        shielded	wire.		Mount	the	696	Backbox	where	indicated	by	Compass,	then	install	       wires.		Run	the	transformer	wires	into	the	panel	enclosure	through	a	knockout	and	
System Grounding
                                                                                        the	7060	Keypad	on	the	backbox.		You	can	install	a	maximum	of	16	addressable	         connect the wires to panel terminals 1 and 2. After all components are connected,
Connect	a	14	AWG	or	larger	wire	from	XR500N	panel	terminal	4	to	a	good	Earth	
                                                                                        supervised	devices	on	the	keypad	bus.                                                 plug	the	transformer	into	a	120	VAC	outlet	not	controlled	by	a	switch.		
Ground. DMP recommends a cold water pipe ground, building ground, or a ground
rod. Do not connect to an electrical ground, conduit, sprinkler or gas pipes, or to a
telephone company ground.




         LT-0987 © 2008 Digital Monitoring Products, Inc.
                                                 8312
12. Reset, Initialize and Program the Panel                                                                                                                                                                                     341 Enclosure Cover
After system power-up, perform the following steps to set the panel up for remote
programming.
   1. Reset	the	panel	using	J16	jumper.		Remove	the	jumper	and	store	it	on	one	
        J16	pin	for	future	use.
                                                                                                                                                     Cover Mounting Holes (4 places)
   2. At	the	programming	Keypad	set	to	Address	#1,	enter	6653	and	press	
        COMMAND.	
   3. At	the	INITIALIZATION	menu	press	any	top	row	SELECT	key.
   4.	 Answer	YES	to	all	Initialization	options.		
   5.	 At	the	NETWORK	OPTIONS	menu	press	any	top	row	SELECT	key.                                                                                                                                                                                        341 Enclosure
   6.	 Leave	DHCP	set	to	NO.
                                                                                                                                                                                                                306 Tamper Harness
   7. Enter	the	Local	IP	Address,	Gateway	Address,	Subnet	Mask,	and	Programming	
        Port.                                                                                                                                                                J3
                                                                                                                                                                           Phone                                                              XR500N                                                                            J6
   8. Set	TCP	Communications	to	YES.                                                                                                                                        Line
                                                                                                                                                                                                                                                                                                                             Interface
                                                                                                                                                                                                                                          Command Processor™                                                                   Card
   9. Press	COMMAND	until	STOP	displays.                                                                                                                                                                                               J4       Panel                                                                        Expansion
                                                                                                                                                                                                                                     Tamper
      Note: The information entered is NOT SAVED until you run the STOP
                                                                                                                                                                                                             J1
                                                                                                                                                                                                          Ethernet
                                                                                                                                                                                                                                                                                                                             Connector
      routine.                                                                                                                                                                                                                                                     Resistors
                                                                                                                                                                                                                                                        1.0k Ohm - Zones 1-8




                                                                                                                                                                                                                                                                                                                                                                               Tamper Wires
   10. At	the	STOP	menu	press	any	top	row	SELECT	key	to	save	the	programming                                                                                                                              J23
                                                                                                                                                                                                                          J21                           3.3k Ohm - Zones 9-10
                                                                                                                                                                                              Power R
                                                                                                                                                                                                                     RS-232                             1.0k Ohm - Bell Circuit Supervision
   11. The	system	is	now	ready	to	program	using	Remote	Link™.                                                                                                                                 LED L
                                                                                                                                                                                                      X
                                                                                                                                                                                                                    RED
                                                                                                                                                                                                                          J22
                                                                                                                                                                                                                           LX                              OVC
Fill	out	an	XR500	Series	Programming	Sheet	(LT-0678)	prior	to	programming	to	                                                                                                                                 J10
                                                                                                                                                                                                                                                Output 1
                                                                                                                                                                                                                                                           J2
                                                                                                                                                                                                                                                                            Output 2


ensure	all	the	necessary	information	is	defined	to	properly	program	the	panel.	




                                                                                                                                                                                                                                                                Out1 Out2
                                                                                                                                                                                                                                                                                       J11
                                                                                                                                                                                                                                                   K6                        K7    3                                               J16
                                                                                                                                                                                Battery
                                                                                                                                                                                                                                                                                   4         Outputs 3-6                          Reset
                                                                                                                                                                                                                                     J8                                            5
                                                                                                                                                                                                                                                                                   6


13. Program the 7060 LCD Keypad
                                                                                                                                                                                Start                                               PROG



If	needed,	see	the	Reference	Documents	listed	in	Step	2.	                                                                                                                       AC AC +B –B BELLGND RED YEL GRN BLK SMK GND Z1 GND Z2 Z3 GND Z4 Z5 GND Z6 Z7 GND Z8 Z9+ Z9–Z10+Z10–


   1. On	the	7060	keypad,	hold	down	the	<—	(Back	Arrow)	and	CMD	keys	for	two	                                                                                                    1   2    3   4   5       6     7     8         9   10     11   12 13   14            15 16        17 18        19   20    21 22   23   24   25 26   27   28


       seconds	to	display	SET	BRIGHTNESS.                                                                                                                                                                                                                                                                                                      Use included 22 AWG                            3012
                                                                                                                                                                                                                                                                                                                                               four-conductor wire                            Clip-on
   2. Enter	the	code	3577	(INST)	and	press	CMD.                                                                                                                                                                                                                                                                                                for keypad and panel                           Tamper
                                                                                                                                                                                                                                                        357-10                                                                                 zone connections.
   3. Press	the	left	Select	key	under	KPD	OPT	(Keypad	Options).                                                                                                                                                                                                                                                                                                                               Switch

   4.	 Press	the	CMD	key	to	display	KEYPAD	ADDRESS	and	confirm	the	keypad	is	set	
       to	address	#6.
   5.	 Press	the	CMD	key	to	display	KEYPAD	MODE.		Press	the	Select	key	under	SUP	
       to	configure	the	keypad	for	Supervised	operation.
   6.	 Press	the	CMD	key	to	display	DEFAULT	KPD	MSG.		Press	any	top	row	Select	                                                                                                                                                              14 AWG
                                                                                                                                                                                                                                           Ground Wire
       key.		Refer	to	the	information	at	the	beginning	of	this	document	and	enter	
                                                                                                                                                                                                                                                                                                                                                7060 Keypad
       COMPASS	and	the	5	digit	account	number,	centered,	as	the	default	keypad	
                                                                                                                                                                                                                                                                                                                                                 Address #6
       display. Press the CMD key to accept the name.
   7. Press	the	CMD	Key	to	display	ARM	PANIC	KEYS.		Press	the	Select	key	below	
       the	option	to	display	an	asterisk	next	to	PN	indicating	that	the	Panic	option	
                                                                                                                                                                                                                                                        Earth Ground
       is enabled.                                                                                                    Dedicated
                                                                                                                       Duplex            327
   8. Press	the	CMD	key	until	STOP	displays.		Press	the	right	Select	key	under	STOP	                                   Outlet        Transformer                        Use included 18 AWG                                              318EXT Battery
                                                                                                                                                                        two-conductor wire for                                           Harness Extension
       to	exit	keypad	programming.
                                                                                                                                                                        transformer connection.
                                                                                                                                                                                                                                                                                             Network
14. Work Plan Instructions                                                                                                                                                                                                                                                                   to LAN/WAN
                                                                                                                                                                         Black
Refer	to	the	ADT	Workplan	and	complete	all	instructions	to	download	the	panel	                                                                                                                                                                                                               Connection.
programming, perform test procedures, training instructions with Compass Bank,                                                              318 Battery Harness                                                                 Red

and documentation sign-off.                                                                                                                                                                                                                                                                                                        XR500N Terminals 1-10
                                                                                                                                     PTC
                                                                                                                                                                                                                                                                                                                                     and Keypad Detail
15. Wiring Diagram                                                                                                                                                                                                                                                                                                                                                         To 7060
The	figure	to	the	right	illustrates	the	Compass	ATM	wiring.                                                                                                                                                                                                                                                                                                                Keypad
                                                                                                                                                                                                                                                                                                                         XR500NK
                                                                         Model 369 12 VDC 7.0 Ah Battery                              Model 369 12 VDC 7.0 Ah Battery                                                                                                                                                     Panel 1 2                    3       4    5    6   7   8   9   10
                                                                                                                                                                                                                                                                                                                                          AC   AC     +B      -B   Bell GND RED YEL GRN BLK


                                                                                                                                                                                                                                                                                                                             To




                                                                                                                                                                                                                                                                                                                                                      BLACK
                                                                                                                                                                                                                                                                                                                                                RED
                                                                        [Write the installation date on an included               [Write the installation date on an included                                                                                                                                                Transformer
                                                                          White label and attach to the battery.]                   White label and attach to the battery.]                                                                                                                                                  To Batteries

				