                                                                       Innovations in Cold Storage Roofing


                                                                  Cold Storage History – According to Ken
                                                                  Single-Ply Membrane Usage – Breakdown by Numbers
                                                                  TPO Membrane and System Selections
                                                                  Fleece-Backed Membranes
Innovations in Cold Storage Roofing
                                                                  Transitioning the Roof’s Function – Prepare a Good
   Ken Gingerich | Carlisle SynTec Incorporated                   Foundation Now for Future Alterations




          Ballasted EPDM Assemblies                                   Mech. Fastened/ Fully Adhered EPDM




                                                                       Early 90’s - Mechanically Attached EPDM/PVC/Hypalon over
  1980’s - Ballasted EPDM over Expanded or Extruded Polystyrene               Polyisocyanurate and Phenolic Foam Insulation




          Mechanically Attached TPO                                         Carlisle Cold Storage Systems


                                                                                                     16.6%
                                                                                                 Fully Adhered

                                                                                                          8.3%
                                                                                                        Ballasted

                                                                                        75.1%
                                                                                    Mech. Attached




        Mid 90’s to 2008 - Mechanically Attached TPO over
 Polyisocyanurate, Expanded or Extruded Polystyrene Insulation           Note:

      (TPO accounts for 79% of all cold storage applications)            Represents combined TPO,EPDM and PVC Assemblies




                                                                                                                                          1
                                                                                                                                                        11/11/2008




     National Average of Roofing Materials                                                    2007 Regional Trends
                                                                                                                         EPDM
                2001                                 2007
                                                                                                                                         52%
                                                                                                                                                 10%    PVC
         EPDM                                   EPDM
          36%                                    29%

                                                                                                                                    16%        22%
                                                                                                                       Asphalt                        TPO
                                         PVC
                                         11%                                                                        Northern U.S.
                                                              Asphalt                                                             EPDM           PVC
                                                               31%
   PVC                                                                                                                                   10%
                         Asphalt                                                                                                               12%
   12%                    42%

         TPO                                   TPO
         10%                                   29%                                                                                 42%          36%
                                                                                                                                                       TPO
                                                                                                                        Asphalt



                                                                                                          Southern & Western U.S.




    National Heat Welded Membrane Usage                                                                   TPO

                1996                                   2006                  Blend of Polypropylene & Ethylene
                       CSPE                                                          Propylene Rubber
     TPO
                        11%
     20%                                                         PVC
                                                                 32%    • Thermoplastic/Heat Weldable
                                                                        • Does not require plasticizers
                                                                        • Polymer contains no Chlorine
                                                                        • Product is fully cured

                                     TPO
                                     68%
                       PVC
                       69%




                                   TPO                                              Why has TPO become so popular?


• Auto Industry since                                                          • Energy savings (southern climates)
  early 80’s
                                                                               • Reduce heat island effect – reflectivity
• Roofing installations as
  early as 1990                                                                • Easy to install
• Stable laboratory                                                            • Wider membrane sheets that yield greater fatigue
  physical properties                                                            resistance
• Wide sheet technology                                                        • Wide range of pre-fabricated accessories
• Good puncture
  resistance




                                                                                                                                                                2
                                                                                                                11/11/2008




  Why has TPO become so popular?                                        Why has TPO become so popular?

                   Reflectivity
        PRODUCT                           SRI                           • TPO is 100% recyclable
           White TPO                       110                          • Sheet can be ground into
            Tan TPO                         84                            flakes and used in bottom ply
            Gray TPO                        55                          • Average recycle content of
          White EPDM                       104                            bottom ply is 15%
  Reflective properties based on LEED’s Solar Reflectance Index
                         minimum of 78




             TPO Roofing Systems                                           Mechanically Fastened TPO


                                                                                               Typical Application
          Adhered
                      Ballasted                                                                1. Reinforced TPO
                       1%                                                                         Membrane
          16%
                                                                                               2. Fasteners and
  83%                                                                                             plates
  Mechanically
  Fastened
                                                                                               3. Acceptable
                                                                                                  Insulation
                                                                                               4. Approved Roof
                                                                                                  Deck




TPO Mechanically Fastened Application                                         Wind Uplift Simulation




                                                                  Assembly is pressurized
                                                                   to measure optimum
                                                                         fatigue




                                                                                                                        3
                                                                                                                11/11/2008




     Fastener Thread Profile                                  Fastener Comparison

                                                Condition                V-Type Thread         Buttress Thread

                                                Backout                 3-7 inch pounds        10-16 inch pounds

                                                 Pullout                360-475 pounds           550 pounds
                                             ( 22 ga. steel deck )

                                                                       15 cycles – less than    25 cycles – less
                                              Corrosion                    15% red rust         than 15% red rust

                                                Threads                     60º angle           10º / 45º angle




       Fully Adhered TPO                                 Fully Adhered Application


                    Typical Application
                    1. TPO Membrane
                    2. Fasteners and
                       plates
                    3. Adhesive
                    4. Approved Insulation
                    5. Roof Deck




Bead Applied Insulation Adhesives                                    TPO Accessories




                                                                                                                        4
                                                                                                            11/11/2008




         Fleece Backed Membranes                       Advantages of Fleece Backed Membranes


                                                       • Increased puncture and hail resistance
                                                       • Improved uplift resistance
                                                       • Use of low-rise foam adhesive is VOC compliant
                                                         and acceptable for use in all markets (including
                                                         California)
                                                       • Excellent re-cover option (non-invasive to
                                                         occupied space)




Advantages of Fleece Backed Membranes


• Use of low-rise foam adhesive for insulation
  attachment will eliminate mechanical fasteners
  which decrease insulation value. (NRCA
  estimates 3% - 8% loss in value)


• Use of low rise foam adhesive will seal insulation
  joints and improve thermal efficiency (up to 10%)




  Fleece Backed Membrane Application                      Low-Rise Foam Adhesive Application




                                                                                                                    5
                                                                                               11/11/2008




     Fleece Backed Membranes


           Water Based Bonding Adhesive
           Approved for use on Polyisocyanurate
           Insulation, High Density Wood Fiberboard,
           Glass Faced Gypsum, Oriented Strand
           Board, Plywood, Cellular Lightweight and
           Structural Concrete




                                                       Fleece Backed Membrane set in Hot Asphalt




Fleece Backed Hot Mopped Application                    Asphalt Attached Fleece Back Application




                                                                                                       6
                                                                                                                  11/11/2008




          Coating Considerations                                                 Photovoltaic

                                                                                          Gaining Popularity on
                                                                                          Commercial Rooftop
                                                                                          Installations




                                                           Photo cell process and
                                                           construction practices make
                                                           installation more economical

Acrylic Based Coating Option over Existing Roof Membrane




      Roof Mounted Wind Turbines                               Cold Storage Facility Roof Garden




      On Behalf of Carlisle Syntec

              Thank-You