General
MAGDOS DE / DX solenoid metering pumps combine
the digital technology of state-of-the-art
microprocessors with high-quality mechanics. Due to
its versatility in the area of external control, the new
MAGDOS series is very flexible. The pump can be
supplied with a digital display upon request. The display
shows the different operating conditions and possible
error messages.

The new MAGDOS is available in two basic versions
with the following features:

MAGDOS DE
-   Internal control with continuous stroke frequency
    adjustment from 0 to 100 strokes per minute for
    DE 01...12 and 0...70 strokes per minute for
    DE 20...100
-   Changeover function to external pulse control by
    water meter or other voltage-free contacts
-   Connection for level control with alarm signal

MAGDOS DX
-   Internal control with continuous stroke frequency
    adjustment from 0 to 100 strokes per minute for
    DX 01...12 and 0...70 strokes per minute for
    DX 20...100
-   Changeover function to external control by
    0/4...20 mA standard signal
-   Changeover function to external pulse control by
    water meter or other voltage-free contacts
-   Pulse multiplication with factors 2/4/8/16/32/64                    Control unit
-   Pulse division with divisors 2/4/8/16/32/64                         The main part of the control unit is a microprocessor
-   Connection for level control with alarm signal                      which controls the stroke frequency with digital
                                                                        accuracy. The various control possibilities allow the
                                                                        pump to be adapted to practically all requirements of
As an alternative, both versions can be supplied with                   home water supply, water and waste water treatment
warning alarm relay and digital display. The metering                   as well as industrial pocesses. The electronic control
capacities range between 0.1 l/h at 10 bar and                          unit is available in two basic versions with functions
115 l/h at 1.5 bar. Refer to MB 1 02 20 / 6-7 for exact                 described below.
performance curves, the output per pulse is set by
changing the stroke length via the stroke adjustment
knob.
                                                                          Functions              X=standard      Magdos DE Magdos DX
The pumps are designed to meet the requirements of                                               O=optional
DVGW-DIN 19635 and CSA/UL.                                                Level control with alarm signal           X          X

Magnetic drive                                                            Low level indication                      X          X
The stroke movement of the metering diaphragm is                          Warning alarm relay                       O         O
produced by a d.c. solenoid. Due to the infinitely
                                                                          Internal control 0...100%                 X          X
adjustable stroke stop, it is possible to set a stroke of
0-6 mm, depending on the pump size. Reduction gears                       External control           contact        X          X
or rotating parts are not used, resulting in high reliability
                                                                                                     0...20 mA       -         X
and low maintenance work. The armature runs in a
maintenance-free DU bushing with PTFE coating and                                                    4...20mA        -         X
additional silicone grease lubrication.
                                                                          Pulse division / multiplication            -         X

                                                                          Stroke adjustment                         X          X
                                                                          Digital display                           O         O




                                                      Lutz-Jesco GmbH
                                          Improved changes are always reserved without notice.
                                                                                                            MB 1 02 20 / 2




                                                                                                                                   MAGDOS DE / DX
Water meters                                                         In order to avoid interference or false pulses, do not
The MAGDOS DE/DX can be controlled by any water                      mount the pump directly on the water meter. If adapters
meter with voltage-free contacts. For water meters                   which ensure a distance of 50 mm are used, direct
which pulse too fast or too slow for the pump, the pulse             mounting is possible. With this kind of installation, pulse
division or multiplication function of the pump can be               division or multiplication must not be used. It is
used to adapt the pump to the water meter. In the case               recommended to mount the pump on the chemical tank
of pulse division, the maximum stroke frequency is                   or to the wall.
restricted (see MB 1 02 20/4).

Technical data
                                                 DE/DX 01...12                                     DE/DX 20...100
Electrical connection                            230 V~                   115V~                    230V~            115V~
                                                 50/60 Hz                 50/60 Hz                 50/60 Hz         50/60 Hz
Power supply cable                               2 m with                 2 m with UL/             2m with          2m with UL/
                                                 standard plug            CSA plug                 standard plug    CSA plug
Power consumption
at max. stroke frequency                         30W                      33W                      70W              66W
Fuse                                            T 0.8 A                   T 1.6 A                  T2A              T4A
Max. stroke frequency                           100                                                70
Current consumption during stroke                2.3 A                    3.6 A                     4.1 A           7.4 A
Protection class                                                                                IP 65
Insulation class                                                                                   F
Input pulse duration                                                                          min. 30 ms
Solenoid excitation time per pulse               60ms                     80ms                     160ms            190ms
Warning alarm relay with                                                                      250V AC, 2.5 A
changeover contact                                                                            30 V DC, 2.5 A
Voltage to low level probe                                                                      5 V DC
Voltage to pulse input                                                                         5 V DC
Impedance to 0/4...20mA input                                                                  150 Ω
Max. suction lift                                3m Ws*                                            1.2m Ws
Max. ambient temperature                                                                        40° C
Max. temperature of medium     PVC                                                              35° C
to be metered          PP, PVDF, SS                                                             50° C
Weight                     Plastic              approx. 2.9 kg                                     12.5 kg**
Head                       Stainless steel      approx. 3.5 kg                                     20 kg**
                                                * DE / DX 8 max. 2m Ws                             **DE/DX 20 10.5 kg or 12 kg,
                                                * DE / DX 12 max. 1.2m Ws                            respectively

Cross section of MAGDOS DE / DX 01...12
                                             Separation chamber Magnetic drive Control unit

                Discharge
                valve

                Metering
                head


                Suction
                valve



                Drain pipe



                                                   Lutz-Jesco GmbH
                                       Improved changes are always reserved without notice.
                                                                                     MB 1 02 20 / 3




                                                                                                                    MAGDOS DE / DX
Control panel MAGDOS DE                                 1 Power supply cable, 2 m, with plug

                                                        2 Cable for warning alarm relay, 1.5 m

                                                        3 3.5 mm jack for level probe connection;
                                                          can be used by 2-pin plug for simple low level
                                                          indication or by 3-pin plug for low level indication
                                                          with alarm signal.

                                                        4a Cable or connector socket for pulse input
                                                        4b Cable or connector socket for pulse and d.c. signal
                                                           input

                                                        5 Adjusting knob for metering capacity per stroke

                                                        6 Locking screw

                                                        7 Stroke frequency adjustment with changeover
                                                          switch for external control

                                                        8 Digital display

                                                        9a Red LED
                                                           - blinks slowly in the case of alarm signaling and
                                                             lights permanently if the tank is empty. Pump is
                                                             then stopped automatically.
                                                        9b - like a, plus fast blinking if, in the case of
                                                             4...20 mA d.c. signal control, the input signal is
                                                             less than 4 mA (e.g. due to a cable rupture).
                                                           - blinks slowly, if selector switch (12) is set to "0"
                                                             (pump is not metering).

                                                        10 Green LED
                                                           lights if power supply voltage is applied and goes
Control panel MAGDOS DX                                    out for a short time during the metering stroke.

                                                        11 Calibration table

                                                        12 Selector switch for external control
                                                           Pulse 1:1 1
                                                           Pulse division 2 / 4 / 8 / 16 / 32 / 64
                                                           Pulse multiplication 2 / 4 / 8 / 16 / 32 / 64
                                                           Current input 0...20 mA or 4...20 mA
                                                           Pump stop "0"




                                      Lutz-Jesco GmbH
                          Improved changes are always reserved without notice.
                                                                                                            MB 1 02 20 / 4




                                                                                                                                      MAGDOS DE / DX
External control                                                      Level control
a) Contact                                                            To protect the pump against dry operation, level probes
In order to protect the pump against overheating, the                 with or without alarm signaling can be connected
maximum input frequency is limited to 70 or 100 pulses/               (3.5 mm jack). They also provide self-diagnostics. A
minute. If the input frequency is higher, each third or               dummy plug is inserted if no level switch is used.
fourth metering stroke is not carried out. Therefore
external pulse transmitters should be designed so that                Warning alarm relay
the maximum stroke frequency is not exceeded.                         With the warning alarm relay (voltage-free changeover
                                                                      contact), the following alarm states can be transmitted:
b) Contact with pulse division/multiplication
Incoming control pulses can be divided or multiplied                  -     "Tank empty" if a simple level probe is
by setting the selector switch correspondingly.                             connected.

                                                                      -     "Tank almost empty" if a level probe with alarm
                                                                            signaling is connected. (In this case "Tank
                                  1)                                        empty" cannot be indicated.)

                                                                      -     If, for d.c. signal control with 4...20mA, the input
                                                                            signal is less than 4mA (e.g. cable breakage).
 2)                                                 3)
                                                                      -     Power supply failure

                                                                      Digital display
                                                                      The display indicates the different operating
                                                                      conditions and possible error messages.

                                                                          Display              Meaning
                                                                          080                  Stroke frequency of 80 per minute
1)     Ratio 1:1                                                                               with operating condition internal
                                                                                               control or d.c. signal control
2)     Pulse multiplication                                               1.1                  Operating condition external control
       e.g. setting to 8                                                                       with contact ratio 1:1
       -- one control pulse results in 8 metering
       strokes                                                            1.16                 Operating condition external control
       Note: The metering strokes are carried out                                              with pulse multiplication factor 16
       at maximum stroke frequency.                                       8.1                  Operating condition external control
                                                                                               with puls division divisor 8
3)     Pulse division
                                                                          E-L                  "Tank empty" message
       e.g. setting to 16
       -- one metering stroke is carried out after                        I-E                  Input signal < 4mA with
       16 incoming control pulses.                                                             4...20mA control
                                                                                               (e.g. cable breakage)
When setting pulse division to 32, the maximum stroke                     OFL                  Input signal > 20mA with
frequency is reduced to 70 strokes/min.; with divisor                                          0/4...20mA control
64, it is max. 36 strokes/min..
                                                                          OFF                  with selector switch set to "0"
c) Standard signal 0/4...20mA
To control the pump by standard signal 0/4...20 mA,
operate the selector switch. The linearity of converting
the signal into stroke frequency is +/- 3%. If the signal
source is not isolated, it must be ensured that the signal
line does not come into contact with ground (separate
isolators available upon request!).
Note: To avoid accidental metering after the process
is finished, provide an electric or hydraulic interlocking
system.




                                                    Lutz-Jesco GmbH
                                        Improved changes are always reserved without notice.
                                                                                                     MB 1 02 20 / 5




                                                                                                                             MAGDOS DE / DX
Dimensions DE/DX 01...12
                                                                                   approx.
                                                                                       approx.




For "L" dimensions, see MB 1 02 20 / 10.




Pump base                                    Adapter
Part No.: 21589                              Part No.: 21801




                                                                                                 Adapter for mounting on
                                                                                                 standard tanks (min. 60l)
                                                                                                 Part No.: 29775

                                                                                                 for mounting on 45l tanks
                                                                                                 Part No.: 32608




                                                                                                         Wall bracket
                                                                                                         Part No.: 26502

                                                                                                         Mounting kit
                                                                                                         with dowels
                                                                                                         Part No.: 25155




                                                Lutz-Jesco GmbH
                                    Improved changes are always reserved without notice.
                                                                                          MB 1 02 20 / 6




                                                                                                                 MAGDOS DE / DX
Dimensions DE/DX 20...100




Dimensions

 Model       Material    A       B       C          D
 DE/DX       PVC         155     89      310        87
 20          1.4571      135     89      310        87
 DE/DX       PP          280     152     345        105
 40/100      1.4571      280     148     310        105

 For "L" dimensions, see MB 1 02 20 / 11.




                            Pump base
                            Part No.: 21589




                                                                                               Wall bracket
                                                                                               Part No.: 26502



                                               Lutz-Jesco GmbH
                                   Improved changes are always reserved without notice.
                                                                                           MB 1 02 20 / 7




                                                                                                             MAGDOS DE / DX
Performance curves
The performance of the pump depends on the
viscosity of the medium and hydraulic installation
conditions. The curves refer to water at 18° C and a
suction lift of 0.6 m.



    scale                                                             scale




                                         ml/pulse                                                 ml/pulse




     scale                                                            scale




                                        ml/pulse                                                  ml/pulse




    scale                                                              scale




                                        ml/pulse                                                  ml/pulse
                                            Lutz-Jesco GmbH
                                    Improved changes are always reserved without notice.
                                                               MB 1 02 20 / 8




                                                                                    MAGDOS DE / DX
scale                                       scale




           ml/pulse
                                                                       ml/pulse




scale                                         scale




                                                                      ml/pulse
            ml/pulse




                                                                     strokes/min




                                                                         ml/pulse

                    Lutz-Jesco GmbH
        Improved changes are always reserved without notice.
                                                                                                 MB 1 02 20 / 9




                                                                                                                           MAGDOS DE / DX
Selection tables                                                        5
In order to be able to offer the user a variety of pumps,
these have been divided into the main functional                        4                                              1
groups. They can thus be assembled according to the
user's individual requirements.
                                                                        3                                              2

 1    Drive      2 Control unit         3 Head

 4    Valves     5 Connections                                          4
The numbers on the pump drawing refer to the relevant
selection tables.                                                       5




 1 Drive                                             3 Head

     Pumpe                                           Pump                       Material
     type:      230 V~         115 V~                 type:                PMMA PVC                    PVDF    1.4571
        01      32956          33053               PP                      01 32962                     —
        03      32732          32953               —     — –                      03                    —      25188*
        07      32719          33054               2811525189 –
         2      32733          32943                    07         —       25188* 28115               25189      –
         4      32720          33055                      2        —       23809     28117            23812      –
         8      32722          33056                      4        —       23809     28117            23812      –
        12      32723          33057                      8        —       23810     28119            23813      –
        20      34338          34341                    12         —       23811     29178            23814      –
        40      34339          34342                    20         —       23909     23911            23911      –
       100      34340          34343                    40         —          —      23727            23727    23721
                                                       100         —         —       23728            23728    23722
                                                   * with automatic head venting;
                                                      for further head venting equipment,
                                                      see MB 1 33 00.



4 Valves
Housing material                  PVC                   PP                       PVDF               1.4571
Sealing material            Hypalon Viton         Hypalon Viton                   Viton Hypalon Viton    AF    PTFE
01... Double-ball       S      —    29434            —     —                     33700    —     28459    —       —
03 valves               D      —    29435            —     —                     33701    —     28461    —       —
07... Double-ball       S      —    20890            —     —                     33703    —       —      —     24029
12 valves               D      —    20891            —     —                     33704    —       —      —     24030
      Spring-loaded     S      —    25087            —     —                     34370    —       —      —     25089
      valves            D      —    25088            —     —                     34371    —       —      —     25090
20 Double-ball          S    18187 18185             —     —                       —      —       —    26967     —
      valves            D    18188 18186             —     —                       —      —       —    26968     —
      Spring-loaded     S    25161 25162             —     —                       —      —       —    28775     —
      valves            D    27516 27517             —     —                       —      —       —    28776     —
40... Double-ball       S      —      —            26841 26842                     —    26843 27652 29694        —
100 valves              D      —      —            27356 27357                     —    27358 27655 29695        —
      Spring-loaded     S      —      —            26845 25707                     —    26844 25797 29696        —
      valves            D      —      —            27353 27354                     —    27355 27654 29697        —




                                                     Lutz-Jesco GmbH
                                         Improved changes are always reserved without notice.
                                                                                                          MB 1 02 20 / 10




                                                                                                                                  MAGDOS DE / DX
2     Control unit

            Pump                                    Control types
Voltage     type:         DE       DE...S      DE...D DE...SD     DX                       DX...S   DX...D DX...SD
230 V ~        01        33931     33938       33945 33952 33959                           33966    33973 33980
               03        33932     33939       33946 33953 33960                           33967    33974 33981
               07        33933     33940       33947 33954 33961                           33968    33975 33982
                 2       33934     33941       33948 33955 33962                           33969    33976 33983
                 4       33935     33942       33949 33956 33963                           33970    33977 33984
                 8       33936     33943       33950 33957 33964                           33971    33978 33985
               12        33937     33944       33951 33958 33965                           33972    33979 33986
               20        34290     34293       34296 34299 34302                           34305    34308 34311
               40        34291     34294       34297 34300 34303                           34306    34309 34312
              100        34292     34295       34298 34301 34304                           34307    34310 34313
115 V ~        01        33987     33994       34001 34008 34015                           34022    34029 34036
               03        33988     33995       34002 34009 34016                           34023    34030 34037
               07        33989     33996       34003 34010 34017                           34024    34031 34038
                 2       33990     33997       34004 34011 34018                           34025    34032 34039
                 4       33991     33998       34005 34012 34019                           34026    34033 34040
                 8       33992     33999       34006 34013 34020                           34027    34034 34041
               12        33993     34000       34007 34014 34021                           34028    34035 34042
               20        34314     34317       34320 34323 34326                           34329    34332 34335
               40        34315     34318       34321 34324 34327                           34330    34333 34336
              100        34316     34319       34322 34325 34328                           34331    34334 34337
DE:        Internal pulse 0...100 or 0...70 strokes/min, external pulse 1:1, low level with alarm signaling and master alarm
DE...S:    same as DE plus warning alarm relay
DE...D:    same as DE plus digital display
DE...SD:   same as DE plus warning alarm relay and digital display

DX:        Internal pulse 0...100 or 0...70 strokes/min, external pulse 1:1, pulse division and multiplication,
           0/4...20mA signal input,
           low level with alarm signaling and master alarm
DX...S:    same as DX plus warning alarm relay
DX...D:    same as DX plus digital display
DX...SD:   same as DX plus warning alarm relay and digital display




5 Connections DE/DX 01...12

DN Fig. Dim. Dim. Dim. L      Part No.
         di da PVC 1.4571 PVC PVDF 1.4571                                                      A                    B
4   A 4       6  23   —  20975 29387     —                                                   Tubing              Hose liner
                                                                                           connection
4   E — 6         —   43   —     —     24959
6   A 6       8  30   —  25176 —         —
6   A 6 12 13         —  32980 33161     —
6   B 6 12 30         30 23092 —       23093
6   C — 10 15         —  23087 —         —
8   C — 12 15         —  23089 —         —
6   D — G1/4 20       20 23088 29179 22999
6   E — 10 —          46   —     —     23090
8   E — 12 —          46   —     —     23091
                                                                                    C                    D             E
                                                                                Cemented             Threaded    (Ermeto) screw
                                                                                connection          connection     connection



                                                       Lutz-Jesco GmbH
                                           Improved changes are always reserved without notice.
                                                                                                        MB 1 02 20 / 11




                                                                                                                                MAGDOS DE / DX
       A                         B                                   B1                                C
     Tubing                                  Hose liner                                            Cemented
   connection                                                                                      connection




          D                     D1                                                            F

              Threaded connection                                                Flanged connection




5 Connections DE/DX 20...100

Pump          Fig.   DN   Conn. dim.          di        da                    L                   PVC           PP   St.steel
type                          D                                    PVC        1.4571                                 1.4571
DE / DX       A      4      G 3/4          4            6           35          —             19480           —         —
20            A      6      G 3/4          6           12           55          —             19175           —         —
              B      6      G 3/4          6           12           30          —             23342           —         —
              B1     6      d 20           6           12           —           30              —             —      23426
              C      6      G 3/4          6           10           15          —             25167           —         —
              C      8      G 3/4          —           12           15          —             27518           —         —
              C      10     G 3/4          —           16           17          —             25625           —
              D      6      G 3/4          6          G 1/4         20          —             25165           —        —
              D1     6      d 20           6          G 1/4         ---         20              —             —      82105
DE / DX       B      10    G 1 1/4         9           15           41          41            25921           —      25925
40 - 100      B      15    G 1 1/4         16          24           50          50            25936           —      25935
              C      10    G 1 1/4         —           16           22          —             27672           —        —
              C      15    G 1 1/4         —           20           22          —             25937           —        —
              C      20    G 1 1/4         —           25           22          —             33318           —        —
              D      10    G 1 1/4         —          G 3/8         22          22            25930         33797    27.037
              D      15    G 1 1/4         —          G 1/2         22          22            25943         33798    25944
              D      20    G 1 1/4         —          G 3/4         —           22              —             —      27689
              F      15    G 1 1/4         —           15           47          53            25956           —      25957

                                                   Lutz-Jesco GmbH
                                       Improved changes are always reserved without notice.
                                                                                                      MB 1 02 20 / 12




                                                                                                                           MAGDOS DE / DX
Installation example                                                       Legend

                               10
                                                                            1 MAGDOS metering pump            MB 1 02 20
                                                                            2 Suction line                    MB 1 22 00
                                                                            3 Electric agitator               MB 1 36 00
                                                              9             4 Tank                            MB 1 20 01
    7
                           8             1                                  5 Relief valve                    MB 1 25 01
                                                                            6 Diaphragm shutoff valve         MB 1 24 05
                  6         5
                                                   3                        7 Injection nozzle                MB 1 23 01
                                                                            8 Pulsation dampener              MB 1 27 01
                                                                            9 Switch box
                11
                                    12                                     10 Water meter                     MB 1 37 01
                4                   2                                      11 Back pressure valve             MB 1 25 01
                                                                          12 Diaphragm leak detector
                                                                             "Leak-Check"                     MB 1 31 01


*   In the case of effervescent media, it is recommended to
    provide the pump with a positive suction head.


Example of an order                                                       Place the order as follows:
A solenoid metering pump controllable by water meter                      MAGDOS DE 4 S consisting of:
contacts is required for metering 0.4 ml phosphate per
stroke against 8 bar. For remote monitoring from a
central control station, a warning alarm relay is to be                       1 Drive                            32720
provided.
                                                                              2 Control unit                     33942
Pump selection
a) Based on the flow rate of 0.4 ml/stroke, the                               3 PVC metering head                23809
   MAGDOS 4 is determined according to the
                                                                              4 PVC suction valve                20890
   performance curve (MB 1 02 20/6). Because of the
   required warning alarm relay, the control unit of                          4 PVC discharge valve              20891
   pump type DE4S, Part No. 33942, must be chosen
   from table 2.                                                              5 Suction connection 4/6           20975
b) Select drive Part No. 32720 from table 1.
                                                                              5 Discharge connection 6/12        32980
c) Part No. 23.809 is chosen as metering head (PVC
   is compatible with phosphate).
d) For the suction and discharge valves, select Part
   No. 20.890 and No. 20.891 (PVC and Viton are
   resistant).
e) See table 5 for suction connection Part No. 20975
   for ø 4/6 tubing and discharge connection Part No.
   32980 for ø 6/12 tubing.
f) The suction line, preferable with level control, can
   be found in MB 1 22 01.




                                                         Lutz-Jesco GmbH
                                             Improved changes are always reserved without notice.

								
To top