Centeron Distribution Management System by eld18221

VIEWS: 58 PAGES: 2

									Centeron Distribution Management System
            T   H E   S   T R E N G T H   O F   E   X P E R I E N C E   .   T   H E   P   O W E R   O F   I   N N O VAT I O N        .




   Gauge-Based Monitor
   Substance-specific, programmable Centeron monitors accurately
   measure tank content levels and send data to the controller
   using robust DSSS wireless technology. The Gauge-Based
   Monitor includes sensing and FCC license-free RF telemetry
   capabilities. Gauge magnetically couples to existing float level
                                                                                  [   Gauge-Based Monitor:
                                                                                            Install and Forget It.                                 ]
   system. Low-cost installation and no maintenance.
       • Safe, easy installation and operation due to non-intrusive,
         magnetically-coupled gauges
       • No field calibration
       • For propane, anhydrous ammonia and cryogenic liquids
       • Reports tank level and temperature
       • Field replaceable gauges


   Gauge-Based Monitor Specifications:
       • Temperature range: -40°C to +85°C
       • Environmentally sealed — designed to NEMA 4/IP-65
       • Non-intrusive, magnetically-coupled gauges                                                               Exceptional DSSS technology
       • Intrinsically safe for use in Class I, Division I,                                                         is superior to narrow band
         Group D Areas                                                                                                  systems, resulting in more
       • Up to five year battery life, based on programmable                                                              reliable communications.
                                                                                                                           So advanced, it’s already
         update rate
                                                                                                                           the recipient of 12 patents,
       • Supports small residential tanks                                                                                  with additional pending.
                                                             [ Noise Level]
       • Hysterisis: ± 5%
       • Self diagnostics (including battery life monitor)
       • Easy installation




                                                                                                              [   Narrow Band Waveform
                                                                                                                  Spread Waveform                 ]
       [   Get the facts from the engineering experts.
           Call 1-800-237-7429 and speak directly
            to a Robertshaw applications engineer.       ]
            Gauge-based Monitor
                                                                                                                (2.143)
                                                      (5.1)
                                               DISABLE MAGNET
                                                                                                                130º



                                                                                                                                                  50º

               MAGNETIC
               TANK                                                                   (Ø2.927)
               ATTACHMENT

                                                                                                 (Ø3.654)                                        50º


               DESIGNED
               TO MATE WITH                                                                                               3 X ACR PHILLIPS
               PACKARD                                                                                                    HEAD SCREWS
               CONNECTION                                                                                                 TIGHTEN TO
               150.2 F-3                                                                                                  10 +/- 2 IN LB




                                                                                                                    Gauge-based Monitor
              Dial Face Assembly                                                                  0         0     4          4 Minute transmit interval
                                                                                                  0         3     0         30 Minute transmit interval
                                                                                                  0         6     0         60 Minute transmit interval
                                                                                                  1         2     0        120 Minute transmit interval
                                                                                                  2         4     0        240 Minute transmit interval

                                                                                                                                 E           EBMP
                                                                                                                                 A           ASP
                 ROCHESTER GAUGES. INC. 6200 SERIES
                 TWINSITE SENDER
 60.00           1 REQUIRED
                                                                                 G M                                                         I 0 0 0 0              F 9          0 0

                                                                                                                           Dial Face Assembly
                 .250 PLASTIC CORRUGATED
                 CABLE ARMOR                                                                                                     J           Rochester Junior Gauge Assembly
                                                                                                                                 S           Rochester Senior Gauge Assembly
                                                                                                                                 A           JY Taylor Style A Gauge Assembly
                                                                                                                                 B           JY Taylor Style B Gauge Assembly
                                                                                                                                                    0   2     2-Ft. Cable
                 PACKARD                                                                                                                            0   5     5-Ft. Cable
                 CONNECTOR
                 150.2 F-3                                                                                                                          1   0     10-Ft. Cable

DIMENSIONS ARE IN INCHES
                                                                                                       G S H
                                                                      Note: Both monitor and face assembly parts must be ordered together.


                    ETL Marked Intrinsically Safe apparatus for use in Class I, Division I,                            FCC Part 15 Registered: NU9TX0625-0200
                    Group D applications, conforming to ANSI/UL 913-1988 Standard.
                                                                                                                       This device is manufactured by Robertshaw Controls Company,
                    This device complies with Part 15 of the FCC rules. Operation is subject                           in Maryville, TN USA under the following US Patents: 4,977,577;
                    to the following two conditions: (1) This device may not cause harmful                             5,067,136; 5,119,396; 5,265,120; 5,406,217; 5,457,713; 4,581,606;
                    interference and (2) This device must accept any interference received,                            Patents Pending in the US and other countries.
                    including interference that may cause undesired operation.




                                           U.S.A. – Robertshaw Industrial Products Division, 1610 Mustang Drive, Maryville, Tennessee 37801 • 800-237-7429
                                                                                  Technical Support • 865-981-3118
                                                                          www. robertshawindustrial.com • www.centeron.net

								
To top