To je URSP predloga - DOC

Document Sample
To je URSP predloga - DOC Powered By Docstoc
					         DETENTIONS IN PORT OF KOPER IN THE YEAR 2008


     1              2           3          4              5                    6
Date &       Vessel Name,     Flag     Owners       Classification          Summary
Place of     Type, IMO No &            Operator     Society
Detention    GT                       Charterers
15/01/2007   AP LIGHT       Cambodia Partner Ltd.   Posski Rejstr    Detained for 350 days.
                                                    Statkov          24 recorded deficiencies.
Koper        General cargo            Rostov on                      Safe manning certificate
                                      Don                            expired. IOPP certificate
             7628863                                                 expired. Chart 1471
                                      Russia                         missing. Wheelhouse
             3419                                                    bulkhead corroded
                                                                     through. Main magnetic
                                                                     compass with big air
                                                                     bubble. Alleyway
                                                                     threshold corroded
                                                                     through. Battery room
                                                                     bulkhead corroded
                                                                     through. Three lifebuoys
                                                                     in bad condition. Second
                                                                     eng. cabin bulkhead
                                                                     corroded through. Galley
                                                                     air vent corroded
                                                                     through. On davits limit
                                                                     switches sized. Top of
                                                                     tank no 2 STB cracked.
                                                                     Wing tank no 2 bulkhead
                                                                     corroded through.
                                                                     Windlass oil leaking.
                                                                     Hatch covers hydraulic
                                                                     pipes leaking.
                                                                     Emergency fire pump
                                                                     engine oil leaking. DG no
                                                                     1 fuel leaking alarm
                                                                     inoperative. Both cold
                                                                     room compressors
                                                                     inoperative. No sufficient
                                                                     food quantity on board.
                                                                     Crew does not use
                                                                     personal protective
                                                                     equipment. ME cooling
                                                                     water leaking. Due to
                                                                     improper lub oil ME with
                                                                     insufficient power. ISM
                                                                     maintenance of ship and
                                                                     equipment failed.
27/10/2007   SLAVUTICH- 10 Monteneg Nimont Ltd.     Montenegro       Detained for 5 days.
                           ro                                        35 recorded deficiencies.
Koper        General cargo          Bar                              In minimum safe
                                                                     manning certificate
             8841498                  Montenegro                     master missing. In IOPP
                                                                     certificate bilge tank
             2.193                                                   recorded twice. Sludge
                                                                     and bilge tanks are full.
                                                                     Main magnetic compass
                                                                     missing. Spare batteries
                                                             for 2 way VHF expired.
                                                             Radio room bulkhead
                                                             corroded through. ER
                                                             skylight corroded
                                                             through. PS life raft
                                                             improperly lashed.
                                                             Funnel corroded through.
                                                             EDG room bulkhead
                                                             corroded through. Self
                                                             igniting lights inoperative.
                                                             Boat swain cabin
                                                             bulkhead corroded
                                                             through. Sewage
                                                             discharge connection
                                                             improper. All navigational
                                                             lights with improper
                                                             lights. Main fire line
                                                             temporary repaired.
                                                             Chief engineer cabin
                                                             corroded through. Front
                                                             bridge bulkhead
                                                             corroded through. Chief
                                                             engineer cabin window
                                                             glass cracked. Seaman
                                                             cabin bulkhead glass
                                                             cracked. STB entrance
                                                             door corroded through.
                                                             On standard discharge
                                                             connection additional
                                                             pipe fitted. Spare cabin
                                                             bulkhead corroded
                                                             through. FCSL deck
                                                             corroded through. Eight
                                                             hatch coaming frames
                                                             cracked. On FCSL bell
                                                             missing. In tank 2C five
                                                             deck support pillars and
                                                             one beam corroded
                                                             through. In tank 4 PS
                                                             eleven frames and 2
                                                             beams corroded through.
                                                             In tank 5 STB two deck
                                                             support pillars cracked
                                                             and corroded through. In
                                                             tank 6 STB two deck
                                                             supporting pillars
                                                             corroded through. On PS
                                                             ME jacketed lines
                                                             disconnected. On both
                                                             main engines fuel
                                                             leaking alarms
                                                             inoperative. ER bilge full
                                                             of DO. QCV on fuel tank
                                                             blocked with wire. ER fire
                                                             sensors inoperative. ISM
                                                             maintenance of ship and
                                                             equipment failed.
04/01/2008   GREEN    Panama   Alemar s.r.l.   Istmus Bureau Detained for 4 days.
             FLOWER                            of Shipping   1 recorded deficiency.
Koper                          Napoli                        Lost of stability after
             General cargo             Italy                     loading lumber on deck.

             7397971

             1.628
08/01/2008   BURAKBEY        Malta     Genta Genel   Lloyd's     Detained for 2 days.
                                                     Register    13 recorded deficiencies.
Koper        General cargo             Istanbul                  Air condition room air
                                                                 vent corroded through.
             8408428                   Turkey                    Magnetic compass with
                                                                 air bubbles. Artificial
             2.683                                               opening in funnel not
                                                                 welded but filled with
                                                                 silicon. Paint room air
                                                                 vent cover's frame
                                                                 corroded through. Dogs
                                                                 for paint room air vent
                                                                 cover missing. Dogs on
                                                                 CO2 room air vent cover
                                                                 missing. Boatswain store
                                                                 room air vent corroded
                                                                 through. In FCSL several
                                                                 electric cables not
                                                                 insulated. STB WB11 air
                                                                 pipe corroded through.
                                                                 Hatch covers hydraulic
                                                                 pipes leaking. Boiler
                                                                 protection fire line
                                                                 disconnected. Bilge
                                                                 under diesel generators
                                                                 to be dried and cleaned.
                                                                 ME fuel leaking alarm
                                                                 inoperative.
14/01/2008   CAPETAN         Bahamas   Tomasos       Lloyd's     Detained for 2 days.
             COSTIS                    Brothers      Register    9 recorded deficiencies.
Koper                                                            No procedure in place to
             Oil tanker                Piraeus                   inform PSC that the ship
                                                                 is eligible for MEI, PS
             8806888                   Greece                    standard discharge
                                                                 connection with improper
             25.368                                              flange, Emergency exit
                                                                 locked, Emergency fire
                                                                 pump with insufficient
                                                                 pressure, Fuel leaking
                                                                 alarm on DG1 & DG3
                                                                 inoperative, ME fuel
                                                                 leaking alarm
                                                                 inoperative, Lifeboat
                                                                 winch brake wire torn,
                                                                 On STB lifeboat
                                                                 sprinklers inoperative.
                                                                 Abandon drill failed.
15/01/2008   MARAS           Sierra    El-Amira      Dromon      Detained for 8 days.
                             Leone                   Bureau of   24 recorded deficiencies.
Koper        General cargo             Ravenna       Shipping    Navigational lights alarm
                                                                 inoperative. Spare side
             7015509                   Italy                     navigational lights with
                                                                 improper corrugated
             1.090                                               glasses. ER air vent
                                                                 cover sized and without
                                                                     gaskets. Cook cabin
                                                                     bulkhead corroded
                                                                     through. Front bridge
                                                                     bulkhead temporary
                                                                     repaired with block of
                                                                     concrete. All 4 air pipes
                                                                     on WB5 tanks corroded
                                                                     through. Hatch covers
                                                                     corroded through. Hatch
                                                                     coaming 2 inner frame
                                                                     corners corroded
                                                                     through. Air pipes on
                                                                     WB4 PS & STB corroded
                                                                     through. Air pipes on
                                                                     WB3 PS & STB corroded
                                                                     through. Hatch coaming
                                                                     1 both inner corner
                                                                     plates corroded through.
                                                                     Air pipes on WB2 PS &
                                                                     STB corroded through.
                                                                     Air pipes on WB1 PS &
                                                                     STB corroded through.
                                                                     FP air pipe corroded
                                                                     through. PR air vent
                                                                     corroded through. On PS
                                                                     hull corroded through.
                                                                     Rope store hatchway
                                                                     corroded through. In
                                                                     FCSL several frames
                                                                     corroded through. In
                                                                     FCSL one beam
                                                                     cracked. RR air vent
                                                                     corroded through. STB
                                                                     FWD hold air vent
                                                                     corroded through.
                                                                     Steering gear emergency
                                                                     exit blocked. Emergency
                                                                     fire pump insufficient
                                                                     pressure. ISM
                                                                     maintenance of ship and
                                                                     equipment failed.
18/01/2008   FARWA           Libya   North African   International   Detained for 9 days.
                                     Maritime        Naval Survey    33 recorded deficiencies.
Koper        General cargo           Transport       Bureau          EIAPP certificate
                                                                     missing. ORB not
             7633193                 Tripoli                         appropriate. Chart 1471
                                                                     missing. Navigational
             2.003                   Libya                           lights alarm inoperative.
                                                                     Side and mast
                                                                     navigational lights with
                                                                     improper glasses. Main
                                                                     magnetic compass
                                                                     inoperative. Gyro
                                                                     compass repeaters
                                                                     inoperative. Funnel
                                                                     corroded through. Funnel
                                                                     dampers inoperative. ER
                                                                     air vent covers
                                                                     obstructed with drums.
                                                                     On rescue boat engine
                                                                   safety pin missing. AB
                                                                   cabin window not water
                                                                   tight. Both aft hold air
                                                                   vents artificially holed.
                                                                   One guide head on hatch
                                                                   cover detached. STB
                                                                   chain pipe corroded
                                                                   through. Galley hood
                                                                   dirty. In galley several
                                                                   electrical cables not
                                                                   isolated. Diesel
                                                                   generator room dirty and
                                                                   slippery. DG1 & DG3
                                                                   without guards. Steering
                                                                   gear room floor slippery.
                                                                   Emergency compressor
                                                                   inoperative. Emergency
                                                                   fire pump inoperative.
                                                                   Ship has no bilge holding
                                                                   tank. Illegal discharge
                                                                   valve fitted on OFE
                                                                   outboard line. Oil filtering
                                                                   equipment inoperative.
                                                                   ME fuel leaking alarm
                                                                   inoperative. On ME
                                                                   cooling water leaking.
                                                                   QCV inoperative.
                                                                   Sanitary facilities in poor
                                                                   condition. Maintenance
                                                                   of ship and equipment
                                                                   failed. Emergency
                                                                   preparedness failed.
21/01/2008   NAXOS           Panama   Alkionis       Hellenic      Detained for 5 days.
             EXPRESS                  Shipping Co.   Register of   23 recorded deficiencies.
Koper                                                Shipping      In wheelhouse clear
             General cargo            Drapetsona                   screen view window
                                                                   missing. Funnel corroded
             7432836                  Greece                       through. Wheelhouse
                                                                   bulkhead corroded
             1.633                                                 through. STB side
                                                                   navigational light glass
                                                                   cracked. Monkey bridge
                                                                   deck temporary repaired
                                                                   with tape. Air condition
                                                                   cables improperly pass
                                                                   through the bulkhead.
                                                                   Chief engineer cabin
                                                                   bulkhead corroded
                                                                   through. Front bridge
                                                                   bulkhead corroded
                                                                   through. In hold PS two
                                                                   frame corners detached.
                                                                   In hold several frames
                                                                   bent. In hold 2 tripping
                                                                   plates corroded through.
                                                                   PS chain pipe corroded
                                                                   through. Emergency fire
                                                                   pump insufficient
                                                                   pressure. In paint room
                                                                   air vent missing. Hatch
                                                                    covers corroded through.
                                                                    In ER grey water pipes
                                                                    temporary repaired. ME
                                                                    fuel leaking alarm
                                                                    inoperative. Sludge
                                                                    pump lines connected to
                                                                    the OFE. Bilge and
                                                                    sludge pump suction
                                                                    pipes made of rubber.
                                                                    DG No 2 water cooler
                                                                    leaking. Fuel tank
                                                                    gauges improper. Ship
                                                                    has no holding tank.
                                                                    Maintenance of ship and
                                                                    equipment failed.
22/01/2008   GLORIA II       St.       Errada        Bureau Veritas Detained for 3 days.
                             Vincent & Shipping                     Radio room window
Koper        Bulk carrier    Grenadine                              glass cracked. Galley
                                       Vlore                        scuttle glass cracked.
             7725532                                                Mess room scuttle glass
                                       Albania                      cracked. Deck between
             3.127                                                  hold 2 and bridge
                                                                    corroded through. Deck
                                                                    between hold 2 and
                                                                    bridge buckled. On DG
                                                                    fuel tank QCV
                                                                    disconnected.
                                                                    Emergency diesel
                                                                    generator can not start
                                                                    manually. FP air pipe ball
                                                                    protection corroded
                                                                    through. Steering gear
                                                                    room emergency exit
                                                                    obstructed with drums.
                                                                    Grey water pipes made
                                                                    of rubber. Diesel
                                                                    generator fuel leaking.
                                                                    ME fuel leaking alarm
                                                                    inoperative. OFE
                                                                    inoperative. Valve box
                                                                    can be illegally
                                                                    connected with rubber
                                                                    pipe. Bilge pump
                                                                    connected with rubber
                                                                    pipe to unknown
                                                                    discharge. Lifeboat
                                                                    engine insufficient
                                                                    power. Abandon ship drill
                                                                    failed. Maintenance of
                                                                    ship and equipment
                                                                    failed.
01/02/2008   DONBATE         Comoros   South river   International  Detained for 16 days.
                                       shipping      Naval Survey 25 recorded deficiencies.
Koper        General cargo                           Bureau         Wheelhouse bulkhead
                                       Kherson                      corroded through. Funnel
             7806037                                                corroded through. Two
                                       Ukraine                      red lights for ship not
             2.453                                                  under command with
                                                                    improper glasses. Bridge
                                                                    toilet bulkhead corroded
                                                                     through. ER door
                                                                     corroded through. Stern
                                                                     navigational light glass
                                                                     cracked. Both ER air
                                                                     vents corroded through.
                                                                     Alleyway bulkhead
                                                                     corroded through. Cabin
                                                                     bulkhead corroded
                                                                     through. Galley window
                                                                     frame corroded through.
                                                                     FW air pipe corroded
                                                                     through. Ballast tank 23
                                                                     air pipe corroded
                                                                     through. Paint room air
                                                                     vent missing. STB chain
                                                                     pipe corroded through. In
                                                                     hold 1 STB platform
                                                                     corroded through. In hold
                                                                     1 PS 3 beams corroded
                                                                     through. In hold 1 STB 2
                                                                     beams corroded through.
                                                                     In hold 2 hatch covers
                                                                     frames corroded through.
                                                                     In hold 2 aft 1 beam
                                                                     corroded through. In hold
                                                                     2 entrance 1 frame
                                                                     corroded through. In hold
                                                                     2 AFT STB hatch
                                                                     coaming corner plate
                                                                     damaged. Sludge tank,
                                                                     bilge tank and pumps
                                                                     connected with rubber
                                                                     pipes. On OFE three way
                                                                     valve missing. Food
                                                                     quantity insufficient. ISM
                                                                     _ MNC maintenance of
                                                                     ship and equipment
                                                                     failed.
05/02/2008   RANIM B         Cambodia Rasha          International   Detained for XX days.
                                      Shipping Co.   Naval Survey    31 recorded deficiencies.
Koper        General cargo                           Bureau          All navigational lights
                                       Tartous                       with improper glasses.
             7519787                                                 Wheelhouse bulkhead
                                       Syria                         corroded through. Air
             3.501                                                   condition room bulkhead
                                                                     corroded through. Air
                                                                     condition room door
                                                                     corroded through. On
                                                                     EDG fuel tank QCV
                                                                     missing. EDG connected
                                                                     with rubber pipes to fuel
                                                                     tank. On former hospital
                                                                     door glass cracked.
                                                                     Empty cabin window
                                                                     glass cracked. Cabin
                                                                     bulkhead corroded
                                                                     through. Front bridge
                                                                     bulkhead corroded
                                                                     through. Hold 3 entrance
                                                                     cover corroded through.
                                                                 Hold 3 AFT air vent
                                                                 corroded through. In hold
                                                                 3 aft 8 consecutive
                                                                 beams and corner plates
                                                                 bent. In hold 3 PS 2
                                                                 consecutive frames bent.
                                                                 In hold 3 aft bulkhead
                                                                 buckled. On hold 3 hatch
                                                                 covers wire leader on
                                                                 mast house detached.
                                                                 Hatch covers on hold 3
                                                                 corroded through. Hatch
                                                                 covers on hold 2
                                                                 corroded through. Hatch
                                                                 covers on hold 1
                                                                 corroded through. In FP
                                                                 aft 2 frames corroded
                                                                 through. FP platform
                                                                 corroded through. Paint
                                                                 room air vent missing. Tk
                                                                 20 air pipe corroded
                                                                 through. Main and
                                                                 auxiliary boilers
                                                                 inoperative. OFE outlet
                                                                 line improperly installed
                                                                 on hull. Possible illegal
                                                                 discharge valve fitted on
                                                                 hull. On all fuel tanks
                                                                 sounding gauges made
                                                                 of rubber. Sanitary
                                                                 facilities dirty. EFP door
                                                                 corroded through. ISM -
                                                                 NC maintenance of ship
                                                                 and equipment failed.
06/02/2008   DANIEL STAR     Syria   ISM group   International   Detained for 8 days.
                                                 Register of     21 recorded deficiencies.
Koper        General cargo           Tarous      Shipping        Hull corroded through.
                                                                 Chart No 1471 missing.
             6726199                 Syria                       GMDSS batteries
                                                                 oxidised. Magnetic
             1.996                                               compass blocked in
                                                                 gimble. Funnel corroded
                                                                 through. ER air vent
                                                                 corroded through. Base
                                                                 plates on cargo winches
                                                                 on hold 2 corroded
                                                                 through. PS standard
                                                                 discharge connection
                                                                 improper. On hold 2
                                                                 hatch covers cracked
                                                                 and frames corroded
                                                                 through. In hold 2 corner
                                                                 plate damaged. On
                                                                 windlass 1 frame
                                                                 corroded through. On
                                                                 FCSL on 1 fire hydrant
                                                                 hand wheel missing.
                                                                 Main fire line temporary
                                                                 repaired. Top of the FP
                                                                 tank corroded through. In
                                                                        FP several frames
                                                                        corroded through.
                                                                        Platform in FP corroded
                                                                        through. On hold 1
                                                                        hatchcoaming frame
                                                                        corroded through. PS
                                                                        lifeboat davit corroded
                                                                        through. PS lifeboat davit
                                                                        upper pulley bent.
                                                                        Abandon ship drill failed.
                                                                        ISM - MNC maintenance
                                                                        of ship and equipment
                                                                        failed.
12/02/2008   MAYA            Mongolia   Mody           International    Detained for 14 days.
                                        Shipping Co.   Ship             27 recorded deficiencies.
Koper        General cargo                             Classification   STB gangway platform
                                        Beirut                          damaged. Under
             7017430                                                    gangway safety net
                                        Lebanon                         missing. No security
             2.352                                                      records and checks on
                                                                        access. Two ball for ship
                                                                        not under command to
                                                                        small. Funnel corroded
                                                                        through. Main magnetic
                                                                        compass sized in gimble.
                                                                        All air condition cables
                                                                        improperly installed
                                                                        through the bulkheads.
                                                                        Fore and aft anchor
                                                                        lights with improper
                                                                        glasses. Front bridge
                                                                        bulkhead corroded
                                                                        through. In hold 2 aft
                                                                        bulkhead frames
                                                                        corroded through. In hold
                                                                        2 several frames
                                                                        corroded through. In hold
                                                                        2 several frames and
                                                                        frame corners bent,
                                                                        damaged and cracked.
                                                                        One frame detached
                                                                        from hull. In hold 2 fore
                                                                        and aft longitudinal
                                                                        support corroded
                                                                        through. In hold 2 top of
                                                                        the tank No. 7 corroded
                                                                        through. In hold 1 fore
                                                                        peak bulkhead corroded
                                                                        through. In DG room
                                                                        bulkhead corroded
                                                                        through. On hold 1 hatch
                                                                        covers frames corroded
                                                                        through. On hold 2 hatch
                                                                        coaming frame cracked.
                                                                        EFP inoperative.
                                                                        Possible illegal discharge
                                                                        fitted. ME fuel leaking
                                                                        alarm inoperative. PS
                                                                        lifeboat can not be
                                                                        lowered into the sea.
                                                                      Abandon drill failed. ISM-
                                                                      MNC maintenance of
                                                                      ship and equipment
                                                                      failed. Emergency
                                                                      preparedness failed.
14/02/2008   ORIENTAL SUN Comoros       Mansour        Russian        Detained for 3 days.
                                        Shipping Co.   Maritime       18 recorded deficiencies.
Koper        General cargo                             Register of    Binnacle of PS gyro
                                        Tartous        Shipping       repetitor completely
             7729174                                                  detached from deck. All
                                        Syria                         air condition cables
             8.583                                                    improperly installed
                                                                      through the bulkheads.
                                                                      Two red lights for ship
                                                                      not under command with
                                                                      improper glasses. STB
                                                                      side light and stern
                                                                      navigational light with
                                                                      improper glasses. Both
                                                                      ER air vent dampers
                                                                      sized. Electric room
                                                                      bulkhead corroded
                                                                      through. On hospital
                                                                      door glass cracked. Aft
                                                                      hold 3 hatchway
                                                                      entrance corroded
                                                                      through. Tank No 3 STB
                                                                      air pipe corroded
                                                                      through. Hold 1 air vent
                                                                      duct corroded through.
                                                                      On DG1 and DG2 fuel
                                                                      leaking. On DG1, DG2
                                                                      and DG3 jacketed high
                                                                      pressure lines
                                                                      disconnected. Fuel
                                                                      leaking alarms on DG1
                                                                      and DG2 improperly
                                                                      installed. On fuel tanks
                                                                      QCVs inoperative. On
                                                                      ME jacketed high
                                                                      pressure lines
                                                                      disconnected. OFE
                                                                      inoperative. Saloon
                                                                      bulkhead corroded
                                                                      through. OFE and
                                                                      content meter certificates
                                                                      missing.
19/02/2008   ARROW S         Mongolia   Global       International    Detained for 3 days.
                                        Management Ship               22 recorded deficiencies.
Koper        General cargo              & Trading Co Classification   No original SMC
                                                                      certificate on board. No
             7392608                    Tripoli                       original ISSC on board.
                                                                      Chart No 1471 missing.
             2.765                      Lebanon                       Navigational lights alarm
                                                                      inoperative. Two red
                                                                      lights for ship not under
                                                                      command with improper
                                                                      glasses. Stern anchor
                                                                      light with improper glass.
                                                                      Alleyway door threshold
                                                                   on upper deck corroded
                                                                   through. Alleyway door
                                                                   threshold on boat deck
                                                                   corroded through. PS ER
                                                                   air vent corroded
                                                                   through. Oiler's cabin
                                                                   bulkhead corroded
                                                                   through. Alleyway door
                                                                   on boat deck glass
                                                                   cracked. In hold STB 1
                                                                   frame damaged. Top of
                                                                   the tank No. 3 cracked.
                                                                   Top of the tank No 4
                                                                   holed in three places. In
                                                                   hold STB tank 3 air pipe
                                                                   corroded through. Tank
                                                                   No 4 PS fore and aft air
                                                                   pipes corroded through.
                                                                   Tank No 3 PS fore and
                                                                   aft air pipes corroded
                                                                   through. Tank No 2 PS
                                                                   aft air pipe corroded
                                                                   through. Tank No 3 STB
                                                                   fore air pipe corroded
                                                                   through. STB standard
                                                                   discharge connection
                                                                   flange improper. Valve
                                                                   box illegally connected
                                                                   with 2 rubber pipes,
                                                                   which permit an illegal
                                                                   discharge of ER bilge in
                                                                   the sea. ISM-MNC
                                                                   maintenance of ship and
                                                                   equipment failed.
03/03/2008   MINA            Cambodia Global       Turkish Lloyd   Detained for 6 days.
                                      Management                   18 recorded deficiencies.
Koper        General cargo            & Trading                    STB side navigational
                                                                   light glass cracked.
             7214818                  Tripoli                      Wheelhouse bulkhead
                                                                   corroded through.
             1.923                    Lebanon                      Captain cabin bulkhead
                                                                   corroded through. Funnel
                                                                   corroded through. Front
                                                                   bridge bulkhead
                                                                   corroded through.
                                                                   Standard discharge
                                                                   connection improper.
                                                                   Sanitary facilities not
                                                                   hygienic. Galley hood
                                                                   dirty. PS hull corrosion
                                                                   wastage. DG2 bilge dirty.
                                                                   Grey water pipes in ER
                                                                   made of rubber. All fuel
                                                                   tanks QCV inoperative.
                                                                   ME fuel leaking alarm
                                                                   inoperative. STB lifeboat
                                                                   main rail damaged. Ship
                                                                   has no lifeboat with
                                                                   engine. Ship has no fast
                                                                   rescue boat. Rubber pipe
                                                                  connection between
                                                                  sludge and bilge tanks.
                                                                  MNC-emergency
                                                                  preparedness failed.
11/03/2008   YORDANKA       Bulgaria   Navigation   Bulgarian     Detained for 3 days.
             NIKOLOVA                  Maritime     Registry of   32 recorded deficiencies.
Koper                                  Bulgare      Shipping      All ship's statutory
             Bulk carrier                                         certificates expired. On
                                       Varna                      PS hull corroded
             7813028                                              through. Gyro compass
                                       Bulgaria                   inoperative. All
             23.363                                               navigational lights with
                                                                  improper glasses.
                                                                  Wheelhouse bulkhead
                                                                  corroded through.
                                                                  Navigational lights alarm
                                                                  inoperative. Alleyways
                                                                  bulkhead corroded
                                                                  through. Funnel corroded
                                                                  through. Battery room
                                                                  bulkhead corroded
                                                                  through. Hospital
                                                                  bulkhead corroded
                                                                  through. Aft capstan bed
                                                                  plate corroded through.
                                                                  ER air vent damper
                                                                  sized. Bulkhead between
                                                                  ER and ER air vent place
                                                                  corroded through. EDG
                                                                  room bulkhead corroded
                                                                  through. CQV on EDG
                                                                  fuel tank inoperative.
                                                                  Lifeboat inventory
                                                                  stowed in store room. In
                                                                  STB lifeboat 2 oars and
                                                                  engine exhaust pipe
                                                                  damaged. STB lifeboat
                                                                  damaged. Alleyway
                                                                  bulkhead corroded
                                                                  through. In store upper
                                                                  deck corroded through.
                                                                  Chief steward cabin
                                                                  bulkhead corroded
                                                                  through. In PS wing tank
                                                                  No 10 one longitudinal
                                                                  frame corroded through.
                                                                  Windlass bed plate and
                                                                  brake plate corroded
                                                                  through. DG bilge dirty.
                                                                  ME fuel leaking alarm
                                                                  inoperative. Steam
                                                                  collector leaking. Air
                                                                  condition outboard
                                                                  condense pipe made of
                                                                  rubber. On steering gear
                                                                  hydraulic oil leaking.
                                                                  Abandon drill failed.
                                                                  MNC-maintenance of
                                                                  ship and equipment
                                                                  failed.
19/03/2008   SOL TRADER      St Vincent Anamila d.o.o Bureau Veritas Detained for 5 days.
                             & Grenad.                               26 recorded deficiencies.
Koper        General cargo              Rijeka                       No safety net posted
                                                                     under the gangway. Only
             7504184                    Croatia                      one certified engineer on
                                                                     board. OFE certificates
             1.583                                                   missing. Main magnetic
                                                                     compass inoperative.
                                                                     Galley door corroded
                                                                     through. Galley bulkhead
                                                                     corroded through.
                                                                     Standard discharge
                                                                     connection improper. On
                                                                     paint room air vent
                                                                     missing. Self igniting
                                                                     lights on lifebuoys
                                                                     inoperative. Bulwark
                                                                     frames under roller
                                                                     fairlead corroded
                                                                     through. In steering gear
                                                                     room grey water pipes
                                                                     temporary repaired. Fuel
                                                                     tanks gauges blocked
                                                                     with wire or wooden
                                                                     wedges. In steering gear
                                                                     room hull heavy buckled.
                                                                     Delivery pipe on DG
                                                                     cooling water pump
                                                                     corroded through and
                                                                     leaking heavily. Possible
                                                                     illegal discharge pipe
                                                                     fitted. Bilge pump pipe
                                                                     temporary repaired. OFE
                                                                     inoperative. On OFE
                                                                     outboard line two
                                                                     additional pipes fitted.
                                                                     On DG cooling water
                                                                     lines outboard valves not
                                                                     as required. On ME FLA
                                                                     missing. Communication
                                                                     between steering gear
                                                                     room and bridge not as
                                                                     required. Deck between
                                                                     bridge and hold buckled.
                                                                     Lifeboat engine
                                                                     inoperative. Abandon
                                                                     ship drill failed. MNC -
                                                                     Maintenance of ship and
                                                                     equipment failed.
01/04/2008   LOTUS           Comoros Vento            International  Detained for 10 days.
                                        Denizcilik    Naval Survey 24 recorded deficiencies.
Koper        General cargo                            Bureau         Charts for the planed
                                        Istanbul                     voyage not up to date.
             7203326                                                 Wheelhouse bulkhead
                                        Turkey                       corroded through. Funnel
             1.583                                                   corroded through. Main
                                                                     magnetic compass with
                                                                     big bubble. Steering
                                                                     magnetic compass 10°
                                                                     with gyro compass.
                                                              Monkey bridge deck
                                                              corroded through. Chief
                                                              engineer cabin bulkhead
                                                              corroded through. Deck
                                                              over ER corroded
                                                              through. Front bridge
                                                              corroded through in
                                                              several places. Steering
                                                              gear air vent corroded
                                                              through. Chief engineer
                                                              cabin air vent corroded
                                                              through. Chief mate
                                                              cabin bulkhead corroded
                                                              through. Seven spare
                                                              cabins air vents corroded
                                                              through. In hold 2 wing
                                                              tank bulkhead cracked
                                                              and corroded through in
                                                              several places. In FCSL
                                                              4 consecutive frames
                                                              and frame corners bent.
                                                              In fore peak tank
                                                              collision bulkhead,
                                                              longitudinal plate, frames
                                                              and second platform
                                                              corroded through. On
                                                              both ME all jacketed
                                                              lines disconnected. Fuel
                                                              leaking alarm on both
                                                              ME inoperative. Possible
                                                              illegal discharge line
                                                              fitted on OFE outboard
                                                              line. Fuel tank connected
                                                              with rubber pipe to the
                                                              DO pump. Oil bilge line
                                                              connected to the DO
                                                              pump. On OFE 3 way
                                                              valve inoperative. MNC -
                                                              company responsibility
                                                              and authority failed.
                                                              MNC - maintenance of
                                                              ship and equipment
                                                              failed.
14/04/2008   MASTER JOY      Panama   GMZ          Lloyd's    Detained for 3 days.
                                      Shipping     register   17 recorded deficiencies.
Koper        General cargo            Management              Number of IOPP and
                                                              IOPP supplement not the
             7034828                  Beirut                  same. Possibility to mix
                                                              sludge with fuel.
             5.756                    Lebanon                 Wheelhouse bulkhead
                                                              corroded through. Locker
                                                              bulkhead corroded
                                                              through. Acetylene room
                                                              door corroded through.
                                                              Galley door inner gasket
                                                              holder corroded through.
                                                              On FCSL CO2 air vent
                                                              ball protection corroded
                                                              through. FSCL door
                                                              corroded through. On FP
                                                                     tank manhole additional
                                                                     pipe fitted. Ballast DB 1
                                                                     STB air pipe corroded
                                                                     through. On FCSL bell
                                                                     missing. Connection of
                                                                     hatch cover No5
                                                                     cracked. On both food
                                                                     compressors guards
                                                                     missing. ME FLA
                                                                     inoperative. OFE
                                                                     inoperative. Approved
                                                                     drawing of OFE piping
                                                                     missing. Pipes on
                                                                     membrane pump
                                                                     improperly connected.
17/04/2008   SOL TRADE       St Vincent Anamila d.o.o Bureau Veritas Detained for 2 days.
                             &                                       2 recorded deficiencies.
Koper        General cargo   Grenadine Rijeka                        Pneumatic valve on ME
                                                                     blocked. One steering
             7504184                    Croatia                      gear pump inoperative.

             1.583
17/04/2008   SORMOVSKIY      Russia     Volga - Neva  Russian          Detained for 9 days.
             3050                                     Maritime          22 recorded deficiencies
Koper                                   St Petersburg register of      Wipers inoperative.
             General cargo                            Shipping         Radio room skylight
                                        Russia                         glass cracked. Deck over
             8101434                                                   ME corroded through. Air
                                                                       condition room bulkhead
             3.041                                                     corroded through. Funnel
                                                                       dampers sized. Toilet
                                                                       bulkhead corroded
                                                                       through. Store bulkhead
                                                                       corroded through. Front
                                                                       bridge corroded through.
                                                                       Alleyway threshold on
                                                                       main deck corroded
                                                                       through. DB4 air pipe
                                                                       corroded through. Hatch
                                                                       coaming frame on hold 2
                                                                       corroded through. Hatch
                                                                       coaming frames on hold
                                                                       1 corroded through. Hold
                                                                       1 front bulkhead
                                                                       corroded through. FP
                                                                       manhole cover not
                                                                       bolted. Ball protection on
                                                                       FP air pipe corroded
                                                                       through. Bilge pump with
                                                                       rubber suction pipe.
                                                                       Crew does not use
                                                                       personal protective
                                                                       equipment. OFE
                                                                       inoperative. Wing tanks
                                                                       No 2 and 5 cracked. Part
                                                                       of main fire line
                                                                       corroded. ISM -
                                                                       maintenance of ship and
                                                                       equipment failed.
24/04/2008   SVETI           Malta      Trimpex Ltd    Russian         Detained for 9 days.
             SERAFIM              Varna       Maritime        30 recorded deficiencies.
Koper                                         Register of     In wheelhouse clear
                                   Bulgaria   Shipping        screen view window
                                                              missing. ER skylight
                                                              corroded through.
                                                              Hospital bulkhead
                                                              corroded through.
                                                              Magnetic compass with
                                                              air bubbles. Battery room
                                                              bulkhead corroded
                                                              through. In hold No 4
                                                              fore bulkhead corroded
                                                              through. In hold No 4 on
                                                              both sides several
                                                              frames corroded through.
                                                              In hold 3 two pipe
                                                              protection frames
                                                              cracked. In hold 3 fore
                                                              and aft bulkheads
                                                              corroded through.
                                                              Access ladder to hold 3
                                                              bent. Hold 3 hatch
                                                              coaming inner frames
                                                              detached. In hold 2 fore
                                                              and aft bulkheads
                                                              corroded through in
                                                              several places. In hold 2
                                                              four frame corners
                                                              damaged. In hold 1 aft
                                                              bulkhead corroded
                                                              through. In hold 1
                                                              several frames bent,
                                                              cracked and corroded
                                                              through on both sides. In
                                                              hold 1 upper and lower
                                                              longitudinal frames
                                                              corroded through. Top of
                                                              paint room door corroded
                                                              through. Front bridge
                                                              bulkhead corroded
                                                              through. Alleyway door
                                                              corroded through. Meat
                                                              room temperature - 5°C.
                                                              ER bilge dirty. Ejector for
                                                              bilge fitted without class
                                                              approval. PS lifeboat
                                                              repaired without class
                                                              approval. On both
                                                              lifeboats hook
                                                              protections corroded
                                                              through. PS lifeboat
                                                              engine inoperative. Crew
                                                              does not use personal
                                                              protective equipment.
                                                              Hose leaking in whole
                                                              lengths. Abandon drill
                                                              failed. ISM maintenance
                                                              of ship and equipment
                                                              failed.
05/05/2008   ANTARES 1   Cambodia Elreedy     International   Detained for 4 dajs.
                                        Shipping      Naval Survey    22 recorded deficiencies.
Koper        General cargo                            Bureau          Chart No 1471 not up to
                                        Damietta                      date. Radio room
             7508532                                                  bulkhead corroded
                                        Egypt                         through. Wheelhouse
             4.793                                                    bulkhead corroded
                                                                      through. Magnetic
                                                                      compass with air
                                                                      bubbles. Dampers on
                                                                      both ER air vents sized.
                                                                      Both ER air vents
                                                                      corroded through. Front
                                                                      bridge bulkhead
                                                                      corroded through. Frame
                                                                      on the support of aft
                                                                      derrick corroded through.
                                                                      PS aft cargo winch base
                                                                      corroded through. PS 2
                                                                      air pipes corroded
                                                                      through. FW air pipe on
                                                                      poop deck corroded
                                                                      through. On mast house
                                                                      derrick stay winch frame
                                                                      corroded through. On
                                                                      FCSL bell missing.
                                                                      Panama eye damaged.
                                                                      In FCSL hawser pipe
                                                                      cracked. FP manhole
                                                                      cover not bolted.
                                                                      Protection on hydrophore
                                                                      pump missing. In ER
                                                                      STB hull temporary
                                                                      repaired with concrete.
                                                                      FWD ER bulkhead
                                                                      temporary repaired with
                                                                      bolted plate. Rudder tiller
                                                                      in lifeboat to short.
                                                                      Lifeboat speed
                                                                      insufficient. ISM - MNC
                                                                      maintenance of ship and
                                                                      equipment failed.
12/05/2008   GLORIUS         Cyprus     Frangolious   Nippon Kaiji    Detained for 5 days.
                                        Ship          Kyokai          7 recorded deficiencies.
Koper        General cargo              management                    FW air pipe ball
                                                                      protection corroded
             7915230                    Piraeus                       through. Oil air pipe
                                                                      corroded through. Cargo
             14.141                     Greece                        Winches bases corroded
                                                                      through. Hatch covers on
                                                                      hold 1 corroded through.
                                                                      Hatch covers on hold 2
                                                                      corroded through. hatch
                                                                      covers on hold 4
                                                                      corroded through.
15/05/2008   VAN DYCK        St Vincent Convoy        Registro        Detained for 2 days.
                             &          Maritime      Italiano Navale 8 recorded deficiencies.
Koper        General cargo   Grenadine                                Air condition installation
                                        Izmir                         not as required. Hold No
             7374644                                                  5 both air vents corroded
                                        Turkey                        through. FO No3 air pipe
             16.166                                                     corroded through. FP air
                                                                        pipe corroded through.
                                                                        On FCSL bell missing.
                                                                        Bilge oil separator
                                                                        connected to ballast line.
                                                                        Filling pipes in AP tank
                                                                        inoperative. Emergency
                                                                        fire pump inoperative.
19/05/2008   FEDON           Barbados   Machrimar       Germanischer    Detained for 2 days.
                                        Management      LLoyd           15 recorded deficiencies.
Koper        Bulk carrier                                               On signal mast Inmarsat
                                        Piraeus                         platform corroded
             7942336                                                    through. Locker
                                        Greece                          bulkhead corroded
             22.465                                                     through. Funnel corroded
                                                                        through. Funnel dampers
                                                                        sized. ER sky light ER
                                                                        air vent bulkhead
                                                                        corroded through. Air
                                                                        condition room bulkhead
                                                                        corroded through. Safety
                                                                        locker bulkhead corroded
                                                                        through. On DG1 and
                                                                        DG3 jacketed high
                                                                        pressure lines
                                                                        disconnected. In ER AP
                                                                        bulkhead corroded
                                                                        through. Gusset plate
                                                                        behind air condition
                                                                        pump corroded through.
                                                                        Air vent line in steering
                                                                        gear room corroded
                                                                        through. One steering
                                                                        gear electromotor
                                                                        missing. PS lifeboat
                                                                        tackle corroded through.
                                                                        Abandon drill failed.
20/05/2008   EL HUSSAIN      Libya      North African   International   Detained for 6 days.
                                        Company         Naval Survey    21 recorded deficiencies.
Koper        General cargo                              Bureau          Monkey deck corroded
                                        Tripoly                         through. Funnel corroded
             7915199                                                    through. Safety store
                                        Libya                           bulkhead corroded
             7.533                                                      through. Alleyway
                                                                        threshold corroded
                                                                        through. ER fire dampers
                                                                        sized. Hospital bulkhead
                                                                        corroded through. PS
                                                                        lifeboat engine
                                                                        inoperative. Crew mess
                                                                        room bulkhead corroded
                                                                        through. Tally room
                                                                        bulkhead corroded
                                                                        through. Officer mess
                                                                        room bulkhead corroded
                                                                        through. Bulkhead on PS
                                                                        boat deck corroded
                                                                        through. FW tank gauges
                                                                        not as required. LO
                                                                        leaking on DG3. On DG4
                                                                        jacketed lines
                                                                        inoperative. ON DG 2 &
                                                                        DG3 jacketed high
                                                                        pressure lines
                                                                        disconnected. Cooling
                                                                        water leaking on ME
                                                                        cylinder No 3. Engine
                                                                        bilge full. Sludge and
                                                                        bilge waters tanks full.
                                                                        Connection between
                                                                        bilge tank and bilge
                                                                        pump inoperative.
                                                                        Sewage treatment plant
                                                                        inoperative. Sewage tank
                                                                        not approved by RO.
24/05/2008   SVETI           Slovakia      Trimpex       Russian        Detained for 4 days.
             NIKOLAY                       Union         Maritime       13 recorded deficiencies.
Koper                                                    Register of    Aft wheelhouse window
             General cargo                 Varna         Shipping       crashed. Funnel
                                                                        dumpers inoperative.
             7630311                       Bulgaria                     Stern navigational light
                                                                        with improper glass. Both
             3.269                                                      ER air vents corroded
                                                                        through. Hold No 4 two
                                                                        aft bulkhead frames
                                                                        damaged. In hold No 4
                                                                        one gusset plate
                                                                        corroded through. In hold
                                                                        3 FWD bulkhead
                                                                        cracked. in Hold No 2
                                                                        eleven frames corroded
                                                                        through. In hold No 2
                                                                        several frames bent. In
                                                                        hold No 1 several frames
                                                                        corroded through. In hold
                                                                        No 1 several frames and
                                                                        frame corners damaged.
                                                                        Steering gear room
                                                                        entrance bulkhead
                                                                        corroded through. MNC -
                                                                        maintenance of ship and
                                                                        equipment failed.
26/05/2008   NORTH STAR      St. Kitts &   Sigma grain   Bureau Veritas Detained for 4 days.
                             Nevis                                      23 recorded deficiencies.
Koper        Frigo                         Tartous                      Improper entries in ORB.
                                                                        RO improperly filled the
             7916454                       Syria                        IOPP certificate. OFE
                                                                        and bilge arrangement
             2.011                                                      plan missing. OFE and
                                                                        OFE contain meter
                                                                        certificates missing. Main
                                                                        magnetic compass glass
                                                                        cracked. Toilet air vent
                                                                        damper sized. ER door
                                                                        corroded through. ER
                                                                        door threshold corroded
                                                                        through. Upper galley air
                                                                        vent damper sized. On
                                                                        poop deck store
                                                                        hatchway cover corroded
                                                                        through. Standard
                                                                        discharge connection
                                                                        improper. Ball protection
                                                                        on oil air pipe corroded
                                                                        through. Hold No 1
                                                                        hatchway corroded
                                                                        through. Temperature on
                                                                        meat cold room -12° C.
                                                                        QCV on FO settling tank
                                                                        inoperative. On all three
                                                                        DGs jacketed high
                                                                        pressure lines
                                                                        disconnected. On DG
                                                                        No1 floating element
                                                                        missing FLA tank. On
                                                                        DG2 fuel leaking. On ME
                                                                        one jacketed line
                                                                        missing. Throttle valve
                                                                        on lifeboat engine not as
                                                                        required. Lifeboat speed
                                                                        insufficient.
30/05/2008   VOLGO BALT      St. Kitts &   Albross        Russian       Detained for 7 days.
             219             Nevis         Shipping       Maritime      15 recorded deficiencies.
Koper                                                     Register of   Hull corroded through.
             General cargo                 Istanbul       Shipping      DG room bulkhead
                                                                        corroded through. ER
             8841357                       Turkey                       bulkhead corroded
                                                                        through. DG room air
             2.457                                                      vent frame corroded
                                                                        through. Standard
                                                                        discharge connection
                                                                        flange connected to the
                                                                        main fire line. Cadet
                                                                        cabine bulkhead
                                                                        corroded through. FWD
                                                                        bulkhead in hold 2
                                                                        corroded through in
                                                                        several places. In hold 2
                                                                        STB wing tank corroded
                                                                        through. Both ER air vent
                                                                        corroded through. On
                                                                        poop deck eye damaged.
                                                                        In ER part of main fire
                                                                        line missing. Sludge line
                                                                        and clean lub oil line
                                                                        connected to same line.
                                                                        Crew does not use
                                                                        personal protective
                                                                        equipment. MNC-
                                                                        maintenance of ship and
                                                                        equipment failed.
03/06/2008   GRONX           Dominica      Leon Trading   Russian       Detained for 9 days.
                                                          Maritime      13 recorded deficiencies.
Koper        Bulk carrier                  Donetsk        Register of   Railings corroded
                                                          Shipping      through. DBT air pipe
             7646592                       Ukraine                      corroded through. Illegal
                                                                        discharge pipe installed.
             9.965                                                      Fire sensors inoperative.
                                                                        Cleanliness of store
                                                                        room insufficient. In cold
                                                                   room alarm missing. In
                                                                   galley filter missing.
                                                                   Chart not up to date.
                                                                   Crew not able to lower
                                                                   the lifeboat. Crew not
                                                                   able to operate the VHF
                                                                   DSC equipment.
                                                                   Maintenance of ship and
                                                                   equipment failed.
                                                                   Information MEI
                                                                   inspection missing.
17/06/2008   RABUNION 20     Syria     Rabunion    Hellenic        Detained for 2 days.
                                       Maritime    Register of     23 recorded deficiencies.
Koper        Livestock                 Agency      Shipping        Ship's access not
                                                                   watched. Funnel
             6817003                   Beirut                      corroded through. Toilet
                                                                   air vent corroded
             1.443                     Lebanon                     through. ER door
                                                                   corroded through. Air
                                                                   condition room bulkhead
                                                                   corroded through. Paint
                                                                   room bulkhead corroded
                                                                   through. Air condition
                                                                   cables improperly
                                                                   installed through the
                                                                   bulkheads. Weak link
                                                                   improperly fitted. Galley
                                                                   air vent damper sized.
                                                                   Hold air vent corroded
                                                                   through. Front bridge
                                                                   bulkhead corroded
                                                                   through. PS bulwark
                                                                   corroded through. On
                                                                   FCSL hatchway and
                                                                   hatchway cover corroded
                                                                   through. Rope store
                                                                   cover corroded through.
                                                                   Shelter deck corroded
                                                                   through. All holds air
                                                                   dampers sized. Four DO
                                                                   air pipes corroded
                                                                   through. TD STB 6
                                                                   frames corroded through.
                                                                   Hold aft longitudinal plate
                                                                   corroded through. Grey
                                                                   water line in steering
                                                                   gear room corroded
                                                                   through. 3 high pressure
                                                                   jacketed lines
                                                                   disconnected. DG room
                                                                   door corroded through.
                                                                   Maintenance of ship and
                                                                   equipment failed.
23/06/2008   YASAR           Georgia   Boss' 97    International   Detained for 5 days.
             CAPTAN                                Register of     21 recorded deficiencies.
Koper                                  Constanta   Shipping        PS hull temporary
             General cargo                                         repaired with doubler. PS
                                       Romania                     eye plate corroded
             7418440                                               through. Chart 1471
                                                                   missing. Bridge deck
3.493   corroded through. In hold
        3 four frames corroded
        through. In hold 3 seven
        frame corners corroded
        through. On ladder for
        entering in hold 3 steps
        missing. On hold 3 hatch
        coaming holed in several
        places. Bulkhead
        between hold 2& 3
        temporary repaired with
        doubler. In hold 2 five
        frame corners damaged.
        In hold 2 deck under
        mast house corroded
        through. Mast house
        door corroded through.
        Mast house bulkhead
        corroded through.
        Bulkhead between hold
        1&2 corroded through in
        several places. In hold 1
        top of the tank corroded
        through. In hold 1 top of
        the tank heavily buckled.
        On FCSL 4 bulwark
        frames under fairleads
        corroded through. FCSL
        deck corroded through in
        several places. FP air
        pipe corroded through.
        Under poop deck 7
        consecutive beams bent.
        Maintenance of ship and
        equipment failed.

				
DOCUMENT INFO