									                       REVERSE CYCLE SPLIT SYSTEM AIR CONDITIONERS SYSTEM SPECIFICATIONS
 MODEL #                                                           FTXG25EVMAW                FTXG35EVMAS                FTXS25EVMA                   FTXS35EVMA
 RATED CAPACITY                             COOL (KW)                      2.5                        3.5                       2.5                          3.5
                                            HEAT (KW)                      3.4                        4.2                       3.4                           4
 CAPACITY RANGE                             COOL (KW)                   1.3 - 3.0                  1.4 - 3.8                 1.2 - 3.0                    1.2 - 3.8
                                            HEAT (KW)                   1.3 - 4.5                  1.4 - 5.0                 1.2 - 4.5                    1.2 - 5.0
 ENERGY LABEL/STAR                            COOL                          6                          5                         6                           5.5
 RATING                                       HEAT                          6                         5.5                        6                           5.5
 POWER INPUT                                COOL (KW)              0.30 - 0.62 - 0.95         0.30 - 1.06 - 1.29        0.30 - 0.60 - 0.80           0.30 - 1.02 - 1.20
 (MIN-RATED-MAX)                            HEAT (KW)              0.29 - 0.82 - 1.42         0.31 - 1.13 - 1.56        0.29 - 0.83 - 1.34           0.29 - 1.08 - 1.55
 C.O.P.                                        C/H                     4.03 / 4.15                3.3 / 3.72                4.17 / 4.10                  3.43 / 3.70
 DIMENSIONS (HxWxD)                       INDOOR (mm)              275 x 840 x 150            275 x 840 x 150           283 x 800 x 195              200 x 1100 x 620
                                         OUTDOOR (mm)              550 x 765 x 285            550 x 765 x 285           550 x 765 x 285              550 x 765 x 285
 OPERATING RANGE                           COOL (˚CDB)                10 TO 46ºC                 10 TO 46ºC                10 TO 46ºC                   10 TO 46ºC
 (OUTDOOR TEMP)                            HEAT (˚CWB)               ‘-15 TO 20ºC               ‘-15 TO 20ºC              ‘-10 TO 20ºC                 ‘-10 TO 20ºC
( Due to ongoing product development, specifications are subject to change without notice. ) Other models available including cooling only systems
                           REVERSE CYCLE SPLIT SYSTEM AIR CONDITIONERS SYSTEM SPECIFICATIONS
 MODEL #                                                     FTXS50FVMA              FTXS60FVMA              FTXS71FVMA              FTXS80FVMA           FTXS90FVMA
 RATED CAPACITY                       COOL (KW)                      5                       6                      7.1                      8                    9
                                      HEAT (KW)                     5.8                      7                      8.2                     9.5                  9.7
 CAPACITY RANGE                       COOL (KW)                  1.7 - 6.0               1.7 - 6.7               2.3 - 8.5               2.3 - 9.0            2.3 - 9.7
                                      HEAT (KW)                  1.7 - 7.7               1.7 - 8.0              2.3 - 10.0              2.3 - 10.2            2.3 - 11.0
 ENERGY LABEL/STAR                      COOL                         5                       4                       4                      3.5                   3
 RATING                                 HEAT                         5                      4.5                      4                       3                    2
 POWER INPUT                          COOL (KW)            0.44 - 1.55 - 2.08      0.44 - 1.98 - 2.39      0.57 - 2.36 - 3.20      0.57 - 2.86 - 3.50   0.57 - 3.30 - 3.97
 (MIN-RATED-MAX)                      HEAT (KW)            0.40 - 1.60 - 2.53      0.40 - 2.04 - 2.81      0.52 - 2.52 - 3.75      0.52 - 3.28 - 3.82   0.52 - 3.54 - 4.18
 C.O.P.                                  C/H                    3.23 / 3.63             3.03 / 3.43             3.01 / 3.25             2.80 / 2.90          2.73 / 2.74
 DIMENSIONS (HxWxD)                 INDOOR (mm)            290 x 1050 x 238        290 x 1050 x 238        290 x 1050 x 238        290 x 1050 x 238     290 x 1050 x 238
                                   OUTDOOR (mm)             735 x 825 x 300         735 x 825 x 300         770 x 900 x 320         770 x 900 x 320      770 x 900 x 320
 OPERATING RANGE                     COOL (˚CDB)               10 TO 46ºC              10 TO 46ºC              10 TO 46ºC              10 TO 46ºC           10 TO 46ºC
 (OUTDOOR TEMP)                      HEAT (˚CWB)              ‘-15 TO 18ºC            ‘-15 TO 18ºC            ‘-15 TO 18ºC            ‘-15 TO 18ºC         ‘-15 TO 18ºC