Safetran DUAL-FREQUENCY GRADE CROSSING PREDICTORS

Document Sample
Safetran DUAL-FREQUENCY GRADE CROSSING PREDICTORS Powered By Docstoc
					                                                                                                                 B-1-1
Safetran
                       DUAL-FREQUENCY
                       GRADE CROSSING
                         PREDICTORS
                      MODELS 3000, 3000D2 AND 3000D2L
                                                             MICROPROCESSOR
                                                             CONTROLLED
                                                             KEYBOARD PROGRAMMING
                                                             COMPATIBLE WITH
                                                             SAFETRAN’S EVENT
                                                             ANALYZER/RECORDER (SEA/R)
                                                             ONE AND TWO TRACK
                                                             OPERATION
                                                             DUAL-FREQUENCY OPERATION
                                                             REDUNDANT, AUTOMATIC
                                                             TRANSFER SYSTEMS
                                                             (3000D2 AND 3000D2L)

  The Model 3000, 3000D2 and 3000D2L Dual-Frequency Grade Crossing Predictors (GCP) are microproces-
  sor-controlled systems that provide constant warning times at grade crossings for approaching trains,
  regardless of train speed. All operational features, including warning time, are user programmable via
  keypad and display at installation.
   The dual-frequency 3000 GCP is available as a single-track system for controlling a single track circuit or
  as a double system for controlling two track circuits. The 80214 Processor Module provides independent
  frequency operation on track 1 (T1) and Track 2 (T2) when used in the dual-frequency cases.
  The basic 3000 GCP includes a single transceiver and an island module. A second identical transceiver
  and island module enable a unit to operate with two unidirectional or four bidirectional approaches (two-
  track system).
  With the addition of one or two DAX prediction modules, up to four independent auxiliary prediction times
  can be provided. Optional data recorder interface modules permit the Safetran Event Analyzer/Recorder
  (SEA/R) to be used with any 3000 GCP.
  A keypad and alphanumeric liquid crystal display located on a removable keyboard serve as the communi-
  cations interface between the user and the system. The user can easily program and set up the unit,
  perform diagnostics and observe train move data. Automatic self-check circuits continually test the
  system at specific intervals, ensuring safe operation.
  Two redundant systems (Models 3000D2 and 3000D2L) are available and consist of two identical module
  sets plus an automatic transfer module. One module set serves as the primary system while the other
  serves as the backup. In the event of a failure of one system, control is automatically switched to the
  other. The module sets are housed in dual-bay cases. The Model 3000D2 is a vertically stacked case
  that is designed for standard 23-inch rack mounting. The Model 3000D2L is a side-by-side horizontal
  case designed for shelf mounting.                                                                            Grade
                                                                                                              Crossing
  7-98                                                                                                         Control
B-1-2

                                      SPECIFICATIONS
                                   MODEL 3000/3000D2 GCP
    Power Input:                                            Weight (All Modules in Place):
       Voltage – 9 to 16.5 VDC, 12 VDC nominal               Model 3000 GCP – 32 pounds (14.5 kilograms)
       Current – Single-track system - 1.25 amperes                 (approximate)
       Two-track system – 2.0 amperes                        Model 3000D2 GCP – 43 pounds (19.5 kilograms)
       Optional modules up to 0.5 ampere each additional            (approximate)
       Maximum Current – 4.0 amperes                         Model 3000D2L GCP – 43 pounds (19.5 kilo-
                                                                    grams) (approximate)
    Transceiver Output Current:
                                                            Temperature Range:
        Two settings – Medium, High
                                                               -40 degrees F + 160 degrees F
        Up to 500 mA (maximum), varies with frequency
                                                              (-40 degrees C to +71 degrees C)
    Frequency Range:
        Programmable from 45 to 999 Hz in 1 Hz increments

    Frequency Stability:
        + 0.01 percent

    Island Frequencies: (Programmable)
        2.14, 2.63, 3.24, 4.0, 4.9, 5.9, 7.1,
        8.3, 10.0, 11.5,13.2, 15.2, 17.5, or 20.2 kHz

    Island Circuit Length:
        Determined by island track wire connections (120-
            350 feet)

    Dimensions:
       Model 3000 Case
           14.36 inches (36.47 centimeters) high
           23 inches (58.42 centimeters) wide
           11.34 inches (28.80 centimeters) deep

        Model 3000D2
        (Automatic Transfer, vertically stacked) Case
            24 inches (60.96 centimeters) high
            23 inches (58.42 centimeters) wide
            11.34 inches (28.80 centimeters) deep

        Model 3000D2L
        (Automatic Transfer, side-by-side) Case
            14.36 inches (36.47 centimeters) high
            40.375 inches (102.55 centimeters) wide
            11.34 inches (28.80 centimeters) deep
                                                                                                      B-1-3

                    ORDERING INFORMATION
                                    MODEL 3000 GCP
                              To order, specify description and part number.

                                   Description                                       Part Number
                         ,
 Basic Model 3000 GCP Single-Track Operation
   Includes one (1) each of the following:
   Case, 80201, Intelligent Processor Island Module, 80211,                       80200-001
   Transceiver Module, 80012, Relay Drive Module, 80013,
   Processor Module, 80214, Control Interface Module, 80020-1
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-003
 with One (1) DAX Module, 80016
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-005
 with Two (2) DAX Modules, 80016
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-011*
 with Data Recorder Interface Module, 80255
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-013*
 with Data Recorder Interface Module, 80255, and One (1) DAX Module, 80016
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-015*
 with Data Recorder Interface Module, 80255, and Two (2) DAX Modules, 80016
                         ,
 Basic Model 3000 GCP Single-Track Operation with Keyboard                        80200-101
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-103
 with One DAX Module, 80016, plus Keyboard
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-105
 with Two (2) DAX Modules, 80016, plus Keyboard
                         ,
 Basic Model 3000 GCP Single-Track Operation
                                                                                  80200-111*
 with Data Recorder Interface Module, 80255, plus Keyboard
                         ,
 Basic Model 3000 GCP Single-Track Operation with Data Recorder
                                                                                  80200-113*
 Interface Module, 80255, and One (1) DAX Module, 80016, plus Keyboard
                         ,
 Basic Model 3000 GCP Single-Track Operation with Data Recorder
                                                                                  80200-115*
 Interface Module, 80255, and Two (2) DAX Modules, 80016, plus Keyboard
* Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250. (Please see catalog section B-
  13-1 for information on the SEA/R).

NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
B-1-4

                ORDERING INFORMATION (CONT.)
                                           MODEL 3000 GCP
                                     To order, specify description and part number.

                                             Description                                   Part Number
                               ,
        Basic Model 3000 GCP Two-Track Operation
         Includes the Following:
          Cases, 80201 (1), Intelligent Processor Island Module, 80211 (2)**              80200-002
          Transceiver Module, 80012 (2), Relay Drive Module, 80013 (1),
          Processor Module, 80214 (1), Control Interface Module, 80020-1 (1)
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-004
        with One (1) DAX Module, 80016
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-006
        with Two (2) DAX Modules, 80016
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-012*
        with Data Recorder Interface Module, 80255
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-014*
        with Data Recorder Interface Module, 80255, and One (1) DAX Module, 80016
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-016*
        with Data Recorder Interface Module, 80255 and (2) DAX Modules, 80016
                               ,
        Basic Model 3000 GCP Two-Track Operation with Keyboard                            80200-102
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-104
        with One DAX Module, 80016, plus Keyboard
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-106
        with Two (2) DAX Modules, 80016, plus Keyboard
                               ,
        Basic Model 3000 GCP Two-Track Operation
                                                                                          80200-112*
        with Data Recorder Interface Module, 80255, plus Keyboard
                               ,
        Basic Model 3000 GCP Two-Track Operation with Data
                                                                                          80200-114*
        Recorder Interface Module, 80255, and One (1) DAX Module, 80016, plus Keyboard
                               ,
        Basic Model 3000 GCP Two-Track Operation with Data
                                                                                          80200-116*
        Recorder Interface Module, 80255, and Two (2) DAX Modules, 80016, plus Keyboard
    * Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
      (Please see catalog section B-13-1 for information on the SEA/R).

    ** For unidirectional applications, only one island module is required.
       Specify unidirectional application when ordering.

    NOTE: For accessories and replacement parts, see page B-1-16 and B-1-17.
                                                                                                            B-1-5

                   ORDERING INFORMATION
                          MODEL 3000D2/3000D2L GCP
                               To order, specify description and part number.
                                                                                Part Number   Part Number
                                 Description
                                                                                  (3000D2)     (3000D2L)
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
  Includes the Following:
    Case, 80111/80141 (1), Intelligent Processor Island Module, 80211 (2)
                                                                                80110-001     80140-001
    Transceiver Module, 80012 (2), Relay Drive Module, 80013 (2),
    Processor Module, 80214 (2), Control Interface Module, 80020-1 (1),
    Control Interface Module, 80020-2 (1), Transfer Module, 80028 (1)
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
                                                                                80110-003     80140-003
with Two (2) DAX Modules, 80016
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
                                                                                80110-005     80140-005
with Four (4) DAX Modules, 80016
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
                                                                                80110-011*    80140-011*
with Two (2) Data Recorder Interface Modules, 80255
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One Track Operation
with Two (2) Data Recorder Interface Modules, 80255, plus Two (2)DAX            80110-013*    80140-013*
Modules, 80016
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
with Two (2) Data Recorder Interface Modules, 80255, and Four (4) DAX           80110-015*    80140-015*
Modules, 80016
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation with
                                                                                80110-101     80140-101
Keyboard
Basic Model 3000D2/D2L, Automatic Transfer, One-Track Operation
                                                                                80110-103     80140-103
with Two (2) DAX Modules, 80016, plus Keyboard
Basic Model 3000D2/D2L, Automatic Transfer, One-Track Operation
                                                                                80110-105     80140-105
with Four (4) DAX Modules, 80016, plus Keyboard
                          ,
Basic Model 3000D2 GCP Automatic Transfer, One-Track Operation
                                                                                80110-111*    80140-111*
with Two (2) Data Recorder Interface Modules, 80255, plus Keyboard
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
with Two (2) Data Recorder Interface Modules, 80255, and Two (2) DAX            80110-113*    80140-113*
Modules, 80016, plus keyboard
                               ,
Basic Model 3000D2/D2L GCP Automatic Transfer, One-Track Operation
with Two (2) Data Recorder Interface Modules, 80255, and Four (4) DAX           80110-115*    80140-115*
Modules, 80016, plus Keyboard
* Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250. (Please see catalog section B-
  13-1 for information on the SEA/R).
NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
B-1-6

                 ORDERING INFORMATION (CONT.)
                               MODEL 3000D2/3000D2L GCP
                                     To order, specify description and part number.
                                                                                         Part          Part
                                       Description                                      Number       Number
                                                                                       (3000D2)     (3000D2L)
        Basic Model 3000D2D2L GCP, Automatic Transfer, Two-Track Operation
         Includes the Following:
          Case, 80101/80141 (1) Intelligent Processor Island Module, 80211 (4)**
                                                                                      80110-002    80140-002
          Transceiver Module, 80012 (4), Relay Drive Module, 80013 (2),
          Processor Module, 80214 (2), Control Interface Module, 80020-1 (1),
          Control Interface Module, 80020-2 (1), Transfer Module, 80028 (1)
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-004    80140-004
        with Two (2) DAX Modules, 80016
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-006    80140-006
        with Four (4) DAX Modules, 80016
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-012*   80140-012*
        with Two (2) Data Recorder Interface Modules, 80255
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two Track Operation
        with Two (2) Data Recorder Interface Modules, 80255, and Two (2) DAX          80110-014*   80140-014*
        Modules, 80016
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
        with Two (2) Data Recorder Interface Modules, 80255, and Four (4) DAX         80110-016*   80140-016*
        Modules, 80016
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-102    80140-102
        with Keyboard
        Basic Model 3000D2/D2l GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-104    80140-104
        with Two DAX Modules, 80016, plus Keyboard
        Basic Model 3000D2/D2l, Automatic Transfer, Two-Track Operation
                                                                                      80110-106    80140-106
        with Four (4) DAX Modules, 80016, plus Keyboard
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
                                                                                      80110-112*   80140-112*
        with Two (2) Data Recorder Interface Modules, 80255, plus Keyboard
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
        with Two (2) Data Recorder Interface Modules, 80255, and Two (2) DAX          80110-114*   80140-114*
        Modules 80016, plus Keyborard
        Basic Model 3000D2/D2L GCP, Automatic Transfer, Two-Track Operation
        with Two (2) Data Recorder Interface Modules, 80255, and Four (4) DAX         80110-116*   80140-116*
        Modules, 80016, plus Keyboard
    * Requires use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
      (Please see catalog section B-13-1 for information on the SEA/R).

    ** For unidirectional applications, only two island modules are required.
      Specify unidirectional application when ordering.

    NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
                                                                                                         B-1-7

GRADE CROSSING PREDICTOR
SINGLE TRACK, WITHOUT DAX
                                      MODEL 3000ND


                                                                 ECONOMICAL, NONREDUNDANT,
                                                                 SINGLE TRACK SYSTEM,
                                                                 WITHOUT DAX
                                                                 USES STANDARD 3000 GCP
                                                                 PLUG-IN MODULES
                                                                 CASE ACCOMMODATES A DATA
                                                                 RECORDER INTERFACE
                                                                 MODULE




The Model 3000ND Grade Crossing Predictor is a nonredundant, single track system without provisions
for DAX modules and is intended for use at locations where the DAX capability is not required. The single-
bay case is designed for shelf, backboard, or 23-inch rack mounting and houses a single module set plus
an optional data recorder interface module (80255) for monitoring GCP/crossing operation when used with
the Safetran Event Analyzer/Recorder (SEA/R), 80250. The standard plug-in keyboard assembly (80019)
is used to program the unit.

The Model 3000ND GCP provides the prime prediction offset feature, and when used in a remote applica-
tion, can effectively operate as a DAX for controlling a remote crossing. The 3000ND GCP features an
independent island circuit, as well as ENABLE and UAX terminals. Slaving capabilities are also provided.
B-1-8

                                       SPECIFICATIONS
                                         MODEL 3000ND GCP
    Dimensions:                             14.375 inches (36.51 centimeters) high
                                            23 inches (58.42 centimeters) wide
                                            11.34 inches (28.80 centimeters) deep

    Weight:                                 22 pounds (9.98 kilograms) (approximate)

    Refer to the Instruction and Installation Manual for Model 3000 GCP Family for applicable system
    specifications.




                           ORDERING INFORMATION
                                         MODEL 3000ND GCP
                                     To order, specify description and part number.

                                          Description                                      Part Number
                                   ,
        Basic Model 3000ND GCP Nonredundant,
        Single Track Operation, without DAX
           Includes the following:
                                                                                       80050-001
             Case, 800052 (1) Intelligent Processor Island Module, 802211 (1)
             Transceiver Module, 80012 (1) Relay Drive Module, 80013 (1)
             Processor Module, 80214 (1) Controol Interface Module, 80020 (1)
                                   ,
        Basic Model 3000ND GCP Nonredundant, Single Track Operation,
                                                                                       80050-011*
        without DAX, with Data Recorder Interface Module, 80255
                                   ,
        Basic Model 3000ND GCP Nonredundant, Single Track Operation,
                                                                                       80050-101
        without DAX, with Keyboard
                                   ,
        Basic Model 3000ND GCP Nonredundant, Single Track Operation,
                                                                                       80050-111*
        without DAX, with Data Recorder Interface Module, 80255, and Keyboard
    * Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
      (Please see catalog section B-13-1 for information on the SEA/R).

    NOTE: For accessories and replacement parts, see page B-1-16 and B-1-17.
                                                                                                        B-1-9

GRADE CROSSING PREDICTOR
SINGLE TRACK, WITHOUT DAX
   REDUNDANT SYSTEM
                                    MODEL 3000ND2


                                                               TWO IDENTICAL MODULE
                                                               SETS WITH AUTOMATIC
                                                               TRANSFER IN THE EVENT
                                                               OF A MALFUNCTION
                                                               ECONOMICAL SYSTEM
                                                               USES STANDARD 3000 GCP
                                                               PLUG-IN MODULES
                                                               CASE ACCOMMODATES
                                                               TWO DATA RECORDER
                                                               INTERFACE MODULES




The Model 3000ND2 Grade Crossing Predictor is a redundant, single track system without provision for
DAX modules and is intended for use at locations where the DAX capability is not required. The single-bay
case is designed for shelf, backboard, or 23-inch rack mounting and houses two identical module sets
plus a single transfer module, with one module set functioning as the primary system while the other
serves as the backup. In the event of a failure of one system, control is automatically switched to the
other. The unit can also accommodate a pair of optional data recorder interface modules (80255) for
monitoring GCP/crossing operation when used with the Safetran Event Analyzer/Recorder (SEA/R), 80250.
The standard plug-in keyboard assembly (80019) is used to program both module sets without the need to
relocate the keyboard.
B-1-10

                                    SPECIFICATIONS
                                     MODEL 3000ND2 GCP
    Dimensions:                          14.375 inches (36.51 centimeters) high
                                         23 inches (58.42 centimeters) wide
                                         11.34 inches (28.80 centimeters) deep

    Weight:                              30 pounds (13.61 kilograms) (approximate)

    For operation and general specifications, see catalog page B-1-2
    Refer to the Instruction and Installation Manual for the Model 3000 GCP Family for applicable system
    specifications.




                        ORDERING INFORMATION
                                  To order, specify description and part number.

                                       Description                                        Part Number
                               ,
    Basic Model 3000ND GCP Single Track Operation,
    Automatic Transfer, without DAX
      Includes the following:
        Case, 80151 (1) Intelligent Processor Island Module, 80211 (1)               80150-001
        Transceiver Module, 80012 (1) Relay Drive Module, 80013 (1)
        Processor Module, 80214 (2) Control Interface Module, 80029 (1)
        Transferb Module, 8800028 (1)
                               ,
    Basic Model 3000ND GCP Single Track Operation,
    Automatic Transfer, without DAX, with Two (2) Data Recorder Interface Modules,   80150-011*
    80255
                               ,
    Basic Model 3000ND GCP Single Track Operation,
                                                                                     80150-101
    Automatic Transfer, without DAX, with Keyboard
                               ,
    Basic Model 3000ND GCP Single Track Operation,
    Automatic Transfer, without DAX, with Two (2) Data Recorder Interface            80150-111*
    Modules, 80255 and Keyboard
    * Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
      (Please see catalog section B-13-1 for information on the SEA/R).

    NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
                                                                                                                   B-1-11

 EIGHT-DAX MICROPROCESSOR
   BASED GRADE CROSSING
         PREDICTOR
                                  MODELS 3008/3008D2

                                                              UP TO EIGHT SEPARATE
                                                              DAX CIRCUITS CONTROLLED
                                                              FROM A SINGLE GCP
                                                              EXCEPT FOR THE TRANSFER
                                                              TIMER, USES STANDARD 3000
                                                              GCP PLUG-IN MODULES
                                                              UNIDIRECTIONAL OR
                                                              SIMULATED BIDIRECTIONAL
                                                              OPERATING MODES
                                                              FULL SYSTEM REDUNDANCY
                                                              PROVIDED BY THE MODEL
                                                              3008D2 GCP

In areas where multiple highway grade crossings are encountered, a Model 3000/3000D2/3000D2L GCP can be
used to control the warning devices located at adjacent crossings. This technique is referred to as DAXing
(downstream adjacent crossing) and a DAX module is used to accomplish this function. Each DAX module
consists of two identical DAX circuits and each DAX circuit provides an independently programmed, constant
warning time to extend the warning time of the prime unit.

The Model 3000/3000D2/3000D2L GCP contains a maximum of two DAX modules (four DAX circuits), and a
separate DAX circuit must be assigned to each track at multiple highway rail crossings. Therefore, on single- or
multiple-track railroads, the number of DAX circuits available determines the number of adjacent crossings that
can be controlled.

The single-track Model 3008 and 3008D2 GCPs provide eight independent DAX circuits for controlling up to
eight adjacent crossings. While the cases are essentially identical to those of their four-DAX counterparts, the
second transceiver and island modules have been omitted to accommodate the additional DAX modules. The
3008/3008D2 GCPs can be operated in either unidirectional or simulated bidirectional modes. In multiple-track
crossing applications, a Model 3008/3008D2 GCP must be used for each track.a

With the exception of a different automatic transfer timer module (80037), which is required in 3008D2 units
only, all modules are identical to those used in the rest of the Model 3000 GCP family. Similarly, the Model
3008D2 GCP case is equipped with two identical module sets, as are the 3000D2 and 3000D2L, plus the
automatic transfer timer module, with one module set serving as the primary system and the other as the
backup. In the event of a failure of the primary system, control is automatically switched to the backup system.
B-1-12

                                    SPECIFICATIONS
    For operation and general specifications, see catalog page B-1-2. Refer to the Instruction and Installation
    Manual for the Model 3000 GCP family for applicable system specifications.




                        ORDERING INFORMATION
                                         MODEL 3008 GCP
                                   To order, specify description and part number.

                                       Description                                           Part Number
     Basic Model 3008 Eight-DAX GCP
       Includes the following:
         Case, 80006 (1) Intelligent Processor Island Module, 80211 (1)
                                                                                       80005-003
         Transceiver Module, 80012 (1) Relay Drive Module, 80013 (1)
         Processor Module, 80214 (1) DAX Module, 80016 (3)
         Control Interface Module, 80020 (1)
     Basic Model 3008 Eight-DAX GCP with Four (4) DAX
                                                                                       80005-004
     Modules, 80016
     Basic Model 3008 Eight-DAX GCP with Three (3) DAX Modules, 80016,
                                                                                       80005-013*
     and Data Recorder Interface Module, 80255
     Basic Model 3008 Eight-DAX GCP with Four (4) DAX Modules, 80016,
                                                                                       80005-014*
     and Data Recorder Interface Module, 80255
     Basic Model 3008 Eight-DAX GCP with Three (3) DAX Modules, 80016,
                                                                                       80005-113*
     Data Recorder Interface Module, 80255, plus Keyboard
     Basic Model 3008 Eight-DAX GCP with Four (4) DAX Modules, 80016,
                                                                                       80005-114*
     Data Recorder Interface Module, 80255, plus Keyboard
    * Requires use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
      (Please see catalog section B-13-1 for information on the SEA/R).

    NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
                                                                                                B-1-13

         ORDERING INFORMATION (CONT.)
                                 MODEL 3008D2 GCP
                             To order, specify description and part number.

                                  Description                                     Part Number
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer
  Includes the following:
    Case, 80009 (1) Intelligent Processor Island Module, 80211 (2)
                                                                              80010-006
    Transceiver Module, 80012 (2) Relay Drive Module, 80013 (2)
    Processor Module, 80214 (2) DAX Module, 80016 (6)
    Control Interface Module, 80020 (2) Transfer Timer Module, 80037 (1)
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer, with Eight (8)
                                                                              80010-008
DAX Modules, 80016
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer, with Six (6)
                                                                              80010-016*
DAX Modules, 80016, and Two (2) Data Recorder Interface Modules, 80255
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer, with Eight (8)
                                                                              80010-018*
DAX Modules, 80016, and Two (2) Data Recorder Interface Modules, 80255
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer, with Six (6)
DAX Modules, 80016, Two (2) Data Recorder Interface Modules, 80255,           80010-116*
plus Keyboard
                                      ,
Basic Model 3008D2 Eight-DAX GCP Automatic Transfer, with Eight (8)
DAX Modules, 80016, Two (2) Data Recorder Interface Modules, 80255,           0010-118*
plus Keyboard
* Requires the use of Safetran's Event Analyzer/Recorder (SEA/R), 80250.
 (Please see catalog section B-13-1 for information on the SEA/R).

NOTE: For accessories and replacement parts, see pages B-1-16 and B-1-17.
B-1-14

                                 DATA RECORDER
                               INTERFACE MODULE
                                   80255 (80265)
                            (FOR MODEL 3000 GCP FAMILY)

    Safetran's low-cost, data recorder interface modules are designed for use in any of the Model 3000 Grade
    Crossing Predictor Family cases. These modules provide an interface to the Safetran Event Analyzer/Recorder
    (SEA/R), 80250, and allow the SEA/R to record the same data types as previously recorded by the 80015 Data
    Recorder Module (i.e., warning time, speed and diagnostic data). The data is sent through the 3000 GCP front
    panel 25-pin connector to the external data recorder via an Echelon® two-wire communication link. This
    communication link also allows all 3000 GCP units at a crossing (each equipped with an interface module and
    80063 interface connector), to transmit data over a common Echelon® link to a single external SEA/R recorder.
    This permits all data from multiple 3000 GCP's to be recorded on one recorder, thus simplifying data retrieval
    and analysis.

    A80255 Recorder Interface Module
    The 80255 Data Recorder Interface Module is available for use in the new dual-frequency 3000 GCP cases in
    conjunction with the new 80214 Processor Module. Besides the low cost and simplicity of the 80255, it simpli-
    fies future expansion of the 3000 GCP diagnostic messages that are sent to the SEA/R recorder. The 80255
    module is only for use with the 80214 processor in the 3000 GCP cases, and may also be used in all Model
    2000 Motion Sensor units.

    A80265 Recorder Interface Module
    The 80265 Data Recorder Interface Module is a retrofit device that provides the interface between any
    3000 GCP currently in service and equipped with either the 80014 or 80044 processor module, and the SEA/R.

    The two new data recorder interface modules replace the 80015 module which was phased out of production
    due to the manufacturer (Motorola) obsoleting the 68008 microprocessor chip.



    Echelon® is a registered trademark of Echelon Corporation.
                                                                                                            B-1-15

                                SPECIFICATIONS
Input Power:
   Voltage                          9-16.5 VDC (supplied from host equipment)

    Current                         0.40 ampere (maximum)

Echelon® Interface:                 80265 module provides the Echelon® interface
                                    80255 module uses the Echelon® interface on the 80214 and 80224
                                    modules

Surge Protection:                   Built-in tertiary surge protection. Secondary protection provided by
                                    mothergoard in host case.

Environmental:
   Temperature                      -40 degrees F to +160 degrees F (-40 degrees C to +71 degrees C)

    Humidity                         95%, noncondensing

Weight:                             80255 module - 5 ounces (0.14 kilogram) (approximate)
                                    80265 module - 7 ounces (0.20 kilogram) (approximate)




                    ORDERING INFORMATION
To order, specify data recorder interface module, plus the appropriate part number from the table below.

    Part Number                                           Applications
                      Retrofit device for use in all current 3000 GCP cases with 80014 or 80044 processor
 80265
                      module, or in 2000 Motion Sensor
                      Use in dual-frequency 3000 GCP cases with 80214 processor module only, or in 2000
 80255
                      Motion Sensor
                      MS/GCP Interface Connector (interfaces 2-wire Echelon® link to front-panel 25-pin
 80063*
                      connector and provides connections to daisy-chain multiple cases)


* Provided with new cases containing 80255/80265 module or when 80255/800265 module ordered separately.
B-1-16

                                        ACCESSORIES
                                  MODEL 3000 GCP SERIES
                                     Description                                       Part Number
     Automatic Transfer Timer Unit                                             80024 (1)***
     Bidirectional Simulation Coupler                                          62664-Mf (5)
     Tunable Insulated Joint Bypass Coupler                                    62785-f (5)
     Data Recorder Interface Unit (for use with 80015 module only)             80025 (5)
     Dual Wideband Shunt                                                       8A077A (5)
     Extender Module                                                           80021 (5)
     MS/GCP Termination Shunt Burial Kit                                       62776 (5)
     Multi-frequency Narrow-band Shunt, 156-430 Hz                             62775-1543 (5)*
     Multi-frequency Narrow-band Shunt, 210-326 Hz                             62775-2132 (5)
     Multi-frequency Narrow-band Shunt, 211-525 Hz                             62780-2152 (5)
     Multi-frequency Narrow-band Shunt, 348-483.5 Hz                           62775-3448 (5)
     Multi-frequency Narrow-band Shunt, 348-970 Hz                             62775-3497 (5)*
     Multi-frequency Narrow-band Shunt, 522-746.8 Hz                           62775-5274 (5)
     Multi-frequency Narrow-band Shunt, 790-1034 Hz                            62775-7910 (5)
     Multi-frequency Narrow-band Shunt, 86-211 Hz                              62775-8621 (5)*
     Multi-frequency Narrow-band Shunt, 86-211 Hz                              62780-8621 (5)*
     Multi-frequency Narrow-band Shunt, 156-430 Hz                             62780-1543 (5)*
     Multi-frequency Narrow-band Shunt, 525-970 Hz                             62780-5297 (5)*
     Narrow-band Shunt                                                         62775-f (5)
     Narrow-band Shunt                                                         62780-f (5)
     Surge Panel                                                               80026-1 (5)
     Surge Panel                                                               80026-2 (1)**
     Wideband Shunt                                                            8A076A (5)
     Simulated Track Assembly                                                  80071 (5)
     Simulated Track Burial Assembly                                           80074 (5)
     Simulated Track Inductor                                                  8V617 (5)
     Solid-state Vital and Gate                                                90975 (5)
     3000 GCP Slaving Unit                                                     80065 (5)
     Adjustable Inductor Assembly                                              8A398-6 (5)
     * See Application Guidelines Manual for usage.
     ** Both 80026-1 and 80026-2 Surge Panels are required for two-track operation.
     *** Provides automatic transfer between two Model 3000 GCP single or two-track operation units,
         or two Model 3000ND GCP single track units.

     (Specify frequency-f)

     Models with which accessories can be used:
            (1) 3000/3000D2/3000D2L
            (5) Entire 3000 GCP Family
                                                                                                             B-1-17

                                REPLACEMENT PARTS
                                   MODEL 3000 GCP SERIES
                                          Part                               Used On
                  Item
                                          No.
                                                   3000   3000D2   3000ND   3000ND2    3008   3008D2   3000D2L
Case, Eight-DAX GCP                      80006                                          X
Case, Eight-DAX GCP, Automatic
                                         80009                                                  X
Transfer
Case, One/Two-Track Operation            80001      X

Case, One/Two-Track Automatic Transfer   80101              X

Case, Single-Track, Without DAX          80052                       X

Case, One/Two-Track Automatic Transfer   80131                                                           X
Case, Single-Track, Without DAX,
                                         80151                                X
Auto Transfer
Control Interface Assembly               80020-1    X       X        X                  X       X        X

Control Interface Assembly               80020-2            X                                            X

Control Interface Module                 80029                                X

Data Recorder Interface Module *         80255      X       X        X        X         X       X        X

Data Recorder Interface Module **        80265      X       X        X        X         X       X        X

DAX Module                               80016      X       X                           X       X        X

Intelligent Processor Island Module      80211      X       X        X        X         X       X        X

Keyboard/Display Control Unit            80019-1    X       X        X        X         X       X        X

Processor Module                         80214      X       X        X        X         X       X        X

Relay Drive Module                       80013      X       X        X        X         X       X        X

Transceiver Module                       80012      X       X        X        X         X       X        X

Transfer Module                          80028              X                 X                          X

Transfer Timer Module                    80037                                                  X

* For use with 80214 Processor only.

** For use with 80014, 80044, and 80214 processor modules.

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:875
posted:4/26/2010
language:English
pages:17
Description: Safetran DUAL-FREQUENCY GRADE CROSSING PREDICTORS