Underground Fiber Optic Cable Sheave
Document Sample


5 Blue Heron Drive
Comstar supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Limited Warranty USER GUIDE USER GUIDE USER GUIDE
Condux International, Inc. extends the following warranty to the original
purchaser of these goods for use, subject to the qualifications indicated: Underground Fiber Optic
Condux International, Incorporated warrants to the original purchaser for use
that the goods or any component thereof manufactured by Condux
Cable Sheave
International will be free from defects in workmanship for a period of one year
from the date of purchase, provided such goods are installed, maintained, and
used in accordance with Condux’s written instructions.
Components not manufactured by Condux International but used within the
assembly provided by Condux International are subject to the warranty period
as specified by the individual manufacturer of said component, provided such
goods are installed, maintained, and used in accordance with Condux’s and
the original manufacturer’s written instructions.
Condux’s sole liability and the purchaser’s sole remedy for a failure of goods
under this limited warranty, and for any and all claims arising out of the
purchase and use of the goods, shall be limited to the repair or replacement of
the goods that do not conform to this warranty.
To obtain repair or replacement service under the limited warranty, the
purchaser must contact the factory for a Return Material Authorization (RMA).
Once obtained, send the RMA along with the defective part or goods,
transportation prepaid, to: Condux International, Inc.
145 Kingswood Road
Mankato, MN 56001
THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS
OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE.
CONDUX ASSUMES NO LIABILITY IN CONNECTION WITH THE
INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN
THIS LIMITED WARRANTY. CONDUX WILL IN NO
EVENT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
®
CONDUX
Condux International, Inc. • P.O. Box 247 • 145 Kingswood Road • Mankato, MN 56001
507-387-6576 • 800-533-2077 • FAX 507-387-1442
Internet: http://www.condux.com © Copyright 1996, Condux International, Inc.
Printed in USA ®
Literature Part Number: 08637898
Revision Number: 1.0 CONDUX
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
The Underground F/O Cable Sheave is ready to use. It is equipped with For existing cable, do steps 1-5 above and the following steps:
special guides to eliminate the cable from becoming pinched between the
sheave wheel and the tie-off arm. 6. Remove the hair pin from the end of the locking shaft. Pull the
locking shaft free from the swing arm.
Installation Instructions 7. Rotate the swing arm away from the hook and locking shaft.
8. Insert the cable through the arm’s opening and onto the sheave
1. Clean the sheave, free of sludge before use. wheel.
2. Securely fasten a rope or chain to the sheave’s attachment eye. 9. Rotate the swing arm back into position and re-install the locking
3. Lower the sheave into the shaft and hair pin.
manhole, and align the
bottom of the sheave Removal Instructions
wheel with the duct
opening. 1. Remove the hair pin from the end of the locking shaft. Pull the
4. Attach a rope or chain to locking shaft free from the swing arm.
the tie-off hook, and 2. Rotate the swing arm away from the hook and locking shaft.
attach it to a pulling-in
iron that is opposite to the 3. Remove the cable from the sheave and the arm’s opening.
direction of the pull (see
Figure 1). 4. Rotate the swing arm back into position and re-install the locking
shaft and hair pin.
5. Ensure that the sheave
wheel can rotate freely. 5. Unfasten the rope or chain from the tie-off hook.
6. Lift the sheave out of the manhole, and remove the rope or chain
from its attachment eye.
7. Clean the sheave and properly store it.
Figure 1. Installation Configuration
!WARNING: Read and understand all procedure !WARNING: Do not remain in the manhole when
and safety instructions before using the pulling cable. The cable, sheave, and tie-offs are
Underground F/O Cable Sheave. Failure to do so under tension. If a component fails and releases its
may result in personal injury or property damage. stored energy, serious personal injury or death
Save this user’s guide for future reference. could result.
ADVERTENCIA !ADVERTENCIA: Favor de leer y comprender todas !WARNING: Stay clear of the rotating sheave wheel.
las instrucciones de operación y seguridad antes Failure to do so could result in serious personal
de usar el Underground F/O Cable Sheave. Si Ud. injury.
Instrucciones
de Operación no comprende las instrucciones favor de
consultarle a su jefe.
!CAUTION: Follow all standard manhole opening !WARNING: Do not exceed 1500 lbs. of pulling
procedures, including work area protection and gas force. Failure to do so could result in serious
detection. Wear personal protective equipment: personal injury or property damage.
hard hat, safety glasses, safety shoes, and leather
work gloves. Failure to do this could result in
personal injury.
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com