					                                                                            APPEL D’OFFRES
                                                                         INVITATION TO TENDER
                                                                           No UC – 0410027(DD)

 Purchasing Services                               Date et heure limite pour la présentation des propositions
 1550, de Maisonneuve W.                                        Proposal closing date and time:
 Suite GM1003                                           24 January, 2005 at 10:00AM (local time)
 Montreal, (Quebec)
 H3G 1N2                                    Pour renseignements, s‘adresser à / Address inquiries to:
                                            Mr. Daniel Dorval               Tel.: (514) 848-2424 (x4048)
                                            Senior Project Buyer            Fax: (514) 848-3660
                                            E-mail:        ddorval@alcor.concordia.ca


Vous êtes invités à présenter une proposition à l‘égard des biens et / ou des services énumérés ci-après,
conformément aux conditions ci-dessous.


You are invited to submit a proposal for the goods and / or services listed below, subject to the terms and conditions
set out herein.


                                INVITATION TO TENDER - APPEL D’OFFRES

  Supply and Installation of a NORDX/CDT IBDN Cabling System for the New Drummond Science
                                           Building


Par la présente, nous offrons de vendre à l‘Université Concordia, conformément aux conditions mentionnées ci-
après, les biens et/ou services énumérés ci-après, au(x) prix indiqué(s).
We hereby offer to provide Concordia University, in accordance with the terms and conditions herein, the goods
and/or services listed below at the price(s) indicated.


 À REMPLIR PAR LE SOUMISSIONNAIRE / TO BE COMPLETED BY THE TENDERER
 Raison sociale et adresse                                No. de téléphone                No. de télécopieur
 Corporate name and address                               Phone No.                       Fax No.


                                                          Délai de livraison              Termes de paiement
                                                          Delivery date                   Payment terms




 Nom et titre du fondé de pouvoir                         Signature                       Date
 Name and title of official of firm




                                                       Page 1
Initials: _______________
   Purchasing Services                                                                         Tender Document No. UC – 0410027(DD)


                                                             TABLE DES MATIÈRES


1.0    INTRODUCTION ......................................................................................................................................... 4
1.1     Principal Tender Contact and Coordination.................................................................................................. 4
1.2     Key Dates...................................................................................................................................................... 4
1.3     Tender Closing Date ..................................................................................................................................... 4
2.0    INSTRUCTIONS TO TENDERERS ........................................................................................................... 5
2.1     Objective....................................................................................................................................................... 5
2.2     Definitions .................................................................................................................................................... 5
2.3     Clarification of the Tender Document .......................................................................................................... 5
2.4     Quoted Prices ................................................................................................................................................ 5
2.5     Conditions Governing the Proposal Preparation ........................................................................................... 6
2.6     Tenderer Experience and Qualifications ....................................................................................................... 7
2.7     Rejection of Proposals .................................................................................................................................. 8
2.8     Opening of Tenders ...................................................................................................................................... 8
2.9     Evaluation by committee .............................................................................................................................. 8
2.10    Selection Criteria .......................................................................................................................................... 8
2.11    Priority of Terms and Conditions.................................................................................................................. 9
2.12    Validity Period of Tenders............................................................................................................................ 9
2.13    Additional Information ................................................................................................................................. 9
2.14    Proposal(s) retained ...................................................................................................................................... 9
2.15    Acceptance of Tenders................................................................................................................................ 10
2.16    Omissions and Discrepancies...................................................................................................................... 10
3.0    TERMS AND CONDITIONS ..................................................................................................................... 11
3.1     Terms of Payment ....................................................................................................................................... 11
3.2     Supplemental Purchases and Change Requests........................................................................................... 11
3.3     Project Management ................................................................................................................................... 12
3.4     Delivery ...................................................................................................................................................... 12
3.5     Installation test and certification ................................................................................................................. 12
3.6     Performance Guarantee ............................................................................................................................... 12
3.7     Warranty ..................................................................................................................................................... 13
3.8     Training ...................................................................................................................................................... 14
3.9     Verification ................................................................................................................................................. 14
3.10    Indemnity .................................................................................................................................................... 14
3.11    Default ........................................................................................................................................................ 14
3.12    Force majeure ............................................................................................................................................. 15
3.13    Insolvency ................................................................................................................................................... 15
3.14    Termination................................................................................................................................................. 15
3.15    Insurance ..................................................................................................................................................... 15
3.16    Presence on Concordia University‘s premises ............................................................................................ 15
3.17    Confidentiality ............................................................................................................................................ 16
3.18    Intellectual Property.................................................................................................................................... 16
3.19    Resolution of Dispute ................................................................................................................................. 17
3.20    Patents......................................................................................................................................................... 18
3.21    Notices ........................................................................................................................................................ 18
3.22    Assignment of contract ............................................................................................................................... 18
3.23    Sub-contracting ........................................................................................................................................... 18
3.24    Waiver ........................................................................................................................................................ 18
3.25    Successors and assigns ................................................................................................................................ 18
3.26    Publicity ...................................................................................................................................................... 18
3.27    Governing laws ........................................................................................................................................... 18


                                                                       Page 2 de 44
       Purchasing Services                                                                        Tender Document no. UC – 0410027(DD)


3.28     Language..................................................................................................................................................... 18
4.0    PROJECT TECHNICAL REQUIREMENTS .......................................................................................... 19
4.1      General........................................................................................................................................................ 19
4.2      Reference Standards ................................................................................................................................... 19
4.3      Inclusions .................................................................................................................................................... 20
4.4      DS Building Requirements ......................................................................................................................... 21
4.5      Detailed Technical Requirements ............................................................................................................... 21
4.6      Submittals ................................................................................................................................................... 24
4.7      Delivery, Storage and Handling .................................................................................................................. 25
4.8      Acceptance.................................................................................................................................................. 25
5.0    Vendor Questionnaire ................................................................................................................................. 26
5.1      General........................................................................................................................................................ 26
5.2      Financial Information.................................................................................................................................. 26
5.3      Proposed System ......................................................................................................................................... 26
5.4      System Architecture .................................................................................................................................... 26
5.5      System/Station features ............................................................................................................................... 26
5.6      Labelling Schema: ...................................................................................................................................... 27
5.7      Training: ..................................................................................................................................................... 27
6.0    FORM OF TENDER ................................................................................................................................... 28
6.1      Agreement................................................................................................................................................... 28
6.2      Signing authority......................................................................................................................................... 28
6.3      Description of the Price Schedule Line items ............................................................................................. 29
6.4      Price Schedule ............................................................................................................................................ 30
6.5      Optional Items ............................................................................................................................................ 30
6.6      Optional MAC Contract ........................................................................... Error! Bookmark not defined.32
6.7      Additional Information ............................................................................ Error! Bookmark not defined.32
6.8      Addenda ...................................................................................................................................................... 31
Annex 1 General Project Scedule ............................................................................................................................. 32
Annex 2 Vertical Cabling Requirements ................................................................................................................. 33
Annex 3 Typical Telecom Closet Rack Layout ....................................................................................................... 34
Annex 4 Telecom Room Rack Layout ...................................................................................................................... 35
Annex 5 Analog Cable Layout .................................................................................................................................. 36
Annex 6 EH&S Regulations ...................................................................................................................................... 37




Initials: __________                                                    Page 3 de 44
      Purchasing Services                                            Tender Document no. UC – 0410027(DD)



1.0          INTRODUCTION
             Concordia University is requesting tender proposals for the complete supply and installation of a
             NORDX/CDT IBDN Structured Cabling System that will support all voice and data applications for
             the new Drummond Science Building of the Loyola campus of Concordia University.


1.1          Principal Tender Contact and Coordination

                          Concordia University
                          Purchasing Services
                          Suite GM 1003
                          1550 Boul. de Maisonneuve W.
                          Montreal, Quebec, H3G 1N2
                          Mr. Daniel Dorval
                          Senior Project Buyer
                          Phone: (514) 848-2424 (x4048)
                          Fax : (514) 848-3660
                          Email: ddorval@alcor.concordia.ca

1.2          Key Dates
             Listed below are the important events and the target dates and time by which the events are expected to
             be completed:

                 Issue of Tender Document                       January 7, 2005
                 Inquiries Final Deadline                       January 20, 2005
                 Tender closing date                            January 24 , 2005

             Note that no site tour is planned for this tender process.


1.3          Tender Closing Date
             Only those tenders physically received at the above-mentioned offices, by January 24th, 2005 at
             10:00AM (local time), will be considered. Tenders must respect this deadline or it will be rejected.




Initials: __________                              Page 4 de 44
      Purchasing Services                                          Tender Document no. UC – 0410027(DD)


2.0          INSTRUCTIONS TO TENDERERS

2.1          Objective
             This document is intended to provide a description of the goods and services that will be required from
             the selected certified NORDX/CDT IBDN cabling system installer.


2.2          Definitions
             Concordia University will hereafter be referred to as the ‗University‘.
             Certified NORDX/CDT IBDN cabling system vendors and installers that will be presenting a proposal
             will hereafter be referred to as the ‗Tenderer‘


2.3          Clarification of the Tender Document
             No officer, agent or employee of Concordia University is authorized to explain or interpret orally any
             part of the Tender Document. Any Tenderer requiring clarification of any part of the Tender
             Document shall do so in writing or by facsimile to Mr. Daniel Dorval, Senior Project Buyer.
             Inquiries shall be submitted only by prospective Tenderers and not by sub-contractors or third parties.
             Any additions or corrections to the Tender Document will be issued as a written addendum and will be
             forwarded to all Tenderers participating in the process. The Tenderers are required to include in their
             proposal a signed copy of each of the addenda to show that they have reviewed and understood each
             addendum issued. All addenda will prevail on the clauses and/or the documentation which they
             modify.

             Contact:
                                   Mr. Daniel Dorval
                                   Senior Project Buyer
                                   E-mail: ddorval@alcor.concordia.ca
                                   Fax: (514) 848-3660


2.4          Quoted Prices
2.4.1        Tenderers are requested to enter their quoted prices in the tables provided for in this document. Any
             additional pricing information that the Tenderer judges missing in this document must be included in
             the proposal document as an annex and/or identified clearly in the main body of the proposal
             document.
2.4.2        All prices and rebates shall remain firm until September 30, 2005.
2.4.3        All priced quoted must be in Canadian dollars.
2.4.4        The above-mentioned prices shall be F.O.B. destination, (exact location to be determined) and all
             shipping; handling, insurance and duty fees will be at the Tenderer (s) expense. (if applicable)
2.4.5        The above-mentioned prices must exclude all applicable taxes
2.4.6        Payment terms are net 45 days unless otherwise specified in writing by the University.




Initials: __________                             Page 5 de 44
      Purchasing Services                                          Tender Document no. UC – 0410027(DD)



2.5          Conditions Governing the Proposal Preparation
2.5.1        The following items must be included in the proposal submitted:
                A proposal that complies fully with all terms and conditions of the tender document.
                The original Tender Document with all the appropriate sections filled out and signed. Each page
                 must be initialled indicating acceptance of all conditions contained within it.
                A certified resolution, signed under corporate seal, of the Board of Directors of the Tenderer
                 which authorizes the signing officers to sign this tender document.
                Show that the Tenderer meets or exceeds the Tenderer Experience criteria. This information may
                 be provided in a separate annex of your proposal.
                Response to the Vendor Questionnaire and included as an annex to your proposal document
                A detailed list of the tasks to be completed including the dates for when these tasks must be
                 completed in order to meet the overall project schedule as described in Annex 1. Should the
                 schedule as described in Annex 1 not be possible then the Tenderer must clearly state the reasons
                 for this.
                A detailed list of the constraints and potential risks to the project along with a description of the
                 measures that will need to be taken to minimize or address these problems.
                That all proposal annexes be clearly identified in the body of the proposal document.
                Proof of insurance.
                All sections of the proposal must be typed
                The proposal may be prepared in either French or English.

2.5.2        The University assumes no obligation for any costs incurred by the Tenderers in the preparation of the
             proposal. Nor the return of any information and material submitted as part of the proposal or a
             commitment on the part of Concordia University to purchase or retain, in whole or in part, any
             products.
2.5.3        The Tenderer consents that the content of the proposal submitted to the University shall be deemed to
             constitute confidential information and shall not be disclosed or divulged, directly or indirectly, for
             any purpose whatsoever.
2.5.4        No faxed or emailed proposals will be accepted.
2.5.5        No modifications may be made to the submitted proposals after the tender closing date, unless
             explicitly requested in writing by the University. All submitted proposals become the property of the
             University. The University reserves the right to copy any part of the proposal documentation. These
             copies are to be used for internal purposes only or to conform to any law that may require such copies
             be provided. All information provided in your proposal shall be considered confidential information.
2.5.6        Tenderers shall provide a DETAILED list of any and all non-conformity and/or deviations to any
             terms, conditions or requirements of the tender document. Tenderers who do not comply with the
             request for full disclosure of non-compliances and/or deviations may have their Proposal invalidated
             for award.


2.5.7        Tenders are to be submitted in four (4) paper copies with one (1) marked original, and one (1)
             software copy and shall be delivered by hand or mailed in a sealed envelope clearly marked ―Supply
             and Installation of a NORDX/CDT IBDN Cabling System for the New Drummond Science
             Building”, Project No. UC – 0410027(DD)‖ and addressed as follows:
             Mail and Hand Delivery Address:



Initials: __________                             Page 6 de 44
      Purchasing Services                                          Tender Document no. UC – 0410027(DD)


                          Mr. Daniel Dorval
                          Senior Project Buyer
                          Concordia University
                          Purchasing Services,
                          Suite GM 1003
                          1550 de Maisonneuve Blvd W.
                          Montreal, Quebec
                          H3G 1N2


2.6          Tenderer Experience and Qualifications

2.6.1        General

             Tenderers are requested to show proof of experienced in installation of systems similar in size and
             scope to those required for this project and meet the following criteria:

               a)        At least five years experience with equipment and systems specified.
               b)        Be a franchised dealer or authorized dealer for the systems and components specified.
               c)        Maintain fully staffed and equipped service facility.
               d)        Provide at the time of the bid the name and relevant experience of the proposed project
                         manager.
               e)        At the request of Concordia University the Tenderer shall demonstrate that they have:
               f)        Adequate plant and equipment to complete the work within the agreed timetable.
               g)        Adequate staff with commensurate technical experience.
               h)        Properly licensed to perform the work in the province of Quebec.
               i)        Have staff in place to design and perform the shop drawing work.
               j)        Have offices and service staff/facilities located within 50 miles of the project.

2.6.2        Vendor

             The Vendor must be a NORDX/CDT-authorized Certified System Vendor (hereinafter referred to as
             CSV) of the selected IBDN Cabling System. The bidder must have successfully completed all IBDN
             design and installation training provided by NORDX/CDT.

             The vendor must have an R.C.D.D. (Registered Communication Distribution Designer) duly accepted
             by the BICSI (Building Industry Consulting Services International) under its employment. Proof of
             this status must be presented with the proposal.

             The Vendor, shall show proven expertise in the implementation of cabling projects. This expertise can
             be illustrated through the inclusion of details of at least three projects involving the design and
             installation of Category 6 unshielded twisted-pair (hereinafter referred to as UTP) cabling systems and
             optical fiber cabling systems within the past two (2) year period. Names, addresses and telephone
             numbers of references for the three projects shall be included.

             The Vendor shall accept complete responsibility for the design, installation, acceptance testing and
             certification of the selected IBDN Cabling System.



Initials: __________                            Page 7 de 44
       Purchasing Services                                           Tender Document no. UC – 0410027(DD)


              The Vendor shall provide proof of current CSV status and shall deliver the NORDX/CDT certification
              of the installed IBDN Cabling System.

2.6.3         Installer

              The installation of the selected IBDN Cabling System shall be performed by either employees of the
              Vendor or subcontractors. Organizations assigned as subcontractors shall be required to provide proof
              of NORDX/CDT authorization to install the selected IBDN Cabling System.

              All work shall be performed and supervised by technicians and managers qualified to install and test
              the selected IBDN Cabling System in accordance with NORDX/CDT requirements. The supervisor
              shall have successfully completed IBDN installation training provided by NORDX/CDT.

              In the event subcontractors are used for any portion of the installation or acceptance testing, the
              Vendor shall be responsible for any subsequent corrective action required on that portion.


2.7           Rejection of Proposals
              In default of conforming to any of the following conditions, Concordia University reserves the right to
              immediately reject the proposal of any Tenderer. These include:
               Not respecting the tender closing date deadline
               Omission, non-respect or limiting any of the terms as identified in this document
               Any proposals that limit any of the terms and conditions contained herein.


2.8           Opening of Tenders
              All submitted proposals shall be opened by Purchasing Services in the presence of an independent
              witness. The Tenderers will not be invited to the tender opening.


2.9           Evaluation by committee
              A committee comprised of members from various departments of Concordia University will evaluate
              each response to this tender document. Concordia University reserves the right to request any
              additional information it deems necessary in the evaluation of the Tenderers proposal.

2.10          Selection Criteria
              The proposals will be evaluated upon but not limited to the following criteria:
                      a) Satisfy all the requirements as outlined in this tender document,
                      b) Cost of the proposal,
                      c) Technical documentation submitted with proposal,
                      d) Corporate resource and financial stability,
                      e) Quality standards used for quality and service,
                      f) Experiences and references with similar undertakings in a university environment,
                      g) Information about company‘s human resources, and the resumes of its management
                          personnel.
                      h) MAC service proposal.
                      i) Training methodologies
                      j) Lead times, implementation plan and schedule, ability to deliver.
                      k) Additional added-value information provided by the Tenderer that may assist the
                          University in differentiating one Tenderer from another.


Initials: __________                              Page 8 de 44
       Purchasing Services                                         Tender Document no. UC – 0410027(DD)


2.11          Priority of Terms and Conditions
              The terms and conditions of this document will prevail over any other agreement unless accepted and
              agreed in writing by Concordia University.


2.12          Validity Period of Tenders
              Tenders shall be irrevocable and shall remain open for acceptance the ninetieth (90th) day from the
              tender closing date.

2.13          Additional Information
              Concordia University will make an evaluation based on the information submitted with the Proposal.
              In addition, Concordia University reserves the right to request further information that it deems
              necessary, including but not limited to on-site presentations.

2.14          Proposal(s) retained
              Following this Request for Proposal, Concordia University reserves the right to retain more than one
              proposal and to pursuit discussions with the selected Tenderer(s) prior to make a final decision with
              the contract award.




Initials: __________                             Page 9 de 44
       Purchasing Services                                          Tender Document no. UC – 0410027(DD)


2.15          Acceptance of Tenders
              The University reserves the right to reject any or all Proposals received and to accept any Proposal
              which it considers advantageous, whether or not it is the lowest priced Proposal. The University is
              under no obligation to award an order, and reserves the right to terminate the tender process at any
              time, and to withdraw from discussions with all or any of the Tenderers who have responded. Any
              proposal not supported by the information requested in the tender document, or not complying with the
              tender document, may not be considered in the Tenderer bidding process. The University assumes no
              obligation for any costs incurred by the Tenderer in the preparation of the proposal, nor the return of
              any information and material submitted as part of the proposal.

              The University intends to award an Agreement to the Tenderer whose Proposal offers the best value to
              the University, based upon the terms and conditions of the tender document and the specifications and
              service requirements indicated herein. However, the University is under no obligation to award any
              Agreement in whole or in part and the University reserves the right in its sole discretion to cancel the
              tender process at any time before or after closing without providing reasons for such cancellation.
              Rejection of all Proposals will mean that the University, in its own best interest at the time, has
              determined not to pursue the issue.

              In order to obtain the most advantageous offer for the University, the University reserves the right in
              its sole discretion:
               To waive irregularities and/or minor non-compliance by any Tenderer with the requirements,
                   specifications and terms and conditions of the tender document;
               To request clarification and/or further information from one or more Tenderers after closing
                   without becoming obligated to offer the same opportunity to all Tenderers; and
               Negotiate with the Tenderer selected as finalist to ensure that the best value is being obtained by
                   the University.

              The University reserves also the right to award the work on the basis of initial proposals received,
              without negotiations.

              Tenderers are advised however to submit a complete offer as their bid. Any waiver, clarification or
              negotiation will not be considered as an opportunity for Tenderers to correct errors in their bids.

2.16          Omissions and Discrepancies
              Should the Tenderers find any errors or omissions in the Tender Document, or doubt the meaning of
              any part of the document, Tenderers shall send their inquiries in writing to Mr. Daniel Dorval as
              indicated in Section 2.3.




Initials: __________                             Page 10 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)


3.0          TERMS AND CONDITIONS
3.1          Terms of Payment
3.1.1        Concordia University shall retain an amount equal to ten percent (10%) of the total purchase price due
             until the proposed NORDX/CDT IBDN cabling system is installed, certified and a final acceptance
             statement is provided by Concordia. The hold back monies shall be retained for a period of three (3)
             months after final acceptance.
3.1.2        The purchase price shall be payable to the Tenderer net thirty (30) days after reception of a formal
             invoice, in accordance with the following schedule:
                     a)   30 % of the purchase price upon the cabling system delivery and installation.
                     b) 60 % of the purchase price upon fulfillment of the certification and performance
                        guarantees as specified herein, the delivery of all user and technical documentation,
                        delivery and acceptance of all certification documentation and trace documentation, and
                        any other documentation stated herein.
                     c)   10 % of the purchase price upon release of the monies held back.
3.1.3        The invoices shall be sent to the following address:

                          Concordia University
                          1455 de Maisonneuve Blvd. West,
                          Suite GM 701,
                          Montreal, Quebec
                          H3G 1M8
                          ATT.: Accounts Payable

3.1.4        The invoices shall be in two (2) copies and the following data shall be indicated on it:

                             Purchase Order number;
                             A detailed description of the work performed;
                             Total cost.
3.1.5        The University reserves the right to retain partially and/or completely any of the payments described
             above if it assessed that the services provided do not conform to the terms and conditions as described
             herein, or that the Tenderer fails to respond adequately to instructions and/or directives issued by the
             University.


3.2          Supplemental Purchases and Change Requests
             All supplemental purchases and change requests require prior written approval by the University.
             Within 10 days of the issuance of a purchase order for this project the Tenderer and representatives of
             the University will agree on the format of a change order document that will be used for this purpose.




Initials: __________                            Page 11 de 44
      Purchasing Services                                            Tender Document no. UC – 0410027(DD)


3.3          Project Management
3.3.1        The following is expected of the Tenderer with regards to project management:
                A revised project schedule within 10 days after the issuance of the purchase order for this project.
                Keep a written record of all project meetings within this scope of this project
                Provide a brief bi-weekly status report which must contain the following information:
                Completed milestones
                Status of upcoming milestones
                List of potential risks and blockages which may affect the upcoming milestones


3.3.2        Concordia reserve its rights to modify, change and alter schedule dates best suited for the overall
             project to have the Tenderer complete delivery as specified in this offer, and the Tenderer agrees not
             to claim any additional costs or extras relating to schedule change or modifications from Concordia or
             its contractors.


3.4          Delivery
3.4.1        Time is of the essence.

3.4.2        The start of the project is targeted for 1st February, 2005. The project may be broken down into phases
             – to be discussed with the selected vendor.

3.4.3        In the event the Tenderer fails to complete delivery of the proposed NORDX/CDT IBDN cabling
             system within the agreed timeframes bound by this agreement, the University shall deduct from the
             purchase price a sum equal to five percent (1%) thereof for each day of delay in delivery incurred by
             the Tenderer, up to a maximum of twenty- five percent (15%) of the total purchase price; such sum
             shall be deducted from the instalment of the price due on delivery.

3.4.4        Should any building component need to be moved by the selected Tenderer‘s resources in the in the
             performance of the activities outlined in this contract (e.g. removal of ceiling tiles), the tendered shall
             agree to replace, at their expense, any such damaged component.


3.5          Installation test and certification
             All components of the selected NORDX/CDT IBDN cabling system shall be installed and certified by
             the Vendor. All certification must be confirmed in writing and duly signed by certified personnel as
             specified in this tender document. Notwithstanding the above, the Vendor shall, at its expense and
             within a reasonable time following the request from Concordia University, furnish the qualified
             personnel for the necessary period in order to supervise the installation, test and start up of the
             software and hardware and to advise the employees of Concordia University of the proper operation
             and maintenance thereof.
3.6          Performance Guarantee
             The Tenderer represents and guarantees that, when installed in the premises of Concordia University,
             in accordance with the Tenderer's instructions and manuals and without performance limitations
             unrelated to the Tenderer's supply, the systems proposed shall have continuous capacity as specified in
             the Tenderer's technical, instruction and user manuals.

             Concordia University is also requesting a 4 hour response time for any critical warranty service calls

Initials: __________                             Page 12 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)


             put in by the responsible technical representative assigned by Concordia University, and that a
             technician be dispatched on-site to perform all necessary repairs (or temporary replacements if
             required) within 24hrs.


3.7          Warranty
3.7.1        Qualification of System

             The installed IBDN Cabling System will be covered by a certification program provided by
             NORDX/CDT and the Tenderer.

             Payment of the 60% of the contract price, as stipulated in section 3.1.2, is subject to the delivery and
             acceptance of all applicable certification documentation proving that the cabling system passes all
             certification requirements.

             In cases where it is impossible to implement the requirements as per TIA/EIA-569-A, the cabling runs
             shall not exceed the maximum distances specified in ANSI/TIA/EIA-568-A and SP-4425 (TIA 568-
             B.1) and shall not in any manner diminish the performance of the selected IBDN Cabling System.

             The installed IBDN Cabling System shall conform to all applicable local building and electrical codes.

3.7.2        Certification

             To qualify for system certification, an IBDN Cabling System shall be designed, engineered, installed
             and tested by a certified CSV.

             To qualify for system certification, the installed cabling system shall fully comply with all relevant
             IBDN design and applications guidelines, including acceptable deviations as specified in the latest
             release of the IBDN Certification Guide.

             To qualify for system certification, only NORDX/CDT-approved products shall be used to ensure end-
             to-end system performance. The full NORDX/CDT product warranty and lifetime performance
             assurance can be provided only to systems built using products supplied by NORDX/CDT for IBDN.

             It is understood that NORDX/CDT will not provide certification coverage for other manufacturers‘
             products.

3.7.3        Lifetime Application Assurance
             IBDN certification shall provide the assurance that all present and future applications engineered for
             the performance level of the cabling system used will work for the lifetime of the certified IBDN
             Cabling System installed at Concordia University.

3.7.4        Corrective Action
             Should the certified IBDN Cabling System fail to support the application(s) designed to operate over
             it—whether at the time of cutover to the new cabling system, during subsequent use, or after upgrading
             to a newer supported application (for example, to a Gigabit Ethernet or an ATM network from a
             lower-speed network environment)—NORDX/CDT and the Vendor shall take prompt corrective
             action at no extra cost to Concordia University. The University requests a 24hr response time for all
             critical equipment fault calls.




Initials: __________                             Page 13 de 44
       Purchasing Services                                             Tender Document no. UC – 0410027(DD)


3.7.5         25-Year Product Warranty
              IBDN certification shall provide a twenty-five (25) year product warranty for all IBDN passive
              components used in the installed IBDN Cabling System at Concordia University. Defective and/or
              improperly installed products shall be replaced and/or correctly installed at no cost to the Concordia
              University.


3.8           Training
              Five (5) Concordia assigned personnel shall receive, at the Vendor(s)‘s expense, a complete training
              program for the support and maintenance of the installed IBDN structured cabling system in order to
              maintain IBDN certification.


3.9           Verification
              The University reserves the right to verify any Tenderer documentation related to the execution of this
              contract. The Tenderer shall be required to supply a copy of any documentation requested as part of
              this verification. This verification may be requested by the University in writing and a two (2)
              working day notification shall be provided. The Tenderer shall not bill the University for costs that
              may be incurred by this verification.


3.10          Indemnity
              The Tenderer shall indemnify and save harmless Concordia University, their employees and agents
              against all claims, losses and expenses from whatever source, and of whatever nature and kind arising
              out of Tenderer's performance of the contract or the work or the rendering of any services
              contemplated hereunder by the Tenderer or any of its employees or agents.

              It is understood that the contract is strictly between the Tenderer and Concordia University and in no
              way shall be interpreted as an employment relationship between Concordia University and the
              Tenderer's employees and should any differences arise between the Tenderer and any of its employees,
              it shall be resolved directly between them, and the Tenderer shall hold harmless and indemnify
              Concordia University from any claim in this connection.



3.11          Default
              In the event that the Tenderer shall fail to maintain or keep in force any of the terms and conditions of
              the contract, Concordia University may notify the Tenderer in writing of such failure and demand that
              same be remedied within ten (10) calendar days. Should the Tenderer fail to remedy same within the
              said period, Concordia University reserves the right of the following:
                 Invoke the penalty provisions under this agreement;
                 ask a third party to correct on its behalf, such failure; or
                 terminate the contract

              All expenses incurred by Concordia University in connection with the above will be at the expense of
              the Tenderer and may be deducted from the monthly billing and payment to the Tenderer.




Initials: __________                              Page 14 de 44
       Purchasing Services                                           Tender Document no. UC – 0410027(DD)


3.12          Force majeure
              Neither party shall be considered in default of performance of its obligations under the contract to the
              extent that performance of such obligations is delayed, hindered, or prevented by force majeure. Force
              majeure shall be any cause beyond the control of the parties hereto which they could not reasonably
              have foreseen and guarded against.


3.13          Insolvency
              Concordia University shall have the right to terminate the contract at any time in the event that the
              Tenderer files a petition in bankruptcy, or is adjudicated bankrupt; or if a petition of bankruptcy is
              filed against the Tenderer and not discharged within twenty four (24) hours; or if the Tenderer
              becomes insolvent or makes an assignment for the benefit or its creditors or an arrangement pursuant
              to any bankruptcy law; or if a receiver is appointed for the Tenderer or its business.


3.14          Termination
              Concordia University reserves the right to terminate the contract Concordia University upon the
              transmission of a thirty (30) day written notice at any time during its term. The Tenderer shall have no
              claim for damage, loss of profit, allowance or otherwise, either directly or indirectly, arising out of any
              action taken by Concordia University pursuant to the provisions of this article.


3.15          Insurance
              The Tenderer shall furnish the University with a proof of insurance in the form of certificates
              evidencing the following insurance coverage:
                   a)    Comprehensive General Liability Insurance, including but not limited to products liability,
                         contractual liability and non-owned automobile liability, covering the legal liability of the
                         Tenderer for injuries to or death of persons and/or damage of property of others for limits of
                         not less than two million dollars ($2,000,000.00) per occurrence for bodily injury and
                         property damage. Such insurance shall name Concordia University as a named insured and
                         shall contain Cross Liability coverage and preclude subrogation claims by the insurer
                         against Concordia University.
                   b)    Automobile Liability Insurance covering the legal liability of the Tenderer for injuries to or
                         death of persons and/or damage to property of others for limits of not less than one million
                         dollars ($1,000,000.00) per occurrence.
                   c)    Workmen's Compensation Insurance required under the worker's compensation laws of the
                         Province of Quebec in which the services shall be performed, protecting and covering the
                         Tenderer and its employees in such amounts as required by the applicable law.
                   d)    The insurance policies referred to herein shall contain an endorsement to provide Concordia
                         University with thirty (30) days prior notice in writing of any material changes or
                         cancellations to any of the above policies.


3.16          Presence on Concordia University’s premises
3.16.1        The Tenderer agrees that all persons working for or on its behalf whose duties bring them onto
              Concordia University‘s premises shall be governed by the rules and regulations that are established by
              Concordia University and shall comply with the reasonable directions of Concordia University
              authorized representatives(s).



Initials: __________                              Page 15 de 44
       Purchasing Services                                            Tender Document no. UC – 0410027(DD)


3.16.2        The Tenderer agrees that all persons working for or on its behalf whose duties bring them onto
              Concordia University‘s premises and require them to work on any site and/or construction site shall
              have the proper work permits and safety training in compliance with construction site regulations and
              be subject to inspections by the site security inspector. The Tenderer shall be required to sign all
              Environmental Health and Safety documentation as required by the University (See Annex 6).
3.16.3        The Tenderer shall use employees that are adequately trained and authorized to work on a construction
              site regulated by the Commission de la Construction du Quebec (CCQ). The Tenderer shall use
              unionized employees where required during the project.
3.16.4        The Tenderer shall be responsible for the acts of its employees and representatives while they are on
              Concordia University‘s premises. Accordingly, the Tenderer agrees to take all necessary measures to
              prevent injury and loss to persons or property located on Concordia University‘s premises. The
              Tenderer shall be responsible for all damages to persons or property caused by its employees or
              representatives, either by negligence or willful damage.
3.16.5        The Tenderer shall perform its activities on Concordia University‘s premises in such a way as to cause
              minimal disruption to the activities of Concordia University‘s faculty, students, staff and visitors. The
              Tenderer shall be responsible for all damages to persons or property of any kind however caused by its
              employees or representatives.
3.16.6        The Tenderer shall select one (1) member of its senior staff to act as the liaison for the purpose of the
              Agreement and shall forthwith notify The University of the name, address and telephone and facsimile
              numbers of such staff member.
3.16.7        Parking on Concordia University property by the Tenderer‘s employees shall be governed by the same
              regulations and fees as apply to Concordia University employees.


3.17          Confidentiality
3.17.1        The property and all rights, including all intellectual property rights to reports, specifications, drawings
              and other work accomplished or documentation produced by the Tenderer hereunder shall be vested in
              the University as performance progresses.
3.17.2        The Tenderer as well as its employees, agents and representatives will maintain all information
              pertaining to the University and its business acquired in the course of provision of services hereunder
              and all reports, specifications, drawings and other work accomplished or documentation produced
              hereunder, confidential, and will not disclose or use same for any purposes other than for rendering the
              services hereunder. This provision shall survive any termination or expiry of this agreement.


3.17.3        The Tenderer shall ensure that any information or data (student/alumni member names addresses
              etc…) provided by Concordia University will not be disclosed, in any manner, to third parties (such
              third parties not to include any director, officer, employee or agent of the Tenderer who has a
              legitimate need to know in order to fulfill the Tenderers obligation under this Contract) both during
              and after the term of this Contract. Moreover, the information or data provided by Concordia
              University shall be used by Tenderer solely and exclusively in order to fulfill the Tenderers obligations
              under this Contract. Any breach of this obligation shall be cause for termination of the Contract and
              may expose the Tenderer to penalties provided for under the relevant legislation and to civil claims.


3.18          Intellectual Property
              Any and all designs, drawings, plans, artwork, cartridges, films, videos, CD‘s, software, computer
              programs or other work produced for this Bid and in the completion of the subject matter of this
              Agreement shall be and remain the exclusive property of Concordia University, and the Tenderer

Initials: __________                              Page 16 de 44
       Purchasing Services                                             Tender Document no. UC – 0410027(DD)


              hereby acknowledges and agrees to this condition. Further, Concordia shall have a permanent, non-
              exclusive, royalty-free license to use any programs, software or other proprietary material of the
              Tenderer which is used in the completion of the subject matter of this Agreement.


3.19          Resolution of Dispute
              Any controversy, claim, dispute or disagreement (―Dispute‖) arising out of or relating to this
              Agreement, shall be settled by a process of mediation and arbitration set out in this section 21 and in
              accordance with the rules of the Civil Code of Quebec and the Code of Civil Procedure of Quebec.
              The following procedures shall apply to any Dispute between the parties.
              First, in the event of any Dispute arising from or relating to this Agreement, the parties hereto shall use
              their best efforts to settle the Dispute. To this effect, they shall consult and negotiate with one another
              in good faith and, recognizing their mutual interests, attempt to reach a just and equitable solution
              satisfactory to both parties. If they do not reach such solution within a period of fifteen (15) days,
              then, upon notice by either party to the other the Dispute shall be placed in the hands of a mediator.
              Mediation. Secondly, following the failure of negotiations between the parties, they shall endeavour in
              good faith promptly to identify a single person of experience and good reputation who shall assist the
              parties and attempt to reach a mutually acceptable resolution. Such mediation shall terminate upon the
              decision of the mediator that the parties are not able to reach a common accord, or after thirty (30)
              days, whichever first occurs, unless the mediator reasonably believes that the parties are close to a
              settlement and extends the thirty-day period.
              Arbitration. If mediation fails, or if the parties are unable to agree upon a mediator, then either party
              (the ―Complainant‖) may commence binding arbitration by giving the other party (the ―Respondent‖)
              notice in writing (―Notice of Arbitration‖) setting out in reasonable detail the nature of its claim and
              the relief sought and naming a single person of experience and good reputation to act as the arbitrator.
              Within twenty-one (21) days of receipt of a Notice of Arbitration, the Respondent shall give the
              Complainant notice in writing of its response to the claim, together with a detailed description of any
              cross-demand; a recital of the relief sought; and accepting or refusing the Complainant‘s proposed
              arbitrator.
              In the event that the parties are unable to mutually agree to a neutral arbitrator, the parties or their
              attorneys may seek guidance from the Superior Court of Quebec.
              Consistent with the expedited nature of this arbitration process, each party will, upon the written
              request of the other party, promptly provide the other with copies of documents relevant to the issues
              raised by any claim or cross-demand on which the producing party may rely in support of or in
              opposition to any claim or defence. Any dispute regarding discovery, or the relevance or scope
              thereof, shall be determined by the arbitrator, and its determination shall be conclusive. All discovery
              shall be completed within sixty (60) days following the appointment of the arbitrator, unless the
              arbitrator provides further time to the parties.
              The arbitration proceedings shall take place in Montréal.
              The available relief shall include damages and other relief to the extent permitted under the laws in
              force in Quebec and under the terms of this Agreement.
              The final decision of the arbitrator (the ―Award‖) shall be issued within three (3) months of the
              termination of the arbitration proceedings.
              Each party to the proceedings shall pay its own costs in connection with the proceedings, and the
              parties shall share equally the costs of the proceedings, including the fees of the arbitrator, except that
              the arbitrator may award costs, including attorneys‘ fees, to the prevailing party.



Initials: __________                               Page 17 de 44
       Purchasing Services                                           Tender Document no. UC – 0410027(DD)


3.20          Patents
              The Vendor agrees to indemnify and hold Concordia University harmless from and against all claims,
              suits, and damages suffered by Concordia University arising from allegations that the proposed cabling
              system or any part there of constitutes an infringement of any patent, if the Vendor is notified promptly
              of the assertion of any such allegation and if the Vendor is given authority, to defend the same. Upon
              notification of an infringement claim, the Tenderer reserves to do any of the following, at no cost to
              Concordia University:
                     a)     Procure for Concordia University the right to continue using the installed cabling system
                            and support equipment; or
                     b)     Modify the cabling system and support equipment so that it becomes non-infringing
                            without reducing its performance; or
                     c)     Replace the same with non-infringing cabling system and support equipment equal or
                            superior in performance, in which case all provisions of this agreement shall apply to the
                            replacing software and hardware.
3.21          Notices
              Any notice or other communication required or permitted to be given under this Agreement shall be in
              writing and shall be delivered in person, transmitted by telecopy or similar means of recorded
              electronic communication or sent by registered mail to the attention of Mr. Daniel Dorval, Senior
              Project Buyer, Purchasing Services, Concordia University, 1550 de Maisonneuve Blvd, West, Suite
              GM 1003, Montreal, Quebec, H3G 1N2.

3.22          Assignment of contract
              The Tenderer without the prior written consent of Concordia University shall not assign the contract.

3.23          Sub-contracting
              Neither the whole nor any part of the work may be sub-contracted by the Tenderer without the prior
              written consent of Concordia University.

3.24          Waiver
              Any waiver of a condition or obligation hereunder by either party shall only be binding if made in
              writing with thirty (30) days prior notice and shall not constitute a waiver of any other condition or
              obligation for the benefit of the party so waiving, whether past or future.

3.25          Successors and assigns
              The final agreement shall be considered valid and will remain in effect until the conclusion of the
              current term by any successor company to the Tenderer. Concordia University y reserves the right to
              review the agreement) in the event of a successor company and exercise its options of termination.

3.26          Publicity
              Neither party shall use the name of the other party in publicity, releases or advertising without the prior
              written consent of the other party.

3.27          Governing laws
              The contract shall be governed and interpreted according to the laws of the Province of Quebec.

3.28          Language
              The parties confirm that all documents and notices in connection to this agreement are drawn in
              English.



Initials: __________                              Page 18 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)


4.0          PROJECT TECHNICAL REQUIREMENTS

4.1          General
4.1.1        The installation of a NORDX/CDT structured cabling system for the newly renovated Drummond
             Science building on the Loyola campus. The structured cabling system is comprised of Category 6
             UTP copper cable, multimode fiber optic and singlemode fiber optic cable. This project includes the
             provisioning of ancillary equipment for the telecommunications closets such as equipment racks, rack
             cable management hardware, cable trays.
4.1.2        The summary description given in this article gives only an outline of the work to be carried out. It is
             the responsibility of the Tenderer to take care to carefully consult the attached documentation in its
             entirety and/or seek clarification in order to determine the scope of the work
4.1.3        All equipment and materials shall be new, latest version at time of bid, and shall conform to applicable
             UL, CSA, or ANSI provisions. Evidence of unauthorized re-manufactured, or ―B‖ stock equipment on
             the project site will be deemed evidence of Failure to Perform the Work. Take care during installation
             to prevent scratches, dents, chips or disfiguration and correct minor scratches with manufacturer‘s
             approved finish.
4.1.4        Regardless of the length or completeness of the descriptive paragraphs contained in this document,
             each item or device shall meet published manufacturer‘s specifications.
4.1.5        This document generally lists major equipment, but does not include items generally categorized as
             miscellaneous installation material, supplies, and custom assemblies. The Tenderer shall furnish and
             install all required equipment, devices and other materials, even though not specifically mentioned
             herein, which are necessary for the proper operation of each system so that each system shall perform
             in accordance with the functional requirements.
4.2          Reference Standards
             This document is based on national and international codes and standards notably:
               TIA/EIA-568-B.1: Commercial Building Telecommunications Cabling Standard Part 1 : General
                Requirements
                Including :
                Addendum 1 – Minimum 4-Pair UTP and 4-Pair ScTP Patch Cable Bend
                Radius
               TIA/EIA-568-B.2: Commercial Building Telecommunications Cabling Standard Part 2 : Balanced
                Twisted-Pair Cabling Components
                Including :
                Addendum 1 – Transmission Performance Specifications for 4-pair 100Ω
                Category 6 Cabling
                Addendum 2
                Addendum 3 – Additional Considerations for Insertion Loss and return
                Loss Pass/Fail Determination
               TIA/EIA-568-B.3: Optical Cabling Components Standard
               TIA/EIA-526-7: Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant
               TIA/EIA-598-B: Optical Cable Color Coding
               TIA/EIA-606-A: Administration Standard for Commercial Telecommunications Infrastructure
               TIA/EIA-607: Commercial Building Grounding and Bonding Requirements for
                Telecommunications
               TIA/EIA-526-7: Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant
               EIA RS-310-C: Racks, Panels and Associated Equipment
               Code de l‘électricité du Québec

Initials: __________                            Page 19 de 44
      Purchasing Services                                            Tender Document no. UC – 0410027(DD)


                Code national du bâtiment
4.3          Inclusions
4.3.1        Engineering, fabrication, installation, inspection, testing, instruction, and warranties of the structured
             cabling system and associated equipment as described in this Request for Proposal, to provide
             complete and fully functional systems.
4.3.2        Supply of all labour, programming, equipment, materials, cabling, hardware, tools, transportation
             services, coordination, etc., necessary to complete the installation of the structured cabling systems and
             to meet the functional requirements described herein.
4.3.3        Each of the following:
                 a) Verification of dimensions and conditions at the job site.
                 b) Installation in accordance with the manufacturer's recommendations and project requirements.
                 c) Documented system tests and adjustments, written report, demonstration for approval, final
                      adjustments, and documentation.
                 d) Instruction of owner designated personnel.
                 e) Preparation of operating and maintenance manuals (as applicable).
                 f) Maintenance services and warranty documentation.

4.3.4        Provide for mounting or attachment of any equipment to ceilings, walls, floors, or other locations as
             described in this document and supplemental information documents provided with the tender
             package.
4.3.5        Supply accessories and minor equipment needed for a complete system, even if not specifically
             mentioned in these documents, without claim for additional payment.
4.3.6        Keeping the worksite clean at all times and providing the necessary containers for the removal of all
             waste generated off site. The location of such containers are to be coordinated with the construction
             general contractor.
4.3.7        Coordinate work with a General Contractor, Project representative and other trades as required. As
             part of this coordination include the following:

             Carefully check and verify all pertinent dimensions and sizes and the appropriateness of all structure
             supporting the equipment before proceeding with any work. Examine all pertinent construction and
             work of other contractors at the job site which may affect the work to insure a timely and safe
             installation.

             Notify the Project representative in writing of any difficulties that may prevent proper coordination of
             the work with the work of other contractors. Failure to do so constitutes acceptance of construction as
             suitable for installation.


4.3.8        Workshop Drawings

             Before the beginning of the work, the Tenderer must submit the workshop drawings listed in this
             section.

             No work can begin without prior approval of the relevant workshop drawing.




Initials: __________                             Page 20 de 44
      Purchasing Services                                            Tender Document no. UC – 0410027(DD)


             All workshop drawings must be presented on paper 8 1/2" X 11" or 11" X 17". Two copies of each
             workshop drawing are to be provided prior to approval. The first page of the workshop drawings must
             be used to identify the Tenderer and the project.

             All workshop drawings must be submitted at the same time.

             The workshop drawings must provide all the relevant information for the work or the product which
             they describe. If information un-related to the project is present on the drawings, the Tenderer must
             precisely annotate the drawing to distinguish the information which he wants to convey. These
             annotations must be reproducible on a photocopier.

             The Tenderer must answer all questions, supplement his workshop drawings, submit a different
             product or re-submit a drawing, according to the indications which will be given to him on the
             workshop drawings with accompanying notes until all the workshop drawings are approved.

             Once all of the workshop drawings have been approved, the Tenderer must produce five copies and
             keep the originals to serve as part of the ―as-built‖ documentation (section 4.6.1). The copies must be
             given to the designated representative of the University. Also, the Tenderer must at all times keep one
             copy on the building site and another copy at his offices.

             The approval of a workshop drawing for a product or work does not release the Tenderer of its
             responsibility vis-à-vis this product or work. It falls to the Tenderer to ensure for each product of its
             compliance, availability, compatibility, and performance with the plans and estimates.

             To provide workshop drawings for all products required by this project;
4.3.9        Installation
4.3.10       Coordinate work with other trades to avoid causing delays in the renovation schedule.
4.3.11       Mount equipment and enclosures plumb and square and affixed to floor or walls as appropriate.
             Permanently installed equipment is to be firmly and safely held in place.


4.4          DS Building Requirements
4.4.1        Please refer to the enclosed CD ROM for all construction plans related to this project.

4.5          Detailed Technical Requirements
4.5.1        General Requirements

             A NORDX/CDT Structured Cabling System:

             The IBDN cabling system selected to be used in the new Drummond Science Complex shall be based
             on the IBDN System 4800LX technology.

             The IBDN cabling system shall be based on a physical star cabling topology that is defined in
             accordance with and supported by NORDX/CDT‘s certification, as specified herein.

             The proposed cabling system shall be applications-independent and network technology-neutral.


Initials: __________                             Page 21 de 44
    Purchasing Services                                           Tender Document no. UC – 0410027(DD)


4.5.2       End to End System Requirements

            To ensure all performance requirements are met the IBDN System 4800LX and IBDN Optical Fiber
            System shall be defined, designed and installed as an end-to-end system. All components of the offered
            system shall be from the IBDN product portfolio. A structured cabling system is understood to be
            made up of a number of interdependent subsystems, including:

            The Work Area subsystem, where station equipment is connected to the Telecommunications
            Outlet/Connector or the Multi-User Telecommunications Outlet Assembly (MUTOA) with modular
            cords (the cords may be equipped with baluns, media filters and/or adapters, if required).

            The Horizontal Cabling subsystem.

            The Horizontal Cross-connect subsystem, which is located in the telecommunications closet (TC).

            The Backbone Cabling subsystem, which provides the in-building cabling to link the Horizontal Cross-
            connect to the Main/Intermediate Cross-connect.

            The Main/Intermediate Cross-connect subsystem, which is generally located in the telecommunications
            room (TR).

            The Campus subsystem, which provides the inter-building cabling to link the Main Cross-connect in
            the central campus building to the Intermediate Cross-connect(s) in the satellite building(s) on campus.


4.5.3       Work Areas

            A minimum of two (2) cables for data service to be delivered to each wall plate (or equivalent) unless
            otherwise indicated

            Provide modular cable of standard lengths (70% of total - 10‘, 15% of total - 15‘ and 10 % of total -
            25‘) for the connection of workstation network devices to the wall plates (or equivalent workstation
            area connectors).

            Note that the     B.T.M          symbol appearing in selected classrooms on the electrical drawings
                                             indicate a requirement for six (6) Category 6 UTP cables that are
            usually indicated by a black triangle. Two cables are to be mounted in the ceiling near the projection
            equipment. Two cables are to be mounted in the BTM enclosure indicated by the above symbol. Two
            cables to be mounted at the teacher‘s desk. Exact locations will be provided prior to the start of the
            project. See ―Electricite Services Auxiliaires‖ drawings.

            The presence of the symbol indicating a requirement for fiber optic cable in a work area implies a 50
            multimode fiber optic cable.

            The Tenderer is required to include in the design, ―spare‖ Category 6 cable for each zone as per TIA
            norms. These cables are to have the appropriate connectors installed and are to be left coiled on J-
            Hooks in the ceiling space.




Initials: __________                           Page 22 de 44
    Purchasing Services                                              Tender Document no. UC – 0410027(DD)


4.5.4       Telecommunications Closets:

            Design of TC layout is to be included in the proposal.

            Provide and install two (2) 19‖ H-Frames to support network devices and any cable patch field
            equipment (if required) in each.

            Vertical cable trays separating H-Frames must be a minimum of 10‖ in width. Vertical cable trays on
            outside of rack equipment must be a minimum of 5‖ in width.

            Provide and install power bars, horizontal cable management on H-Frames and any other H-Frame
            accessories deemed necessary. .

            Multi-pair copper cable to support Analog copper terminated on appropriately pinned patch panels to
            allow use of standard modular cords for patching.

            Provide the necessary modular cords (or equivalent) for use within the TC‘s to connect active network
            equipment to horizontal components plus an additional 10% of each type and length.

            Fiber optic cable to be terminated using SC type connectors.


4.5.5       Telecommunications Room:

            Design of TR layout is to be included in the proposal.

            Provide and install three (3) 19‖ H-Frames to support network devices and any cable patch field
            equipment (if required) in each.

            Vertical cable trays separating H-Frames must be a minimum of 10‖ in width. Vertical cable trays on
            outside of rack equipment must be a minimum of 5‖ in width.

            Provide and install power bars, horizontal cable management on H-Frames and any other H-Frame
            accessories deemed necessary. .

            Multi-pair copper cable to support Analog applications to be using cross-connect system mounted on
            wall (Refer to Annex 2 for suggested layout).

            Provide the necessary modular cords to connect active network equipment to horizontal and vertical
            components plus an additional 10% of each type and length.

            Fiber optic cable to be terminated using SC type connectors unless specified otherwise.
4.5.6       Labelling Schema

            Propose an appropriate labelling schema for the cabling system given the requirements listed above.




Initials: __________                           Page 23 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)


4.5.7        Miscellaneous Equipment and Hardware

             Flexible PVC yellow tube, FT4 rated, 38 mm in diameter to identify and protect fiber optic cable.

             Provide twenty (40) 3 meter 50 multimode fiber interconnect cables (SC/SC connectors).

             Provide twenty (40) 3 meter 50 multimode fiber interconnect cables (LC/SC connectors).

             Provide twenty (20) 2 meter 9 singlemode fiber interconnect cables (SC/SC connectors).

             Appropriate cable labelling system Samples to be reviewed with IITS representatives prior to start of
             project.

             All hardware required for the mounting and installation of equipment to be supplied by Tenderer.

             All labelling for identifying plugs, patch panels, conduit, etc to be furnished by Tenderer.

             All material required for grounding to be furnished by Tenderer.

             All material required for the completion of the work outlined regardless of whether or not it is
             specifically described in this document is to be furnished by Tenderer


4.6          Submittals
             Contract Close-out Submittals – the following is required to be submitted as a condition of final
             acceptance:
4.6.1        ―As built‖ Drawings:

             The Tenderer must produce a version of "as built" drawings. The drawings must be submitted at the
             latest 2 weeks after the end of work, each time that a floor is completed. The drawings involving
             several floors must be submitted along with the drawings for last delivered floor.

             The drawings must be in AutoCAD format, version 2000 or later.

             The Tenderer will carry out and correct the drawings until they are accepted by the representative of
             the University with respect to exactness of the contents and with the quality of the presentation of the
             information.
4.6.2        Documentation

             A testing logbook is to be prepared and must be submitted to the University‘s representative no later
             than two weeks after the each floor has been completed.

             During the process of approving of the logbooks, only one copy to be submitted for approval. The
             representative of the University will perform an analysis and will then return it with comments to the
             Tenderer, who will then carry out any corrective measures requested and then will resubmit the
             logbook for approval.


Initials: __________                            Page 24 de 44
      Purchasing Services                                          Tender Document no. UC – 0410027(DD)


             Once the final logbook has been approved, the tenderer is to produce five (5) identical copies and to
             give them to the representative of the University. Documentation must be clearly identified with the
             description of the project, the name and the co-ordinates of the Tenderer, the number of volume and
             the contents, etc.

             Once work in the telecommunications closets and room is complete, the tenderer is to provide digital
             photographs of including an overall view of closet or room, each rack (front and back), each wall with
             cables, grounding. The photographs must be in JPG or JPEG format and must have a minimal
             resolution of 960 X 1200 pixels.

             Each book, drawing, CD-Rom, etc included in the handbooks must be clearly identified individually
             with the project and the handbook from where it comes.

             The handbooks must contain the following documents, in the notched formats:
                a) approved workshop drawings                       [X] hard copy    [ ] electronic
                b) reports/ratios of tests of the cables            [ ] hard copy    [ ] electronic
                c) certificate of guarantee of the manufacturer     [X] hard copy    [ ] electronic
                d) drawings "as built"                              [X] hard copy    [X] electronic
                e) documentations and handbooks
                    of the manufacturers of the products            [X] hard copy    [ ] electronic
                f) digital photographs of the wall cupboards
                    and rooms                                       [ ] hard copy    [X] electronic

4.7          Delivery, Storage and Handling
4.7.1        Bear costs of all shipping to the site, and of all unusual storage requirements. Make appropriate
             arrangements, and coordinate with authorized personnel at the site, for the proper acceptance,
             handling, protection, and storage of equipment so delivered.
4.7.2        Check, and if necessary, clean all systems, equipment, devices and components included in the work
             after acceptance and completion of the work of all other trades.
4.7.3        Protect all materials and equipment to prevent the entry or adhesion of concrete, plaster, drywall dust,
             unintended paint, or other damaging debris of materials.


4.8          Acceptance
4.8.1        Acceptance testing will include the successful demonstration by the Tenderer the operation of each
             major system and any other components deemed necessary. The Tenderer shall be responsible for this
             testing and shall provide required test equipment. The Tenderer must provide technicians familiar with
             installation, and must be available for the entire testing period to perform the tests, adjustments, and
             final modifications. The Tenderer shall furnish tools and material required to make any necessary
             repairs, corrections, or adjustments.
4.8.2        In the event there is a need for further adjustment or work becomes evident during equalization or
             acceptance testing, the Tenderer will continue the work while the system is in acceptance at no
             addition to the contract price.
4.8.3        As a condition of final acceptance, the Tenderer shall provide documented proof that the system is
             functioning within the required specifications by providing the documentation as specified herein.
4.8.4        The Tenderer shall keep a log and track the progress of all deficiencies during this phase of the
             project.

Initials: __________                            Page 25 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)



5.0          Vendor Questionnaire

             Questions are to be answered in a separate annex to your proposal.
5.1          General
5.1.1        How long have you been a provider of NORDX/CDT IBDN Cabling Systems? Response:
5.1.2        What is the total number of employees of your firm? Response:
5.1.3        Briefly describe your relationship with NORDX/CDT, and how it would benefit our institution.
             Response:
5.1.4        In how many Universities have you installed a similar system? Response:
5.1.5        Provide 3 references of institutions where you have installed an NORDX/CDT IBDN Cabling System.
             List must include:
                                  Institution, Contact and phone number
                                  Date of Installation
                                  Equipment installed

5.2          Financial Information
5.2.1        The financial responsibility is assumed by
             (indicate the name of entity)


5.2.2        Annual sales volume in dollars for each of the last three years:
                2002           ____________
                2003           ____________
                2004           ____________

             Please attach the most recent certified / audited financial or income statement the years mentioned
             above

5.3          Proposed System
5.3.1        Provide a description of the proposed system. Include diagrams if desired. Response:
5.4          System Architecture
5.4.1        Provide a diagram of the proposed system architecture. Response:

5.4.2        Describe how, once the installed cabling system is certified, you will assist Concordia University in
             maintaining this certification during network growth. Response:
5.5          System/Station features


5.5.1        Describe in detail the process that is required to maintain a certified NORDX/CDT Cabling System,
             especially with regards to change control / system growth. Response:
Add Item 5.5.2


Initials: __________                            Page 26 de 44
      Purchasing Services                                         Tender Document no. UC – 0410027(DD)


5.5.2        Describe in detail the performance characteristics of the 50m multimode fiber optic cabling when used
             with SC wall connectors and SC/LC patch cords for SAN and/or Gigabit ethernet environments.
             Clearly specify supported data rates and distance limitations for SAN networks and/or Gigabit ethernet
             networks.


5.6          Labelling Schema:
5.6.1        Describe the proposed labelling schema. Response:

5.6.2        Describe how the proposed labelling schema will be implemented. Response:


5.7          Training:
5.7.1        For each product application proposed, provide a description of the training the vendor will provide.
             Response:




Initials: __________                            Page 27 de 44
      Purchasing Services                                          Tender Document no. UC – 0410027(DD)


6.0          FORM OF TENDER

6.1          Agreement
             The undersigned Tenderer has examined and understood the Request for Proposal Document No. UC
             – 0410027(DD) entitled “Supply and Installation of a NORDX/CDT IBDN Cabling System for
             the New Drummond Science Building”.

             The undersigned Tenderer hereby agrees to provide according to the quality and manner specified
             herewith, and discharge all obligations and assume all liabilities imposed by the Request for Proposal
             Document, which form is intended for the sole purpose of comparison.


6.2          Signing authority
             The Tenderer shall provide the University with a certified resolution, signed under corporate seal, of
             the Board of Directors of the Tenderer authorizing the agent(s) whose names appear below to sign this
             Form of Tender on behalf of the Tenderer.




                Date:                                                               Signed under seal



                ________________________                      __________________________
                Name of the Company                            Name of the Company

                _________________________                     ______________________________
                Name (please print)                            Name (please print)

                ______________________________                 ______________________________
                Title                                          Title

                ______________________________                ______________________________
                Signature                                     Signature



                With its Registered Offices located in the City of ___________, Province of ___________.




Initials: __________                            Page 28 de 44
      Purchasing Services                                           Tender Document No. UC – 0410027(DD)



6.3           Description of the Price Schedule Line items
              The following is a description of what is required to be taken into consideration when providing your
              quotes in the price schedule section:

6.3.1         A price schedule for the horizontal cabling showing all material and labour for the installation,
              termination, labelling and final certification from and including the wall plate (or equivalent) in the
              work area to and including the cross-connect or patch cords in the telecommunications closet (referred
              to as TC herewith). Please present the information in such a way such that all indicated runs for each
              telecommunications closet can be accounted for and validated in the submitted proposal document.

6.3.2         A price schedule for the vertical cabling – Data (inter-telecommunication closet itemizing all material
              and labour for the installation, termination, labelling and final certification of all components not
              described in the previous paragraphs.

6.3.3         A price schedule for the vertical cabling – Voice (inter-telecommunication closet itemizing all material
              and labour for the installation, termination, labelling and final certification of all components not
              described in the previous paragraphs.

6.3.4         A price schedule for inter-building - data network cabling itemizing all material and labour for the
              installation, termination, labelling and final certification of all components not described in the
              previous paragraphs.

6.3.5         A price schedule for inter-building - voice network cabling itemizing all material and labour for the
              installation, termination, labelling and final certification of all components not described in the
              previous paragraphs.

6.3.6         A price schedule of all material and labour for the items to be installed in the TCs that have not been
              described in the paragraphs above. This may include such components as cable trays or ladders, racks,
              cable management hardware, etc.

6.3.7         A price schedule for any charges for cabling infrastructure/topology design support required to
              complete this contract. Please identify hourly rates for technician if different than above.

6.3.8         A separate schedule for any charges for non-cabling related charges that may apply – please clearly
              indicate this in your proposal.




                                                   Page 29 de 44
      Purchasing Services                                           Tender Document no. UC – 0410027(DD)



6.4          Price Schedule
             Please provide a detailed spreadsheet to support the values entered below. Discounts should be
             applied to the column provided in this spreadsheet.

             Total Cost of Horizontal Cabling                                                       $
             Total Cost of Vertical Cabling (Data)                                                  $
             Total Cost of Vertical Cabling (Analog)                                                $
             Total Cost of Inter-building Cabling (Data)                                            $
             Total Cost of Inter-building Cabling (Analog)                                          $
             Total Cost of Telecommunication Closets                                                $
             Total Cost for non-cabling related charges                                             $


             TOTAL CONTRACT Price                                                   ___________     $

6.5          Optional Items
             Please provide a unit quote for the following items:

6.5.1        ―Ad Hoc‖ Runs
             Please note that all ―ad-hoc‖ runs include

             ―Ad-Hoc‖ Simplex Run (Cat 6)                                           ___________$ / run
             ―Ad-Hoc‖ Duplex Run (Cat 6)                                            ___________$ / run
             ―Ad-Hoc‖ Quadruplex Run (Cat 6)                                        ___________$ / run
             ―Ad-Hoc‖ Sixplex Run (Cat 6)                                           ___________$ / run
             ―Ad-Hoc‖ Simplex Run (50 multimode fiber optic)                       ___________$ / run
             ―Ad-Hoc‖ Duplex Run (50 multimode fiber optic)                        ___________$ / run
             ―Ad-Hoc‖ Simplex Run (9 singlemode fiber optic)                       ___________$ / run
             ―Ad-Hoc‖ Duplex Run (9 singlemode fiber optic)                        ___________$ / run




Initials: __________                            Page 30 de 44
      Purchasing Services                                         Tender Document no. UC – 0410027(DD)




6.6          Addenda


             It is requested that the Tenderer enclose a copy of all signed addenda which were received by either
             email or facsimile within the framework of this tender submission.
             Also, the Tenderer shall complete the following table by transcribing the number of the addenda, the
             date issued, the name(s) of the authorized officer(s), in printed letters, and affixing their initials.


TABLE OF ADDENDA RECEIVED


                                NAME ( S ) OF COMPANY                   INITIALS OF COMPANY OFFICER
                                           OFFICER ( S )                          (S)
NUMBER        DATE
                                (PRINTED LETTERS)




Initials: __________                           Page 31 de 44
    Purchasing Services                                 Tender Document no. UC – 0410027(DD)




                                            Annex 1

                                    General Project Schedule




See on CD ROM – filename:   DS general building schedule.pdf




Initials: __________                   Page 32 de 44
    Purchasing Services                                Tender Document no. UC – 0410027(DD)




                                           Annex 2

                                 Vertical Cabling Requirements




See on CD ROM – filename:   Annex 2_Vertical Cable Requirements.vsd




Initials: __________                   Page 33 de 44
    Purchasing Services                               Tender Document no. UC – 0410027(DD)




                                           Annex 3

                              Typical Telecom Closet Rack Layout




See on CD ROM – filename:   Annex 3_Telecom Closet Rack Layout.vsd




Initials: __________                  Page 34 de 44
    Purchasing Services                               Tender Document no. UC – 0410027(DD)




                                          Annex 4

                                 Telecom Room Rack Layout




See on CD ROM – filename:   Annex 4_Telecom Room Rack Layout.vsd




Initials: __________                  Page 35 de 44
    Purchasing Services                               Tender Document no. UC – 0410027(DD)




                                          Annex 5

                                     Analog Cable Layout




See on CD ROM – filename:   Annex 5_Telecom Room Analog Cable Layout.vsd




Initials: __________                  Page 36 de 44
    Purchasing Services                            Tender Document no. UC – 0410027(DD)




                                       Annex 6

     Environmental health and safety RULES FOR CONTRACTORS WORKING ON CONCORDIA
                                                PREMISES




Initials: __________               Page 37 de 44
     Purchasing Services                                             Tender Document no. UC – 0410027(DD)


          Environmental Health and Safety Rules for Contractors Working on Concordia Premises

It is the responsibility of the person designated by Concordia University as Project Coordinator/Manager to
               ensure that these rules are included as part of all agreements or contracts involving inspection,
               maintenance, construction, installations or custodial work carried out within Concordia
               buildings, premises and grounds.

These Rules will apply to all contractors working on or in Concordia Premises and will form an integral part
            of all such contract agreements.

A.1.0         CONTRACT AGREEMENTS

A.1.1.        In the case of blanket orders or other agreements emanating from Purchasing Services, these Rules
              shall be included in the relevant Purchasing Services documentation;

A.1.2.        In the case of public bids, these Rules shall be included in the bid documentation and must be signed
              and returned by the Tenderers in order for a bid to be considered;

A.1.3.        In the case of invited bids, these Rules shall be included in the bid documentation and must be signed
              and returned by the Tenderers in order for a bid to be considered;

A.1.4.        Where no bidding process nor Purchasing Services process is involved, the contractor must sign and
              return these Rules to the Project Coordinator/Manager before commencing work.

A.2.0         CONTRACTOR SUBMISSION REQUIREMENTS

The Contractor is responsible for the competence, solvability and contents of the submission of each of his/her sub-
             contractors and of informing each and every one of them of their obligations and responsibilities
             pursuant to this agreement.

Contractors are responsible for submitting the following documentation prior to commencement of the work
             and maintaining this information current for ongoing projects:

A.2.1         Proof of liability insurance in accordance with the requirements of the Office of the Treasurer;

A.2.2         Current CSST number and rating;

A.2.3         As appropriate, proof of health and safety training and other necessary certification relative to the
              work to be done (e.g. construction safety course, asbestos training etc.). The Concordia Project
              Coordinator/Manager will specify the requirements based on the work and risk assessment;

A.2.4         Copy of contractor‘s Health and Safety program (or prevention programme);

A.2.5         List of all hazardous materials to be used on site together with their material safety data sheets
              (MSDS).

A.3.0         CONTRACTOR RESPONSIBILITIES

A.3.1         Access to Concordia Buildings/Premises




Initials: __________                              Page 38 de 44
     Purchasing Services                                             Tender Document no. UC – 0410027(DD)


A.3.1.1       Except by special arrangement with the Director of Security or his designate, all contractors and their
              sub-contractors must present themselves daily to the Security Desk on the campus where they will be
              working: the Hall (H) Building for SGW Campus and the (AD) Building for Loyola;

A.3.1.2       There they will sign in, present their identification and be issued a contractor identification badge;

A.3.1.3       In order to be issued a badge they must provide Security with the following information: location(s)
              where the work will be carried out, the name of Concordia‘s Project Coordinator/Manager, list of the
              hazardous materials to be used during the project, any interruption or bypassing of fire protection
              systems, hot work permits and any other information judged to be pertinent;

A.3.1.4       The identification badge must be worn in full view at all times. The badge must be returned to the
              Security desk at the end of each work period.

A.3.2         Project Management

Contractors have the complete responsibility of their work. They must provide effective direction and
            supervision over all aspects of the work carried out.

They are solely responsible for the types of work, methods, techniques, sequences, work processes for all of
             the parties employed in the fulfillment of the contract including planning, erection, operation
             and removal of structures and temporary installations. If the legislation or the contract
             documents require, and in all cases where temporary installations and their construction require
             the professional services of an engineer to satisfy the University’s safety requirements, the
             contractor is responsible to engage and pay for these services.



A.4.0     SAFETY

Contractors are responsible for working safely while on Concordia premises. Contractors are responsible for:

A.4.1     Ensuring that all their employees are covered by CSST;

A.4.2     Providing, maintaining and paying for appropriate liability insurance;

A.4.3         Conducting the work in strict accordance with the current Quebec Act Respecting Occupational Health
              and Safety and applicable regulations;

A.4.4         Providing certification for all trades according to la Commission de la construction du Quebec (CCQ);

A.4.5         As appropriate, participating in the pre-start risk assessment or annual safety review;

A.4.6         Ensuring their employees and subcontractors are instructed in the known risks, e.g. potential fire,
              explosion or toxic release hazards related to the work and procedures to be employed;

A.4.7         Advising their employees and subcontractors of the unique hazards the contractor‘s work presents to
              Concordia‘s activities;

A.4.8         Ensuring their employees and subcontractors are informed and follow Concordia safety policies and
              procedures e.g. the hot work permit process, lockout tag-out procedure, fire protection interruption;



Initials: __________                              Page 39 de 44
    Purchasing Services                                           Tender Document no. UC – 0410027(DD)


A.4.9       As appropriate, training their employees or subcontractors in the applicable provisions of
            Concordia‘s Emergency Plan, including evacuation procedures;

A.4.10      Informing their employees and subcontractors of their responsibility to report, within 24 hours of their
            occurrence or discovery to the Project Coordinator/Manager, all injuries, illness, or any hazards found
            during the work;

A.4.11      Providing prescribed personal protective equipment and any other equipment necessary for the work
            that meets or exceeds all applicable safety standards and criteria.




A.5.0       CONTRACTOR SAFETY RULES
            CONTRACTOR & SUBCONTRACTOR EMPLOYEES MUST:

A.5.1       Use appropriate fall protection when working at heights above 2 meters, including working on an
            aerial work platform. The fall protection must conform to CSST Construction Safety Code and must
            be adequately secured to a fixed support or to a lifeline;

A.5.2       Use any other Personal Protective Equipment (PPE) that is required for the job by either legal
            regulation or standard practices.

CONTRACTOR & SUBCONTRACTOR EMPLOYEES MUST NOT:

A.5.3       Use any intoxicants or illegal drugs;

A.5.4       Smoke in Concordia buildings/premises;

A.5.5       Engage in any fighting or horseplay.

A.5.6       Engage in any unseemly behaviour.

Work Practices
CONTRACTORS & SUBCONTRACTORS MUST:

A.5.7       Designate a competent person on site to act as Supervisor and to be responsible for safety. Inform the
            Project Coordinator/Manager of the applicable person, including 24 hours contact number;

A.5.8       Obtain all necessary documentation, including construction permits if required, licenses notices and
            certificates for the completion of the work;

A.5.9       Comply with and ensure that all employees and sub-contractors comply with all federal, provincial and
            municipal legislation, regulations, codes, decrees, collective agreements, notices and standards relating
            to construction and maintenance and provide proof of compliance;

A.5.10      Park personal vehicles in designated parking areas;

A.5.11      Sign in and out prior to starting or leaving for the day, as required;

A.5.12      Wear and/or use protective safety equipment or devices as required;


Initials: __________                           Page 40 de 44
    Purchasing Services                                           Tender Document no. UC – 0410027(DD)




A.5.13      Comply with all aspects of Hazardous Materials Regulations (WHMIS), employee training,
            labels, and MSDS;

A.5.14      Prior to project commencement, advise the Project Coordinator/Manager of any hazardous material to
            be brought on site; receive approval for and provide a copy of the MSDS for this material before it is
            brought on site; ensure all labeling (Tenderer/workplace) is properly affixed & any decanting of
            materials is done before bringing the material onsite;

A.5.15      Be familiar with the locations of all emergency exits and emergency & fire suppression
            equipment on site;

A.5.16      Maintain work and storage areas in a clean, neat and orderly fashion and keep it clear of
            garbage and accumulated debris;

A.5.17      Secure and lock up all tools and construction equipment nightly;

A.5.18      Consume food and beverages only in designated area;

A.5.19      Rope off or block off work areas and post signs (when applicable);

A.5.20      Maintain the functioning of all fire protection systems during nights and weekends. During normal
            working hours, the systems must remain operable except when the execution of the work may trigger
            false alarms;

A.5.21      In occupied areas, maintain the function of fire protection systems at all times except for the short
            periods where they must be disabled to complete the work. These periods must be planned in advance
            with the Project Coordinator/Manager in conformity with the provisions outlined in the following
            paragraphs;

A.5.22      Obtain from the Project Coordinator/Manager, twenty-four hours in advance, “Hot Work Permits”
            prior to conducting any hot work activities, e.g. welding, cutting, burning, heavy grinding. A new Hot
            Work Permit is required for each shift. Part 2 of the permit shall be posted and Part 1 shall be
            immediately forwarded to the Project Coordinator/Manager. A dedicated person must be provided to
            maintain a fire watch during any hot work, with the appropriate fire extinguisher readily available.
            The fire watch shall be maintained through breaks and 60 minutes (1 hour) after the work is
            completed. Periodic monitoring shall be conducted for 4 hours after the work is completed;

A.5.23      Obtain from the Project Coordinator/Manager, twenty-four hours in advance an “Interruption of
            Fire-Protection Systems Permit” prior to interrupting any fire-protection system. A new ―Permit‖ is
            required for each shift. Part 2 of the permit shall be posted and Part 1 shall be immediately forwarded
            to the Project Coordinator;

A.5.24      Use Lockout/Tag-out procedures whenever servicing or working on any powered equipment;

A.5.25      Trenching and shoring work is to be conducted in conformance with relevant regulations;

A.5.26      Obtain approval from Project Coordinator/Manager prior to entering any confined space (tanks,
            vessels, ovens, ducts, etc.) and complete the permit entry process. Provide all necessary equipment to
            conduct the confined space entry according to entry procedure;



Initials: __________                           Page 41 de 44
       Purchasing Services                                          Tender Document no. UC – 0410027(DD)


A.5.27        Obtain approval from Project Coordinator/Manager to use facility gases, electric or other utility
              services. All attachments and connections necessary for the work will be done with the approval of the
              Project Coordinator/Manager and any cost will be assumed by the contractor;

A.5.28        Obtain approval from Project Coordinator/Manager to turn any valve, throw any switch, break into any
              duct or piping, or entering any location where asbestos containing materials may be present;

A.5.29        Use safe and approved tools and equipment;

A.5.30        Obtain written approval from Project Coordinator/Manager to borrow or use any tools or equipment;

A.5.31        Obtain approval to remove any safety guards;

A.5.32        Use explosion proof equipment in any designated or potentially explosive areas;

A.5.33        Unless given instructions to the contrary, close all openings and replace all structures in the same form
              and dimensions and using the same materials as existed prior to the work being carried out.

CONTRACTOR & SUBCONTRACTOR EMPLOYEES MUST NOT:

Damage or compromise the integrity of any of the existing elements to be conserved while digging, drilling, boring,
            cutting or any other operation during the modification of an existing element, or the construction of a
            new element in the proximity of the existing one.

A.5.33        Block any fire exits or any fire suppression equipment at any time;

A.5.34        Block any outside lanes;

A5.35         Leave or wander away from the designated work area;

A5.36         Use any Concordia waste container for disposal of project waste. (Contractors are responsible for
              removal of all hazardous and non-hazardous waste produced as a result of their work).

A.6.0 Incident Reporting
CONTRACTORS & SUBCONTRACTORS MUST:

A.6.1         Report all accidents, injuries, chemical spills and any other safety incidents immediately to the
              Project Coordinator/Manager;

A.6.2         In case of serious accident, summon help or, if the accident puts others at risk (e.g. fire, breaking gas
              pipes), sound the evacuation alarm by activating a red pull station located at each exit, or call 9-911
              from a Concordia phone and/or contact Security (SGW: 3717; Loyola: 3707);

A6.3          Summon immediate help from Concordia Security in case of any chemical spill (SGW: 3717; Loyola:
              3707). All spills must be contained and cleaned up by trained personnel.
A.7.0 Fire
IN THE EVENT OF A FIRE OR WHEN THE FIRE ALARM SOUNDS, CONTRACTORS &
           SUBCONTRACTORS MUST:

A.7.1         Stop all work immediately;

A.7.2         Lower any suspended loads;


Initials: __________                             Page 42 de 44
     Purchasing Services                                            Tender Document no. UC – 0410027(DD)



A.7.3        Shut off and secure all equipment;

A.7.4        Evacuate the area by a predetermined route as covered in the pre-project safety review;

A.7.5        Sound fire alarm, if not already activated, by pulling the red pull station located at all emergency exit
             doors;

A.7.6        Remain in the assembly area until an all clear has been given by the appropriate personnel.



A.8.0 Asbestos
IF THE CONTRACTOR OR SUB-CONTRACTOR DISCOVERS MATERIALS WITH ASBESTOS, THE
            CONTRACTOR AND THE SUB-CONTRACTOR MUST:

A.8.1 Interrupt or suspend work and immediately advise the Project Coordinator/Manager.

A.8.2 Work cannot be resumed prior to having received instructions in this regard.

A.9.0     Suspension of Work

A.9.1        A designated representative of the University may alert a contractor or subcontractor when they see
             circumstances which endanger personnel, areas surrounding or adjacent to the worksite or work in
             progress.

A.9.2        The contractor and subcontractor must take immediate steps to rectify the situation or stop the work, in
             order to protect the personnel, work in progress and surrounding areas.

A.10. 0   Violations

A.10.1       Violation of any of these Rules may constitute a breach of the Contractor‘s agreement with Concordia
             and lead to the termination of the agreement and a claim for compensation and/or damages by
             Concordia against the Contractor.




Initials: __________                              Page 43 de 44
       Purchasing Services                                     Tender Document no. UC – 0410027(DD)




Contractor: ________________________________________________________
       Signature

                 ________________________________________________________
                 Print Name of Signatory and Name of Contractor

                 ________________________________________________________
                 Print Name of Contractor Contact Person and Telephone Number

                 ________________________________________________________
                 Date


Concordia Project Coordinator/Manager:


Coordinator/Manager’s Telephone Number:



Day:                                      After Hours:                     ____________




         Emergency Action:

         From any University telephone dial 3717 (SGW) or 3707 (Loyola) for Security and/or 9-
         911;
         From Bell pay telephones on Campus dial 911 and/or dial 848 3717 (SGW) or 3707 (LOYOLA)
         without charge;
         From Red Emergency Telephones pull the handset or push the button and wait for
         Security to respond;
         From Cellular Telephones dial 848-3717 (SGW) or 848-3707 (LOYOLA) and/or dial 911;
         Pull red fire alarm pull station




Initials: __________                          Page 44 de 44

				