Docstoc

C-Band Transceiver

Document Sample
C-Band Transceiver Powered By Docstoc
					                                                                      S A T E L L I T E C O M M U N I C A T I O N S




C-Band Transceiver
                                           5700 series
         The CODAN™ 5700 series C-Band transceivers offer a wide range of distinctive
         advantages and enhanced features for satellite communications systems based
         in remote or challenging geographic regions.

         Available in dual synthesiser, standard or extended C-Band operation and 70 or
         140 MHz IF configurations—and a range of power outputs—the 5700 provides
         industry leading technical performance.

         KEY      FE AT URE S

         Durability                        RF performance                        power supply unit with field
                                                                                 selectable 115/230 V operation.
         The 5700 series is designed and   RF performance is superb,
         tested to meet its performance    particularly: intermodulation
                                                                                 The AC power supply unit is
         specifications in an ambient      performance, gain stability over
                                                                                 extremely robust and particularly
         temperature range from –40°C to   temperature and flatness across
                                                                                 suited for operation from poor
         +55°C and up to 100% relative     the IF band.
                                                                                 quality AC supplies.
         humidity, ensuring long-term
         survival in extreme conditions.   The 5700 also boasts industry
                                           leading spurious and harmonics        Internal protection
         The thermal protection provided   specifications while guaranteed       Internal protection against high
         allows operation up to +60°C      RF performance ensures                temperature and short or open
         ambient. Field experience shows   expensive system link margins do      circuit RF output is standard. As
         that MTBFs of greater than        not have to be used to cope with      well, input voltage detection
         100,000 hours can be expected.    RF transceiver variations. The        ensures reliable shutdown and
                                           5700’s high linearity and low         restart under brownout or
                                           spurious characteristics              blackout conditions.
                                           contribute to superior
                                           multi-carrier performance.            External protection
                                                                                 All user access is via a transparent
                                           Output power options                  cover, which can be removed
                                           Output ratings of 20 and 40 watts     without exposing major internal
                                           are standard, while higher power      electronics to the elements.
                                           options are also available.           Special sealant is used to ensure
                                                                                 the sealing integrity of all
                                           Power consumption                     connectors.
                                           Codan’s C-Band transceivers all
                                                                                 RF modules are fully sealed and
                                           feature low power consumption
                                                                                 pressure tested to 34 kPa (5 psi).
                                           and low temperature rise,
                                                                                 Particle and moisture penetration
                                           ensuring internal components do
                                                                                 is rated to IP68 and the units are
                                           not suffer undue stress.
                                                                                 submersible to 3 metres.
                                           Power supply
                                           The 5700 features a 48 V DC
 C-Band transceiver 5700 series            floating input (37 V to 72 V range)
 with optional power supply unit           with reverse polarity protection.
                                           This is ideal for battery backup
                                           and solar-powered systems. In
                                           addition, the 5700 may be
                                           supplied with an optional AC
                                   A D VANC ED                   FE AT UR E S

                                   Enhanced monitor and control                           organisers without requiring                   Redundancy switching system
                                                                                          proprietary software. The
                                   All operating functions can be                                                                        A redundancy switching system is
                                                                                          versatile configuration options
                                   controlled and monitored via the                                                                      available to provide an automatic
                                                                                          support: contact closure, RS232,
                                   serial interface. The operating                                                                       changeover to a second
                                                                                          RS422 and RS485 (2 or 4 wire).
                                   configuration is stored in EEPROM                                                                     transceiver to maximise link
                                   to ensure the setup parameters                                                                        availability and minimise any
                                                                                          Two dedicated controllers are
                                   are restored in the event of a                                                                        disruption to service.
                                                                                          available from Codan:
                                   power failure.
                                                                                                                                         This system is fully outdoor
                                                                                                   5560 Hand-Held Controller,
                                   Universal interface                                                                                   mounted, but can be supplied
                                                                                                   suitable for in the field
                                   compatibility                                                                                         with the 5587 Redundant System
                                                                                                   installation setup
                                   The 5700 has universal interface                                                                      Monitor to provide indoor
                                   compatibility capable of                                        5570 Remote Controller,               monitor and control.
                                   operating with dumb terminals,                                  suitable for indoor rack
                                   laptop/PC emulating terminals,                                  mounting to provide
                                   hand-held terminals and personal                                permanent monitoring and
                                                                                                   control capabilities

                                   M A JOR CO NFIGU RAT ION OPT IONS

                                    Frequency bands (MHz)                   Transmit                         Receive
                                    2     C-Band Extended                   5850–6425                        3625–4200
                                    Transmit/receive frequency control
                                    D     Dual synthesiser
                                    Bandwidth
                                    N     Narrow band (40 MHz) field selectable 70 or 140 MHz IF
                                    W     Wide band (80 MHz)                140 MHz IF
                                    SSPA output
                                    N     N-type connector output
                                    W     WR-137 waveguide output
                                    M     SSPA monitor port                 only available on 10 and 20 W
                                    LNA                                                                                                          Redundancy Switching System
                                    Options and accessories
                                    Hand-held Controller
                                    Remote Controller
                                    Redundancy Switching System



                                  Equipment descriptions and specifications are subject to change without notice or obligation.




                                                                                                                                                 5700 transceivers antenna
                                                                                                                                                 mounted in 1:1 configuration

                                                                                           COD A N             QUALI TY           AN D     SER VIC E

                                                                                          All C-Band transceivers are built              Codan’s fully trained staff and
                             5570 Remote Controller                                       and tested in Codan’s ISO9001                  agents provide in-factory and
                                                                                          quality certified manufacturing                in-country training services, and
                                                                                          facility, and undergo 100% burn                complete installation and on-site
                                                                                          in and performance monitoring                  assistance. This service is backed
CODAN™ is a trademark of                                                                  over the temperature range                     up by a 24 hour customer service
Codan Limited. Other brand, product
and company names mentioned in this                                                       specified.                                     line and a warranty of three years
document are trademarks or registered
trademarks of their respective holders.
                                                                                                                                         on manufacturing, design or
                                             5560 Hand-held Controller                             0682                                  component defects.
                     Head Office                                  Asia Pacific                                 EMEA                            Americas      12-20069 Issue 10: 2/2010

                     Codan Limited                                Codan Limited                                Codan (UK) Ltd                  Codan US, Inc.
                     ABN 77 007 590 605                           81 Graves Street                             Unit C4 Endeavour Place         8430 Kao Circle
                     81 Graves Street                             Newton SA 5074                               Coxbridge Business Park         Manassas VA 20110
                     Newton SA 5074                               AUSTRALIA                                    Farnham Surrey GU10 5EH         USA
                     AUSTRALIA                                                                                 UNITED KINGDOM
                     Telephone +61 8 8305 0311                    Telephone +61 8 8305 0311                    Telephone +44 1252 717 272      Telephone +1 703 361 2721
                     Facsimile +61 8 8305 0411                    Facsimile +61 8 8305 0411                    Facsimile +44 1252 717 337      Facsimile +1 703 361 3812
                     www.codan.com.au                             asiasales@codan.com.au                       uksales@codan.com.au            ussales@codan.com.au
                                                                                           S A T E L L I T E C O M M U N I C A T I O N S




                 C-Band Transceiver
                                                                5700 series                                  SP E CI F IC AT IO N S
  TRA N S M IT         S E C T IO N                                        RE C E I VE      S E C T I O N    ( E XC L U D I N G       L N A )

IF input                                                                 RF input
Frequency range                                                          Frequency range
    Narrow BW option            70 ± 20 MHz/140 ± 20 MHz selectable          Band 2 (Extended)              3.625–4.200 GHz
    Wide BW option              140 ± 40 MHz                             Impedance                          50 Ω
Impedance                       50/75 Ω selectable                       Connector                          N female
Connector                       N female                                 VSWR                               1.4:1 maximum
Return loss                     18 dB minimum @ 50 Ω                     Noise figure                       18 dB typical
Gain specification                                                       DC output (switch selectable)      +15 V @ 75 to 250 mA
Gain                                                                     IF output
    20 W and 40 W               74 dB nominal                            Frequency range
Attenuator range                0 dB to 25 dB nominal                        Narrow BW option               70 ± 20 MHz/140 ± 20 MHz selectable
Attenuator step size            1 dB nominal                                 Wide BW option                 140 ± 40 MHz
Gain flatness                                                            Impedance                          50/75 Ω selectable
    Narrow BW option            ±1.0 dB maximum, 40 MHz                  Connector                          N female
    Wide BW option              ±2.0 dB maximum, 80 MHz                  Return loss                        18 dB minimum @ 50 Ω
Gain stability                  ±1.5 dB maximum, –40°C to +55°C
                                                                         Gain specification
RF output                                                                Gain                               45 dB nominal
Frequency range
                                                                         Attenuator range                   0 dB to 30 dB nominal
    Band 2 (Extended)           5.850 to 6.425 GHz
                                                                         Attenuator step size               1 dB nominal
Connector                       N female, or
                                                                         Gain flatness
                                CPR137G (Band 2 only)
                                                                             Narrow BW option               ±1.0 dB maximum, 40 MHz
VSWR                            1.5:1 maximum
                                                                             Wide BW option                 ±2.0 dB maximum, 80 MHz
20 W SSPA                                                                Gain stability                     +5.0/–4.0 dB maximum, –40°C to +55°C
Output power (1 dB GCP)         +44.0 dBm (25 W) typical                 Image rejection                    50 dB minimum
                                +43.0 dBm (20 W) minimum                 Spurious output                    –65 dBm maximum
Carrier to intermodulation      –27 dBc, two carriers, each @
ratio                           6 dB OPBO from 1 dB GCP                  Phase noise (SSB)*
                                                                         100 Hz                             –60 dBc/Hz maximum, –75 dBc/Hz typical
40 W SSPA                                                                1 kHz                              –70 dBc/Hz maximum, –80 dBc/Hz typical
Output power (1 dB GCP)         +46.0 dBm (40 W) typical                 10 kHz                             –80 dBc/Hz maximum, –85 dBc/Hz typical
                                +45.7 dBm (37 W) minimum                 100 kHz                            –90 dBc/Hz maximum, –95 dBc/Hz typical
Carrier to intermodulation      –25 dBc, two carriers, each @
ratio                           6 dB OPBO from 1 dB GCP
                                                                         Synthesiser step size              1 MHz
                                                                         Frequency stability
Spurious output                 Meets EN301443 with 53 dBi
                                                                         –40°C to +55°C                     ±2 x 10–8
(including harmonics)           antenna gain
                                                                         Aging                              ±1 x 10–7/year
Phase noise (SSB)*
100 Hz                          –60 dBc/Hz maximum, –75 dBc/Hz typical
1 kHz                           –70 dBc/Hz maximum, –80 dBc/Hz typical
10 kHz                          –80 dBc/Hz maximum, –85 dBc/Hz typical
100 kHz                         –90 dBc/Hz maximum, –95 dBc/Hz typical

Synthesiser step size           1 MHz
Frequency stability
–40°C to +55°C                  ±2 x 10–8
Aging                           ±1 x 10–7/year




                                                                                                                           *Excludes mains related sidebands.
  LO W        N O IS E        A M P L I FI E R                                             Remote monitoring functions (serial interface): Standby, On, Warm-up,
                                                                                           SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan
Indicative specifications; LNAs with lower noise temperatures are also                     fault, SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive
available.                                                                                 frequency*, Transmit attenuation*, Receive attenuation*, Cable
                                                                                           compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm
Input                                                                                      enable*, Fan alarm enable*, Temperature compensation*, Address*, SSPA
Interface                                 CPR229G                                          mode*, Converter lock, Packet protocol*, IF impedance,*, IF frequency*,
Noise temperature                         40 K typical @ 25°C                              Power-up mode

Gain specification
                                                                                           Remote control functions (serial interface): Power control (standby/on),
Gain                                      50 dB minimum
                                                                                           SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive
Output                                                                                     frequency*, Transmit attenuation*, Receive attenuation*, Cable
1 dB GCP                                  +5 dBm minimum                                   compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm
                                                                                           enable*, Fan alarm enable, Temperature compensation select*, Address range*,
Impedance                                 50 Ω
                                                                                           SSPA mode*, Packet protocol*, IF impedance*, IF frequency*, Power-up mode
Connector                                 N female
VSWR                                      2:1 maximum                                      All of the above serial interface functions are accessible via the Remote
                                                                                           Controller 5570. The functions supported by the Hand-Held Controller 5560
  TRA N S M IT RE JE C T FI L TE R (O P TI O N A L )
                                                                                           are indicated by an (*)
Indicative specifications; TRFs to cover bands 2, 3 and 4 are available.
                                                                                           Remote monitoring functions (contact closure): Standby, Warm-up, SSPA
Insertion loss                            0.05 dB maximum
                                                                                           activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault
Rejection                                 55 dB minimum
                                                                                           Remote control functions (contact closure): Power control (standby/on),
  PO W E R                                                                                 SSPA inhibit control, SSPA activate control
Input voltage                             42 to 72 V DC (floating input) standard
                                                                                             E NV IR O N M E NT A L
                                          115/230 V AC, ±15% with Power Supply Unit

Power consumption                                                                          Converter module and SSPA module
                                                                                           Temperature                       –40°C to +55°C
DC              20 W                      200 W maximum SSPA On
                40 W                      280 W maximum SSPA On                            Relative humidity                 100%
                                          40 W maximum SSPA Off                            Cooling                           Converter—Convection
AC              20 W                      310 VA maximum SSPA On                                                             20 W and 40 W—Forced air
                40 W                      370 VA maximum SSPA On                           Weatherproofing                   Sealed to 34 kPa
                                          80 VA maximum SSPA Off
                                          (all @ nominal AC voltage)                       Power supply unit
                                                                                           Temperature                       –40°C to +55°C
                                                                                           Relative humidity                 100%
                                                                                           Cooling                           Convection
  M O N I TO R            A N D       CO N T RO L
                                                                                           Weatherproofing                   Sealed to IP65
LNA interface                                                                                P HY S I C A L
DC output                                 +15 V @ 75 to 400 mA
Alarm input                               Current monitoring as specified, and             All dimensions are measured over the connectors.
                                          contact closure; O/C is fault condition          Size
Control panel facilities                                                                   Converter module                  110 mm W x 410 mm D x 240 mm H
Indicators: Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault,              SSPA module, 20 W and 40 W
SSPA fault, Temperature fault, Fan fault                                                      N-type output option           165 mm W x 415 mm D x 215 mm H
                                                                                              Waveguide output option        165 mm W x 420 mm D x 215 mm H
Controls: Power control (off/standby/on), SSPA control (inhibit/remote/                    Power Supply Unit                 200 mm W x 160 mm D x 370 mm H
activate), Serial interface settings, LNA supply via Rx RF Input connector,
Mains/Battery supply select
                                                                                           Weight
                                                                                           Converter module                  8 kg
Remote monitor and control facilities                                                      SSPA module, 20 W or 40 W         9 kg
Serial interface standards                RS232, RS422 (RS485)                             Power Supply Unit                 10 kg
Protocol standards                        ASCII, Packet (RS485)
Packet protocol address                   0 to 127
range




CODAN™ is a trademark of
Codan Limited. Other brand, product
and company names mentioned in this
document are trademarks or registered
trademarks of their respective holders.
                                                                                    0682                            Specifications subject to change without notice or obligation


                     Head Office                           Asia Pacific                      EMEA                                Americas 12-20070 Issue 12: 1/2010

                     Codan Limited                         Codan Limited                     Codan (UK) Ltd                      Codan US, Inc.
                     ABN 77 007 590 605                    81 Graves Street                  Unit C4 Endeavour Place             8430 Kao Circle
                     81 Graves Street                      Newton SA 5074                    Coxbridge Business Park             Manassas VA 20110
                     Newton SA 5074                        AUSTRALIA                         Farnham Surrey GU10 5EH             USA
                     AUSTRALIA                                                               UNITED KINGDOM
                     Telephone +61 8 8305 0311             Telephone +61 8 8305 0311         Telephone +44 1252 717 272          Telephone +1 703 361 2721
                     Facsimile +61 8 8305 0411             Facsimile +61 8 8305 0411         Facsimile +44 1252 717 337          Facsimile +1 703 361 3812
                     www.codan.com.au                      asiasales@codan.com.au            uksales@codan.com.au                ussales@codan.com.au

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:66
posted:4/18/2010
language:English
pages:4
Description: C-Band Transceiver