Docstoc

Air Release Foaming, Air Release & Emulsification

Document Sample
Air Release Foaming, Air Release & Emulsification Powered By Docstoc
					                                                      Air Release                      Foaming, Air Release & Emulsification

                                                                                                                                                                                    AIR RELEASE

15850-4         SETA AIR RELEASE VALUE APPARATUS                                                                                              SPECIFICATIONS
                                                                                                                                              Max. Air Temperature:       85°C
                ASTM D3427; IP 313; BS 2000 Part 313; DIN 51 381; ISO 9120; NF T60-149                                                        Sample Temp. Range:         Ambient to 75°C
                ●   Ambient to 75°C temperature range              Determines the time taken for hydraulic fluids                             Voltage:                    110/120V, 50/60Hz
                                                                   and lubricating oils to release entrained air                                                          220/240V, 50/60Hz
                ●   200kPa maximum air pressure
                                                                   and gases.                                                                 Power:                      170W
                ●   23l/min maximum flow rate                      The main unit comprises an air heater, fine                                Size (HxWxD):               46 x 38 x 35cm
                ●   Optional automated density monitoring          control pressure regulator, pressure gauge,                                Weight:                     8.5kg
                                                                   and mounting clip for the test vessel. An
                                                                   interlocked 3 pin socket provides power to
                                                                   an external air pump (not supplied) when the
                                                                   heater is on. The digital temperature controller
                                                                                                                                              ACCESSORIES - Air Release Value App.
                                                                   is housed in a separate unit. The instrument is                            REQUIRED
                                                                   protected by an overtemperature cut-out.                                   15870-4    CIRCULATING WATER BATH, (see below).
                                                                                                                                              20290-3    AIR PUMP, (for details see page 146).
                                                                   An automated density balance (Seta 15880-6) is
                                                                                                                                              15860-0    SETA TEST VESSEL, glass, comprises a
                                                                   available as an accessory.                                                            jacketed sample tube, matched air inlet
                                                                   SUPPLIED WITH: connection tubing, digital                                             capillary, baffle plate and air outlet tube.
                                                                   temperature control unit, mains lead and                                   15865-0    DIGITAL THERMOMETER AND
                                                                                                                                                         THERMOCOUPLES, for monitoring sample
                                                                   instruction manual.                                                                   temperature.
                                                                   Note: Requires connection to a suitable air                                16125-0    DIGITAL THERMOMETER AND PROBE, for
                                                                   supply and a Density Balance.                                                         measuring air inlet temperature before the
                                                                                                                                                         test.
                                                                                                                                              15880-6    DENSITY BALANCE, (see below).
                                                                                                                                              99200-2    LABORATORY OVEN, for warming test
                                                                              SETAPLUS EXTENDED WARRANTY AVAILABLE                                       sample, (for details see page 147).
        15850-4 and 15880-5 Balance (supplied separately)                                                                                     OPTIONAL
                                                                                                                                              45000-0    SETAPLUS EXTENDED 12 MONTH
                                                                                                                                                         WARRANTY

15880-6         SETA DENSITY BALANCE
                ASTM D3427; IP 313; BS 2000 Part 313; DIN 51 381; ISO 9120; NF T60-149
                ● Optimised for use with Seta Air                                                                                                                                                        12
                  Release Value Apparatus                                     SOFTWARE INCLUDED
                ● Automatic density calculation
                ● ±0.001g/ml resolution                                       CALIBRATION CERTIFICATE (WORKS)

                The Seta Density Balance comprises an
                electronic balance with a 10ml glass sinker,
                platinum wire and Seta-ARV software.
                                                                   SPECIFICATIONS
                                                                   Resolution:                          ± 0.001g/ml
                The software monitors the output of the
                                                                   Voltage:                             110/120V, 50/60Hz
                balance, calculates the density of the sample
                                                                                                        220/240V, 50/60Hz
                prior to and during the test, and determines the
                time taken for the sample to reach the target      Size (HxWxD):                        7 x 24 x 27cm
                density.                                           Weight:                              7kg
                SUPPLIED WITH: Seta ARV software, platinum
                wire, glass sinker, stand, connecting cable,
                mains lead and instruction manual.                  CONSUMABLES - Density Balance
                Note: Requires connection to a compatible           2 Years / 2000 Tests                                             Qty
                personal computer (not supplied).                   15880-201 SINKER, 10ml, glass . . . . . . . . . . . . . . . . . . . . 1
                                                                    15880-202 WIRE, 160mm, platinum . . . . . . . . . . . . . . . . . 1                       15880-6



15870-4         CIRCULATING WATER BATH
                ● Temp range ambient +5°C to 120°C                 SUPPLIED WITH: mains lead and instruction
                                                                   manual.
                ● Integral stirrer
                ● Over-temperature and low liquid level
                  protection                                       SPECIFICATIONS
                ● 12 litre bath                                    Temperature Range:                   Ambient +5°C to 120°C
                                                                   Temperature Stability:               ± 0.1°C
                A compact thermostatic bath, digitally             Volume:                              12 litres
                controlled to an accuracy of ±0.1°C across a
                                                                   Voltage:                             110/120V, 50/60Hz
                temperature range of ambient +5°C to 120°C                                              200/240V, 50/60Hz
                with a stirrer to ensure even temperature
                                                                   Power:                               1.4 KW
                distribution.
                                                                   Size (HxWxD):                        35 x 35 x 33cm
                The unit is equipped with over-temperature
                and low liquid level protection devices.           Weight:                              12.5kg
                                                                                                                                                                                               15870-4




 T   +44 (0) 1932 564391                F   +44 (0) 1932 568363             E    sales@stanhope-seta.co.uk                                     W       www.stanhope-seta.co.uk                           109

				
DOCUMENT INFO
Shared By:
Categories:
Stats:
views:15
posted:3/24/2010
language:English
pages:1
Description: Air Release Foaming, Air Release & Emulsification