Universal Air Seal Kit HCASK by housework

VIEWS: 42 PAGES: 4

									                                        Universal Air Seal Kit: HCASK


   Implement Data Centre best practices by blocking and controlling air
          flow in and around enclosures, floor s and ceilings.




TAB Technical Environment’s Universal Air Seal Kit can be used to prevent bypass airflow by sealing

open areas under the enclosure, within the enclosure or in unique applications such as between TAB’s

Heat Containment System (HCS) chimneys. The kit can also be used to prevent dust or particulate matter

from entering the enclosure, a potential source of damage to your valuable equipment. This new product

is an important component of TAB Technical Environment’s airflow management strategy and our heat

containment product offering. Reducing bypass airflow and particulate matter is critical requirement for

data centres looking to maximize efficiency, contain costs and minimize environmental impact by reducing

their carbon footprint. The Universal Air Seal Kit consists of 24 linear feet of sealing material and is an

ideal, cost effective solution to prevent bypass airflow and air mixing.
                                      General Description and Function
   The Universal Air Seal Kit consists of six square foam bars that are 2.25”H X 2.25”W X 48”L. The 24
linear feet of sealing material can be customized for almost any application. It can easily be cut to length
using a good pair of scissors. It can also be cut length-wise for narrow spaces. An installation tool is
included for forming the material into narrow spaces; it is also easily installed by hand.
   The material is the perfect solution to block bypass airflow in areas that have been difficult to address
in the past. The material can be used to seal the area between the sides of the rails and a divider or side
panel. In addition to blocking bypass airflow by the sides of the rails you can still route cables between the
foam material and the side or divider panel. If the cable bundle is large, a small area of material can be
removed for a custom fit. The material can be used to prevent bypass airflow under enclosures by
installing the material under the frame. For enclosures already installed in the field, the material can be
applied in front of the levelers. If the application is a fresh install the material can be placed behind the
levelers, which will leave access to the levelers for installation personnel.
   Another application for the material is between the HCS chimneys. While some HCS applications
eliminate the hot aisle-cold aisle layout, some clients only use HCS for select equipment. The Air Seal Kit
is a great solution to seal the area between HCS Chimneys in these situations. It can also be used to seal
the area between the 9U Cisco Airflow Director and the side or divider panel. The Airflow Director is used
in conjunction with vertical brush strips, which are modified. The foam material can replace the section of
brush strip that was removed; just place the material between the outside of the Airflow Director and the
side or divider panel.
                                                     Features:
              • Cost effective solution for sealing open spaces and preventing bypass airflow.
              • Easy to install and conforms to spaces that are traditionally difficult to seal.
              • An integral component of Wright Line’s Airflow Management Solution. The Air Seal Kit
               reinforces the company’s commitment to offer cost effective green solutions.


     Product Availability:                                Sales Tools:
     • Order Acceptance: Immediately                      • Application note (attached)
     • Lead Time: 2-4 Weeks                               • Technical Specifications/Certification
                                                          attached

     Primary Market:                                      Release Notes:
     • Any facility that has enclosures; or that is       • Material can be used in any manufacturer’s
     deploying enclosures with open areas where           enclosure.
     bypass airflow can occur.                            • Use two pieces of material together to seal
     • Any client that is trying to improve the overall   large open areas.
     efficiency of their Data Center.                     • Cabling can easily be routed around the
                                                          material without effecting performance.
                                                          • Meets flammability requirements per UL94
                                                          HF-1 and MVSS 302. (self extinguishing)
      Application Note for HCASK Universal Air Seal Kit




                         1                                                   2




                         3                                                   4



(1) Air Seal Kit material applied between the outside edge of the 9U airflow director and the divider panel.

(2) Air Seal Kit material applied between the outside edge of the rail and the divider panel.

(3) Air Seal Kit material applied between the bottom of the frame and the raised floor (door closed).

(4) Air Seal Kit material applied between the bottom of the frame and the raised floor (door open).
                     HCASK Universal Air Seal Kit
             Technical Specifications/Certifications



          Test             Minimum     Maximum      Units
Pore Size (Visual)            55         70             -
Density                      1.75        2.10       Lbs/ft3
Tensile                      16.0         -            PSI
Elongation                    90          -            %
Tear                          1.1         -          Lb/in
CLD 25%R (2”x2”x1”)          0.60         -            PSI
CLD 50%R (2”x2”x1”)          0.70         -            PSI
Compression Set 50%            -         30            %
Flammability – UL94 F1       Pass         -             -
Flammability – MVSS 302      Pass         -             -




         At “TAB Technical Environments” we deliver
    customized, scalable, reliable solutions for today’s
               technology intensive workplace.
 Find out more at www.TABTE.ca or call 1-800-667-4020

								
To top