					        CAISO Generator Reference Data Template (GRDT) - MSG Draft
                                Version GRDT.3.0 (Draft)



Report generation timestamp :
SCID              :
Resource Type :
Resource ID       :
Trade Date        :
                                                              Generator RDT Definitions
         RDT Column Name
(Gray-shaded fields are for reference                                                                                  Can be
                                         Column Code     Unit                         Definition                                            Business Rule
 only and are not modifiable through                                                                                    Null?
       the RDT update process)

Participating Generator Agreement         PGA_NAME       text    The name of an agreement between the CAISO and          Y
Name                                                             a Participating Generator; a pro forma version of
                                                                 which is set forth in Appendix B.2 of the CAISO
                                                                 Tariff.
Scheduling Coordinator ID                   SC_ID        text    An entity certified by the CAISO for the purposes       Y
                                                                 of undertaking the functions specified in Section
                                                                 4.5.3 of the CAISO Tariff.
Resource ID                                 RES_ID       text    The ISO resource identifier used for tracking each      N
                                                                 resource for market scheduling and outage
                                                                 coordination purposes.
Resource Name                             RES_NAME       text    Descriptive name for the Resource.                      N
Resource Type                             RES_TYPE       text    Descriptive identifier denoting the type of             N
                                                                 resource: Generating Unit, Tie Generator, Load.


Aggregate?                              AGGREGATE_YN     Y/N     An aggregation that consists of several individual      N
                                                                 "child" resources.
Energy Type                              ENERGY_TYPE     text    Energy Type (populated if RES_TYPE='TG'):               Y      - Leave NULL for Generator resources
                                                                 DYN - Dynamic Resource
                                                                 FIRM - A/S Resources specifically for ETC/TOR use
                                                                 All others are blank.


Primary Fuel Type                         FUEL_TYPE      text    Description of primary fuel type; such as, Natural
                                                                 Gas, Oil, Nuclear, etc.
Prime Mover Technology                  GEN_TECH_TYPE    text    Description of prime mover technology associated
                                                                 with the Generating Unit; such as, Hydro Turbine,
                                                                 Gas Turbine, Combined Cycle, etc.


Generator Type                            GEN_TYPE       text    H - Hydro resources
                                                                 T - All other resources
Fuel Region                             FUEL_REGN_TYPE   text    The area of the state where the Generator lies -
                                                                 used for Gas-fired Generators.
Air Quality Managment District          AQM_DIST_TYPE    text    The Air Quality Management District or Air
                                                                 Pollution Control District in which the resource is
                                                                 located.
Maximum Generation Capacity                MAX_GEN       MW      The maximum normal capability of the Generating         N      - Cannot be null
                                                                 Unit.                                                          - Must equal the maximum output
                                                                                                                                level (last segment) in the RAMP and
                                                                                                                                HEAT curves
                                                                                                                                - Cannot be greater than the tested
                                                                                                                                Pmax (if unit was tested).
                                                                                                                                - Must be >= MIN_GEN

Minimum Generation Capacity                MIN_GEN       MW      For a Generating Unit, the minimum sustained            N      - Cannot be null
                                                                 operating level (Pmin or plant minimum) at which               - Must be 0, or >= 0.1
                                                                 it can operate at a continuous level.                          - Must equal the minimum output
                                                                                                                                level (segment 1) in the RAMP curve
                                                                                                                                and in the HEAT curves
                                                                                                                                - Must be <= MAX_GEN


Minimum Dispatchable Level              MIN_DISP_LEVEL   MW      The minimum operating level at which a                  N      - Default value is set equal to
                                                                 Generating Unit is able to readily respond to a                MIN_GEN
                                                                 dispatch instruction.                                          - Must be greater than or equal to
                                                                                                                                MIN_GEN
Minimum On Time                    MIN_ON        Minutes   The minimum amount of time that a Generating          Y   - Cannot be null if FUEL_TYPE = GAS
                                                           Unit must stay on-line after starting up and
                                                           reaching PMin, prior to being shut down, due to
                                                           physical operating constraints. If no constraint,
                                                           then leave this field blank.


Maximum Daily On Time              MAX_ON        Minutes   The maximum amount of time that a Generating          Y
                                                           Unit can stay on-line per day, due to
                                                           environmental or physical operating constraints. If
                                                           no constraint, then leave this field blank.


Minimum Off Time                  MIN_OFF        Minutes   The minimum amount of time that a Generating          N   - Must be greater than or equal to the
                                                           Unit must stay off-line after being shut down, due        minimum startup time (segment 1) in
                                                           to physical operating constraints. Minimum Off            the startup curve
                                                           Time includes Startup Time.


Maximum Startups Per Day          MAX_STRT       Integer   The maximum number of times a Generating Unit         N   - Must be an integer (whole number),
                                                           can be started up within one day, due to                  1 or greater
                                                           environmental or physical operating constraints.


Minimum Load Cost              MIN_LOAD_COST     Dollar    The costs a Generating Unit or a Participating        Y   - Cannot be null if Cost Basis Type of
                                                           Load incurs operating at minimum load. The value          REGC (Registered) is selected
                                                           is needed for a resource with the Cost Basis of
                                                           Registered Cost (fixed value) only.
Cost Basis Type                COST_BASIS_TYPE    text     If Proxy Cost: The Operating Cost of a generating         - If REGC (Registered) is selected,
                                                           resource is calculated using the Heat Rate data in        Minimum Load Cost and Startup Cost
                                                           the Master File and daily gas price.                      must be provided
                                                           If Registered Cost: The Operating Cost is
                                                           determined from Start-up Cost and Minimum Load
                                                           Cost, or Pump Maximum Shutdown Cost registered
                                                           in the Master File.


Maximum Pump Capacity            MAX_PUMP         MW       The Maximum Operating Level of a Pump or a            Y   - Must have a value if
                                                           Pumped-Storage Hydro Unit operating as a hydro            GEN_TECH_TYPE = PTUR (Pump
                                                           pump.                                                     Storage)
Pumping Minimum Cost            MIN_PUMP_CST     Dollar    The minimum pumping cost                              Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pumping Factor                PUMPING_FACTOR     Number    Pumping factor of a pumping resource                  Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pump Maximum Daily Startups    PUMP_MAX_STRT     Integer   Maximum number of daily startups                      Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pump Minimum Up Time          PUMP_MIN_UP_TM     Minutes   Minimum pumping run time                              Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pump Minimum Down Time        PUMP_MIN_DWN_TM    Minutes   The minimum amount of time that a pumping             Y   - Must have a value if
                                                           resource must stay off-line after shutting down.          GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pump Maximum Shutdown Cost    MAX_PUMP_SD_CST    Dollar    The maximum pump shutdown cost                        Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Pump Shutdown Time            PUMP_SHTDWN_TM     Minutes   The pump shutdown time                                Y   - Must have a value if
                                                                                                                     GEN_TECH_TYPE = PTUR (Pump
                                                                                                                     Storage)
Variable Cost Option         COST_RANK_LMPM   Integer   A method of calculating Default energy Bids based     N   - Default setting is 1
                                                        on fuel costs and variable operations and                 - Only one of the three ranking fields
                                                        maintenance costs.                                        (COST_RANK_LMPM,
                                                        Rank 1, 2, or 3                                           NEGO_RANK_LMPM, and
                                                                                                                  PRC_RANK_LMPM) can be ranked as 1
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 2
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 3


Negotiated Rate Option       NEGO_RANK_LMPM   Integer   A method of calculating Default energy Bids based     N   - Default setting is 2
                                                        on a negotiation with the CAISO or the                    - Only one of the three ranking fields
                                                        Independent Entity.                                       (COST_RANK_LMPM,
                                                        Rank 1, 2, or 3                                           NEGO_RANK_LMPM, and
                                                                                                                  PRC_RANK_LMPM) can be ranked as 1
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 2
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 3


LMP Option                   PRC_RANK_LMPM    Integer   A method of calculating Default energy Bids based     N   - Default setting is 3
                                                        Locational Marginal Prices.                               - Only one of the three ranking fields
                                                        Rank 1, 2, or 3                                           (COST_RANK_LMPM,
                                                                                                                  NEGO_RANK_LMPM, and
                                                                                                                  PRC_RANK_LMPM) can be ranked as 1
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 2
                                                                                                                  - Only one of these three fields can
                                                                                                                  be ranked as 3


Reserve Capacity: Spin        RSRV_CAP_SPIN    MW       The portion of unloaded synchronized generating       Y   - Must have a value if CERT_SPIN is Y.
                                                        capacity that is immediately responsive to system         - Cannot be greater than the tested
                                                        frequency and that is capable of being loaded in          Spin capacity.
                                                        ten minutes, and that is capable of running for at        - Must be <= (MAX_GEN - MIN_GEN)
                                                        least two hours.


Reserve Capacity: Non-Spin   RSRV_CAP_NSPIN    MW       The portion of off-line generating capacity that is   Y   - Must have a value if
                                                        capable of being synchronized and Ramping to a            CERT_NSPIN_DAM and/or
                                                        specified load in ten minutes (or load that is            CERT_NSPIN_RTM flags are set to Y.
                                                        capable of being interrupted in ten minutes) and          - Cannot be greater than the tested
                                                        that is capable of running (or being interrupted.)        Non-spin capacity.
                                                                                                                  - Must be <= MAX_GEN


Certified PIRP                  CERT_PIRP      Y/N      Resource is treated as in Participating               Y
                                                        Intermittent Resource program and is certified (is
                                                        eligible for Settlements treatment as PIRP
                                                        participant)
Resource Adequacy Flag          RA_FLAG        Y/N      An identifier of a resource that is under the         Y
                                                        Resource Adequacy (RA) program. This flag is set
                                                        dynamically based on whether RR_CAPACITY on a
                                                        resource is greather than 0. The flag my change
                                                        monthly so the value represented should be
                                                        considered valid only for the trade date the report
                                                        is generated.
Must Offer Obligation Flag             MOO_FLAG       Y/N     An identifier of a resource that has a must offer       Y
                                                              obligation, either due to a RA obligation or
                                                              through other obligation (ie capacity market
                                                              procurement, RCST, etc.) This flag is set
                                                              dynamically based on the MOO_QUALIFIED flag
                                                              setting and whether a resource is designated RA or
                                                              RCST on a given Trade Date.

Resource Adeqacy Capacity             RR_CAPACITY      MW     The generation capacity of a Resource Adequacy          Y
                                                              Resource listed on a Resource Adequacy Plan and
                                                              a Supply Plan. This field also includes capacity
                                                              purchased through a backstop agreement, such as
                                                              Interim Capacity Procurement Mechanism. This
                                                              value may change monthly so the value
                                                              represented in this report should be considered
                                                              valid only for the trade date the report is
                                                              generated.

Must Offer Obligation Qualified      MOO_QUALIFIED    Y/N/R   Y - Resource is Must Offer                              N   - Default setting is R
                                                              N - Resource is not Must Offer                              - This field is set to N if USE_LIMIT
                                                              R - Resource is eligible for Must Offer based on RA         flag is Y
                                                              Capacity or RCST designation in any given trading
                                                              hour
Startup Code Type                   STARTUP_CD_TYPE   text    Code used to determine the startup                      Y   - This field is set to 'FAST' if Startup
                                                              characteristics. FAST: Generating Units that have           Time in segment 1 in Startup curve is
                                                              a Start Up Time of ten minutes or less and can              10 minutes or less and
                                                              provide non-spin. Blank: All other resources.               CERT_NSPIN_RTM = Y.
                                                                                                                          - Leave null for all others.
Participating Generator Agreement      PGA_PART       Y/N     An identifier of the PGA Resources.                     N   = Y if unit is on a PGA or QF-PGA,
Flag                                                                                                                      otherwise set to N
Constrained Output Generator Flag        COG          Y/N     The output of the generation resources is not           N
                                                              variable, ie PMax = PMin. Y: output is
                                                              constrained.
Certified for RUC                      CERT_RUC       Y/N     A resource that can participate in RUC market.          N   = Y for all Generators and TG
                                                              Currently all PGA resources can participate in the          resources
                                                              RUC market.
Market Power Mitigation                  LMPM         Y/N     An identifier of a resource that is subject to the      N   = Y for all Generators
Participation Flag                                            market power mitigation process. Defined per                = N for all TGs
                                                              tariff.
Certified for AS: Regulation           CERT_REG       Y/N     An indentifier of a resource that is certified to       N   = Y if unit is certified for Regulation
                                                              provide Regulation Reserve.                                 - If Y, the REG and RREG curves must
                                                                                                                          be defined


Certified for AS: Spin                 CERT_SPIN      Y/N     An indentifier of a resource that is certified to       N   = Y if unit is certified for Spin
                                                              provide Spinning Reserve.                                   - If Y, RSRV_CAP_SPIN must have a
                                                                                                                          value and the ROPR curve must be
                                                                                                                          defined
Certified for AS DAM: Non-Spin      CERT_NSPIN_DAM    Y/N     An indentifier of a resource that is certified to       N   = Y if unit is certified for Non-Spin
                                                              provide Non-Spinning Reserve in the DAM.                    - If Y, RSRV_CAP_NSPIN must have a
                                                                                                                          value and the ROPR curve must be
                                                                                                                          defined
Certified for AS RTM: Non-Spin      CERT_NSPIN_RTM    Y/N     An indentifier of a resource that is certified to       N   = Y if unit is certified for Non-Spin
                                                              provide Non-Spinning Reserve in the RTM. To be              - If Y, RSRV_CAP_NSPIN must have a
                                                              procured in the RTM, a unit must also have a                value and the ROPR curve must be
                                                              Startup Code Type of FAST.                                  defined
MSS Load Following Down              MSS_LD_FLNG_UP   Y/N     Identifier if a resource is load following down         Y
MSS Load Following Up               MSS_LD_FLNG_DWN   Y/N     Identifier if a resource is load following up           Y
FERC Qualifying Facility Flag              QF         Y/N     Identifier if a resource is a qualifying cogeneration
                                                              facility or small qualifying power production
                                                              facility, as defined in the Code of Federal
                                                              Regulations, Title 18, Part 292
Use Limit                         USE_LIMIT        Y/N      Identifier if a resource is energy use limited, such    N   - Default is N
                                                            as limitation of energy or emission control, etc.           = Y for Hydro resources (unless SC
                                                                                                                        requested exemption)
                                                                                                                        = Y for resources that have been
                                                                                                                        registered through Use Limit process


Operating Maintenance Cost    OPER_MAINT_COST     $/MWh     Variable operations and maintenance costs, a            N   - Cannot be null for Generators, TGs
                                                            component of the Variable Cost option for                   - $2/MWh is default value
                                                            calculating the Default Energy Bid.                         - $4/MWh if GEN_TECH_TYPE = GTUR
                                                                                                                        (Combustion Turbine) or RECP
                                                                                                                        (Reciprocating Engine)


Priority Type                    PRIOR_TYPE        text     MT - Regulatory Must Take resources                     Y
                                                            REGM - Regulatory Must-Run
                                                            RMR - Reliability Must Run
                                                            PIRP - Participant in PIRP program
Dispatchable                        DISP           Y/N      Designates a dispatchable resource                      N   - Cannot be null for Generators, TGs
                                                            NOTE: This flag is currently not being used. As
                                                            long as a resource has a bid, it will be dispatched
                                                            according to the bid.
RMR                                 RMR            Y/N      Designates a resource that has a Reliability Must       Y   = Y if resource is on an RMR contract
                                                            Run contract
Maximum Ramp Rate                  MAX_RR         MW/min    Represents the fastest Best Operating Ramp Rate         N
                                                            in the RAMP curve
Price Setter - DAM              PRC_SET_DAM        Y/N      Indicator of resource being able to set the price in    N   = Y for all Generators and TGs
                                                            DA market.
Price Setter - RTM              PRC_SET_RTM        Y/N      Indicator of resource being able to set the price in    N   = Y for all Generators and TGs
                                                            RT market.
Multi Stage Generator Flag         MSG_YN          Y/N      Indicator of a resource that is modeled with            Y   - If Y, at least 2 configurations and no
                                                            multiple configurations under the Multi-Stage               more than 10 must exist
                                                            Generator (MSG) model.
Startup Ramp Time             STARTUP_RAMP_TIME   Minutes   Represents the time it takes to physically ramp         Y   - Must be <= the minimum startup
                                                            unit from off-line to pmin.                                 time in the resource's startup curve
Supplied Configuration Flag   SUPPLY_CONFIG_YN     Y/N      This is a placeholder for future functionality. This    Y   - Set to N for all MSG configurations
                                                            flag will indicate whether the online configuration         - Blank if MSG_YN = N
                                                            ID for the MSG Resource will be provided to the
                                                            ISO in real-time. If "N", ISO systems will derive the
                                                            configuration ID based on telemetry and state
                                                            estimator solution.
Comment                                            text     Please enter comments regarding any changes             Y
                                                            made to the data on this worksheet.
                                        Multi Stage Generator Configuration Definitions (tab name=MSG_CONFIG)
         RDT Column Name
(Gray-shaded fields are for reference                                                                                        Can be
                                            Column Code       Unit                          Definition                                              Business Rule
 only and are not modifiable through                                                                                          Null?
       the RDT update process)

Resource ID                                    RES_ID         text     The ISO resource identifier used for tracking each      N
                                                                       resource for market scheduling and outage
                                                                       coordination purposes.
Configuration                                CONFIG_ID        text     Identifier of the MSG configuration                     N
Configuration Name                          CONFIG_NAME       text     MSG configuration name                                  N
Maximum Generation Capacity                   MAX_GEN         MW       The maximum normal capability at the                    N      - Config's MAX_GEN <= resource's
                                                                       configuration level.                                           MAX_GEN
                                                                                                                                      - Config's MAX_GEN >= config's MIN_GEN
                                                                                                                                      - Must equal the maximum output level
                                                                                                                                      (last segment) in the config's HEAT curve



Minimum Generation Capacity                   MIN_GEN         MW       For a configuration, the minimum sustained              N      - Config's MIN_GEN >= resource's
                                                                       operating level (Pmin) at which it can operate at a            MIN_GEN
                                                                       continuous level.                                              - Config's MIN_GEN <= config's MAX_GEN
                                                                                                                                      - Must equal the minimum output level
                                                                                                                                      (segment 1) in the config's HEAT curve




Minimum On Time                               MIN_ON         Minutes   The minimum amount of time that a configuration         Y
                                                                       must stay on-line after starting up and reaching
                                                                       PMin, prior to being shut down, due to physical
                                                                       operating constraints. If no constraint, then leave
                                                                       this field blank.
Minimum Off Time                              MIN_OFF        Minutes   The minimum amount of time that a configuration                - Must be greater than or equal to the
                                                                       must stay off-line after being shut down, due to               minimum startup time (segment 1) in
                                                                       physical operating constraints. Minimum Off Time               the startup curve
                                                                       includes Startup Time.


Minimum Load Cost                          MIN_LOAD_COST     Dollar    The costs a configuration incurs operating at           Y      - Cannot be null if Cost Basis Type of
                                                                       minimum load. The value is needed for a resource               REGC (Registered) is selected
                                                                       with the Cost Basis of Registered Cost (fixed
                                                                       value) only.
Reserve Capacity: Spin                     RSRV_CAP_SPIN      MW       At the configuration level, the portion of unloaded     Y      - Must have a value if CERT_SPIN is Y.
                                                                       synchronized generating capacity that is                       - Cannot be greater than the tested Spin
                                                                       immediately responsive to system frequency and                 capacity.
                                                                       that is capable of being loaded in ten minutes,                - Must be less than or equal to MAX_GEN -
                                                                       and that is capable of running for at least two                MIN_GEN of the configuration
                                                                       hours.
Reserve Capacity: Non-Spin                 RSRV_CAP_NSPIN     MW       At the configuration level, the portion of off-line     Y      - Must have a value if CERT_NSPIN_DAM
                                                                       generating capacity that is capable of being                   or CERT_NSPIN_RTM flags are set to Y.
                                                                       synchronized and Ramping to a specified load in                - Cannot be greater than the tested Non-
                                                                       ten minutes (or load that is capable of being                  spin capacity.
                                                                       interrupted in ten minutes) and that is capable of             - Must be less than or equal to MAX_GEN
                                                                       running (or being interrupted.)                                of the configuration


Configuration Shutdown                     SHUTDOWN_YN        Y/N      An identifier of a configuration that can shutdown      N
                                                                       without going through another configuration.


Default RA Provider Flag                   RA_PROVIDER_YN     Y/N      An identifier of the configuration that is the          N      - Only one configuration can be
                                                                       default RA provider.                                           designated as the default RA provider
Startup Ramp Time                        STARTUP_RAMP_TIME   Minutes   Represents the time it takes to physically ramp         Y      - Must be <= minimum startup time for
                                                                       from off-line to pmin.                                         this configuration in the CONFIG_STRT
                                                                                                                                      curve
Startup Code Type                STARTUP_CD_TYPE   text   Code used to determine the startup                    Y   - Set to 'FAST' if Startup Time in segment
                                                          characteristics. FAST: Configuration that has a           1 in Startup curve is 10 minutes or less.
                                                          Start Up Time of ten minutes or less and can              - Leave null for all others.
                                                          provide non-spin. Blank: All other configurations.


Certified for AS: Regulation        CERT_REG       Y/N    An indentifier of a configuration that is certified   N   - Set to Y if configuration is certified for
                                                          to provide Regulation Reserve.                            Regulation
Certified for AS: Spin              CERT_SPIN      Y/N    An indentifier of a configuration that is certified   N   - Set to Y if configuration is certified for
                                                          to provide Spinning Reserve.                              Spin
Certified for AS DAM: Non-Spin   CERT_NSPIN_DAM    Y/N    An indentifier of a configuration that is certified   N   - Set to Y if configuration is certified for
                                                          to provide Non-Spinning Reserve in the DAM.               Non-Spin


Certified for AS RTM: Non-Spin   CERT_NSPIN_RTM    Y/N    An indentifier of a configuration that is certified   N   - Set to Y if configuration is certified for
                                                          to provide Non-Spinning Reserve in the RTM. To be         Non-Spin
                                                          procured in the RTM, a unit must also have a
                                                          Startup Code Type of FAST.
Comment                                            text   Please provide an explanation for any changes         Y
                                                          made to the data on this worksheet.
SDRT Data Request Options




                            This page intentiona




         Page 9
  SDRT Data Request Options




This page intentionally left blank




             Page 10
SDRT Data Request Options




        Page 11
SDRT Data Request Options




        Page 12
SDRT Data Request Options




        Page 13
SDRT Data Request Options




        Page 14
            Scheduling                                                                                           Prime Mover
PGA Name   Coordinator ID Resource ID   Resource Name   Resource Type     Aggregate?   Energy Type   Fuel Type   Technology    Generator Type     Fuel Region

PGA_NAME      SC_ID        RES_ID        RES_NAME        RES_TYPE       AGGREGATE_YN ENERGY_TYPE FUEL_TYPE GEN_TECH_TYPE        GEN_TYPE        FUEL_REGN_TYPE
                     Maximum     Minimum                                                             Maximum
   Air Quality       Generation Generation   Minimum Dispatchable Minimum On Maximum On Minimum Off Startups Per                                         Maximum Pump Pumping Minimum
Managment District    Capacity   Capacity           Level             Time      Time        Time        Day        Minimum Load Cost      Cost Basis        Capacity       Cost

AQM_DIST_TYPE        MAX_GEN    MIN_GEN       MIN_DISP_LEVEL       MIN_ON     MAX_ON      MIN_OFF     MAX_STRT     MIN_LOAD_COST       COST_BASIS_TYPE    MAX_PUMP     MIN_PUMP_CST
                  Pump Maximum Daily                                               Pump Maximum Shutdown
 Pumping Factor        Startups      Pump Minimum Up Time Pump Minimum Down Time            Cost           Pump Shutdown Time   Variable Cost Option   Negotiated Rate Option

PUMPING_FACTOR    PUMP_MAX_STRT       PUMP_MIN_UP_TM       PUMP_MIN_DWN_TM          MAX_PUMP_SD_CST        PUMP_SHTDWN_TM       COST_RANK_LMPM         NEGO_RANK_LMPM
                                                                                                                                                                               Participating
                Reserve Capacity:   Reserve Capacity: Non-                      Resource       Must Offer     Resource Adeqacy   Must Offer Obligation                          Generator
  LMP Option          Spin                  Spin             Certified PIRP   Adequacy Flag   Obligation Flag     Capacity            Qualified           Startup Code Type   Agreement Flag

PRC_RANK_LMPM   RSRV_CAP_SPIN        RSRV_CAP_NSPIN          CERT_PIRP          RA_FLAG        MOO_FLAG       RR_CAPACITY         MOO_QUALIFIED          STARTUP_CD_TYPE       PGA_PART
                                    Market Power                                                                                                                                       FERC
Constrained Output Certified for       Mitigation     Certified for AS: Certified for   Certified for AS DAM:   Certified for AS RTM:   MSS Load Following                            Qualifying
 Generator Flag      RUC?          Participation Flag   Regulation       AS: Spin              Non-Spin                Non-Spin               Down           MSS Load Following Up   Facility Flag   Use Limit

      COG           CERT_RUC            LMPM            CERT_REG        CERT_SPIN       CERT_NSPIN_DAM          CERT_NSPIN_RTM          MSS_LD_FLNG_UP       MSS_LD_FLNG_DWN             QF          USE_LIMIT
Operating Maintenance                                     Maximum                                               Multi Stage                          Supplied Configuration
         Cost           Priority Type   Dispatchable RMR Ramp Rate   Price Setter - DAM   Price Setter - RTM   Generator Flag    Startup Ramp Time            Flag            Comment

OPER_MAINT_COST         PRIOR_TYPE        DISP     RMR   MAX_RR      PRC_SET_DAM          PRC_SET_RTM            MSG_YN         STARTUP_RAMP_TIME    SUPPLY_CONFIG_YN
Resource ID   Segment Type Segment Number Operating Level
Worst Operational Ramp Rate   Best Operational Ramp Rate   Comment
Resource ID   Segment Type Segment Number Heat Rate Operating Level
Heat Rate Heat Emission Rate   Average Cost Comment
Resource ID   Segment Type Segment Number Registered Cooling Time
Start-Up Time Start-Up Cost Start-Up Aux Start-Up Fuel Comment
Resource ID Segment Type Segment Number Lower MW of Forbidden Region
Upper MW of Forbidden Region   Forbidden Region Crossing Time   Comment
Resource ID Segment Type Segment Number Lower MW for Regulation Higher MW for Regulation
Comment
Resource ID Segment Type Segment Number Worst Regulation Ramp Rate   Best Regulation Ramp Rate
Comment
Resource ID Segment Type Segment Number Worst Operating Res Ramp Rate
Best Operating Res Ramp Rate   Comment
                                                 Maximum     Minimum
                                                 Generation Generation Minimum On Minimum Off
Resource ID   Configuration   Configuration Name Capacity    Capacity      Time       Time    Minimum Load Cost

  RES_ID      CONFIG_ID        CONFIG_NAME      MAX_GEN    MIN_GEN     MIN_ON      MIN_OFF    MIN_LOAD_COST
Reserve Capacity:   Reserve Capacity: Non-    Configuration   Default RA Provider
      Spin                  Spin               Shutdown               Flag           Startup Ramp Time   Startup Code Type

RSRV_CAP_SPIN        RSRV_CAP_NSPIN          SHUTDOWN_YN      RA_PROVIDER_YN        STARTUP_RAMP_TIME STARTUP_CD_TYPE
Certified for AS: Certified for   Certified for AS DAM:   Certified for AS RTM:
  Regulation       AS: Spin              Non-Spin                Non-Spin         Comment

 CERT_REG         CERT_SPIN       CERT_NSPIN_DAM          CERT_NSPIN_RTM
Resource ID   Configuration ID_From Configuration ID_To   Transition Cost
Max Transition Cost Transition Ramp Time Notification Time   Transition Fuel   Transition Energy
Max Daily Transitions   Default RA Path Sequence   Comment
Resource ID   Configuration ID   Segment Type Segment Number Operating Level
Worst Operational Ramp Rate   Best Operational Ramp Rate   Comment
Resource ID   Configuration ID   Segment Type Segment Number
Heat Rate Operating Level Heat Rate Heat Emission Rate   Average Cost Comment
Resource ID   Configuration ID   Segment Type Segment Number Registered Cooling Time
Start-Up Time Start-Up Cost Start-Up Aux Start-Up Fuel Comment
Resource ID   Configuration ID   Segment Type Segment Number Lower MW for Regulation
Higher MW for Regulation Comment
Resource ID   Configuration ID   Segment Type Segment Number
Worst Regulation Ramp Rate   Best Regulation Ramp Rate   Comment
Resource ID   Configuration ID   Segment Type Segment Number
Worst Operating Res Ramp Rate   Best Operating Res Ramp Rate   Comment