Docstoc

PSC - Excel

Document Sample
PSC - Excel Powered By Docstoc
					                                    Deficiencies per ships in PSC inspection, June 2009

Csae-1 (Port in Argentina)
Def.                                                                                                               Act.   ISM
         Type of deficiency                                     Details of deficiency
Code                                                                                                               Code   Code
 1220 Freeboard marks               1. Freeboard marks are not painted properly                                     17      -
 1220 Freeboard marks               2. Draft mark on midship are not painted properly                               17      -
 730 Fire fighting equipment        3. Main fire pipe has water leak on main deck at hold N°5 & 3                   17      -
      and appliances
 799 Other (fire safety)            4. One EEBD on bridge is discharged.                                            17     -
 745 Ventilation                    5. Closure of opening in funnels don´t work properly                            17     -
 1570 Nautical publications         6. Nautical publication Notice to Mariner, weekly edition are not up dated (    15     -
                                    last on board March 2009)
1570 Nautical publications          7. ISPS Code book, Code for safe carriage of grain in bulk are not available    15     -
                                    onboard.
2660 Water level indicator          8. Water ingress tester do not work properly (Hold No 5).                       17     -
1320 Anchoring devices              9. Port Anchor and twelve shackles missing.                                     99     -
2525 Masters responsibility         10. There are objective evidence that not exist exchange of information         18     5
     and authority                  between the master and the pilot ( The pilot card from xxxxxx to xxxxxxx
                                    port not signed by master and pilot).
2515 Company responsibility         11. There is objective evidence that the Company not complied with Master       18     3
     and authority                  requirements over publication update on board. (Master required
                                    publication update on March and not received)

Csae-2 (Port in Australia)
Def.                                                                                                               Act.   ISM
          Type of deficiency                                    Details of deficiency
Code                                                                                                               Code   Code
 741 Means of control               1. No 2 Engine room fan damper severely wasted/holed (half of plate             30      -
      (opening, closure of          missing).
      skylights, pumps, etc.
      machinery spaces)
 380 Access / Structure             2. Several external accommodation ladder steps wasted.                          16     -
 610 Lifeboats                      3. Starboard lifeboat F&A "link stoppers" not operational.                      17     -
 1275 Ventilators, air pipes,       4. Forepeak tank air pipe floats not operational (P&S).                         17     -
      casings
 736 Emergency Escape               5. Engine room (bottom plate) EEBD shows no pressure on gauge.                  17     -
      Breathing Device
 989 Decks - cracking               6. Crack in horizontal (main deck) plating in Stbd Fwd corner of No 3 Hold      30     -
                                    and Port Aft corner of No 2 Hold.
982 Beams, frames, floors -         7. Cracking/wastage in Fore/Aft hatch coaming brackets at Fwd P&S               30     -
     corrosion                      corners of No 3 Hold and Aft P&S corners of No 2 Hold.
2550 Maintenance of the ship        8. ISM system does not ensure maintenance of ship and equipment after           18     10
     and equipment                  survey, as evidenced by deficiencies 1,2,3,4,5,6 & 7.

Csae-3 (Port in Australia)
Def.                                                                                                               Act.   ISM
         Type of deficiency                                     Details of deficiency
Code                                                                                                               Code   Code
 743 Fire-dampers                   1. No.4 Engine room fan flap wasted (Port).                                     30      -
 743 Fire-dampers                   2. No.2 Engine room fan flap (Port) crack at connection to spindle.             17      -

Csae-4 (Port in Australia)
Def.                                                                                                               Act.   ISM
          Type of deficiency                                    Details of deficiency
Code                                                                                                               Code   Code
 2041 Operation of GMDSS            1. NAVAREA X & Australian Coastal Navigation Warnings not sighted,              17      -
      equipment                     INMARSAT C incorrectly configured.
 610 Lifeboats                      2. Port & Starboard lifeboat on-load release systems defective                  30     -
 720 Readily availability of fire   3. Main deck fire station lamp defective.                                       17     -
      fighting equipment
 2055 Manuals, instructions, etc.4. SOLAS training manual information on lifeboat on-load release system            16     -
                                 deficient.
2055 Manuals, instructions, etc. 5. Instructions inside lifeboats for correct setting of on-load release            17     -
                                 equipment deficient.

Csae-5 (Port in Australia)
Def.                                                                                                               Act.   ISM
         Type of deficiency                                     Details of deficiency
Code                                                                                                               Code   Code

                                                             Page 1
 696 Maintenance and             1. Port & starboard lifeboat-No record of 5 yearly on load dynamic              18     -
     inspection                  testing of winch brake for davits.
 945 Emergency lighting,         2. Emergency Generator unable to connect to emergency switch-board              30     -
     batteries and switches      automatically.

Csae-6 (Port in Australia)
Def.                                                                                                            Act.   ISM
           Type of deficiency                                 Details of deficiency
Code                                                                                                            Code   Code
 2699 Other (bulk carriers)     1. No record of observed drafts on loading sequence                              17      -
 714 Doors within main vertical 2. Self closing fire doors in main stairwell secured open                        17      -
      zone
 1594 Voyage or passage plan    3. Voyage plan does not take account environmental and special                   17     -
                                considerations in compliance with STCW VIII Annex 2 part 2, SOLAS V R34
 1543 Compass correction log    4. Compass error records not as per STCW                                         16     -
 692 Operational readiness of 5. Port lifeboat on load release safety pin seized                                 17     -
      lifesaving appliances
 699 Other (life-saving)        6. Emergency tillers both lifeboats stowed in lockers no identification of       17     -
                                stowage position
 1499 Other (machinery)         7. Emergency generator defective                                                 30     -
 680 Embarkation                8. Fwd liferaft embarkation gates seized                                         17     -
      arrangements - survival
      craft
 680 Embarkation                9. Fwd liferaft embarkation ladder securing shackles seized                      17     -
      arrangements - survival
      craft
 2099 Other                     10. Pilot ladder embarkation gates seized                                        17     -
      (SOLAS/operational)
 1596 Navigation records        11. No record of navigation activity pilot to berth                              15     -
 799 Other (fire safety)        12. Lub oil tank gauge glass valves gagged open                                  16     -
 899 Other (accident            13. Safety data sheets not available at chemical storage                         17     -
      prevention)
 739 Emergency Fire Pump        14. Emergency fire pump failed to start                                          17     -
 2599 Other (ISM)               15. Company procedures fail to ensure correct maintenance of ship &              18     -
                                equipment objective evidence items 5, 7, 8, 9, 10 & 14

Csae-7 (Port in Australia)
Def.                                                                                                            Act.   ISM
          Type of deficiency                                 Details of deficiency
Code                                                                                                            Code   Code
 610 Lifeboats                   1. Port lifeboat on-load release system defective.                              30      -
 1275 Ventilators, air pipes,    2. After peak ventilator head float fitted permanently in the open position.    17      -
      casings
 650 Lifebuoys                   3. Life buoy light on Port side boat deck not operating.                        17     -
 610 Lifeboats                   4. Port & Stbd lifeboats emergency steering system defective. (Incorrectly      17     -
                                 fitted.)
 610 Lifeboats                   5. Battery terminals for emergency canopy light inside lifeboat                 17     -
                                 corroded/broken.
1499 Other (machinery)           6. No.1 Main engine cooling SW pump leaking from mechanical seal.               17     -
1499 Other (machinery)           7. Heeling tank pump on Stbd side leaking mechanical seal.                      17     -
2550 Maintenance of the ship     8. ISM system does not adequately ensure maintenance of the ship &              18     10
     and equipment               equipment as evidence by deficiencies No.1, 2, 4, 5, 6 & 7

Csae-8 (Port in Australia)
Def.                                                                                                            Act.   ISM
         Type of deficiency                                  Details of deficiency
Code                                                                                                            Code   Code
 743 Fire-dampers                1. Engine room supply fan fire damper broken/wasted starboard aft side.         30      -
 743 Fire-dampers                2. Engine room supply fan fire damper small perforations at edges (Port side    17      -
                                 aft)
 692 Operational readiness of    3. Port and Starboard lifeboats on-load release mechanism defective morse       30     -
     lifesaving appliances       cables (03 pieces)(Inner cables revealed due to cable separation)

2550 Maintenance of the ship     4. Maintenance, testing and inspections of lifeboat on-load release             18     10
     and equipment               mechanisms and engine room supply fan fire dampers unsatisfactory.


Csae-9 (Port in Australia)
Def.                                                                                                            Act.   ISM
         Type of deficiency                                  Details of deficiency
Code                                                                                                            Code   Code

                                                           Page 2
950 Electric equipment in         1. Emergency Generator-defective-unable to transfer power to the                 30     -
     general                      emergency switchboard.
610 Lifeboats                     2. Port lifeboat davit limit switch seized                                       17     -
610 Lifeboats                     3. Port lifeboat canopy light defective                                          17     -
1560 Charts                       4. AUS Chart 515 for next voyage not onboard                                     17     -

Csae-10 (Port in Canada)
Def.                                                                                                              Act.   ISM
          Type of deficiency                                  Details of deficiency
Code                                                                                                              Code   Code
 739 Emergency Fire Pump          1. Emergency Fire Pump not taking suction.                                       17      -
 739 Emergency Fire Pump          2. Instruction posted to operate emergency fire pump incorrect.                  17      -
 1750 Oil/water interface         3. Oily Water Separator, solenoid 3-way valve not operating with 15 ppm          17      -
      detector                    alarm
 699 Other (life-saving)          4. Muster List does not include Jr. 3rd officer, List indicated 19 crews         17     -
                                  instead of 20 crew on board.
 714   Doors within main vertical 5. Several self-closing fire doors in accommodation, steering gear room not      17     -
       zone                       closing properly.
650    Lifebuoys                  6. Self-ignition light with life buoy on stbd boat deck not working              17     -
745    Ventilation                7. Funnel damper wire disconnected. One flap not closing.                        17     -
1550   Lights, shapes, sound-     8. Forward (upper) masthead light not working.                                   17     -
       signals
199    Other 'Certificate)        9. Company Identification Number, different on ISSC & DOC certificate            17     -
1596   Navigation records         10. Passage plan not provided from English Bay anchorage to berth.               99     -
                                  (Action Code 99: Master instructed accordingly)
1599   Other (Navogation)         11. Investigated complain from USCG of marine occurrence when inbound,           99     -
                                  vessel contravened COLREGS in precautionary area of a TSS. Vessel did
                                  not take corrective action when contacted in CVTS.
                                     (Action Code 99: Master instructed accordingly)
 190   Log book/compulsory        12. Log book entries of ship's movement in TSS incomplete.                       99     -
       (entries)                  (Action Code 99: Master instructed accordingly)
2540   Emergency preparedness 13. Class ISM audit to be carried out on Marine occurrence and emergency             18     8
                                  preparedness

Csae-11 (Port in China)
Def.                                                                                                              Act.   ISM
         Type of deficiency                                   Details of deficiency
Code                                                                                                              Code   Code
 111 Cargo Ship Safety            1. The last two inspections of the outside of the ship's bottom took place       18      -
      Construction (including     on" not entry in SC cert.
      Exemption)
 715 Fire detection               2. Smoke/Heat detector and fire alarm in E/G room N/A                            30     -
 960 Means of escape              3. Escape trunk to E/Room not the same fire integrity (partly fire insulation    30     -
                                  for bulkhead to S/G room not provided)
710    Fire prevention            4. Cable duct on E/G room floor to A/C room not meet fire integrity.             30     -
710    Fire prevention            5. Cable duct on bulkhead of E/G room to corridor not meet fire integrity.       30     -
1899   Other (Oil tankers)        6. ERS agreement N/A on board.                                                   17     -
1570   Nautical publications      7. IAMSAR vol III not up to date.                                                15     -
945    Emergency lighting,        8. CO2 room illumination out of order and not covered by emcy-light.             17     -
       batteries and switches

Csae-12 (Port in China)
Def.                                                                                                              Act.   ISM
         Type of deficiency                                   Details of deficiency
Code                                                                                                              Code   Code
 710 Fire prevention             1. A hole (Dia.23cm) found on the bulkhead of E.C.C.R behind main                 30      -
                                 switchboard.
1470   Insulation wetted through 2. Thermal insulation of manhole cover for F.O.SETT. TK not found.                16     -
       (oil)
1470   Insulation wetted through 3. Thermal insulation of manhole cover for F.O.SERV.TK not found.                 16     -
       (oil)
1460   Guards/fencing around     4. Anti-slipperry floor around emergency steering gear position not found.        16     -
       dangerous machinery
       parts
1275   Ventilators, air pipes,   5. Vent cover to CO2 room seized.                                                 16     -
       casings
1275   Ventilators, air pipes,   6. Vent cover to fire station room seized.                                        16     -
       casings
1275   Ventilators, air pipes,   7. Multi.Drain plugs of D.O & F.O tank air vent missing.                          16     -
       casings

                                                            Page 3
945 Emergency lighting,           8. All emergency lights in engine room not marked clearly.                       16     -
     batteries and switches
1010 General alarm                9. Manually operated call point at paint locker area (include near exit) not     30     -
                                  provided.
1010 General alarm                10. Manually operated call point at CO2 room area (include near exit) not        30     -
                                  provided.
1010 General alarm                11. Manually operated call point at emergency generator room area (include       30     -
                                  near exit) not provided.
1010 General alarm                12. Manually operated call point at galley room area (include near exit) not     30     -
                                  provided.

Csae-13 (Port in China)
Def.                                                                                                              Act.   ISM
           Type of deficiency                                  Details of deficiency
Code                                                                                                              Code   Code
 610 Lifeboats                    1. Falls of lifeboats not renew over 5 years                                     15      -
 2099 Other                       2. Not carried out pre-arrival of xxxxxxxx check for navigational equipments     -       -
      (SOLAS/operational)         & engines
 1570 Nautical publications       3. NP 286(1) not up to date                                                      -      -
 1710 Oil record book             4. Collection of oil residues entries not made weekly in oil record book         -      -
 740 Fire pumps                   5. The packing of main fire pump leaking                                         -      -
 1499 Other (machinery)           6. The piping & fittings for Aft S/T P.A.P. system leaking                       15     -
 1430 Auxiliary engine            7. Insulation of No.1 & No.2 A/E Exh. Outlet pipe missing                        15     -
 1435 Gauges, thermometers,       8. One Exh. Temp. gauge for No.2 A/E damaged                                     15     -
      etc
 950 Electric equipment in        9. Insulation carpets not provided in front & rear of Emergency switch board     -      -
      general
 1499 Other (machinery)           10. Water level gauge for boiler leaking                                         15     -
 1730 Oil filtering equipment     11. O.W.S. can not work normally no sample water in sample pipe supply           -      -
 2545 Reports and analysis of     12. Deficiencies of last PSC inspection not rectified as requirements            15     9
      non-conformities,
      accidents and hazardous
      occurrences

Csae-14 (Port in China)
Def.                                                                                                              Act.   ISM
         Type of deficiency                                    Details of deficiency
Code                                                                                                              Code   Code
 715 Fire detection               1. Fire detector in paint room not found                                         16      -
 715 Fire detection               2. Fire detector in CO2 room not found                                           16      -
 715 Fire detection               3. Fire detector in fire station room not found                                  16      -
 715 Fire detection               4. Fire detector in E/G room not found                                           16      -
 715 Fire detection               5. Fire detector in galley room not found                                        16      -
 715 Fire detection               6. Fire detector in S/G & Emerge. Fire pump room not found                       30      -
 1010 General alarm               7. Manually operated call point in the Captain room deck's corridor found        16      -
                                  more than 20m from next manually operated call point
1010   General alarm              8. Manually operated call point at CO2 room area (including near exit) not       30     -
                                  provided.
1010   General alarm              9. Manually operated call point at E/G room area (including near exit) not       30     -
                                  found
1010   General alarm              10. Manually operated call point at Galley Room area (including near exit)       30     -
                                  not provided.
1010   General alarm              11. Manually operated call point at paint room area (including near exit) not    30     -
                                  provided.
1010   General alarm              12. Manually operated call point at S/G & emerge. fire pump Room area            30     -
                                  (including near exit) not provided.
1623   MF/HF radio installation 13. MF/HF NBDP printer malfunction                                                 15     -
1592   Use of the automatic pilot 14. Off course alarm of auto pilot malfunction                                   16     -
699    Other (life-saving)        15. IAMSAR manual vol III not up to date                                         16     -
1551   Signaling lamp             16. ALDIS lamp independent battery N/A                                           16     -
755    Fire control plan - all    17. Fire main isolation valve not identified in fire control plan                18     -
       ships

Csae-15 (Port in Germany)
Def.                                                                                                              Act.   ISM
         Type of deficiency                                    Details of deficiency
Code                                                                                                              Code   Code
 1430 Auxiliary engine            21. Auxiliary engines with leakages (water, oil etc).                            30      -



                                                             Page 4
1310 Ropes, wires              1. Minimum three mooring lines damaged and to be changed. One rope             17   -
                               already broken today. See also deficiencies from last PSC report. Company
                               takes no action and ignored everything.
2330 Garbage record book       2. Only copy pages used due to garbage record book missing.                    17   -
1543 Compass correction log    3. Compass correction log not properly filled.                                 17   -
1699 Other (radio)             4. Several ITU lists expired.                                                  17   -
1599 Other (navigation)        5. One binocular not properly adjustable.                                      17   -
613 Stowage of lifeboats       6. Limit switch of both lifeboat davits not working                            17   -
850 Structural features (ship) 7. Limit switch runner of provision crane out of order.                        17   -
950 Electric equipment in      8. Several decks lights all over the vessel damaged and/or not properly        17   -
     general                   maintained or fixed.
950 Electric equipment in      9. Several electric cables/wires around the vessel not properly fixed and/or   17   -
     general                   watertight.
1430 Auxiliary engine          10. Damaged auxiliary engine on poop deck not properly lashed. Stack           17   -
                               weight of deck to be checked by RO.
988 Decks - corrosion          11. Superstructure holed on stb. side poop deck. To be investigated by         30   -
                               class society.
745 Ventilation                12. Frame of ventilation flaps in front of bridge totally wasted of and flap   30   -
                               lying beside. Several butterflies missing on another flaps. To be repaired
                               under supervision of class society.
745 Ventilation                13. Several fire flaps/ventilation heads around the vessel not properly        30   -
                               closable due to corrosion and/or rubber damaged.
1270 Doors                     14. Several doors on main and poop deck not properly closable. To be           30   -
                               repaired under supervision of class society.
1230 Railing, cat walks        15. Rail Stbs side damaged due to wasted of from station. See also             30   -
                               deficiencies from last PSC report. Company ignored all.
1230 Railing, cat walks        16. Several protection chains missing and/or not properly fixed.               17   -
1499 Other (machinery)         17. Fuel tank heating system out of order.                                     17   -
1499 Other (machinery)         18. Boiler water level indicator in bad condition.                             17   -
799 Other (fire safety)        19. Cable penetration for power pack cables to engine room not as required.    30   -
1430 Auxiliary engine          19. Auxiliary engines with missing/damaged insulation of exhaust duct.         17   -
1430 Auxiliary engine          20. Auxiliary engines with broken instruments (e.g. manometers etc.)           17   -
1721 Retention of oil on board 22. About 95 cm oil in E/R cofferdam. Oil to be discharged and cofferdam       30   -
                               cleaned.
1499 Other (machinery)         23. Water in pipe duct to be discharged.                                       17   -
1410 Propulsion main engine    24. Local thermometers partly missing at cooling water outlets. See last       17   -
                               PSC report.
1410 Propulsion main engine    25. Compensator on exhaust line of ME broken.                                  30   -
1499 Other (machinery)         26. 'Pipe system in way of cooling-, bilge- and ballast pumps in very bad      17   -
                               condition (corrosion).
1430 Auxiliary engine          27. Auxiliary engine cooling water pump missing.                               17   -
899 Other (accident            28. Floor plates in engine room and aux eng. room to be fixed.                 17   -
     prevention)
956 Gangway, accommodation 29. Port side gangway pedestal and steps partly cracked.                           17   -
     ladder
2550 Maintenance of the ship 30. Due to the amount and nature of the above mentioned deficiencies             30   10
     and equipment             additional external audit by flag state or RO required.
2515 Company responsibility    31. The company is responsible for ensuring that adequate resources and        30   3
     and authority             shore based support are provided. Due to the amount and nature of
                               deficiencies it is obviously that the SMS is not properly implemented.
                               Additional external audit by flag state or RO
2599 Other (ISM)               32. Due to insufficient follow up action taken and ignorance of deficiencies   30   -
                               additional audit by flag state or RO required
745 Ventilation                33. Ventilation duct to the engine port side funnel deck holed. To be          30   -
                               repaired under supervision of class.
710 Fire prevention            34. Door funnel to deck port side not closable. To be repaired under           30   -
                               supervision of class.
710 Fire prevention            35. Door in engine room to boiler room not closable. To be repaired under      30   -
                               supervision of class.
713 Main vertical zone         36. Welding in bulkhead engine/aux. engine room missing. To be investigated    30   -
                               by class society and repaired under supervision of class.
710 Fire prevention            37. Door in purifier room not closable. To be repaired under supervision of    30   -
                               class.
1286 Scuppers, inlets and      38. Overboard sewage system valve in engine room port side damaged. To         30   -
     discharges                be repaired under supervision of class.
1499 Other (machinery)         39. Scavenge air drain tank full. To be discharged.                            17   -
1499 Other (machinery)         40. Valve at scavenge air drain tank damaged.                                  17   -

                                                         Page 5
Csae-16 (Port in India.)
Def.                                                                                                             Act.   ISM
          Type of deficiency                                     Details of deficiency
Code                                                                                                             Code   Code
 745 Ventilation                   1.CO2 Room: Exhaust fan defective & Exhaust vent fire mesh wasted              30      -
 1735 Pumping, piping and          2.Oily Bilge Separator Pump not developing vacuum & sensor (15 PPM) not        30      -
      discharge arrangements       operational
      of oil tankers
 714 Doors within main vertical    3. 3 Nos. self closing assemblies in E/Room defective.                         30     -
      zone
 1499 Other (machinery)            4.   Engine control room A/C not operational.                                  17     -
 650 Lifebuoys                     5.   L/Buoy light housing assembly on boat deck worn & wasted                  17     -
 2599 Other (ISM)                  6.   Hot work in progress on Aft deck, without valid hot work permit.          17     7
 1570 Nautical publications        7.   List of call sign & numerical identities (ITU) expired .                  18     -
 999 Other (stability/structure)   8.   Cable tray assembly on stern & anchor light excessively wasted            17     -

Csae-17 (Port in Korea.)
Def.                                                                                                             Act.   ISM
         Type of deficiency                                      Details of deficiency
Code                                                                                                             Code   Code
 2525 Masters responsibility       1. Master not pointed out designated person when he is not on board.           30      5
      and authority                Special audit needed about ISM

Csae-18 (Port in Spain)
Def.                                                                                                             Act.   ISM
            Type of deficiency                                  Details of deficiency
Code                                                                                                             Code   Code
 746 Jacketed piping system        1. D/G No.2 permanent F.O. leak high level alarm. Major fuel leakage from      47      -
      for high pressure fuel lines fuel feed pump ( seal driven device ). ( Act. Code 47: Act. Code 47: Class
                                   Report required before departure)
 1099 Other (alarms)               2. E/R aft bilge HL alarm permanent set up. (Act. Code 47: Class Report        47     -
                                   required before departure.)
 1060 Machinery controls alarm 3. Several machinery control alarms set up, No.1 main air compressor               47     -
                                   abnormal, waste oil serv. Tank low level alarm, M/E Cyl. No.2 & 3 Cool. F/V
                                   out HT. (Act. Code 47: Class Report required before departure)
 1420 Cleanliness of engine        4. Cleanliness of engine room to be improved, M/E, M/E L.O. pump tray,         99     -
      room                         F.O. purifier space, etc.
 1470 Insulation wetted through 5. M/E fuel valve high pressure pipe damaged to be renewed before                 17     -
      (oil)                        departure
 1499 Other (machinery)            6. Evaporator ejector sea water pump leaking by seal.                          16     -
 2550 Maintenance of the ship 7. E/R maintenance to be improved. Instructions and procedures for that to          18     10
      and equipment                be implemented.

Csae-19 (Port in U.K.)
Def.                                                                                                             Act.   ISM
          Type of deficiency                                     Details of deficiency
Code                                                                                                             Code   Code
 1560 Charts                       1.   Missing / expired                                                         30      -
 1570 Nautical publications        2.   Expired                                                                   17      -
 1594 Voyage or passage plan       3.   Not as required                                                           30      -
 2040 Bridge operation             4.   Lack of familiarity                                                       17      -
 2043 Monitoring of voyage or      5.   Not as required                                                           17      -
      passage plan
 695 On board training and         6. Lack of information, Training manual to be ship specific                    16     -
      instructions
 2530 Resources and personnel      7. Incomplete                                                                  30     6
 2525 Masters responsibility       8. Master responsibility                                                       17     5
      and authority
 650 Lifebuoys                     9. Missing, Additional lifebuoy required                                       17     -

Csae-20 (Port in U.S.A..)
Def.                                                                                                             Act.   ISM
         Type of deficiency                                      Details of deficiency
Code                                                                                                             Code   Code




                                                               Page 6
 750 Fire prevention            1. The remote operated valves for both diesel oil service tanks, the heavy        30     -
                                fuel oil service tank and the heavy fuel oil settling tank were found blocked
                                open and unable to operate as designed in case of a fire. The No.2 ship's
                                service generator was operating and being supplied by the heavy duel oil
                                service tank. The crew reported that the blocks had been in place fro an
                                unknown period of time. Prove proper operation of the remotely operated
                                valves to the satisfaction of the classification society acting on behalf of
                                the Administration.

Csae-21 (Port in U.S.A..)
Def.                                                                                                             Act.   ISM
         Type of deficiency                                 Details of deficiency
Code                                                                                                             Code   Code
 1499 Other (Prop. & Aux.       1. It was found that the remote fuel shut-off valves for the Diesel Oil           30      -
      Machinery)                Service Tank (supplies the generators), Fuel Oil Service Tank (supplies the
                                generators and boiler) and Cylinder Oil Storage Tank (supplies the main
                                engine) were each effectively bypassed with a piece of 1/2 inch diameter
                                dowel rod, preventing those tanks from being remotely shut in the event of
                                fire. Upon expanded examination, the PSCO attempted to remove the
                                dowel rod, that bypassed the Diesel Oil Service Tank fuel shut-off, but was
                                unable to do so. The valve had already closed, but was still in the open
                                position and providing fuel to the No.3 Ship Service Generator. All remote
                                fuel shut-off system were successfully tested and approved in working
                                order by class, when the ship was in a scheduled dry dock period. The
                                vessel has not record from the company or class having knowledge or
                                approving this condition. The vessel is to repair the valves and prove
                                proper operation to the attending classification society prior to movement.
 991 Survey Report File         1. Inset in hull (above waterline, starboard bow) along deck 7 between Fr.       17ac    -
                                182 - 186, resulting in buckling of at least two frames. Inset and frame
                                damage decreases structural integrity of hull. No documentation was able
                                to be produced regarding Class notification and approval.
                                            ( Def. Code, a: to the satisfaction of class/RO/RSO, c:
                                the satisfaction of Coast Guard )
1400 Propulsion & aux.          2. Temporary patch on weld to seal a leak of air cooler outlet line. No          17ac    -
     Machinery                  documentation was able to be produced regarding Class notification and
                                approval.
 710 Fire prevention            3. Multiple explosion proof lights in the engine room, specifically around the   70ac    -
                                purifier flat, have cracked and/or holed casings. This does not provide
                                adequate fire protection as intended by design.           (Def. Code
                                70: Rectify deficiencies prior to next U.S. port after sailing foreign )
2500 ISM related deficiencies   4. Due to the above deficiencies, and lack of Class and company notification     70bc    9
                                of the same, the vessel's SMS procedure are not being followed and
                                possibly inadequate. An audit of vessel's safety management system is
                                recommended. (Def. Code b: To the satisfaction of administration )




                                                          Page 7

				
DOCUMENT INFO