Notched Nestable Corrugated Steel               tools is supplied with each order of Armtec                    staggered by using 5 and 4 corrugation
Pipe consists of matching half-round seg-       Nestable Pipe.                                                 sections at the ends.
ments of corrugated steel which, when           BASIC ASSEMBLY: When assembling                                All laps should be in the direction of flow.
assembled, become lengths of full-round         Armtec Nestable Pipe, the bottom 9 corru-                      The half sections will be drawn together at
corrugated steel pipe. Standard segments        gation sections are placed into position                       the notched seams with a bending bar and
are 610 mm long.                                with each succeeding section overlapping                       the appropriate fastener inserted through
This pipe is manufactured in diameters          the previous one by one corrugation The                        the matching holes. There are 2 fasteners
ranging from 300 mm to 2,000 mm and in          top 9 corrugation sections are                                 every 600 mm on each side.
wall thickness from 1.6 mm to 4.2 mm. The
corrugated sections and fasteners are zinc
                                                Minimum Steel Thickness for CS-600
galvanized to Z 610 culvert standards. A 50        DIAMETER              AREA                   MAXIMUM HEIGHT OF COVER IN METRES
                                                                             2
mm notch is factory punched along one                 mm                   m            3       4.6  6.1   7.6   9.2  10.7 12.2 13.7
edge of every sheet.                                  300                  .07         1.6      1.6  1.6   1.6   1.6   2.0   2.0  2.0
                                                      400                 .13          1.6      1.6  1.6   2.0   2.0   2.0   2.0  2.8
Notched nestable pipe is used for culverts,           450                 .16          1.6      1.6  1.6   2.0   2.0   2.0   2.0  2.8
storm drains and other drainage applica-              500                 .20          1.6      1.6  1.6   2.0   2.0   2.0   2.8  2.8
tions in locations where the shipping of              600                 .28          1.6      1.6  2.0   2.0   2.0   2.8   2.8  2.8
factory made pipe would be uneconomical.               700                .38          2.0      2.0  2.0   2.0   2.8   2.8   2.8  2.8
Remote locations and overseas projects                800                 .50          2.0      2.0  2.0   2.0   2.8   2.8   2.8  2.8
would be examples of typical locations.               900                 .64          2.0      2.0  2.0   2.8   2.8   2.8   3.5  3.5
                                                      1000                .79          2.0      2.0  2.8   2.8   2.8   3.5   3.5  3.5
Due to the segmental layout the product is
                                                      1200                1.13         2.8      2.8  2.8   2.8   3.5   3.5   3.5  4.2
shipped disassembled and “nested” allow-
                                                      1400                1.54         2.8      2.8  2.8   3.5   3.5   3.5   3.5  4.2
ing large quantities to be shipped in a rel-                                                                                 4.2
                                                      1600                2.01         3.5      3.5  3.5   3.5   3.5   4.2
atively small volume.                                 1800                             3.5      2.8  3.5   3.5   4.2   4.2
                                                                          2.54
Nestable Pipe also offers a fast economical           2000                3.14         3.5      3.5  4.2   4.2   4.2
solution to contractors and owners who          Note: 1. 300 mm to 1200 mm diameter, Minimum cover = 300 mm
                                                        1400 mm to 2000 mm diameter, Minimum cover = 500 mm
are looking for a strong casing that could             2. Structures must be backfilled with well compacted granular material to a minimum of 95% Standard Proctor Density
be placed around an already installed utili-
ty line. This can be done easily without dis-   Approximate Weights kg/m
rupting the line to be encased. Whether for        DIAMETER                                              WALL THICKNESS mm
culverts, storm drains or casing, properly            mm                       1.6                2.0           2.8        3.5                                4.2
compacted backfill around the nestable                 300                     15                 19             26         32                                 38
corrugated pipe is required for developing             400                     20                 25             34         42                                 50
ring strength.                                         450                     23                 29             38         47                                 57
                                                       500                     25                 32             43         53                                 63
FASTENING METHODS: There are three                     600                     29                 37             51         63                                 76
standard methods used in attaching the                 700                     34                 43             59         73                                 88
half-round pipe segments together. The                 800                     39                 49             68         84                                100
method used is dictated by the pipe diam-              900                     44                 56             77         95                                113
eter. The stitch type (#1 or #2) will be sup-         1000                     49                  61            85        105                                126
plied up to 800 mm in pipe diameter and               1200                     59                 74            102        126                                151
hook and eye bolts will be supplied for 900           1400                     69                 85            119        147                                176
mm and over pipe diameter.                            1600                     78                 98            137        168                                202
                                                      1800                     88                 110           153        188                                226
TOOLS SUPPLIED: One set of assembly                   2000                     98                 122           170        210                                252


                                                            Head Office: 370 Speedvale Ave. W., P.O. Box 3000, Guelph, Ontario N1H 6P2
                                                            www.armtec.com
                                                            Sales Offices:
                                                            Nanaimo, Prince George, Langley, Edmonton, Calgary, Lethbridge, Saskatoon,
                                                            Winnipeg, Thunder Bay, Sudbury, Guelph, Toronto, Peterborough, Chesterville,
                                                            Forest, Orangeville, Comber, Montreal, Quebec City, St. Clet, Sackville, Truro,
                                                            Summerside, Bishop’s Falls and St. John’s.                         NP/BP/30C/0607

								
To top