MEDICA / COMPAMED 2008 -- Exhibitors & Products 2008: Exhibitor ...
http://www.medica.de/kati-cgi/kati/vis/custom/ext2/print_page.cgi?url=h...
Exhibitors & Products 2008: Exhibitor Data Sheet
Copy current exhibitor to MyOrganizer
Shivani Scientific Industries (P) Ltd.
News Basic Data Company Profile
Products Trademarks
Dates Floor Plan
EXHIBITOR Shivani Scientific Industries (P) Ltd. Hall 12 / A02 26A Raju Industrial Estate, Penkar Pada Road 401 104 Mira, Mumbai India Phone: +91 22 28456768/69/70 Fax: +91 22 28456766 http://www.shivaniscientific.com fornax@shivaniscientific.com Manufacturers OEM
Floor Plan
1 of 1
11/17/2008 8:38 PM
! "
! "# $
Shivani Scientific Industries (P) Ltd has vast experience of more than 20 years of designing and building pharmaceutical Laboratories as per WHO-GMP norms with stringent requirement of sterility. The same experience has helped us to fulfill the demanding needs of to-days IVF Labs. A new Lab means start contacting designers, architects, sellers, resellers, vendors, suppliers, agents, distributors to initiate slow, long and laborious process of discussing dates and negotiating rates. This, you will agree, will further eat into your most precious commodity “Time”. Alternatively you have the easier and simpler option: Contact US.
THE ACTION PLAN
For setting up of your IVF facility
SITE SURVEY & DESIGNING MAT SELECTION ENVIRONMENTAL ENGINEERING EQUIPMENT INSTALLATION VALIDATION & CALIBRATION
Turnkey Projects for IVF Labs.
START
BUDGET AND OVERALL PLANNING
RISK ANALYSIS / STAFF EDUCATION & TRAINING
PREPARATION OF MARKETING OF CLINIC
FINISH
EQUIPMENT SELECTION AND ORDER
PROCUREMENT / LOGISTICS INSPECTION & SHIPMENT
CONSUMABLES AND MEDIA
3D Lab design / 3 D Walk through
We offer State of the Art computer modeling to visualize your Lab either in 3D or 3D Walk through, even before your lab is ready.
Air Quality evaluation and improvement
We have capability to thoroughly evaluate Air quality on existing Lab and recommend appropriate steps to improve the same. It varies from HVAC inspection to microbial air sampling.
L WASH M IUI LAB 15'11" x 7' 1 11 12 13
Customised Video Processing
All modern equipments comes with all provision of image processing which is very well utilized by our Combination of hardware camera selection and software selection. Multiple Camera inputs can be synthesised in one system to have better recording and processing.
Hands on training for Lab Staff
We offers comprehensive hands on training in collaboration with Maharashtra Animal & Fishery Sciences University to Lab Staff..
TOILET 4' x 7' SEMEN COLLECTION ROOM 7'11" x 7'
Embryology Services
We provide assistance in providing complete embryology services from Ovum Pick-up to embryo transfer. Qualified and experienced team of clinicians and embryologists are selected to provide these services.
Annual Maintenance of IVF Lab Equipments
We undertake Annual Maintenance Contracts for IVF Labs with the support of its highly qualified team of Engineers. We also cater to calibration contracts with our highly accurate calibration equipments.
DOCTOR'S CHANGE ROOM 7' x 7'
DOCTOR'S CONFERENCE ROOM 15' x 11'
WASH WASH
O.T. 15'11" x 12'10"
15
14
16
8
7
17 9 IVF LAB 15' x 12'10"
PATIENT CHANGE ROOM 7' x 7'
6 18 3
11
2
5 N
1 20
Shivani Scientific Industries (P) Ltd
26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com ssipl@bom5.vsnl.net.in
10 19 K RECEPTION 12'3" x 11'6" M RECOVERY ROOM 24'11" x 9' N K K UTILITY 6' x 9' I 4 J
Tel - + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 Fax - + 91 22 2845 7140 + 91 22 2845 6766
We make it possible
MAIN ENTRANCE
Technical Specification
Temperature Management Digital programming via microprocessor control in 1.0 C increments.measurement of temperature in chamber via digital sensor. Over temperature protection system independent of microprocessor control. Range Control Stability uniformity 2 °C above ambient to 42 °C ± 1 °C ± 1 °C ± 1 °C Centrifugation Details Max rotational speed Rotational speed range Relative centrifugal force Acceleration and braking Rotor capacity Choice of tubes Electrical supply Operating Voltage 100 or 220 Power consumption 2200 RPM 300 to 2200 RPM 800 g max programmable 8 x 15 ml 6ml, 14ml, 15ml
Spermfuge
Temperature Regulated Centrifuge
120 Volts 60 Hz 240 Volts 50 Hz 450 watts max
specifications subject to change without notice
Ordering information
Spermfuge SF 800 Spermfuge SF 800 100 120 Volts 60 Hz order code FX 1055 220 240 Volts 50 Hz order code FX 1056
SF 800
470 mm
Dimensions
385 mm
C Q
Traceability calibration in accordance with national and international standards, NIST USA
For more details go to
www.shivaniscientific.com
Individual and expressive quality control certificate
Shivani Scientific Industries (P) Ltd
26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com ssipl@bom5.vsnl.net.in
Distributor
Tel - + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 Fax - + 91 22 2845 7140 + 91 22 2845 6766
220 mm
We make it possible
SF 800
Spermfuge
Temperature Regulated Centrifuge
SF 800
Spermfuge
Temperature Regulated Centrifuge
ACCELERATION AND BRAKING
An adjustable brake is provided to prevent the rotor from stopping too quickly at the end of run which might cause disturb to the firmly formed pellet. One can select 3 mode in acceleration and braking, slow medium and to fast can be given on screen.
SF 800
CONCEPT
SPERMFUGE is an improvised centrifuge, dedicated totally for elevating the total motile sperm recovery from the parent semen sample, by controlling/maintaining the main parameter of “Temperature” thus aimed at Enhancing the ART results. The instrument has been designed to regulate and subsequently maintain the “Critical” inner chamber temperature before, after and during centrifugation. Maintenance of this critical temperature throughout the entire sperm processing procedure helps the sperm maintain their peak motility and enhanced linearity. The two of the most vital parameters which act as a yard stick to gauge the effectiveness of an ideal sperm wash. The existing dependency on RPM will be eliminated by on screen g-force selection.
OPERATING SECURITY G FORCE
The exact indication of g-force helps the ideal sperm pellet formation by subjecting the sperm to an exact and precise amount of g-force unlike other Centrifuges where g-force is subject to RPM and the tube size. Now a days centrifugation speeds are never reported in RPM as those numbers are not useful for any one wanting to reproduce the method. (Being dependent Rotor radius.) The Vision port in the lead at the center helps to confirm rotational speed with a stroboscopic device. The safety interlock in the lead prevents accidental opening once the Rotor is operational. The maximum RCF is 800g which prevents accidental damage to the sperm.
TEMPERATURE AND CENTRIFUGATION
The heating range of SPERMFUGE's chamber is from 2°C above ambient to 42°C. The intelligent control system does not allow the centrifugation to commence till the set temperature is attained. However, one does have the option to commence the centrifugation without chamber heating and to commence the chamber heating without centrifugation.
DESIGN
The SPERMFUGE has been designed after taking into consideration detailed cellular physiological demands, locomotion kinetics and pooling together ideal suggestions, opinions, ideas and propositions of numerous Andrologists and Embryologists and other professionals in the field of Human Reproduction. The SPERMFUGE with its Temperature controlled chamber ( room temperature to 42° C), programmable microprocessor based controls, multiple tube selection, accurate g-force selection, independent centrifugation and/or heating selection and other added advantages make it an ideal state of the art instrument for use in an ART laboratory.
INTELLIGENT CONTROL SYSTEM
State of the art microcontroller with optomagnetic encoder provides intelligent control system. Digital programming via microprocessor control for various parameters including temperature, RCF and time. The parameters are displayed on four line LCD display .
MULTIPLE PROGRAMS
The SPERMFUGE facilitates user selectable 9 programs for different applications and also for different set of protocols as standardized by various clinics, laboratories and regulatry bodies. The user can select RCF, RPM, Tube Size, temperature, time for each program by a digital encoder.
ROTOR HEAD AND TUBE SELECTION
SPERMFUGE has a swing out rotor head to accommodate 8 tubes maximum of 15 ml. The Sperm Fuge can accommodate 6ml Tubes (Falcon 2003), 14 ml Tubes (Falcon 2001) and 15 ml Tubes (Falcon 2095). The tube selection can be done on screen with the help of the encoder, which ensures an exact g-force selection.
MAINTENANCE
The SPERMFUGE is virtually maintenance free since it utilizes brushless drive motor. The motor is extremely smooth even during running at the maximum speed. The motor is electrically controlled during the acceleration and breaking with smoothness.
Technical Specification
Temperature Management Digital programming by microprocessor control in increments of 0.1 °C. Measurement of temperature in tube holder via digital sensor. Over temperature protection system independent of microprocessor control. Range Control Stability uniformity 2°C above ambient to 40°C ± 0.2°C ± 0.1°C ± 0.2°C Indications and signals Visual indications power on/off Target temperature sustained /out of range Battery charged /discharged/low. Electrical supply Operating Voltage 100 120 Volts 60 Hz or 220 240 Volts 50 Hz Power consumption 95 watts max
Mobile Nest
Portable Test Tube Warmer
specifications subject to change without notice
Ordering information
Mobile nest MN 430 Mobile nest MN 430 Spare Tubenest 100 120 Volts 60 Hz order code FX 3035 220 240 Volts 50 Hz order code FX 3036 order code FX 3037
MN 430
120 mm
Dimensions
300 mm 35 mm
180 mm
C Q
Traceability calibration in accordance with national and international standards, NIST USA
For more details go to
www.shivaniscientific.com
Individual and expressive quality control certificate
Shivani Scientific Industries (P) Ltd
26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com ssipl@bom5.vsnl.net.in
Distributor
Tel - + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 Fax - + 91 22 2845 7140 + 91 22 2845 6766
210 mm
We make it possible
MN 430
Mobile Nest
Portable Test Tube Warmer
Mobile Nest
Portable Test Tube Warmer
HOW SAFE ARE PREHEATED TUBES?
The Falcon Tubes (2001) pre heated by regular Test Tube Warmer loses its temperature in less than 15 seconds the moment it is out of the heating block and the tube reaches near to the room temperature, thus increasing the risk of thermal shock to the oocytes during aspiration. Mobile Nest is Portable Test Tube Warmer with it's own Internal rechargeable Battery which gives immense mobility and at the same time maintains precise temperature.
MN 430
CONCEPT
Human oocytes are extremely sensitive to transient cooling 'IN VITRO' and modest reductions in Temperature can cause irreversible disruption of the meiotic spindle, with possible chromosome dispersal. Embryos subjected to such heat shocks have high proportion of chromosomal abnormalities and this may contribute to the high rates of pre-clinical and spontaneous abortion. Therefore, temperature control is of paramount importance and should not be compromised in any way right from Ovum pick up (OPU) till Embryo transfer (ET).
Preheated Tube loses temp. very fast
Tube Nest rock steady at 37°C
Take Gametes and Embryos anywhere
DESIGN
This is a handheld device with Li-ion rechargable battery. It is equipped with heating element, Digital sensor, microcontroller, nonvolatile memory and LED indicators. When placed on base station, it gets conected electrically by its contacts. These contacts help base station and the mobile device communicates with each other and also charge the battery. The mobile nest when in mobile mode continuously monitors the temperature with a 14 bit accuracy, corrects it several times a second. This yields a rock steady temperature profile even in varying surroundings. The mobile nest continues to log for the power consumption index and temperature abnormalities. These are downloaded to the base station when the nest is docked. With monitoring and reporting features the user can be assured about the mobile nest working accurately at every step. A transparent window facilitates easy viewing of the follicular fluid.
INTELLIGENT CONTROL SYSTEM
State of the art microcontroller with optomagnetic encoder provides intelligent control system. Digital programming via microprocessor control for various parameters including temperature and power status. The parameters are displayed on four line LCD display .
UNIQUE PORTABILITY
This Tubenest has been designed keeping in mind its portable nature. The rechargeable battery is capable of running for 30 minutes at a stretch before it indicates low battery level. The unique locking mechanism for tube allows Embryologist to pour the aspirated follicular fluid into petridish for oocyte scanning very easily. Easy grip design allows convenient handling and battery time facilitates free movement in the LAB and OT.
Transparent Cover Viewing Slot Aluminum Body LED indicators
14 ml Test Tube
Tube temp 38 36 34 32 30 Room 28 temp 26 24 oC
37
fall of temp. of 2OC
OPERATING SECURITY
To ensure maximum oocyte survival without quality compromise, this unit has various safety features. The Nest Tube has RED LED INDICATOR which flashes when battery is weak. When the Nest is replaced in the Base Station it checks the log and indicates any overshoots. Moreover the Nest has a safety over temperature cut out.
Digital Sensor PCB Li-ion Battery
0
10 20 30
Seconds
TECHNICAL SPECIFICATION
Blower-German make Pre Filter Hepa Filter VOC Filter: Unit capacity: Mounting: Power consumption: Filter replacement Electrical supply : : : : : : : : Backward impeller type Synthetic PU washable Efficiency 99.97% @ 0.3 microns Unique blend of activated carbon and alumina 350 CFM To be done outside VF Lab on any Wall 90 Watts maximum as per auto indication 100/110 volts OR 220/240 volts 50/60 Hz
Lab Guard
Positive Pressure System
specifications subject to change without notice
Ordering information
Lab Guard LG 300 Lab Guard LG 300 Spare Filter Set Return Blower 100 120 Volts 60 Hz order code 220 240 Volts 50 Hz order code order code order code FX FX FX Fx 2045 2046 2047 2048
LG 300
Dimensions
590 mm 470 mm
C Q
Traceability calibration in accordance with national and international standards, NIST USA
For more details go to
www.shivaniscientific.com
Individual and expressive quality control certificate
Shivani Scientific Industries (P) Ltd
26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com ssipl@bom5.vsnl.net.in
Distributor
Tel - + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 Fax - + 91 22 2845 7140 + 91 22 2845 6766
800 mm
We make it possible
Guard Lab Pressure System Positive
LAB GUARD
Positive Pressure System
DESIGN
The LAB+GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters out air and gas contaminant thus by giving most suitable air for gametes and embryos. LAB+GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum level.
CONCEPT
The LAB+GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly. The positive pressure system uses the basic principle of “Over Pressure or positive pressure in a room which restricts the entry of outside air”. This is achieved by absorbing the circulating air outside the IVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs.
Return Blower
LAB GUARD
LG 300
IVF LAB
UTILITY ROOM
Fresh Air
OPERATING SECURITY
Every care has been taken in designing to make sure that air absorbed is thoroughly cleaned for contaminants and to reduce bacterial count in IVF Lab. The LAB+GUARD design also facilitates introduction of fresh air into the air circuit which gives maximum safety from Carbon dioxide released into the IVF Lab by CO2 Incubators and also it protects embryologists from gas mixtures released on work stations.
RETURN BLOWER
The return blower is utilised to circulate back the air of IVF lab to room where LAB+GUARD has been fitted.
REDUCES CFU, REDUCES VOC
The unique design and the concept of LAB+GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB+GUARD not only protects embryos and gammas but also protects embryologists who is the most affected otherwise.
UPGRADING, EXPANDING OR SETTING UP NEW IVF LAB?
The LAB+GUARD team helps you in evaluation of possibilities to improve air quality in your lab. If you are upgrading, expanding or setting up new lab contact us for technical assistance.
CHANGE FILTERS AS PER USAGE
The LAB+GUARD also houses a unique automatic indication system whereby the user is informed when to change the filters, and not “every quarterly”. This feature not only gives tremendous relief to the user for tracking the stipulated time of change but also saves lot of money.
WHO BREATHS CO2 IN YOUR IVF LAB ?
If your lab does not have regulated fresh air intake or positive pressure design, there are every chances that your embryologists are breathing out CO2 tanks emptied ever year. Since CO2 can not be absorbed or filtered by Indoor air purifiers or filters. The LAB+GUARD facilitates introduction of fresh air and reduces the risk of high CO2 concentration into the IVF Lab.
ENSURE NET FLOW OUT
In any HVAC/air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas/rooms. This will keep out any toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination.
MAINTENANCE
The LAB+GUARD has automatic indication for Filter change and the design facilitate extremely easy replacement of filters even by non technical staff. Other than filter change it is virtually maintenance free.
Split A/C
Lab Guard
Are you giving thermal shocks to gametes and embryos?
Sudden and drastic temperature losses, recovery times and change in pH are minimized when using Fornax Warming Blocks. The unique aluminum alloy conducts heat and provides almost direct thermal contact with the heating surface. Dishes at room temp when kept for incubation without the Warming Block take a prolonged time to attain the set temperature compared to those dishes kept in preincubated Warming Block, also ensures a safe and easy handling of dishes and test tubes in IVF laboratory.
Warming Blocks
GB
Series
Warming Blocks GB
Series
GB-4WDRA
Made from Aluminum Alloy with hard anodised surface Holding capacity 4 well NUNC 176740 Dimensions 76 x 98 x 15 mm Weight 112 g
GB-717CA
Made from Aluminum Alloy with hard anodised surface Holding capacity 7 tubes of 14 ml / 17 mm Height Weight 83 x 80 mm (d x h) 888 g
GB-PDRA
Made from Aluminum Alloy with hard anodised of surface Holding capacity one Petri Dish Falcon 3002 / 3037 Dimensions 76 x 98 x 15 mm Weight 160 g
GB-IDHA
Made from Aluminum Alloy with hard anodised surface Holding capacity one ICSI dish - Falcom 1006 Dimensions 83 x 8 mm (d x h) Weight 44 g
Ordering information
GB-4WDRA GB-PDRA GB-IDHA GB-717CA order code order code order code order code FX FX FX FX 4025 4026 4027 4028
Shivani Scientific Industries (P) Ltd
26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA e-mail sales@shivaniscientific.com ssipl@bom5.vsnl.net.in
Tel - + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 Fax - + 91 22 2845 7140 + 91 22 2845 6766
Distributor
We make it possible