									                                                              OUTDOOR/ARMORED FIBER OPTIC CABLE
             LINK OUTDOOR/ARMORED FIBER OPTIC CABLE, double jacket,                                                                 Rip - Cord
    armored sheath, single loose tube with up to 12 fibers. An overlapped
                                                                                                                                    Strength Members
    armored layer 0.25 mm, corrugated Electrolytic Chrome Coated Steel
    (ECCS) envelopes the inner sheath of the cable. The steel armored is                                                            Optical Fiber (250 µm)
    coated to inhibit corrosion and to bond to the outer jacket. The sheath                                                         Water Blocking Gel Filling
    is completed with HIGH DENSITY POLYETHYLENE (HDPE) jacket.                                                                      Loose Tube
    The corrugated steel tape coated with polymer armored cable design is                                                           Corrugte Armored Steel
    primarily designed for direct buried applications where there is a threat                                                       Water blocking Tape
    of rodent invading the cable. Other applications include aerial lashedand                                                       HDPE Outer Jacket
    duct. This cable design is rated to Bellcore's superior armored rating for
    cable crush resistance to 440N/cm.

                 Applications                                                                Features
• Special Design for used together with Outdoor and Indoor          • High Performance MM and SM Fiber Optic cable design and test conforms to
• All dielectric Construction                                        TIA/EIA-568, ISO11801, IEC 60793-2-10, ITU Recommendation G.651, G.652, G.655,
• Multimode or Singlemode Fiber Optic                                 Fiber Optic Channel Links, ICEA-596, 640, 696, Bell Core GR-20, GR-409
• Duct, Aerial or Direct buried Install                             • Links between buildings in a campus environment
• IEEE 802.3 (LAN, Ethernet, Fast Ethernet, Gigabit Ethernet • Metro/Access networks, trunk systems and local area network
  and 10 Gigabit Ethernet)                                          • Small diameter single tube construction saves space inside ducts
• ATM, FDDI, CATV, FTTX                                             • Loose tube with Corrugate Armored Steel Construction
                                                                    • Jelly filled buffer tube for water penetration protection
                                                                    • E-glass yarns as strength member
                                                                    • UV-Resistant, HDPE Outer Jacket with Armored and Water Blocking
                                                                    • Tape for outdoor environment protection




                                             Part number                                       Fiber Core                         Description
   MM 50/125 (µm)         MM 50/125 (µm) : XG          MM 62.5/125 (µm)     SM 9/125 (µm)
    UFC 5604                    UFC 5604XG               UFC 6604             UFC 9604              4               F.O Cable Outdoor/Armored 4 Core
    UFC 5606                    UFC 5606XG               UFC 6606             UFC 9606              6               F.O Cable Outdoor/Armored 6 Core
    UFC 5608                    UFC 5608XG               UFC 6608             UFC 9608              8               F.O Cable Outdoor/Armored 8 Core
    UFC 5612                    UFC 5612XG               UFC 6612             UFC 9612             12               F.O Cable Outdoor/Armored 12 Core


                                                             Optical Characteristics
         Fiber Type                          Wavelength                   Max. Attenuation                  Min. Bandwidth             Numerical Aperture
                                               (nm)                           (dB/km)                          (MHz.km)                       (N.A)
                                                1310                            0.35
            SM                                                                                                    N/A                       0.120 ± 0.01
                                                1550                            0.22
                                                 850                            2.5                               500
            50/125                                                                                                                          0.200 ± 0.015
                                                1300                            0.7                               500
                                                 850                            2.3                              1500
            50/125 (XG)                                                                                                                     0.200 ± 0.015
                                                1300                            0.6                               500
                                                 850                            2.7                               200
            62.5/125 (graded-index)                                                                                                         0.275 ± 0.015
                                                1300                            0.6                               600

                                                                 Mechanical Properties
         No. of Fibers           4 ~ 12                           Condition                           Installation                 Long Term
           Cable, mm               10                        Max. Tensile Load, N                        2,700                         600
         Weight, kg/km            124                        Min. Bending Radius, cm                       15                           10
        Jacket Material                                                                          UV-Proof, Black High Density Polyethylene (HDPE)
        Storage Temperature                                                                      -40 °C to + 70 °C
        Operating Temperature                                                                    -40 °C to + 70 °C
        Installation Temperature                                                                 -40 °C to + 70 °C


                                                                                   3

								