AIPHONE DB Series Intercom Brochure

W
Description

AIPHONE DB Series Intercom Brochure

Shared by: LDCOMM
-
Stats
views:
514
posted:
2/16/2010
language:
English
pages:
3
Document Sample
scope of work template
							                    www.leedan.com   info@leedan.com   Toll-Free: 800-231-1414



                                              DB Series




Hands-free Two-Wire Electric Lock Door Phone
Audio Door Entry You Can Count On
                                                                                                                                                                                                                             www.leedan.com                                       info@leedan.com                          Toll-Free: 800-231-1414
Easy to install and simple to use, the DB Series protects private homes and apartments.
For an ideal audio door entry solution, use Aiphone's DB Series !
                     Only 27mm
                                    Hands-Free Communication in Any Place                               2-Wire System for Simple                                                                                             2                                   Bee...                                                     2
                                     With the DB Series' compact design, it                             Installation
                                     can fit anywhere in your home.                                     With the easy to install two-wire system, use                                                                                                                                                                      No additional
                                     Convenient hands-free communication                                the DB Series to replace your door bell.
                                                                                                                                                                                                            Door bell                      Speaker                        Replace                                          wire required
                                     is convenient for anyone to use.
                                                                                                         System Configuration

                                                                     Hands-Free
                                                                                                                          For Private Homes
                                                                                                                                                          Standard set                                                   Request to
                                                                                                                                                                                                                                                                                             Sub masters
                                                                                                                                                                                                                         exit/entry button

                                    Up to 5 Inside Stations With
                                    Room-to-Room Communication                                                                   2                                         2                                               4                                                      4                            4                            4
                                     Unable to answer your door from the Master station?
                                     No problem! Talk with visitors from anywhere in your home
                                     with up to 4 additional Sub master stations. Inside stations can                                                                                                                                                                             2                                                         2
                                     be used for room-to-room communication.                                  EL-12S                           DA-1DS
                                                                                                              Electric door strike             Door station silver panel
                                                                                                                                                                               DB-1MD                                                                    DB-1SD                       DB-1SD                       DB-1SD                         DB-1SD
                                                                                                                                                                               Master station                                                            Sub master                   Sub master station           Sub master                     Sub master station
                                                                                                                                                                                                                                                         station                                                   station
                                                                                                                                                                                                                                                                          2                                                   2
                                                                                                                                                                                    2                                                                             PT-12                                                    PT-12
                                                                                                                                                                                      PT-12

                                                                                                                                                                                                                                     or
                                                                                                                                                                                      DBS-1AP                       IER-2                      TAR-3
                                                                                                                                                                                      DBS-1A                        Call extension             External
                                                                                                                                                                                      Kit box                                                  signaling relay
                                                                                                                                                                                                                                                                                      PT-12 : AC transformer PT-1211DR, PT-1211C, PT-1211D
                                     Call multiple inside stations at
                                     the same time for room-to-room
                                     communication.
                                                                                                                          For Apartment Blocks
                                                                                                                                                                     Residence 1
                                                                                                                                                            2                                                                              4                                      4                        4                            4
                                                                                                                                                                                                                   2                                                              2                                                     2
                                                                                                                                                                                     2
                                                                                                                                                                                                                            or                      2        DB-1SD                   DB-1SD               2       DB-1SD                       DB-1SD
                                                                                                                                                                                                                                                             Sub master station       Sub master station           Sub master station           Sub master station
                                                                                                                                                                               PT-12 DB-1MD                    IER-2          TAR-3                   PT-12                                                    PT-12
                                    Option Button                                                                                                                                          Master station      Call extension External
                                                                                                                                                                                                                              signaling relay

                                     Use the Option button to control an external device, such as
                                     an entrance light.                                                                                                     2        Residence 2
                                                                                                                                                                                                                                           4                          4                      4                         4
                                                                                                                                                                                       2                                                          2                       2   Same as the above
                                                                                                                                                                                                                                                                                    2       2
                                                                                                                                                                                                       DB-1MD
                                                                                                                                                                                 PT-12                 Master station                     PT-12                                              PT-12



                                                                                                                                                            2        Residence 3
                                                                                                                                                                                                                                           4                          4                      4                         4
                                                                                                                                                                                       2                                                          2                       2   Same as the above
                                                                                                                                                                                                                                                                                    2       2
                                                                                                                                                                                                       DB-1MD
                                                                                                                                                                                 PT-12                 Master station                     PT-12                                              PT-12


                                                                                                                      2                                     2        Residence 4
                                                                                                                                                                                                                                           4                          4                      4                         4
                                                                                                                                                                                       2
                                                                                                                                                                                                       DB-1MD
                                                                                                                                                                                                                                                  2                       2   Same as the above
                                                                                                                                                                                                                                                                                    2       2
                                    Chime Sound                                                           EL-12S
                                                                                                          Electric door strike
                                                                                                                                 DA-4DS
                                                                                                                                 4-Call door station                             PT-12                 Master station                     PT-12                                              PT-12
                                     Just a press of the Call button of Door station rings the chime                             DA-2DS
                                                                                                                                 2-Call door station
                                     continuously for appropriate time (approximately 4 seconds).                                                                                                                                                                                     PT-12 : AC transformer PT-1211DR, PT-1211C, PT-1211D
  DB Series                                                                                     www.leedan.com                         info@leedan.com                     Toll-Free: 800-231-1414

 Line up




                                                                                                                                                          PT-1211DR               PT-1211C              PT-1211D
                                                                                                                                                          AC transformer          AC transformer        AC transformer



      DA-1DS                         DA-2DS                         DA-4DS                          DB-1MD                      DB-1SD
      Door station silver panel      2-Call door station            4-Call door station             Master station              Sub master station           Boxed set




                                                                                                                                                              DBS-1AP :
                                                                                                                                                              DB-1MD, DA-1DS, PT-1211DR
  IER-2                     EL-12S                TAR-3               AC-10S                        AC-10F                          DAW-P
  Call extension            Electric door         External            Vandal resistant              Vandal resistant                Door station              DBS-1A :
                            strike                signaling relay     access control keypad,        access control keypad,          mounting plate
                                                                      surface mount                 flush mount                     (83.5mm)                  DB-1MD, DA-1DS, PT-1211C or PT-1211D
 Unit dimensions (mm)
 DA-1DS                                      DA-2DS/4DS                             DB-1MD/1SD                       PT-1211DR                                PT-1211C                      PT-1211D
                                  22                                     22                    80          27                   54             61
               100                                         100                                                                                                    60         48                    58        46
                                                                                                                        102




                                                                                                                                                      77




                                                                                                                                                                                         83
175




                                            175




                                                                                 185




                                                                                                                     IER-2                  88             29              TAR-3          104                 41




                                                                                                                                                                                                        62
                                                                                                                                                             83.5
                                                                                                                              120




 Features
  Two-wire system including door release
                                                                                                                     AC-10S               98         25                     AC-10F          117              5 45
  Door release wired to door station, requiring no power transformer
  Total hands-free communication, auto-voice actuation
  Press-to-talk operation available
                                                                                                                                                                     68.5


                                                                                                                                                                                 132
                                                                                                                              125




                                                                                                                                                             55




                                                                                                                                                                                                                         100
  User-optional function button
  Call tone MUTE with indicator
  Call extension sounder
                                                                                                                                                     33
 Specifications
 Power source                 15V AC
                                                                                                                                                     Caution
 AC transformer               PT-1211DR, PT-1211C, PT-1211D
                                                                                                                                                     When existing chime wires are used, it is possible they
 Communication                Approx. 1 min.                                                                                                         contain AC voltage. Electric shock or unit damage could
                              AUTOMATIC (Hands-free); To activate, momentarily press TALK button.
                              MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more.                           result. Ask a qualified electrician for more details.

 Door release                EL-12S or others (More than (AC) 70 , AC 9.5 ~ 20V)
 Option contact (AC/DC)      Voltage Max. : 24V, Min. :1V           Current Max. : 1.6A, Min. : 10mA
 Wiring                      2 wires, throughout AC trans - Master - Door - Door release
                                                                                                                                                      Door bell        Speaker
                                                                                                                                                                                    Replace
 Distance                     PT-1211DR/C/D ~ Door rlse. 110m(0.6mmØ) 200m(0.8mmØ) 310m(1.0mmØ)
                              PT-1211DR/C/D ~ DB-1MD 55m(0.6mmØ) 100m(0.8mmØ) 155m(1.0mmØ)
                              DB-1MD ~ farthest DB-1SD 100m(0.6 ~ 1.0mmØ)
                                                                                                                                                                AC



   Distributed by :




   DB(E)0809A
                                                                                                                                                                                       Printed in Japan (E)
      All rights reserved. All statements valid at time of printing. The design and specifications are subject to change without notice for improvement.                                    MA52004AYZ

						