Docstoc

WORKING VERSION-EONNAGATA-2009-RIDER

Document Sample
WORKING VERSION-EONNAGATA-2009-RIDER Powered By Docstoc
					                                 EONNAGATA
                                 Ex Machina / Sadler’s Wells

                         TECHNICAL RIDER – version 2.0
                                        April 6, 2009



            Table of contents:

            1.    Company’s touring crew
            2.    Venue / Seating
            3.    Stage requirements
            4.    Masking
            5.    Lighting
            6.    Power feed
            7.    DMX control
            8.    Sound
            9.    Subtitles
            10.   Wardrobe
            11.   Properties
            12.   Production Schedule
            13.   Local Crew Requirements
            14.   Rehearsal Space
            15.   Dressing Rooms
            16.   Freight
            17.   Catering
            18.   Miscellaneous




Production Manager:     Eric Gingras        egingras@exmachina.qc.ca
Technical Director:     Eric Gautron        egautron@exmachina.qc.ca
                                Ex Machina – EONNAGATA – Technical Specifications




1. Company’s Touring Crew
      •    3 performers
      •    1 tour manager
      •    1 technical director
      •    1 stage manager
      •    1 head of lighting / operator
      •    1 head of sound / operator
      •    1 props/costumes/wigs manager

The director’s agent, the performer’s agents and the company’s agents and producer may join the touring
crew from time to time.

2. Venue / Seating
      •    Frontal seating is required

      •    Sound control position must be in the audience, centre stage. Control booth and balcony
           positions will not be accepted.

      •    In industrial or warehouse-type venues, an appropriate stage needs to be built from platforms
           to compensate for the absence of a higher stage. If this type of stage needs to be built, it
           must meet all of the Company’s requirements and should done prior to the Company’s arrival.

3. Stage requirements
** Under no circumstances will the Company perform on a concrete stage, or on a stage surface
directly atop concrete. **

      •    The stage must be a smooth, straight and levelled sprung dance floor.
           All holes and cracks must be filled.

      •    The entire performance space must be covered with a clean black dance floor (provided by
           the Presenter). The installation of the dance floor should be done in such a fashion that the
           seams are the least visible and covered with an appropriate black PVC tape.

      •    The wing space and crossover must be covered with clean black carpets.

      •    The entire stage surface must be swept and the performance space must be mopped
           approximately 45 minutes before every rehearsal and/or performance or when asked by the
           technical director.

      •    Raked stages need to be studied prior to approval.




  2 / 13                                               v. 2.0                                     09-04-05
                               Ex Machina – EONNAGATA – Technical Specifications


    •    A proscenium arch is required. In industrial or warehouse-type venues, appropriate masking
         may compensate for the absence of a proscenium arch, (masking should be hung prior to the
         Company’s arrival).

         Venue’s minimum proscenium arch opening:

         Width:                     40’-0” (12200mm)
         Height:                    20’-0” (6100mm)

    •    Stage dimensions: (including wing space)

         Depth:                     50’-0” (15240mm)
         Width:                     72’-6” (22100mm)
         Height:                    59’-0” (18000mm)

    •    Performance space:

         Depth:                     43’-0” (13100mm)
         Width:                     39’-4” (12000mm)

    •    Wing space:

         Stage right
         Depth:                     50’-0” (15240mm)
         Width:                     16’-5” (5000mm)

         Stage left
         Depth:                     50’-0” (15240mm)
         Width:                     16’-5” (5000mm)

         Upstage
         Depth:                     7’-0” (2140mm)
         Width:                     72’-6” (22100mm)


                   **** These are minimum dimensions, use only as reference. ****




3 / 13                                                v. 2.0                               09-04-05
                                Ex Machina – EONNAGATA – Technical Specifications




4. Masking/Set
      •    A total of 34 bars are needed in order to hang the Company’s set, masking and lighting.
      •    2 of which will fly during the performance.

      •    The Company will provide 5 sets of rigid legs; two sets (2) will be setup on traveller rails. This
           masking system will be used in conjunction with house soft goods.

      •    Rigid masking dimensions:
           5 sets of legs - 28’-7” (8750mm) high x 6’-6” (2000mm) wide
           2 traveller rails - 52’-6” (16000mm) long

      •    Presenter must provide the following:

           ⇒        6 sets of black legs (min. dim. 30’-0” (9140mm) high x 10’-0” (3050mm) wide)
           ⇒        6 black borders (min. dim. 13’-0” (4000mm) high x 59’-0” (18000mm) wide)
           ⇒        1 black backdrop (min. dim. 28’-0” (8530mm) high x 50’-0” (15240mm) wide)
           ⇒        1 black backdrop (min. dim. 28’-0” (8530mm) high x 50’-0” (15240mm) wide)
           ⇒        1 set of black half-tabs (total dim. 28’-0” (8530mm) high x 50’-0” (15240mm) wide)

           ⇒        3 riser platforms, according to the following dimensions (L x W x H):

                    - 48’-0” (14630mm) X 5’-0” (1524mm) X 1’-4” (406mm)
                    ** this platform needs a clean black front facing **
                    - 8’-0” (2440mm) X 4’-0” (1220mm) X 1’-4” (406mm)
                    - 8’-0” (2440mm) X 2’-0” (610mm) X 8” (203mm)

           ⇒        The platforms need to be safe and secure for performers to dance on, all tops need
                    to be black and free of any debris.

           ⇒        Appropriate steps on either end of this riser platform
                    - step dimensions 1’-4” (406mm) deep x 8” (203mm) high x 8’-0” (2440mm) wide

           ⇒        Counterweights (either sandbags or steel weights)
                    - total weight – 220 lbs. (100kg)

      •    The Company will provide a complete masking plan.
           Whenever possible, it would be a great advantage to hang the soft goods according to the
           provided plan before the Company’s arrival.


** The Presenter should ensure that all the required equipment will be at the theatre prior to the
Company’s arrival.**




  4 / 13                                               v. 2.0                                       09-04-05
                               Ex Machina – EONNAGATA – Technical Specifications




5. Lighting
      •    The Company’s lighting equipment consists of:

           ⇒        15x (+3)        VariLite VL3500Q spot
           ⇒        18x             ETC Source4 zoom 25/50 750w (with gobo holders)
           ⇒        6x              Altman ZipStrip ZS-3 (76’’)
           ⇒        8x              Par20 NSP 50W
           ⇒        1x              DMX opto splitter
           ⇒        1x              Power Distribution for VL’s
           ⇒        1x              MA Lighting - grandMA (full size)
           ⇒        1x              MA Lighting – grandMA (light)
           ⇒        1x              Ethernet hub + RJ45 cables (to link the control desks)
           ⇒        3x              LED strip lighting (tables)
           ⇒        1x              LED strip lighting (pendulum)

      •    Presenter must provide the following instruments and hardware:

           ⇒        89x          1.2Kw dimmers – DMX protocol
           ⇒        1x           5.0Kw dimmer – DMX protocol
           ⇒        18x          STRAND SL Zoom 23/50
           ⇒        8x           ETC Source4 ZOOM 25/50
           ⇒        6x           36 degree ETC Source 4 – 575W
           ⇒        14x          26 degree ETC Source 4 – 575W
           ⇒        10x          19 degree ETC Source 4 – 575W
           ⇒        1x           Strand Fresnel 5000W
                                 (to be used without lens, ensure that there is a proper safety mesh)
           ⇒        1x           MDG Atmosphere HAZER
           ⇒        1x           MDG Max 3000 fogger

           ⇒        16x          floor bases
           ⇒        4x           boom stands 2m (6’-6”) high
           ⇒        2x           gobo holders for ETC Source 4 (size B)
           ⇒        15x          cables and appropriate adaptors for 15 extra instruments if local outlets
                                 are not U-ground or Shuko type.
                                 (The Company will provide these extra instruments.)

*** Any and all lighting equipment equivalences must be verified and confirmed with the
Company’s technical director. ***

      •    Notes:
           ⇒        All Profiles should be equipped with 4 functional shutters.
           ⇒        All Fresnels should be equipped with functional barn doors.
           ⇒        All instruments should be equipped with gel frame holders, tight clamps, safety wires.
           ⇒        The power feed for lighting should be independent from the sound power feed.
           ⇒        This inventory doesn’t include equipment for house lights. If the venue is not
                    equipped with a proper house light system, presenter must supply the extra
                    equipment required.
           ⇒        Company will supply presenter a complete lighting plan.



  5 / 13                                              v. 2.0                                     09-04-05
                              Ex Machina – EONNAGATA – Technical Specifications




6. Power feed

     •    The Company needs one independent power feed in order to connect lighting dimmers and
          moving light power distribution.

          Europe:                          230 volts/125 amps/three phases
          North America:                   120/208 volts/125 amps/three phases

     •    Power source should be no further than 50 feet (15.24 m) from the set, unless presenter
          provides extra power lines.

     •    Electrical connection to the power source must be done by a local certified electrician on the
          first day of set-up, and disconnection should be done on the evening of the strike.

     •    If the primary voltage is over 230 Volts, presenter must supply a voltage stabilizer.


7. DMX control

     •    Protocol
          ⇒        1 DMX output on stage left for the Company’s equipment
          ⇒        1 DMX output for in-house dimmers
          ⇒        2 DMX inputs will be needed in the house during rehearsals.
          ⇒        2 DMX inputs will be needed in the booth during performances.

 **Ex Machina uses a wireless DMX system that operates in the 2.4 Ghz frequency range which
 doesn’t require a permit but may be disrupted by some machines. No internet wireless routers
 or cordless phone operating in this range should be used in the hall during rehearsal and
 showtime.**




 6 / 13                                              v. 2.0                                       09-04-05
                                     Ex Machina – EONNAGATA – Technical Specifications




8. Sound
   ** Sound control position must be in the audience, orchestra level, and centre stage. Control
   booth and balcony positions will not be accepted.**

       •     The production requires a professional quality sound system suitable to the venue capable of
             loud and clear reproduction of all frequencies free from any distortion, hiss or interference to
             all parts of the auditorium. Please advise of your in-house equipment.

       •     Presenter must provide the following:

Mixing board

       •     One (1) Yamaha DM2000
                    INCLUDING an extra 8 analog outputs card and breakout cable (XLR).
Speakers

       •    A set of three (3) two-way, full range, wide dispersion speakers to be used as the MAIN MIX
            program and rigged at the left, center and right, in front of the first border. All speakers need
            to be at the same height and at the same distance from the first border. The dispersion of an
            individual speaker should be at least 80° X 40° or 90° if a coaxial design is used.
            ⇒         Preferred speakers: Three (3) Meyer CQ-1
            ⇒         Alternate speakers: Three (3) L-Acoustics 112P


       •    A SECOND set of two (2) two-way, full range, wide dispersion speakers to be used as the
            AWAY program and flown in a left-right configuration, upstage of the performance area, at
            approximately 4m from the stage floor. The dispersion of an individual speaker should be at
            least 80° X 40° or 90° if a coaxial design is used.
            ⇒        Preferred speakers: Two (2) Meyer UPA1-P
            ⇒        Alternate speakers: Two (2) L-Acoustics 112P


       •    A set of two (2) subwoofers with 18 inches drivers, one on each side of the stage. To be fed
            by one individual output of the mixing board; not the same as the left and right mix.
            ⇒         Preferred speakers: Two (2) Meyer 700HP
            ⇒         Alternate speakers: Two (2) L-Acoustics SB218


       •     A minimum of three (3) wide dispersion speakers to be used as a DELAY line (L,C,R). In
             wide halls, more speakers may be needed to cover the whole audience.

**Please advise, and provide details, if there is a delay type program permanently setup in the venue.**
In a venue with balcony (circle), a set of three (3) or four (4) extra speakers for each balcony level will be required to
be use as DELAY-type program. An appropriate delay unit will be required to feed each balcony level from our
digital board.
            ⇒          Preferred speakers: Three (3) Meyer UPA1-P
            ⇒          Alternate speakers: Three (3) L-Acoustics 112P



   7 / 13                                                   v. 2.0                                              09-04-05
                                     Ex Machina – EONNAGATA – Technical Specifications




       •     A set of four (4) speakers to be used as a SURROUND type program These speakers should
             be installed in the hall to provide ambiance from the back and the side of the audience.
In a venue with balcony (circle), a set of two (2) or four (4) extra speakers for each balcony level will be required to
be used as SURROUND type program.
            ⇒          Preferred speakers: Four (4) Meyer UPM1-P
            ⇒          Alternate speakers: Four (4) L-Acoustics 8XT


       •    A set of two (2) two-way, full range, wide dispersion “SIDE FILL” speakers to be flown in
            stage wings (focused towards performance space) at approximately 3m from the stage floor.
            The dispersion of an individual speaker should be at least 80° X 40° or 90° if a coaxial design
            is used.
            ⇒         Preferred speaker: Two (2) Meyer UPA1-P
            ⇒         Alternate speakers: Two (2) L-Acoustics 112P


       •    A set of two (2) two-way, full range, wide dispersion “STAGE MONITOR” speakers to be set
            upstage of the riser platform (focused towards performance space) The dispersion of an
            individual speaker should be at least 80° X 40° or 90° if a coaxial design is used.
            ⇒         Preferred speaker: Two (2) Meyer UM-100P
            ⇒         Alternate speakers: Two (2) L-Acoustics 112P


       •     The presenter must ensure that all cabling between amplifiers and speakers is
             provided as well as all rigging hardware that may be necessary for the proper
             positioning of any and all speakers.


Microphones

       •    Two (2) cardoid pattern microphones.
            ⇒       Preferred microphone: Two (2) Shure SM-58
            ⇒       Alternate microphone: Two (2) Shure SM-57

       •     We also use (provided by the Company) a Lectrosonics wireless microphone system
             (5 transmitters and 1 receiver) that operates in the 470.1 MHz to 495.6 MHz frequency
             range.

       •     Presenter is responsible for applying and obtaining wireless permits for the provided wireless
             microphone and communication system. Frequencies must be clear of interference.

       •     If those frequencies are not available for entertainment in the country/region where the
             performance will take place, the presenter must supply equivalent equipment with legal
             frequencies and verify all the details with the technical director of the company.
             We carry our own MKe2 lavaliers mounted in custom holders; in the case that we cannot use
             our wireless transmitters; replacement units SHOULD be able to accept TA5F connectors.




   8 / 13                                                   v. 2.0                                             09-04-05
                                Ex Machina – EONNAGATA – Technical Specifications


XLR (CANON) cables

      •    15 X 10’-0” (3000mm)
      •    10 X 25’-0” (7500mm)
      •    10 X 50’-0” (15000mm)
      •    One multi-pair cable (snake) 24 pairs to be run from stage left to the FOH mixing position, if
           there is no permanent interconnection between the mixing position and the stage.

      •    Note: This cable listing does not include the cables for the speakers wiring.(Power and signal)

Communication

      •    A professional quality intercom system (hardwired) with a minimum of 4 (hardwired)
           beltpacks along with six wireless beltpacks, and a total of 10 headsets (single-ear)
      •    Both local intercom systems (wireless and hardwired) should be interfaced together.
           All intercommunication systems should be free of any and all interference.

Other

      •    Four (4) active direct boxes (DIs)
      •    Six (6) microphone boom stands


9. Subtitles
      •    The show can be performed in FRANÇAIS or in ENGLISH, according to the presenter’s
           choice. If the presenter should decide to add subtitles for another language, the following
           requirements should be met.

      •    The presenter must provide the following:

           ⇒       A professional translation of the spoken text
                   (for the latest version of the performed text – contact Eric Gingras, production
                   manager – egingras@exmachina.qc.ca)
           ⇒       A subtitle operator
                   (it is preferred that the translator operate the subtitles for the performance)
           ⇒       All technical equipment necessary to the proper projection of the subtitles (computer
                   interface, video projector, projection screen or other appropriate system)
           ⇒       Positioning of the projection surfaces, and all other aesthetic considerations should
                   be validated by the company’s Technical Director.

** The Company would like to ensure that the projection surfaces do not impede visually on the
performance, and also do not detract entirely the audience’s focus.**




  9 / 13                                               v. 2.0                                     09-04-05
                               Ex Machina – EONNAGATA – Technical Specifications




10. Wardrobe
    •      The Company travels with 3 wardrobe crates. Upon arrival at the venue we will need access
           to dressing rooms and wardrobe maintenance rooms.

    •      The presenter must provide the following:

           ⇒       4 portable costume racks
           ⇒       Access, within the venue, to washing and drying machines as well as a steamer, an
                   iron, an ironing board and a sewing machine.
           ⇒       Laundry detergent
           ⇒       The local wardrobe manager must be the same for setup, rehearsals, performances,
                   and strike.
           ⇒       The Company’s wardrobe manager will provide detailed instructions on wardrobe
                   maintenance.
           ⇒       Wardrobe maintenance, laundry and dry cleaning should be done on first day of
                   setup and should be completed 2 hours before show time on performing days

     **Access to a local, rapid, dry cleaner service is essential (along with transportation)**

    ** The Company’s wardrobe Manager may accompany the local wardrobe manager to the
    dry cleaners for their first cleaning, during the first day of setup.**


11. Properties
    •      The presenter must provide the following:

           ⇒       4 props tables 1m x 2m (3’-0’’ x 6’-0’’) on stage (2 on stage left 2 on stage right);
                   these tables must be covered with heavy black fabric.


12. Production Schedule
    •      Generally speaking, three days of work (morning, afternoon, evening) are required to set-up.
    •      First performance takes place in the evening on the third day.
    •      Security/safety/fire inspections should take place on the morning of the second day.
    •      Performance length: approximately 85 minutes without intermission.
    •      Strike should begin 30 minutes after the end of the last performance.

    **A detailed set-up, performance and strike schedule will be provided by the Company.**




 10 / 13                                              v. 2.0                                        09-04-05
                                  Ex Machina – EONNAGATA – Technical Specifications




13. Local Crew
**We require a sober and well-rested stage crew.**

First Day Set-Up and Strike crew

      •      6 truck loaders *
      •      6 stagehands
      •      1 head flyman (please add necessary staff for manual counterweight systems)
      •      1 head electrician
      •      4 electricians
      •      1 head sound technician
      •      1 sound technician
      •      1 wardrobe manager
      •      1 property master (if required by local union)

* Stagehands can load and unload truck if allowed by the local union.

** If the technical crew does not speak English or French, presenter should provide the
appropriate amount of translators.**

Show crew

**Local show crew must be the same for all rehearsals and performances**

      •      3 stagehands
      •      1 head flyman
      •      1 head electrician
      •      1 head sound technician
      •      1 wardrobe manager
      •      1 property master (if required by local union)
      •
** Company’s technical crew will operate lighting and sound controls during rehearsals and performances.**
** Local stagehands must dress in black (with long sleeves) during performances.**



      **A detailed set-up, performance and strike schedule will be provided by the Company.**




   11 / 13                                               v. 2.0                                         09-04-05
                               Ex Machina – EONNAGATA – Technical Specifications




14. Rehearsal Space
    •      The Company will need an appropriate rehearsal space for warm-up and rehearsal sessions.
           Ideally this space should be located within the performance venue.
    •      This space should be reserved for the Company’s performers according to a pre-determined
           schedule.
    •      The rehearsal space must be adequately heated or cooled to approximately 21°C (70°F).
    •      The floor should be made of hardwood covered by an appropriate dance floor.
    •      The Company will use the rehearsal space 4 hours a day. The space should be available the
           day of the Company’s arrival in the performance city.
    •      If the rehearsal space is within the same venue as the performance space, the Company will
           use the rehearsal space prior to all performances, in a case where the rehearsal space is not
           located within the performance venue the Company will use the stage.
    •      The Company will need an appropriate sound system for the rehearsal space, with a CD
           player and an AUX input (1/8” telephone jack).
    •      The Company will need one (1) ballet bar, and two (2) full-size mirrors. A ballet bar should be
           available on stage prior to all performances.




15. Dressing Rooms
    •      The presenter must provide the following:

           ⇒       3 separate single dressing rooms: each containing a makeup table, appropriately
                   controlled lighting, individually controlled heating and cooling, chairs, mirrors,
                   costume rack, a WC and a shower
           ⇒       1 dressing room for the Company’s technical crew
           ⇒       1 dressing room for costume and wig maintenance
           ⇒       1 dressing room or suitable room will be used as a production office. This room
                   needs to be equipped with a desk, proper electrical outlets, a telephone, and a
                   high-speed internet connection.
           ⇒       All dressing rooms must be clean and secure, the Company should be able to lock
                   all the dressing rooms, and the keys should be given to the tour manager.
           ⇒       All dressing rooms must have 2 bath and 2 hand towels per day, as well as soap.




 12 / 13                                              v. 2.0                                     09-04-05
                                Ex Machina – EONNAGATA – Technical Specifications




16. Freight
     •      The Company’s cargo is contained in approximately 14 transportation crates / racks.
     •      The Presenter should provide storage space (approximately 28 square meters / 300 square
            feet) for empty crates during show run. This space can be adjacent to the stage area but is
            not included in performance space, nor wing space dimensions.


17. Catering
     •      The presenter must provide the following:

            ⇒       Bottled water, fruit juices and coffee during the setup (6 people).
            ⇒       Bottled water, fruit juices, coffee, assorted nuts, chocolate and fruit platters during
                    the rehearsals and performances (10 people).
            ⇒       10 bottles of water as well as 2 Kg of ice (or ice packs) should be readily available on
                    either side of the stage during rehearsals and performances.

18. Miscellaneous
     •      If the local technical crew does not speak FRENCH or ENGLISH, Presenter shall provide the
            appropriate amount of translators to collaborate with the Company’s technical crew
            throughout the setup, rehearsal and performances.
     •      Prior to the arrival of the Company, the Presenter shall provide the Company’s tour manager
            with all emergency medical services addresses and phone numbers, as well as Doctor /
            Chiropractor / Physiotherapist / Massage Therapist service addresses and phone numbers.




Ex Machina
103 Dalhousie Street
Québec (QUÉBEC)
Canada
G1K 4B9

t : 418-692-5323
f : 418-692-2390




  13 / 13                                              v. 2.0                                      09-04-05
                                                                              EONNAGATA
                                                                         LINESET - April 6, 2009


        BAR              FUNCTION          HEIGHT          OPENING                                     DETAILS                                     Distance from Zero
                       -- SOUND 1 --    8,25m (27'-0")        -           3x speakers (MAIN MIX program - L,C,R)                                     -0,5m (- 1'-8")
                          Border         6,5m (21'-4")         -          house soft goods                                                                0m
                            LX-1         7,5m (24'-7")         -                                                                                      0,3m (1'-0")
                         Hard legs      8,95m (29'-4")    12m (39'-4")    * Company's hard legs                                                       0,4m (1'-4")
                            Legs               -          15m (49'-2")    house soft goods                                                            0,5m (1'-8")
                          Border         6,2m (20'-4")         -          house soft goods                                                            1,22m (4'-0")
                            LX-2          8m (26'3")           -                                                                                      1,55m (5'-1")
                            LX-3         7,5m (24'-7")         -                                                                                       2m (6'-7")
                         Hard legs      9,05m (29'-8")    12m (39'-4")    * Company's hard legs and Traveller                                         2,3m (7'-7")
                            Legs               -          15m (49'-2")    house soft goods                                                            2,4m (7'-11")
                                                               -                       ** these two bars wil need to be linked together;              2,6m (8'-6")
                         Pendulum        8,9m (29'-2")
                                                               -                                   and stayed accordingly**                           3m (9'-10")
                       -- SOUND 2 --      2,2m (7'-2")    15m (49'-2")    2x speakers (SIDEFILL program) (trim height from underside of speaker)      3,3m (10'-8")
                          Border        6,56m (21'-6")         -          house soft goods                                                            3,4m (11'-3")
                            LX-4         7,5m (24'-7")         -                                                                                      3,7m (12'-1")
                            LX-5        7,74m (25'-4")         -                                                                                      4,1m (13'-4")
                       -- SOUND 3 --     4,5m (14'-9")    11m (36'-1")    2x speakers (SIDEFILL program) (trim height from underside of speaker)      3,3m (10'-8")
                         Hard legs      9,05m (29'-8")    12m (39'-4")    * Company's hard legs and Traveller rail                                    4,3m (14'-2")
                            Legs               -          15m (49'-2")    house soft goods                                                            4,4m (14'-6")
                          Border        6,37m (20'-10")        -          house soft goods                                                            5,3m (17'-6")
                            LX-6         7,5m (24'-7")         -                                                                                      5,8m (19'-0")
                         Hard legs      8,95m (29'-4")    12m (39'-4")    * Company's hard legs                                                       6,3m (20'-8")
                            Legs               -          15m (49'-2")    house soft goods                                                            6,4m (21'-0")
                            LX-7        7,71m (25'-3")         -                                                                                      6,6m (21'-8")
                          Border         6,5m (21'-4")         -          house soft goods                                                            7,9m (26'-0")
                            LX-8         7,5m (24'-7")         -                                                                                      8,3m (27'-3")
                         Hard legs      8,95m (29'-4")    10m (32'-9")    * Company's hard legs                                                       8,6m (28'-3")
                            Legs               -          13m (42'-7")    house soft goods                                                            8,7m (28'-7")
                          SCRIM               tbc              -          * Company's SCRIM                     -MOVING DURING PERFORMANCE-           8,8m (29'-0")
                       -- SOUND 4 --      4m (13'-1")     13m (42'-7")    2x speakers (AWAY program) (trim height from underside of speaker)          9,2m (30'-2")
                        BACKDROP         6,5m (19'-8")         -          house soft goods                                                           9,7m (31'-10")
                            Legs               -          11m (36'-1")    house soft goods                                                            9,9m (32'-6")
                        PVC screen             -                          * Company's PVC screen                                                     10,1m (33'-1")
                          Border        4,87m (15'-11")        -          house soft goods                                                           11,8m (39'-0")
                            LX-9         4,5m (14'-9")         -                                                                                     12,3m (40'-4")
                          Half tabs            -           1m (3'-0")     house soft goods                                                          13,25m (43'-6")
                            Leg                -                          house soft goods - single leg on centre                                    13,7m (45'-2")
        TBC             Wing lighting          -               -          * off-stage lighting positions will be confirmed on site *                       TBC

                                                          The distance from Zero is mesured from the first border.



Technical director: Eric Gautron
email: egautron@exmachina.qc.ca                                                                                                                                         06/04/09

				
DOCUMENT INFO
Shared By:
Stats:
views:13
posted:2/8/2010
language:English
pages:16