water meters guide

Document Sample
water meters guide Powered By Docstoc
					water meters guide
                                              USF and USC
We have the experience of nearly fifty years in the manufacture of water meters
for use within the domestic and commercial applications. Our range of meters
now extends to include a size range from 1/2” BSP to DN 500 flanged meters.
Altecnic, along with Europe’s leading manufacturers of water meters, have
assembled one of the most comprehensive product portfolio available today.
We have meters covering a range of classes - A,B,C and D applications.


USF and USC Range
The USF and USC range of 1/2” and 3/4” meters is a compact and economic range of water
meters, which benefit from the following features
     • Single Jet Water
     • USF models suitable for use with cold water up to 30°C
     • USC models suitable for use with hot water up to 90°C
     • Direct dry dial roller indicator
     • Tamper proof cover                                                                Dimensions
     • Movable dial to enable reading to be taken
     • Operational position CLASS B when horizontal
     • Operational position CLASS A when vertical
     • Hydraulic performance in accordance with EEC 75/33


Technical Data
                                                                         13      20
Q max Maximum Flow Rate                                         m /h
                                                                 ³        3       5
Qn        Nominal Continuous Flow Rate                          m³/h     1.5     2.5
Qt        Transitional Flow Rate with ±2% error in Class B      I/h     120      200
Q min Minimum Flow Rate with ±5% error in Class B               I/h      30      50
Qt        Transitional Flow Rate with ±2% error in Class A      I/h     150      250
Qmin Minimum Flow Rate with ±5% error in Class B                I/h      60      100
          Starting Flow                                         I/h       7      15
          Minimum Reading                                       m³      0.001   0.0001                                                13     20

          Maximum Reading                                       m³     100.000 100.000   A   Length without pipe fittings        mm   110    130

          Maximum Working Pressure                              Bar      16      16          Length with pipe fittings           mm   190    225
                                                                                         B   Maximum diameter                    mm   80     80

Head Loss Diagram                                                                        C   Base line to top with lid upright   mm   138    143
                                                                                         D   Base line to top                    mm   66     70
                                                                                         E   Centre line to base                 mm   16     190
                                                                                             Weight including pipe fittings      Kg   0.72   0.92
                                                                                             weight excluding pipe fittings      Kg   0.58   0.68




  1
                                      DBRF and DBRC
DBRF and DBRC Range
The DBRF and DBRC range of 1/2” to 1 1/2” meters is a robust and reliable range of water
meters, which benefit from the following features:

     • Single Jet Water
     • DBRF models suitable for use with cold water up to 30°C
     • DBRC models suitable for use with hot water up to 90°C
     • Direct read roller indicator
     • Indelible wet dial
     • Hydraulic performance in accordance with EEC 75/33


Technical Data
                                                DN      13        20     25     30      40
Q max Maximum Flow Rate                        m /h
                                                 ³       3         5      7      10     20
                                                                                                Dimensions
Qn        Nominal Continuous Flow Rate         m³/h     1.5       2.5    3.5     5      10
Qt        Transitional Flow Rate with ±2% error I/h     120       200    280    400    800
Q min Minimum Flow Rate with ±5% error          I/h     30        50     70     100    200
          Starting Flow                         I/h     10        15     20      20     25
          Minimum Reading                       m³     0.001     0.0001 0.0001 0.0001 0.0001
          Maximum Reading                       m³    100.000 100.000 100.000 100.000 100.000
          Maximum Working Pressure              Bar     16        16     16      16     16


Head Loss Diagram




                                                                                                                                             13   20   25   30   40
                                                                                                A   Length without pipe fittings        mm 110 130 160 160 200
                                                                                                    Length with pipe fittings           mm 190 228 260 280 340
                                                                                                B   Maximum diameter                    mm   80   80   100 100 100
                                                                                                C   Base line to top with lid upright   mm 150 150 185 185 200
                                                                                                D   Base line to top                    mm   83   83   103 103 120
                                                                                                E   Centre line to base                 mm   24   24   34   34   34
                                                                                                    Weight including pipe fittings      Kg 0.85 1.10 1.75 2.00 3.46
                                                                                                    weight excluding pipe fittings      Kg 0.69 0.86 1.28 1.33 2.42
                                          waltman WARF
Waltman WARF
The WARF range of DN50 to DN 500 meters is a helical vain type water meter, which benefit from
the following features:

     • High capacity helical vein meter
     • WARF models suitable for use with cold water up to 50°C
     • WARF models suitable for use with hot water up to 130°C
     • Replaceable/Serviceable measuring element
     • Suitable for horizontal and vertical mounting
     • Hydraulic performance in accordance with EEC 75/33


Technical Data
                                                 DN 50 65 80 100 125 150 200 250 300 400 500
Q max Maximum Flow Rate                         m³/h 30 50 80 120 200 300 500 800 1200 2000 3000
                                                                                                      Dimensions
Qn        Nominal Continuous Flow Rate           m³/h 15 25 40 60 100 150 250 400 600 1000 1500
Qt        Transitional Flow Rate with ±2% error I/h    2   4   4    6   6    12 12 15 15 50 80
Q min Minimum Flow Rate with ±5% error            I/h 0.55 0.6 0.7 1.2 2.5   3   5    10 12 30 45
          Starting Flow                           I/h 0.2 0.25 0.25 0.3 0.6 1.7 1.8   3   9   16 20


Head Loss Diagram




                                                                                                                                   DN 50 65 80 100 125 150 200 250 300 400 500
                                                                                                      Length                       mm 200 200 225 250 250 300 350 45 500 800 900
                                                                                                      Height “h” centre line to lid mm 150 150 150 150 150 210 210 300 300 350 390
                                                                                                      Height centre line to base   mm 82.5 93 110 110 125 143 170 205 230 290 360
                                                                                                      Height “g” centre line to top mm 360 360 360 360 360 420 420 660 660 750 840
                                                                                                      Overall dimension “b”        mm 175 175 175 175 175 215 320 320 320 320 320
                                                                                                      Weight                       mm 12 15 16 18 26 39 52 117 117 244 376




                                                                                                                                                                         3
                  pulsed output meters
Pulsed Output Meter Range
We have a range of meters from 1/2” to 2” in size, which can be used in conjunction with a
building measurement station:
     • Meter equipped with an impulse emitting device
     • Wide range of pulsed outputs
     • USLF/DALF models, single jet - dry dial - for cold water up to 30°C
     • USLC/DALC models, singles jet - dry dial - for hot water up to 90°C
     • IALF/OALF models, multi jet - dry dial - for cold water up to 30°C
     • IALC/OALC models, multi jet - dry dial - for hot water up to 90°C


Technical Data
                                                  DN      13      20        25    30     40      50
Q max Maximum Flow Rate                           m /h
                                                    ³      3      5         7     10     20      30
Qn        Nominal Continuous Flow Rate            m³/h    1.5    2.5        3.5   5      10      15      Dimensions
Qt        Transitional Flow Rate with ±2% error I/h      120     200       280    400    800   3000
Q min Minimum Flow Rate with ±5% error             I/h    30      50        70    100    200     450


Number of Litres Per Pulse
                                                                                                                           Max Voltage Supply
0.25 0.5          1      2.5      5      10       25      50     100        250    500    1000
                                                                                                            Length of      appliable to the circuit:
                                                                                                          the screened     30V - 0.2A
                                                                                                         cable supplied:
                                                                                                             200cm




Remote reading (in combination with a remote display or a computerised reading system, it is
possible to collect and process water consumption data in multi apartment buildings, where the
access to water meter is often difficult, or wherever central reading of several meters is required.




Rate of flow control: by a suitable electrical output and with addition of electronic instrumentation,
several operations are possible, such as valve and pump control, warning systems, etc.,
according to different pre-selected rate of flow valves.




  4
                                                                            tagus
Tagus Range
The Tagus range of 1/2” and 3/4” meters is certified by the DTI as suitable for applications such
as CLASS D meters, which benefit from the following features:
     • DTI approved
     • WRC approved
     • Suitable for use with cold water up to 30°C
     • Suitable for horizontal and vertical mounting
     • Magnetic transmission
     • Air-tight roller mechanism


Technical Data
                                                             1/2”           3/4”            1”
Q max Maximum Flow Rate                          m /h ³       2.0            5.0            7
Qn        Nominal Continuous Flow Rate           m³/h         1.0            2.5           3.5      Dimensions
Qt        Transitional Flow Rate with ±2% error I/h          11.5          28.75          40.25
Q min Minimum Flow Rate with ±5% error               I/h      7.5          18.75          26.25
          Dial Reading                               m³    0-10000        0-10000        0-10000
          Maximum Working Pressure                Bar         16             16             16




                                                                                                     D   Thread Size   BSP   1/2”    3/4”    1”
                                                                                                     L1 Length         mm    134     190     260
                                                                                                     H1 Height         mm    36      44      59
                                                                                                     H2 Height         mm    138    138.50   155
                                                                                                     H3 Height         mm    102     112     133
                                                                                                     L4 Width          mm    90      90      117
                                                                                                         Weight        Kg    1.2     1.54    3.15




                Airfield Industrial Estate, Hixon, Staffs, ST18 0PF