Carlson TCP Relay User Manual Page by bzh37299

VIEWS: 20 PAGES: 8

									 Carlson TCP Relay User Manual  Page 1 




Contents 
1.  Hot List – Key points you need to know 
        We know you hate to read manuals, but read this Hot List! 

2.  Introduction to  TCP Relay 
         Supported devices 

3.  Installation instructions: 
         Explorer 
         AllegroCX 

4.  TCP Relay Utility 
       Workflow Overview 
       Instructions



Carlson Knowledge Base located at:          http://update.carlsonsw.com/kbase_main.php 
 Carlson TCP Relay User Manual  Page 2 

Hot List – TCP Relay 
    1.  An internet connection must be established before using TCP Relay.  Use 
        ActiveSync, WiFi, internal GPRS modem, or external Bluetooth Phone with 
        GPRS modem functions. 
    2.  TCP Relay must have an active SurvCE serial number to run and to register.  TCP 
        Relay registers once with our office server to verify an Active SurvCE serial 
        number and device ID.  Although TCP Relay is free, it is not intended to be used 
        without SurvCE. 
    3.  TCP Relay does not configure the rover com ports or internal settings.  Continue 
        to use SurvCE to configure the GPS Rover and then use TCP Realy to deliver the 
        TCP/IP base data to the rover. 




Introduction of TCP Relay 
               This utility routes GPS reference station data through the data collector’s 
internet connection and out to the GPS rover, via a com port.  GPS reference stations post 
data such as RTCM or CMR messages  in a TCP/IP format.  This utility  accepts that IP 
data and converts it into serial port data to be linked to the rover.  The utility will function 
in NTRIP, GPUID, and username required reference networks. 

        SurvCE controls if the rover GPS receiver provides a GGA position message back 
to the base network.  Contact your network manager to be sure you know what format the 
local network is using, and if a GGA message is needed from the rover. 
Example: Use an Explorer 600+ with an Enfora card and connect to the internet.  Then 
designate the IP address of your base, 65.173.143.132 port 7032 and that data will be 
routed from the internet Enfora card out the Com 1 of the Explorer to the rover GPS 
receiver, port D.  The rover receiver does its RTK calculations and then sends a fixed 
position out its own Bluetooth port to Com 6(BT) of the Explorer 600+.  No airlink 
modem and no external cell phone and BT needed. 

    1.  Use this utility on the 600+ and Enfora card to connect to a GPS internet base 
        station. 
    2.  This can work with NTRIP and/or username and password GPS networks. 
    3.  Mix and match GPS brands as bases and rovers.  Example, take a Topcon rover 
        onto a Trimble VRS network. 
    4.  No need for a separate cell phone. 
    5.  No need for an external Airlink modem connected to the receiver.




Carlson Knowledge Base located at:             http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 3 
Installation instructions: 
Explorer ­ 
      1.  Copy netcf2.0.cab onto System CF and double tap it there. 
      2.  Then Save Reg 
      3.  Then copy CarlsonUtilities.cab onto SystemCF and double tap. 
      4.  Then Save Reg 
      5.  You may want to make a folder under SystemCF, called “Copy To 
          SystemCF”.  Put copies of these two cab files into the folder. 
      6.  In order for the cab file to install correctly, it must be directly in SystemCF 
          before double tapping. 

AllegroCX – 
       1.  Copy netcf4.2.cab onto C_Drive and double tap it there. 
       2.  Then Save System. 
       3.  Then copy CarlsonUtil_allegroCX.cab onto C_Drive and double tap. 
       4.  Then Save System 
       5.  You may want to make a folder under C_Drive, called “Copy To C_Drive”. 
           Put copies of these two cab files into the folder. 
       6.  In order for the cab file to install correctly, it must be directly in C_Drive 
           before double tapping. 

TCP Relay Utility 
Overall Workflow – The base GPS data will be coming from an internet base station, into 
the data collector and back out the data collector to the GPS Rover then the position 
solution will come back to the data collector, from the GPS Rover, to be stored or used 
by SurvCE.  Therefore, you must follow the following order. 

Configure the GPS rover with traditional SurvCE methods.  Be sure to identify the radio 
port as the one where the TCP Relay cable is coming from.  Match the baud rates inside 
SurvCE to TCP Relay.




Carlson Knowledge Base located at:            http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 4 
This example is for a Topcon rover with a cable from the Explorer Com 1 to the Hiper 
port D, and a baud rate of 38400 set here and later in TCP Relay.  The base data is CMR+ 
format. 




If the base network requires a GGA message to be returned to the network, be sure to 
check the appropriate box as seen below in Configure Rover. 




TCP Relay Instructions 
   1.  TCP Relay can be initiated from the desktop icon, or from the Programs Menu – 
       Carlson Utilities.




Carlson Knowledge Base located at:          http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 5 

The screen below shows Carlson TCP Relay in the Programs menu. 




2.  The first time the program runs,  you will be prompted for an active SurvCE serial 
number.  Enter a SurvCE serial number.  Example:  52403­99530601­431830.  The 
device and SurvCE serial number will register with our server.  Therefore, you must have 
an internet connection to register TCP Relay.




Carlson Knowledge Base located at:         http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 6 

3.  After TCP Relay is registered the following screen will appear. 




4.  Select the Friendly Name drop down arrow, and select New.  Type in a name that you 
will recognize to describe the base network, or individual Base.  Example: 
Mays_RTCM, or NCDOT VRS_CMR.




Carlson Knowledge Base located at:           http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 7 

5.  Select the Connection Type,  Generic TCP, NTR­IP, SpiderNet (GPUID) and fill in 
the blanks with the network information.  Once the fields are filled, press the Save button. 




6.  Before saving, you will be prompted to fill in additional information about the base 
network.  This data is optional.  Press Done when complete.  Then OK, to move on to the 
com port settings.




Carlson Knowledge Base located at:           http://update.carlsonsw.com/kbase_main.php 
Carlson TCP Relay User Manual  Page 8 

7.  The following com port settings need to be setup to match how the rover GPS receiver 
is programmed.  The details below assume you have cable connection out Com1 up to the 
GPS rover at a baud rate of 38400.  The rover GPS unit should be programmed to accept 
the base corrections at a baud rate of 38400 and from whatever com port you plug the 
cable into. 




8.  Press the Start Relay button to begin the communication.  The button will stay 
highlighted and you can hten MINIMIZE the program using the minimize button in the 
upper right.  (Do Not press the X button, that will end the TCPRelay) 


9.  Return back into SurvCE and verify in Monitor Skyplot that you have a fixed solution.




Carlson Knowledge Base located at:          http://update.carlsonsw.com/kbase_main.php 

								
To top