temperature sensor, temperature sensors, temperature probes, rtd sensors, sonde thermocouple, temperature measurement, thermocouple sensor, platinum resistance, thermocouple probes, industrial instrumentation products, thermocouple wire, test & measurement, humidity sensor, high quality, k thermocouple
-
Stats
- views:
- 81
- posted:
- 1/18/2010
- language:
- French
- pages:
- 2
Document Sample


S4000
SONDES A THERMOCOUPLE
THERMOCOUPLE SENSORS
FONCTION FUNCTION
Un thermocouple est composé de 2 fils de nature différente A thermocouple is made of 2 different nature wires welded in
soudés en un point. Cet ensemble génère une force a common point. This couple generates an electromotive
électromotrice (tension) mesurée aux extrémités libres power (voltage) measured at the loose leads directly related
directement liée à la température du point de jonction. La to the temperature of the common point. The
correspondance Tension / Température est donnée par des correspondence between Voltage / Temperature is given by
tables de références correspondant à chaque type de couple. references tables corresponding to each type of couple.
CARACTERISTIQUES TECHNICAL DATA
Elément de mesure Thermocouples types : J, K, T Measuring component Thermocouples types : J, K, T
Type J : -100… +1200°C Type J : -100… +1200°C
Type K : -180… +1372°C Type K : -180… +1372°C
Type T : -200… +400°C Type T : -200... +400°C
Précision Classe 1 suivant IEC 60584 Accuracy Class 1 according to IEC 60584
Matière sonde inox 316L Sensor material stainless steel 316L
Φ sonde 6, 8, 9 mm ... Sensor Φ 6, 8, 9 mm …
Longueurs de sonde 50, 100, 150, 200 mm, … Sensor length 50, 100, 150, 200 mm, …
Elément sensible fixe ou interchangeable Sensor type fixed or interchangeable
Raccord process sonde lisse ou filetée Process connection smooth or threaded probe
Filetage : ½'' GM, ½'' NPTM, … threading : ½'' BSPM, ½'' NPTM, ...
raccord fixe ou tournant coulissant fixed or sliding connection
Température ambiante -40°C…+80°C Ambient temperature -40°C…+80°C
Température fluide -50°C…+800°C (plongeur Inox 316L) Process temperature -50°C…+800°C (316L St. St. bulb)
Subject to modifications due to technical advances / Soucieux d'améliorer nos produits, nous nous réservons le droit de réviser sans préavis les caractéristiques de nos produits
autres conditions/matières sur demande other conditions/materials on request
Raccord électrique bornier interne en céramique Electrical connection ceramic internal terminal block
sur convertisseur On converter
Tête de raccordement B – IP 54 Connection head B – IP 54
DAN – IP 54 DAN – IP 54
DANV – IP65 DANV – IP65
MA – IP 54 MA – IP 54
ADF – IP 66 ADF – IP 66
Presse étoupe ISO M16 (autres sur demande) Cable gland ISO M16 (others on request)
Têtes revêtues époxy, autres types ou revêtements sur demande Epoxy coated heads, other head types or coating on request
CERTIFICATIONS CERTIFICATIONS
Versions ATEX ATEX versions
Sécurité Intrinsèque EN 50014 et EN 50020 Intrinsically Safe EN 50014 and EN 50020
EEx ia IIC T6 - IP 6X - T80°C EEx ia IIC T6 - IP 6X - T80°C
Ex II 1 G et/ou 1D Ex II 1G and/or 1D
Antidéflagrante EN 50014 et EN 50018 Flameproof EN 50014 and EN 50018
EEx d IIC T6 - IP 6X - T80°C EEx d IIC T6 - IP 6X - T80°C
Ex II 2 G et/ou 2D Ex II 2G and/or 2D
(si équipée d’une tête ADF uniquement) (must be used with a flameproof head)
OPTIONS OPTIONS
FC-S4000-FREN-30-11-2006
Thermocouples couples type N, B, E, L, R, S, U. Thermocouples couples type N, B, E, L, R, S, U.
Autres plaque inox, sonde à double élément, Others St. St. tag plate, special process
raccord process spécifique, autres types de têtes de raccordement, connection, other types of connection head, bulb material, cable
matières de plongeurs, presse étoupe, connection électrique, PV gland, electrical connection test reports,...
d’essais,...
GEORGIN France Tel : 33 (0)1 46 12 60 00 Fax : 33 (0)1 47 35 93 98 regulateurs@georgin.com
GEORGIN Belgium Tel : 02 735 54 75 Fax : 02 735 16 79 info@georgin.be
TYPE DE MONTAGE - ENCOMBREMENT (mm) / MOUNTING TYPE – DIMENSIONS (mm)
Tête ADF Tête type DAN-V
Flame Proof Head DAN-V bulb head
115 113
65 61
79
118
Mini tête type MA Tête type B
MA mini-head B bulb Head
56
34 80
52 49
72
Longueur utile / Probe length : LU (mm) Longueur / Length : LU (mm) Extension (mm)
Ø (mm)
Ø (mm)
G1/2"
Sonde lisse Sonde raccord G1/2" + réhausse
Smooth probe 1/2"BSPM + extension probe
Longueur utile / Probe length : LU
Ø (mm) ( )
G1/2"
Sonde raccord G1/2" fixe
1/2"BSPM connection probe
Pour un raccord ½’’, inclure 15mm de filetage dans la Longueur Utile (LU).
For an ½’’ process connection, please include a 15mm threat length in the sensor length (LU).
S4000 A DE RA F 1 9 B 0 T
ELt SENSIBLE
PRESENTATION RACCORD Φ SONDE Rehausse Convertisseur
VERSION THERMOCOUPLE TYPE SENSING LU (mm)
HEAD CONNEC. CONNEXION SENSOR Φ Extension Converter
ELEMENT
TJ J (-100 +1200°C) F Fixe / Fixed sonde lisse 6 6 mm A 50 Sans Sans convertisseur
0 0
BE B TK K (-180 +1372°C) I Interchangeable smooth probe 8 8 mm B 100 without 0 Without converter
DE DAN TT T (-200 +400°C) 1/2"GM 9 9 mm C 150 1 50 mm Avec convertisseur
A Standard 1 1/2"BSPM 2 100 mm T Converter equipped
DV DAN-V spécial D 200
2 1/2"NPTM Z
ME MA spécial special E 250 3 150 mm
ZZ 1/2"GM
special F 300 autre
3 1/2"BSPM Z
BE B G 350 other
I EEx ia DE DAN 4 1/2"NPTM H 400
DV DAN-V 1/4"GM J 450
5 1/4"BSPM K 500
D EEx d XE ADF/FP 6 1/4"NPTM 1 0…100
1/4"GM 2 101…200
spécial 7 1/4"BSPM 3 201…300
ZZ 8 1/4"NPTM
special 4 301…400
spécial autre
Z special Z
other
:
Tournant coulissant
Sliding connection
GEORGIN France Tel : 33 (0)1 46 12 60 00 Fax : 33 (0)1 47 35 93 98 regulateurs@georgin.com