Virtual Chart Recorder by oss17616

VIEWS: 84 PAGES: 4

									                                                                                                                         Virtual Chart Recorder
Temperature & Relative Humidity
      Web Server
      Get Alarms by Email or
      Text Message
      No Special Software Required
      iTHX-SD: Record Years of
      Data on Popular SD Cards




 Chart
 Address http://192.168.1.200



                         Readings        Chart                 Web Link              Setup

    High 150.0 / Low 78.0                     Recording: ON                                        High 78.0 / Low 25.0
    Max. 130.1 / Min. 95.9                                                                         Max. 69.9 / Min. 30.1
    Temperature                    108.2 F                                         50.8 %                     Humidity
      200                                                                                                            100




      20.0                                                                                                          10.0
      C/Div                                                                                                         %/Div


                                                                                                                                      $
                                                                                                                                        395
                                                                                                                                          iTHX-SD
     0                                                                                                               0                                            $
    Thu Sep 16 08:00:00 PDT 2009

    Data Source:           Live

    Alarm Relay Set Points: Bold
                                        X-axis:
                                                      1 Hour/Div

                                                       1 Day

                                        Y-axis (left): Temperature   Style: Bold
                                                                                             Thu Sep 17 12:05:07 PDT 2009

                                                                                                      Save Chart
                                                                                                      Print Chart
                                                                                                                                                                   295iTHX-W
                                        Y-axis (right): Humidity     Style: Bold
 Help[?]




                                                                             $
                                                                                   295
                                                                                    iTHX-2                                         The OMEGA® iTHX transmitter let’s you monitor
                                                                                                                                   and record Temperature, Relative Humidity and
                                                                                                                                   Dew Point over an Ethernet network or the Internet
                                                                                                                                   with no special software except a Web Browser.
                                                                                                                             The iTHX serves Active Web Pages to display real time
                                                                                                                            readings, display charts of temperature, humidity, and
                                                                                                                            dew point or log data in standard data formats for use in
                                                                                                                            a spreadsheet or data acquisition program such as Excel
                                                                                                                            or Visual Basic.
                                                                                                                            The virtual chart viewed on the web page is a JAVA™
                                                                                         FCC-B                              Applet that records a chart over the LAN or Internet in
                                                                                                                            real time. With the iTHX, there is no need to invest time
                                                                               ®                                            and money learning a proprietary software program to log
                                                                                                                            or chart the data.
Adjustable Charts                                                                                                          A second probe can be added at the
Chart scales are fully adjustable on                                                                                       time of purchase or in the future.
the fly. For example, the chart can                                                                                        OMEGA offers a choice of industrial
display one minute, one hour, one                                                                                          probes in 2” and 5” lengths, and a
day, one week, one month or one                                                                                            wand style for ambient indoor
year. Temperature and humidity can                                                                                         applications. A simple DB-9 “Y”
be charted across the full span                                                                                            connector is available for adding a
(-40 to 124°C, and 0 to 100% RH)                                                                                           second probe to model iTHX-W and
or within any narrow range such as                                                                                         iTHX-SD. No connector is required to
(20 to 30°C).                                                                                                              add a second probe to the DIN rail
When a second sensor is added,                                                                                             mounted iTHX-2.
users can select a chart that records                                                                                      Award-winning Technology
channel 1, channel 2 or the                                                                                                The OMEGA iTHX is simple to install
difference of the two channels.                                                                                            and use, and features OMEGA’s
                                                                                                                           award-winning iServer technology
Chart
Address http://192.168.1.200
                                                                                                                           that requires no special software
                                                                                                                           except a Web Browser.
                        Readings        Chart                 Web Link              Setup                                                                             NEW iTHX-SD with SD Flash
   High 150.0 / Low 78.0                     Recording: ON                                        High 78.0 / Low 25.0
                                                                                                                           The iTHX connects to an Ethernet
   Max. 130.1 / Min. 95.9                                                                         Max. 69.9 / Min. 30.1                                               Memory Card and LCD Display
                                  108.2 F                                         50.8 %
   Temperature                                                                                               Humidity
                                                                                                                           Network with a standard RJ45
     200                                                                                                            100
                                                                                                                           connector and sends data in                The OMEGA model iTHX-SD with
                                                                                                                           standard TCP/IP packets. It is easily      LCD display, adds several valuable
     20.0                                                                                                          10.0
                                                                                                                           configured with a simple menu using        features in addition to the backlit
     C/Div                                                                                                         %/Div
                                                                                                                           a Web Browser and can be                   local display of temperature and
                                                                                                                           password protected.                        humidity.
    0                                                                                                               0      From within an Ethernet LAN or over
   Thu Sep 16 08:00:00 PDT 2009                      1 Hour/Div                             Thu Sep 17 12:05:07 PDT 2009
                                                                                                                                                                      The iTHX-SD comes complete with
   Data Source:           Live         X-axis:        1 Day                                          Save Chart
   Alarm Relay Set Points: Bold        Y-axis (left): Temperature   Style: Bold                      Print Chart
                                                                                                                           the Internet, the user simply types its    a removable 2 GB SD Flash Memory
                                       Y-axis (right): Humidity     Style: Bold
Help[?]                                                                                                                    IP address or an easy to remember          card that can store up to seven
                                                                                                                           name such as "Cleanroom5" or               years of readings taken at ten
                  iTHX-SD Adjustable Chart                                                                                 "ServerRoom" in any Web Browser,           second intervals.
                                                                                                                           and the iTHX serves a Web Page             The data recorded on the SD card
Display and Chart Two Channels                                                                                             with the current readings.                 can be read with a standard card
The iTHX transmitters come complete                                                                                        Industrial Probes:                         reader or remotely over an Ethernet
with a temperature and humidity                                                                                                                                       network or the Internet.
                                                                                                                           iTHP-5, iTHP-2
probe for measurement of a single
                                                                                                                                                                      With data being recorded on the SD
location. With the addition of a second
                                                                                                                                                                      card, a failure on the Ethernet
probe, the iTHX transmitter can
                                                                                                                                                                      network will not interrupt the data
measure and display temperature,
                                                                                                                                                                      recording.
humidity and dew point in a second
location up to ten feet away.                                                                                                                                         Alarm Relays
                                                                                                                                                                      The iTHX-SD features two 1.5 Amp
Read Sensor
           http://206.29.25.26
                                                                                                                                                                      relays. With the easy Web-based
                                                     Title                                                                 Email Alarms                               setup page, the two relays can be
 Temperature                                                        76.37 F
                                                                                                            Both
                                                                                                                           All OMEGA iTHX models that are on          programmed for any combination of
                                                                                                            Both



 Humidity                                                           59.66 %
                                                                                                            Ch 1                                                      temperature or humidity, and high or
                                                                                                            Ch 2
                                                                                                                           a LAN that is connected to the
 Dewpoint                                                           59.99 F                                                Internet can trigger an alarm that can     low set points. The relays can also
                                                                                                                           be sent by email to a user or a            be programmed to remain latched
 CH2 Temperature                                                    75.29 F
                                                                                                                           distribution list anywhere in the world,   and require a manual reset if a limit

 CH2 Humidity                                                       47.73 %
                                                                                                                           including text messages to cell            is exceeded.

 CH2 Dewpoint                                                       53.42 F
                                                                                                                           phones and PDA’s.                          Battery Backup
                                                 Main Menu                                                                 Typical Applications                       The iTHX-SD comes with a universal
                                                                                                                           The iTHX is great for monitoring           100 to 240 Vac power adapter.
          Reading 2 Sensors on iTHX-W                                                                                      temperature + humidity in                  A standard 9 Volt Alkaline battery
                                                                                                                           applications such as: clean rooms,         (also included) allows the device to
The transmitter can display and                                                                                            computer rooms, HVAC systems,              log data for up to 2 days without
chart absolute measurements in                                                                                             pharmaceutical and food processing         external ac power.
both locations, or a differential                                                                                          and storage, hospitals, laboratories,
measurement between the two                                                                                                semiconductor fabs, electronic
locations. The second probe                                                                                                assembly, warehousing, museums,
requires no change to the basic                                                                                            manufacturing, green-houses, farm
iTHX transmitter hardware.                                                                                                 animal shelters, and many more.

                                                                                                                                              2
                                                           Temperature + Humidity
                                                                                                                                               Sensors
Sensor Specifications                       LCD Display (iTHX-SD)                                                                              Address http://192.168.1.200


Relative Humidity (RH)                      16 Digits 6mm (0.23”)
                                                                                                                                                              Readings          Chart           Web Link          Setup
                                                                                                                                                                           Date and Time Server Sensors Alarm Relays
Accuracy/Range: ±2% for 10 to 90%;                                                                                                             Overview             Reading 1
±3% for 5 to 10% and 90 to 95%;             SD Flash Memory Card (iTHX-SD)                                                                     Network              Description Temperature                     Unit C                        Display
                                                                                                                                               Configuration        End Character 0d                  0x        Display Format T000.0C        Offset 0.0
                                            2GB card: 8 months of data storage                                                                 Management
±4% for 0 to 5% and 95 to 100%                                                                                                                                      Reading 2
                                                                                                                                               Security
                                                                                                                                                                    Description Humidity                        Unit %                        Display
                                            at 1 second recording intervals or 7                                                               Recording
Non-linearity: ±3%                                                                                                                             System               End Character 0d                  0x        Display Format H00.0%         Offset 0.0
                                            years at 10 second intervals                                                                       Diagnostics          Reading 3
Hysteresis: ±1%RH                                                                                                                              Log Out              Description Dewpoint                        Unit C                        Display
                                                                                                                                                                    End Character 0d                  0x        Display Format D000.0C
Response Time: 8 seconds, tau 63%                                                                                                                                   Sampling Rate
                                            Relay Outputs (iTHX-SD)                                                                                                 One Sample per 10 seconds
Repeatability: ±0.1%
                                            Two Relays 1.5A @ 30 Vdc                                                                                                                                  Save Changes           Reset
Resolution: 0.1%, 12 bit
                                            Alarm Relays
Temperature (T)                             Address http://192.168.1.200
                                                                                                                                                    iTHX-SD Sensor Configuration
Accuracy/Range*                                            Readings         Chart     Web Link        Setup
                                                                             Date and Time Server Sensors Alarm Relays
                                                                                                                                               Device Setup
Wand Probe: ±0.5°C (±1°F) for               Overview             Relay 1              Temperature              Relay 2         Humidity
                                            Network                                                                                                   http://128.100.101.254

                                                                                                                                                                                           DEVICE SETUP
                                                                 Description          Alarm Relay 1            Description     Alarm Relay 2
5° to 45°C (41° to 113°F); ±0.5 to 1°C      Configuration
                                            Management           Status               Disable                  Status          Disable
                                            Security             Type                 Update                   Type            Update                                                     Display          Display       Remote      Remote End Char
( ±1° to 2°F) for 0° to 5°C and 45° to      Recording                                                                                          No. Device Name Reading                     Units           Format        Format          (HEX)       Offset
                                                                                      Clear Latch                               Clear Latch
                                            System                                                                                              1    Temperature        SRTF                F              decimal       TA00.00F          0D             000.00
70°C (32° to 41°F and 113° to 158°F)        Diagnostics          Set Point High 0.0                            Set Point High 0.0
                                            Log Out
                                                                                                                                                2        Humidity       SRH                 %              decimal       HA00.00%          0D             000.00
                                                                 Set Point Low 0.0                             Set Point Low 0.0
                                                                                                                                                3   Dewpoint      SRDF                      F              decimal       DA00.00F          0D             000.00
Industrial Probe: ±0.5°C ( ±1°F) for                             End Character 0x 0D                           End Character 0x 0D
                                                                                                                                                4 Ch2 Temperature SRTF2                     F              decimal       TB00.00F          0D             000.00
                                                                 Display                                       Display
                                                                                                                                                5 Ch2 Humidity SRH2                         %              decimal       HB00.00%          0D             000.00
5° to 45°C (41 to 113°F); ±0.5° to 1.5°C                                                                                                        6 Ch2 Dewpoint SRDF2                        F              decimal       DB00.00F          0D             000.00
                                                                           Record all alarm events on the flash memory        Retrieve
(±1° to 2.7°F) for -40° to 5°C and 45° to                                                    Save Changes         Reset                                                                      Title:

124°C (-40° to 41°F and 113° to 255°F)                                                                                                                                                        Terminal Server
                                                                                                                                                      TCP/UDP: TCP             Server Type: Continue            Number of Sockets:        Port: 02000
*Note: extended temperature range                                                                                                                                                Remote Access (Tunneling)
                                                                  iTHX-SD Alarm Relays                                                               Remote IP Address:                               Remote Port: 02000 Remote Access:
is for Ind. probe only, the iServer’s                                                                                                                                           0.0.0.0                                                         disable

                                                                                                                                                                                                       Update
operating temperature is 0 to 70°C                                                                                                                                                               Take Readings

                                                                                                                                                                          Click on device no. on left to modify device parameters.
Response Time: 5 to 30 seconds,             Embedded WEB Server                                                                                                                                   Main Menu
tau 63%                                     Serves WEB pages containing real-
Repeatability: ±0.1°C                       time data and live updated charts                                                                   iTHX-W and iTHX-2 Configuration
Resolution: 0.1°C, 14 bit                   within definable time intervals
Probe Physical Dimensions                   Readings                                                                                           Environmental
                                             Address http://192.168.1.200
Wand Probe iTHP-W                                                                                                                              Operating Temperature:
                                                               Readings             Chart       Web Link Setup                                 Unit: 0 to 70°C (32 to 158°F)
Probe length: Ø19 mm x 198 mm                                                                        HTML Java

                                                        Temperature                                                               23.0 C
(0.75" x 7.8")                                                                                                                                 Battery: -20 to 55°C (-4 to 131°F)
                                                        Humidity                                                                  47.3%
Cable length 152mm (6”) with DB9                                                                                                               ac Adapter: 0 to 40°C (32 to 104°F)
                                                        Dewpoint                                                                  11.0 C
Connector                                                                                                                                      Storage Temperature:
                                                        Alarm Relay1                                                              ON
Cable operating temp: 0°C to 80°C                                                                                                              -40 to 85°C (-40 to 185°F)
                                                        Alarm Relay2                                                              OFF
(32°F to 176°F)
                                                                                                                                               Power
                                                        Recording                                                                 ON
Industrial Probe iTHP-5, iTHP-2:
                                                                                                                                               Input: 9 to12 Vdc: iTHX-W, iTHX-SD;
Probe length: Ø16mm x 137mm or
                                                                                    Refresh 2                 Seconds        Auto Update       10 to 32 Vdc: iTHX-2
51mm (0.63” x 5” or 2”)
Housing material: SS316                                                                                                                        Safety Qualified ac power adapter:
Cable length 3m (10’) or 0.9m (3’)                                 Readings on iTHX-SD                                                           Nominal Output: 9 Vdc @ 0.5A
Cable operating temperature:                                                                                                                     Input: 100 to 240 Vac, 50/60Hz
-40°C to 125°C (-40°F to 257°F)                                                                                                                  included: iTHX-W, iTHX-SD
                                            Software                                                                                           Switching Power Supply sold
iServer Specifications                      OPC Server; macro for datalogging                                                                  separately: iTHX-2
Interfaces                                  in Excel program; compatible with                                                                  Battery: 9Vdc, Alkaline iTHX-SD
Ethernet (RJ45): Fixed or auto-             Windows operating systems                                                                          Packaging
negotiating 10/100BASE-T,                                                                                                                      Material: Steel metal case with wall
Auto MDI/MDIX: iTHX-SD;                                                                                                                        mount bracket: iTHX-SD; Valox 364
10BASE-T: iTHX-W, iTHX-2                                                                                                                       PBT case with wall mount bracket:
Sensor: Digital 4-wire (DB-9):                                                                                                                 iTHX-W; Polycarbonate case with
iTHX-W, iTHX-SD; removable                                                                                                                     DIN Rail mount: iTHX-2
8 position screw terminals: iTHX-2
Protocols
TCP, UDP, SNMP, SMTP, NTP,                                                                                                                                   NIST Traceable Calibration
ARP, ICMP, DHCP, DNS, HTTP,                                                                                                                                     Certificate available.
                                                                                                                                                         In compliance with ISO9001:2000,
and Telnet: iTHX-SD;                                        Datalogging Spreadsheet                                                                            ISO10012-1.1992(E),
TCP, UDP, ARP, ICMP, DHCP, DNS,                                                                                                                               ANSI/NCSL Z540-1.1994
                                                                                                                                                               and MIL-STD-45662A.
HTTP, and Telnet: iTHX-W, iTHX-2

                                                                                                        3
                                                                                               Mechanical Specifications

                 0.50 [12.7]   TYP




                                              2.13 [54.1] TYP
10.65 [270.4]




                                                                                 3.40 [86.4]
                                                                   3.50 [88.9]
                                                                                                                                                                                         iTHX-2




                                                                                                                                                            3.54" [90.2mm]
                3.25 [82.6]
                 0.75 [19.1] TYP
                                                                                                    3.38 [85.9]                             DIAG LINK ACT




                                                                                                                                         DC POWER IN

                2.42 [61.6]                                                                         2.60 [66.0]

                                                                                                                                          0.99"
                                                                                                                                                                                     4.53" [115mm]
                                                                                                                                        [25.1mm]
                                                                                                                                                                                             113 g (0.25 lbs) iTHX-2

                                                                   3.56 [90.3]

                                                                                 3.67 [93.1]
                                                                                                                                         iDRN-PS-1000
                                                                                                                                                       24Vdc Supply
                                                                                                                                                       Mounts to 35mm
                                                                                                                                                       DIN rails
                                                                                                                                                       Switching Power
                                                                                                                                                       Supply powers up
                                             Dimensions are in
                                             inches with
                                                                                                                                                       to 7 units
                                             millimeters in [ ].

                                                                                                                                        Replacement Probes with Calibration Certificate
                                                                                                                                        available, just add: “- CAL-3-HU”

                         iTHX-SD                                                                             iTHX-W                     Optional Probe Caps
                         389g (0.86 lbs)                                                                     180 g (0.4 lbs)            shown
                                           0.12 [3.0]                                                                                       iP-PC

                                                                                                                                                                             iP-SC
                                                                           1.08 [ 27.4]                                                                              Standard
                                           1.44 [ 36.6]                                                                                 No need to take your unit out of service to get
                                                                                                                                        re-calibrated, order a calibrated probe instead.
                                                                0.10 [2.54]

Model No.   Description                                          Price                                                Model No. Description                                                                   Price
iTHX-SD     iServer MicroServer™ for Temp + Humidity and Dew-                                                         iTHX-2    iServer MicroServer™ for Temperature + Humidity
            point, LCD Display, 2GB SD Flash Memory Card,                                                                       and Dew Point                                                                   295
            2 Relay Alarm, Battery Back-up                        395                                                         * Standard Industrial Probe 137mm (5”), Cable 3 m
iTHX-W      iServer MicroServer™ for Temperature + Humidity and                                                                 (10 ft), Stripped Wire Leads. No Entry required                                 N/C
            Dew Point                                             295                                                        -2 Industrial Probe 51mm (2”), Cable 0.9 m (3 ft) with
          * Standard 203 mm (8”) Wand Probe, Cable 152 mm                                                                       Stripped Wire Leads. Substitution for 5” Probe                                  N/C
            (6”) with DB9 Connector. No Entry required            N/C                                                 Accessories
         -2 Industrial 51 mm (2”) Probe, Cable 0.9 m (3 ft) with                                                      iTHP-2        Industrial Probe 51 mm (2”), Cable 0.9 m (3 ft)
            DB9 Connector. Substitution for Wand Probe              15                                                              with Stripped Wire Leads. *1                                                115
         -5 Industrial 137 mm (5”) Probe, Cable 3 m (10 ft) with                                                      iTHP-5        Industrial Probe 137 mm (5”), Cable 3 m (10 ft)
            DB9 Connector. Substitution for Wand Probe              25                                                              with Stripped Wire Leads. *1                                                125
Accessories                                                                                                           iDRN-PS-1000 Power Supply (switching), 95 to 240 Vac input,
iTHP-W-6    Replacement 203mm (8”) Wand Probe, Cable 152mm                                                                          24 Vdc output @ 850 mA (powers up to 7 units)                               150
            (6”) with DB9 Connector                               100                                                 RAIL-35-2     2 m (6.5 ft) section of 35mm DIN rail                                        15
iTHP-2-DB9 Industrial 51 mm (2”) Probe, Cable 0.9 m (3 ft) with
            DB9 Connector*1                                       115                                                 Common Accessories                                                                      Price
iTHP-5-DB9 Industrial 137 mm (5”) Probe, Cable 3 m (10 ft) with                                                       iP-PC          Polyethylene Probe Cap, for wet environments                              N/C
            DB9 Connector*1                                       125                                                 iP-SC          Porous Stainless Steel Probe Cap, 5um porosity,
DB9-Y       DB9 “Y” Connector Adapter for 2 Probes with DB9                                                                          for dusty and pressurized (< 35 psi) environments                            25
            Connector                                               25                                                CAL-3-HU       NIST Traceable Calibration Certificate. Three (3)
DB9-CA-3 Extension Cable, 0.9 m (3 ft) with DB9 Connector           15                                                               Humidity Points of 25%, 50%, 75%, one temp-
                                                                                                                                     erature 25°C, for new units                                                150
Ordering Examples for iTHX-SD with LCD display, SD card, 2 relay alarm,

                                                                                                                      CT485B-CAL-KIT Calibration Kit, 33% and 75% RH Standards
battery back-up and wand probe: iTHX-SD = $395.                                                                       CAL-3-DUAL Same as CAL-3-HU, for new units with 2 probes                                  175
For dual channel iTHX-2 with additional industrial 5" probe and 10' cable:                                                                                                                                       75
iTHX-2 + iTHP-5 + iDRN-PS-1000. $295 + 125 + 150 = $570.
For Calibrated Replacement Probe, with Certificate: iTHP-W-6-CAL-3-HU. $100 + 50 = $150.
*1 Other lengths of cable (up to 40 ft) are available, please contact our Sales Department. * Volume discounts are available.


                                                                                                                  4

								