3 Tips for Continuous Blending by gvz34939

VIEWS: 8 PAGES: 16

									3 Tips for Continuous Blending

   Creating accurate, automatic and safe 
            feeding applications

                    Carlos Moya
         Sales Engineer, Hardy Instruments



                                www.hardyinstruments.com
We’ll Review Feeding in General Then 
             Some Tips
• What is Continuous Blending?
• What Does a Continuous Blending Application 
  Look Like?
• 3 Tips to Make a Continuous Blending 
  Accurate, Automated and Safe




                           www.hardyinstruments.com
     A Basic Review of Feeding
• Continuously feeding an ingredient is called for 
  when batching can’t be done or if continuous 
  throughput is desired
• Gravimetric, loss‐in‐weight feeding is about 
  weight
• Rates are Weights over time, over a time base
• Control an output based on rates, we use;
  – PI loop, 
  – mechanical and electronic filtering

                              www.hardyinstruments.com
  Motor, Sensors and Controllers are 
      Part of a Feeding System
• Closed Loop means relying on feedback for 
  control
• Here’s an open‐loop system….

                        Controls         Feeder




                             www.hardyinstruments.com
           Rate Control Application Review
                                              ALARM

      • Let’s look at a closed‐loop control                   REFILL
                                                              VALVE



                 E-STOP
                 BUTTON
      PC



                                        RELAYS
                                        OUT
                           SWITCH
PLC                        INPUTS

                                                      MOTOR
                    ETHERNET                          SPEED

               COMM NETWORK
                                                  WEIGHT
            MASTER
            INSTRUMENT         ANALOG IN


                                               www.hardyinstruments.com
Here’s a Pellet Feeding System




                  www.hardyinstruments.com
       Tip #1: Select the Right Scale 
               and Time base
• Choose the right scale
   – Scale capacity = factor x Minimum Rate x 2
   – (Factor) 1 mV/V = 125, 2 mV/V = 175, 3 mV/V = 250
   – Rates = (weight1‐weight2)/time base produces feed rates 
     in lbs./min, (minute/time base) 
• Time base should be long enough to see a change in 
  weight, TWICE. 
   – Calculate minimum weight change.
      • Scale Capacity/30,000


                                   www.hardyinstruments.com
    Tip #1: Examples of Proper Scale 
               Calculations
• I want to feed at 1 lbs./min, I have 300 lbs of 
  equipment and want to feed 50 lbs max. I 
  have 1 mV/V load cell
  – Minimum capacity=125*1lbs/min*2=250 lbs
  – Dead load + Live load = 300+50 = 350 lbs
• To feed 1 lbs/min, with a 30,000 lbs scale: 
  resolution=30000/30000= 1 lbs, timebase>2 
  minutes

                              www.hardyinstruments.com
Tip #1: Proper Timebase Example
• Time Base must be long enough to see a clear loss in weight.
• The amount of time between reads is set by the Time base.  
• The difference between T1 and T2 equals the Actual rate of 
  change
• The variations in the LIW actual is a product of the Averages, 
  Waversaver, material consistency, and feeder mechanics.
                           GAIN In
                           Weight

                                     LIW       REC
                                     actual   Limits

                     LIW
                                                Set Point
               T1   T2     T2                     LIW
                    A      B

                                     www.hardyinstruments.com
   Tip #2: Refill Automatically While 
                  Feeding
• Truly automate your system by refilling while 
  feeding – saves time & keeps dead load small
• Refilling is a disturbance to sensor
• Open‐loop while refilling can cause errors
• Be smart about being open‐loop during refills




                            www.hardyinstruments.com
  Tip #2: Anticipate Disturbances and 
  Forces While Feeding and Refill Fast
• Reduce the amount of time refilling 
• Create a history from your refilling cycle and 
  use it!
• Keep refilling levels consistent for your 
  process.  Change in product pressure is the 
  main reason to control the rate.



                             www.hardyinstruments.com
   Tip #3: Use Alarms to Stay Safe
• Automating your process can be safe if you 
  create alarms
• Have shutdowns that are automatic 
• Prevent liquefying
• Prevent blocking
• Alert if feeders, motors or valves malfunction



                            www.hardyinstruments.com
 Continuous Blending Can be Accurate, 
         Automated and Safe 
• Weight and Time are keys to accuracy with continuous 
  blending: Scale calibration and accuracy is the key 
  factor above all the rest.
• Refilling operations can be automated and seamless if 
  you’re smart
• Have your process protect itself by detecting 
  dangerous conditions and have automatic counter 
  measures planned for those conditions.



                                www.hardyinstruments.com
 May We Suggest the HI 4060 RC…
• Smarts: The HI 4060 RC has control, 
  disturbance and refill algorithms
• Convenience: the HI 4060 has Automatic Rate 
  calibration to match to any feeder
• HI 4060 is loaded with I/O
                 F(x) = Kp*E(x) + KI*E(x)




                                  www.hardyinstruments.com
            More Solutions…
• Visit Hardy Instruments experts at booth #524
• My contact info:
                     Carlos Moya
          Sales Engineer, Hardy Instruments
               CMoya@HardyInst.com
         Work Phone: (858) 278‐2900 ext 1350




                               www.hardyinstruments.com
Questions?




       www.hardyinstruments.com

								
To top