Pressure gauge NG 100 with analogue output signal by variablepitch339

VIEWS: 21 PAGES: 2

									Pressure gauge NG 100 with analogue output signal
Application Measuring range Range of application Accuracy Dial Pointer Movement Case Window Liquid filling Protection EMC/CE For gaseous and liquid, low-viscosity, non-aggressive and aggressive media up to 60°C. 0,6 to 250 bar 2) For static pressure 100%, for dynamic pressure 90% of full scale Pressure gauge Cl. 1.0 acc. EN 837-1 Output signal 0.5% FS White, black scale acc. EN 837-1 Aluminium, black, EN 837-1 Stainless steel Bayonet lock, blow-out disc at rear (S1 acc. DIN EN 837-1) Multilaminated safety glass System design DRCG: no liquid System design DROG: Paraffin oil IP 54 (EN 60529 / DIN-VDE 0470-1) Higher protection class on request Conforms to EN 61326 emitted interference, class B Interference resistance: industrial requirement

Selection Chart
Ordering code System design Standard With dampening liquid Nominal size NG 100 Case Stainless steel 1.4301, bright drawn Structural shape Direct mounting, without flange Wall mounting, 3 brackets Panel mounting B Connection Radial Scale Standard Measuring element Stainless steel Special designs and auxiliary units For special designs, see chapter A25 For diaphragm seals, see chapter A4
Influence of ambient temperature on the output signal (in range from 0…100°C):

DRxG 101 / xxx.xxx Range DRCG DROG
3)

Teletransmitter, built-in Measuring element E E E E E E E E E E E E E E E E E E E E E E E Output signal 1) Ordering code Angle 270° 2-wire Ordering code: 3272 4 … 20 mA (rising) UB 10...30 V DC Load: (UB - 10V) / 20mA Ordering code: 3274 20 … 4 mA (falling) 3-wire Ordering code: 3291 0 … 20 mA (rising) 24 V DC UB 11,5...30 V DC Load: (UB - 12V) /0,02mA Ordering code: 3294 20 … 0 mA (falling)

Order number bar 015 025 035 045 055 065 075 085 095 105 115 125 135 145 305 315 505 515 525 535 545 555 F35 0… 0,6 0… 1,0 0… 1,6 0… 2,5 0… 4 0… 6 0 … 10 0 … 16 0 … 25 0 … 40 0 … 60 0 … 100 0 … 160 0 … 250 2) -0,6 … 0 -1,0 … 0 -1,0 … 0,6 -1,0 … 1,5 -1 … 3 -1 … 5 -1 … 9 -1 … 15 -1 … 24

101

2

1 3 4

1

1

(E)

33

Referenced to zero-point: Referenced to range:
Output signal characteristic:

≤0,02%/K typical ≤0,02%/K typical

≤0,04%/K max ≤0,04%/K max

Characteristic deviation: ≤ 0,5% of FS Repeatability: ≤ 0,05% of FS

Hysteresis: ≤ 0,1% of FS Response time: ≤ 3 ms

1) other output signals on request 2) larger pressure ranges on request (structural shape deviates, see D1.142) 3) order number for refrigerants see chapter A21 data sheet D1.155

www.baumerprocess.com Design and specification subject to change without notice.

Data sheet

A 21

D1.143 Page 1

Dimensions
Direct mounting (without flange), side electrical connection
ø101 50

24,5

10°

75

Panel mounting B, side el. connection 3 fixation elements, panel cut-out NG+2
(Process connection and connection box not shown)

Standard Connection box Ordering code 4710 Special design Plug Ordering code 4712

M20x1,5 S 22 G1/2A 17

87

Wall mounting, side elec. connection (3 brackets) This data sheet may only be reproduced in full.
10° ø128 ø116 6

Panel

8,5

60
ø4,8

76

ø132

Male connection standard G1/2 acc. EN 837-1 (matching flat washers acc. EN 837-1, see N 1890 D5.510.2, chapter A56) Option: 1/ 2–14 NPT (ordering code 0024) G1/4 A (ordering code 0002)

Special design Male connection Ordering code 4726 Accessories Connector J 70035.0020 (screw type) J 70035.0010 (crimp type)

www.baumerprocess.com Design and specification subject to change without notice.

Data sheet

A 21

D1.143 Page 2

DE/2007-03-21


								
To top