PHM3
Product Specifications
13 SEER PACKAGE HEAT PUMP UNIT
Single Phase, 24 to 54 MBtuh REFRIGERATION CIRCUIT
• All models are equipped with high efficiency scroll compressor. • High static indoor blower for mobile home and residential applications. • Thermostatic Expansion Valve (TXV) on select models controls refrigerant flow. • Higher Efficiency indoor motors on all models. • Factory charged with R--22 refrigerant.
BUILT TO LAST
• Galvanized-painted cabinet. One piece weather resistant top. Access panels for easy service. Side by side supply and return. • Triple--coated steel, consisting of a Polyester top coat, a urethane primer coat preceeded by an oxide pretreatment. • Drawn fan orifice and swept fan blades on all models except 5 ton for quieter operation. • The condenser coil has a sturdy wire inlet grille and UV rated vinyl mesh installed on the surface of the coil for additional protection. • Electronic Defrost Control on all models
EASY TO INSTALL AND SERVICE
• New drain pan cover and enclosed control box. • Combination electric cooling and heat, self contained for year-round comfort. • Externally--mounted gauge ports allow for more accurate reading of operating conditions while servicing. • Electrical controls located behind one exterior panel for easier maintenance. • Round duct flanges for easy flex duct connection.
ELECTRIC HEAT
• New electric heaters from 5 to 20 kw with new slip in installation location.
DEPENDABLE WARRANTY
• Standard five (5) year limited warranty on the compressor. • Standard five (5) limited warranty on all parts.
GENERAL PRODUCT SPECS (1 Phase - 60 Hz) Model Number PHM324K00A PHM330K00A PHM336K00A PHM342K00A PHM348K00A PHM354K00A COOLING Nominal S.E.E.R Capacity BTUH 24,000 13.0 29,000 13.0 36,000 13.0 40,000 13.0 45,000 13.0 52,000 13.0 HEATING Nominal Capacity BTUH @ 47° F 23,000 28,000 33,000 39,000 44,000 51,000 Voltage/ Phase/Hz 208/230--1--60 208/230--1--60 208/230--1--60 208/230--1--60 208/230--1--60 208/230--1--60 Unit Dimensions HxWxL 34 x 41 x 51 34 x 41 x 51 39--1/2 x 41 x 51 39--1/2 x 41 x 51 39--1/2 x 41 x 51 39--1/2 x 41 x 51 Ship Weight 300 329 382 392 390 440
E.E.R 11 11 11 10.6 10.2 9.7
HSPF 7.7 7.7 7.7 7.7 7.7 7.7
427 41 1101 01
4/17/06
UNIT SPECIFICATIONS
MODEL
Electrical Data: Condenser Data: 208/230 Volt Data (Phase--Hz) Max. Fuse / HACR Breaker Ampacity Coil Total Face Area (Sq. Ft.) Fins Per In. -- Rows Tube Dia. (In.) H.P. -- RPM Full Load Amps. Lock Rotor Amps. Size (Dia.) (In.) No. Blades / Pitch Total Face Area (Sq. Ft.) Fins Per In. -- Rows Tube Dia. (In.) Motor HP -- RPM Full Load Amps Type / Size CFM (Rated) PHM324K00A 1--60 PHM330K00A 1--60 PHM336K00A 1--60 PHM342K00A 1--60 PHM348K00A 1--60 PHM354K00A 1--60
25 20
11.35 18 / 2 3/8 1/8 -- 825 0.9 1.6 20
30 23.7
12.3 18 / 2 3/8 1/8 -- 825 0.9 1.6 20
35 29.1
15.6 18 / 2 3/8 1/4 -- 1100 1.5 1.7 20
40 31.7
15.6 18 / 2 3/8 1/4 -- 1100 1.5 1.7 20
45 38.8
13.2 18 / 2 3/8 1/4 -- 1100 1.5 3.2 20
50 39.7
15.6 18 / 2 3/8 1/2 -- 1100 3.0 3.2 20
Fan Motor: Fan: Evaporator Data Coil
3 / 34
4.67 14 / 3 3/8 1/2 -- 1050
3 / 34
4.67 14 / 4 3/8 1/2 -- 1050
3 / 34
5 14 / 4 3/8 3/4 -- 1050
3 / 34
6 14 / 4 3/8 3/4 -- 1050
3 / 34
5.3 14 / 4 3/8 1 -- 1050
4 / 34
6 14 / 4 3/8 1 -- 1050
Blower Motor: Blower Compressor Data: Type RLA LRA
4
10 x 8 800 12.1 54 7.8
4
5.8
5.8
11 x 9 1400 20 104 11.9
7.4
7.4
10 x 8 11 x 9 1000 1200 Copeland Scroll 15 72 10.5 Fixed Orifice 17.9 88 11
11 x 10 11 x 10 1600 1875 Copeland 2 Stage Scroll 23.9 116 11.5 TXV 24.6 118 14.7
Factory Refrigerant Charge (Type R- 22) (lbs) Refrigerant Metering Device Orifice ID (In) Sound Data Weights Approximate Shipping
0.067
72 300
0.070
75 329
0.082
74 382
0.086
77 392
-77 390
-80 440
UNIT PERFORMANCE DATA
MODEL NUMBER PHM324K00A PHM330K00A PHM336K00A PHM342K00A PHM348K00A PHM354K00A Cooling Data Rated Capacity S.E.E.R. E.E.R.2 BTUH 24,000 13 11 29,000 13 11 36,000 13 11 40,000 13 10.6 45,000 13 10.2 52,000 13 9.7 Rated Capacity 1 BTUH @ 47° F 23,000 28,000 33,000 39,000 44,000 51,000 Heating Data Rated Capacity 1 S/T BTUH @ 17° F HSPF Ratio 12,400 7.7 0.76 15,400 7.7 0.76 18,200 7.7 0.76 21,600 7.7 0.76 24,200 7.7 0.76 26,000 7.7 0.76 COP @ 47° F 3.2 3.6 3.3 3.3 3.4 3.3 @ 17° F 2.2 2.3 2.3 2.3 2.2 2.1 Power Input Watts 1928 2646 3086 4003 4317 5424 Evaporated Rated Airflow (SCFM) 800 1000 1200 1400 1600 1875 Ext. Static Pressure Drop 3 Wet 0.18 0.23 0.23 0.23 0.28 0.28
BLOWER PERFORMANCE DATA
Model Number Speed Tap 0.1 0.2 Air Delivery 0.3 in CFM @ 0.4 Varying 0.5 External 0.6 Static 0.7 Pressure (in. w.c.) 0.8 0.9 1.0
1
1 1078 883 783 720 681 615 489 435 378 317
PHM324 2 1170 1102 1052 1006 964 921 881 838 789 684
3 -----------
1 -----------
PHM330 2 3 1170 1266 1102 1221 1052 1184 1006 1152 964 1121 921 1089 881 1047 838 1017 789 985 684 951
1 1420 1288 1209 1170 1153 1106 1065 1011 967 910
PHM336 2 1497 1438 1387 1334 1294 1292 1247 1208 1171 1117
3 -----------
2 -----------
PHM342 3 1559 1520 1480 1438 1401 1359 1318 1268 1218 1181
4 1694 1657 1620 1583 1550 1514 1474 1437 1389 --
1 1213 1028 909 825 762 667 613 ----
PHM348 2 3 1299 1698 1226 1652 1157 1601 1094 1542 1037 1494 961 1442 915 1390 841 1324 769 1265 719 1201
4 1974 1924 1859 1813 1761 1706 1651 1602 1538 1485
1 1389 1292 1228 1159 1104 1043 988 940 873 828
PHM354 2 3 1461 2050 1417 2008 1364 1965 1296 1923 1243 1874 1180 1828 1129 1783 1083 1734 1026 1680 978 1622
4 2179 2132 2093 2049 2011 1968 1921 1877 1830 1760
Rated Capacity @ ARI standard conditions, 95° Amb, 80° DB/67° WB, 230 Volts. For applications at 208 volts deduct 1000 BTU.
Air Delivery @ listed external static pressre are taken at 230Volts with Dry coil, no filter and approved heater. Air delivery against shown external static pressures taken with 230V. to unit, dry coil and equipped with approved heater. For wet coil sadd .05″ W.C to Ext. Static Press. measurement. NOTE: For 208 Volt applications, reduce airflow by 15%.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
2
EXPANDED COOLING PERFORMANCE DATA - PHM324K00A ID Airflow (SCFM) OD Ambient o ( F) 700 800 Entering Indoor Temperature - Degrees F, Wet Bulb 900
ID Airflow (SCFM)
MBh†
57 22.1 1.00 1.7 21.3 1.00 1.9 20.5 1.01 2.1 19.6 1.00 2.3 18.6 1.00 2.5 17.5 1.00 2.8
62 23.0 0.91 1.7 22.0 0.93 1.9 20.9 0.96 2.1 19.8 0.99 2.3 18.7 1.00 2.5 17.6 0.99 2.8
63
††
67 25.2 0.70 1.7 24.5 0.71 1.9 23.4 0.72 2.1 22.1 0.74 2.3 20.9 0.76 2.6 19.4 0.79 2.8
72 26.5 0.52 1.7 26.3 0.52 1.9 26.0 0.52 2.1 24.9 0.53 2.4 23.6 0.54 2.6 22.1 0.55 2.9
57 23.3 1.00 1.8 22.5 1.00 2.0 21.6 1.00 2.2 20.7 1.00 2.4 19.6 1.00 2.6 18.5 1.00 2.9
62 23.8 0.96 1.8 22.7 0.98 2.0 21.6 0.99 2.2 20.7 0.99 2.4 19.7 0.99 2.6 18.6 1.00 2.9
63
††
67 25.5 0.73 1.8 25.1 0.74 2.0 24.0 0.76 2.2 22.7 0.78 2.4 21.4 0.80 2.6 20.0 0.83 2.9
72 26.6 0.53 1.8 26.4 0.55 2.0 26.1 0.55 2.2 25.5 0.55 2.4 24.2 0.56 2.7 22.7 0.57 2.9
57 24.3 1.00 1.8 23.5 1.00 2.0 22.6 1.00 2.2 21.6 1.00 2.5 20.5 1.00 2.7 19.4 1.00 3.0
62 24.3 0.99 1.8 23.5 0.99 2.0 22.6 1.00 2.2 21.6 1.00 2.5 20.5 0.99 2.7 19.4 1.00 3.0
63
††
67 25.8 0.77 1.9 25.5 0.78 2.0 24.5 0.80 2.3 23.2 0.82 2.5 21.9 0.85 2.7 20.4 0.88 3.0
72 27.4 0.53 1.9 27.1 0.56 2.1 26.8 0.56 2.3 26.0 0.57 2.5 24.6 0.58 2.8 23.1 0.60 3.0
23.5 0.73 1.7 22.5 0.74 1.9 21.4 0.75 2.1 20.2 0.77 2.3 19.0 0.79 2.5 17.6 0.82 2.8
24.1 0.76 1.8 23.1 0.77 2.0 22.0 0.79 2.2 20.8 0.81 2.4 19.5 0.84 2.6 18.0 0.87 2.9
24.4 0.80 1.8 23.7 0.81 2.0 22.5 0.83 2.2 21.2 0.85 2.5 19.9 0.88 2.7 18.4 0.91 3.0
75
S/T kW* MBh† S/T kW* MBh†
85
95
S/T kW* MBh†
105
S/T kW* MBh†
115
S/T kW* MBh†
125
S/T kW*
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
EXPANDED HEATING PERFORMANCE DATA - PHM324K00A Return Air CFM (Std. Air) (oF db) TC 700 kW TC 60 800 kW TC 900 kW TC 700 kW TC 70 800 kW TC 900 kW TC 700 kW TC 80 800 kW TC 900 kW -10 7.2 6.7 1.36 7.3 6.7 1.34 7.3 6.8 1.34 7.0 6.4 1.46 7.0 6.5 1.45 7.1 6.5 1.44 6.7 6.2 1.54 6.8 6.3 1.52 6.6 6.1 1.52 0 9.1 8.4 1.41 9.1 8.3 1.41 9.1 8.4 1.40 8.7 8.0 1.51 8.7 8.0 1.50 8.8 8.1 1.49 8.5 7.8 1.64 8.6 7.9 1.62 8.6 7.9 1.61 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 17 20 30 40 47 11.1 10.2 12.7 11.6 13.6 12.3 16.8 14.7 20.4 20.4 23.3 23.3 1.51 1.57 1.61 1.75 1.89 1.98 11.2 10.3 12.8 11.7 13.7 12.4 16.9 14.8 20.5 20.5 23.4 23.4 1.49 1.55 1.60 1.72 1.84 1.92 11.2 10.3 12.8 11.7 13.7 12.4 16.9 14.8 20.6 20.6 23.5 23.5 1.48 1.54 1.57 1.69 1.80 1.87 10.7 9.8 12.3 11.2 13.2 12.0 16.4 14.4 20.0 20.0 22.9 22.9 1.60 1.67 1.73 1.90 2.06 2.17 10.8 9.9 12.4 11.3 13.3 12.0 16.5 14.4 20.1 20.1 23.0 23.0 1.58 1.65 1.70 1.86 2.00 2.11 14.9 13.7 16.4 15.0 17.5 15.9 21.5 18.8 26.2 26.2 24.1 24.1 1.57 1.64 1.68 1.83 1.96 2.06 10.4 11.9 10.9 12.8 11.6 16.0 14.0 19.6 19.6 22.4 22.4 9.5 1.71 1.78 1.84 2.04 2.24 2.37 10.4 9.6 12.0 11.0 12.9 11.7 16.1 14.1 19.7 19.7 22.5 22.5 1.68 1.76 1.81 2.00 2.18 2.30 10.5 9.6 12.1 11.0 13.0 11.7 16.2 14.2 19.8 19.8 22.6 22.6 1.67 1.74 1.79 1.98 2.14 2.25 10 50 24.4 24.4 2.01 24.5 24.5 1.93 24.5 24.5 1.88 23.9 23.9 2.20 24.1 24.1 2.13 27.9 27.9 2.08 23.4 23.4 2.41 23.6 23.6 2.33 23.7 23.7 2.28 60 28.2 28.2 2.09 28.2 28.2 2.00 28.2 28.2 1.94 27.7 27.7 2.30 27.8 27.8 2.21 27.9 27.9 2.14 27.2 27.2 2.53 27.4 27.4 2.43 27.5 27.5 2.36
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
EXPANDED COOLING PERFORMANCE DATA - PHM330K00A ID Airflow (SCFM) OD Ambient o ( F) 875 1000 Entering Indoor Temperature - Degrees F, Wet Bulb 1125
ID Airflow (SCFM)
MBh†
57 27.0 0.99 2.1 25.7 0.99 2.3 24.5 0.99 2.5 23.2 0.99 2.8 21.8 0.99 3.0 20.3 0.99 3.3
62 28.2 0.91 2.1 26.4 0.94 2.3 24.8 0.97 2.5 23.3 0.99 2.8 21.9 0.99 3.0 20.4 0.99 3.3
63
††
67 30.7 0.70 2.1 30.0 0.70 2.3 28.1 0.72 2.6 26.3 0.75 2.8 24.4 0.77 3.1 22.5 0.80 3.3
72 32.0 0.50 2.1 32.4 0.52 2.3 31.7 0.52 2.6 30.0 0.53 2.8 28.0 0.54 3.1 26.0 0.55 3.4
57 28.7 0.99 2.2 27.3 0.99 2.4 25.9 0.99 2.6 24.6 0.99 2.8 23.2 0.99 3.1 21.6 0.99 3.4
62 29.1 0.96 2.2 27.4 0.99 2.4 26.0 0.99 2.6 24.7 0.99 2.8 23.3 0.99 3.1 21.7 0.99 3.4
63
††
67 31.1 0.74 2.2 30.7 0.74 2.4 29.0 0.76 2.6 27.1 0.79 2.9 25.1 0.82 3.1 23.2 0.85 3.4
72 32.9 0.49 2.2 32.7 0.54 2.4 32.3 0.54 2.6 30.9 0.55 2.9 28.9 0.56 3.2 26.7 0.58 3.5
57 29.9 0.99 2.3 28.7 0.99 2.5 27.2 0.99 2.7 25.8 0.99 2.9 24.3 0.99 3.2 22.8 0.99 3.5
62 29.9 0.99 2.3 28.8 0.99 2.5 27.3 0.99 2.7 25.8 0.99 2.9 24.4 0.99 3.2 22.8 0.99 3.5
63
††
67 31.3 0.78 2.3 31.2 0.78 2.5 29.7 0.80 2.7 27.7 0.83 3.0 25.7 0.86 3.2 23.7 0.90 3.5
72 33.1 0.49 2.3 32.9 0.56 2.5 32.6 0.56 2.7 31.6 0.57 3.0 29.5 0.59 3.3 27.3 0.61 3.6
28.9 0.72 2.1 27.1 0.74 2.3 25.4 0.76 2.5 23.7 0.78 2.8 21.9 0.81 3.0 19.8 0.85 3.3
29.5 0.75 2.2 28.0 0.77 2.4 26.2 0.79 2.6 24.5 0.82 2.8 22.6 0.85 3.1 20.4 0.90 3.4
29.9 0.79 2.3 28.8 0.81 2.5 26.9 0.83 2.7 25.0 0.86 2.9 23.1 0.90 3.2 20.9 0.95 3.5
75
S/T kW* MBh† S/T kW* MBh†
85
95
S/T kW* MBh†
105
S/T kW* MBh†
115
S/T kW* MBh†
125
S/T kW*
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
EXPANDED HEATING PERFORMANCE DATA - PHM330K00A Return Air (oF db) CFM (Std. Air) TC 875 kW TC 1000 kW TC 1125 kW TC 875 kW TC 1000 kW TC 1125 kW TC 875 kW TC 1000 kW TC 1125 kW -10 9.2 8.5 1.60 9.3 8.6 1.58 9.3 8.6 1.57 9.1 8.4 1.73 9.1 8.4 1.71 9.1 8.4 1.69 8.8 8.2 1.74 9.0 8.4 1.73 9.1 8.4 1.70 0 11.4 10.5 1.69 11.5 10.6 1.68 11.5 10.6 1.66 11.1 10.2 1.80 11.1 10.2 1.78 11.2 10.3 1.77 10.7 9.9 1.94 10.8 9.9 1.91 10.8 10.0 1.89 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 17 20 30 40 47 13.8 12.7 15.6 14.2 16.7 15.2 20.8 18.2 24.5 24.5 28.3 28.3 1.79 1.84 1.87 1.97 2.06 2.15 13.9 12.8 15.7 14.3 16.8 15.3 20.9 18.3 24.7 24.7 28.4 28.4 1.76 1.80 1.83 1.92 2.00 2.08 13.9 12.8 15.7 14.3 16.9 15.3 20.1 17.6 24.8 24.8 28.5 28.5 1.74 1.77 1.80 1.87 1.96 2.03 13.5 12.4 15.3 14.0 16.4 14.9 20.5 18.0 25.3 25.3 27.9 27.9 1.92 1.99 2.04 2.16 2.28 2.36 13.6 12.4 15.4 14.0 16.5 15.0 20.6 18.1 25.3 25.3 28.0 28.0 1.89 1.96 1.99 2.10 2.21 2.28 14.9 13.7 16.4 15.0 17.5 15.9 21.5 18.8 26.2 26.2 29.4 29.4 1.87 1.93 1.97 2.06 2.15 2.22 13.1 12.0 14.9 13.6 16.1 14.6 20.2 17.7 24.9 24.9 28.6 28.6 2.05 2.14 2.19 2.35 2.51 2.63 13.2 12.1 15.0 13.7 16.2 14.7 20.3 17.8 25.0 25.0 29.1 29.1 2.02 2.10 2.16 2.30 2.44 2.50 13.2 12.2 15.1 13.8 16.3 14.7 20.4 17.8 25.1 25.1 27.7 27.7 2.00 2.08 2.14 2.26 2.38 2.45 10 50 29.6 29.6 2.17 29.7 29.7 2.10 29.7 29.7 2.05 29.1 29.1 2.39 29.3 29.3 2.31 33.7 33.7 2.25 30.4 30.4 2.64 28.9 28.9 2.53 29.0 29.0 2.47 60 34.1 34.1 2.29 35.1 35.1 2.15 34.2 34.2 2.13 33.7 33.7 2.51 33.7 33.7 2.41 33.7 33.7 2.34 33.2 33.2 2.75 33.3 33.3 2.65 33.4 33.4 2.57
60
70
80
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
EXPANDED COOLING PERFORMANCE DATA - PHM336K00A ID Airflow (SCFM) OD Ambient o ( F) 1050 1200 Entering Indoor Temperature - Degrees F, Wet Bulb 1350
ID Airflow (SCFM)
MBh†
57 33.1 1.00 2.6 32.5 1.00 2.9 31.2 1.00 3.2 29.4 1.00 3.5 28.4 1.00 3.9 28.0 1.00 4.3
62 35.1 0.91 2.6 33.3 0.93 2.9 31.5 0.96 3.2 29.6 0.98 3.5 29.3 0.99 3.8 29.1 0.98 4.2
63
††
67 38.8 0.69 2.7 37.1 0.71 2.9 35.1 0.72 3.2 33.0 0.74 3.5 32.4 0.79 3.9 31.8 0.77 4.2
72 40.9 0.55 2.6 40.5 0.52 2.9 39.4 0.52 3.2 37.2 0.53 3.5 34.8 0.54 3.9 32.4 0.55 4.2
57 33.7 1.08 2.7 32.7 1.00 2.9 31.4 1.00 3.3 30.1 1.00 3.6 28.7 1.00 4.0 28.3 1.00 4.4
62 36.2 0.95 2.7 34.4 0.97 3.0 32.7 0.98 3.2 31.1 0.98 3.5 29.4 0.98 3.9 27.4 0.98 4.2
63
††
67 39.6 0.72 2.7 38.1 0.74 3.0 36.0 0.76 3.3 33.8 0.78 3.6 31.5 0.81 3.9 30.7 0.87 4.3
72 41.5 0.52 2.8 40.9 0.54 3.0 40.3 0.54 3.3 38.1 0.55 3.6 35.6 0.56 3.9 33.1 0.58 4.3
57 33.7 1.08 2.7 33.4 1.00 3.0 32.3 1.00 3.4 30.4 1.00 3.7 29.4 1.00 4.1 28.2 1.00 4.5
62 37.3 0.98 2.8 35.7 0.98 3.1 34.0 0.98 3.3 32.3 0.98 3.6 30.5 0.98 4.0 28.7 0.98 4.3
63
††
67 40.0 0.76 2.8 38.9 0.78 3.1 36.7 0.80 3.4 34.4 0.82 3.7 32.1 0.85 4.0 29.8 0.89 4.3
72 41.8 0.53 2.8 41.4 0.55 3.1 40.9 0.56 3.4 38.8 0.57 3.7 36.3 0.59 4.0 33.7 0.60 4.4
35.8 0.72 2.6 34.0 0.73 2.9 32.1 0.75 3.2 30.1 0.77 3.5 29.4 0.82 3.8 28.7 0.80 4.2
36.8 0.75 2.7 34.9 0.77 3.0 32.9 0.79 3.2 30.8 0.81 3.5 28.7 0.84 3.9 29.0 0.92 4.3
37.5 0.79 2.8 35.6 0.80 3.1 33.5 0.83 3.3 31.4 0.85 3.6 29.3 0.88 3.9 29.2 0.98 4.3
75
S/T kW* MBh†
85
S/T kW* MBh†
95
S/T kW* MBh†
105
S/T kW* MBh†
115
S/T kW* MBh†
125
S/T kW*
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
EXPANDED HEATING PERFORMANCE DATA - PHM336K00A Return Air CFM (Std. Air) (oF db) TC 1050 kW TC 60 1200 kW TC 1350 kW TC 1050 kW TC 70 1200 kW TC 1350 kW TC 1050 kW TC 1200 80 kW TC 1350 kW -10 10.3 9.5 1.84 10.5 9.7 1.88 11.0 10.2 1.97 9.4 8.7 1.93 9.5 8.8 1.98 10.0 9.2 2.07 8.3 7.7 2.00 8.7 8.0 2.03 9.3 8.6 2.10 0 13.3 12.2 1.95 13.4 12.3 1.99 14.0 12.8 2.08 12.6 11.5 2.09 12.7 11.7 2.12 13.2 12.1 2.21 11.5 10.5 2.22 11.8 10.9 2.24 12.3 11.3 2.34 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 47 17 20 30 40 16.3 15.0 18.5 16.9 19.7 17.9 24.2 21.2 29.3 29.3 33.5 33.5 2.05 2.12 2.17 2.35 2.56 2.72 16.4 15.1 18.6 17.0 19.8 18.0 24.3 21.3 29.6 29.6 33.8 33.8 2.08 2.14 2.18 2.35 2.54 2.68 16.9 15.5 19.0 17.4 20.2 18.4 24.8 21.7 30.1 30.1 34.4 34.4 2.16 2.21 2.25 2.42 2.59 2.70 15.7 14.4 18.0 16.4 19.2 17.4 23.6 20.6 28.6 28.6 32.7 32.7 2.22 2.30 2.36 2.57 2.80 2.98 15.9 14.6 18.2 16.6 19.4 17.6 23.7 20.8 28.8 28.8 33.0 33.0 2.24 2.32 2.38 2.56 2.78 2.93 16.4 15.0 18.7 17.0 19.8 18.0 24.2 21.2 29.3 29.3 33.5 33.5 2.32 2.39 2.44 2.62 2.82 2.96 15.0 13.8 17.4 15.8 18.6 16.9 23.0 20.2 27.8 27.8 31.8 31.8 2.37 2.48 2.55 2.80 3.04 3.25 15.2 13.9 17.6 16.0 18.8 17.1 23.2 20.3 28.1 28.1 32.1 32.1 2.40 2.50 2.57 2.79 3.02 3.20 15.7 14.4 18.1 16.5 19.4 17.6 23.7 20.7 28.6 28.6 32.7 32.7 2.48 2.57 2.64 2.85 3.07 3.23 10 50 35.1 35.1 2.76 35.4 35.4 2.72 36.2 36.2 2.72 34.3 34.3 3.03 34.6 34.6 2.97 35.2 35.2 3.00 33.4 33.4 3.30 33.8 33.8 3.25 34.4 34.4 3.27 60 41.0 41.0 2.93 41.4 41.4 2.88 40.0 40.0 2.76 40.1 40.1 3.20 40.5 40.5 3.13 41.0 41.0 3.15 39.2 39.2 3.49 39.6 39.6 3.41 40.1 40.1 3.42
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EXPANDED COOLING PERFORMANCE DATA - PHM342K00A ID Airflow (SCFM) OD Ambient (oF) 1225 1400 Entering Indoor Temperature - Degrees F, Wet Bulb 1575
ID Airflow (SCFM)
MBh†
57 37.9 1.00 3.0 36.1 1.00 3.4 35.1 1.00 3.7 32.8 1.00 4.1 31.3 1.00 4.5 28.0 1.00 5.0
62 38.8 0.99 3.3 36.7 0.99 3.4 35.9 1.00 3.7 33.9 0.99 4.0 32.2 1.00 4.3 28.6 1.00 4.9
63†† 40.2 0.72 3.3 38.5 0.73 3.4 36.7 0.75 3.7 34.3 0.77 4.0 32.3 0.79 4.3 27.4 0.90 4.9
67 40.9 0.71 3.2 40.1 0.71 3.4 39.3 0.72 3.7 36.8 0.74 4.0 34.8 0.76 4.4 31.3 0.80 4.8
72 43.7 0.51 3.6 42.7 0.52 3.6 42.2 0.53 3.7 39.3 0.54 4.0 36.0 0.53 4.3 33.0 0.59 5.1
57 37.7 1.22 3.1 37.2 1.00 3.4 36.6 1.00 3.8 34.8 1.00 4.0 31.3 1.00 4.6 28.2 1.00 4.7
62 40.3 0.99 3.3 38.6 0.99 3.5 37.2 1.00 3.8 35.2 1.00 4.0 31.7 0.99 4.7 28.8 0.99 4.7
63†† 39.6 0.76 3.3 39.0 0.77 3.5 37.4 0.79 3.8 34.9 0.81 4.0 31.3 0.85 4.4 27.6 0.90 4.7
67 43.6 0.73 3.3 40.6 0.76 3.6 40.0 0.76 3.8 37.4 0.79 4.1 33.7 0.82 4.4 30.0 0.87 4.8
72 43.9 0.53 3.3 43.6 0.55 3.5 42.4 0.55 3.8 39.7 0.56 4.1 37.6 0.58 4.5 32.9 0.59 5.1
57 37.6 1.22 3.4 37.4 1.00 3.6 37.0 1.00 3.8 33.9 1.00 4.1 32.1 1.00 4.8 29.0 1.00 4.9
62 40.1 0.95 3.4 39.8 0.99 3.6 38.1 0.99 3.8 34.1 0.99 4.1 32.7 0.99 4.8 29.7 0.99 4.9
63†† 40.2 0.78 3.5 39.6 0.81 3.6 36.5 0.84 3.8 33.4 0.86 4.1 30.5 1.01 4.8 27.9 0.97 4.8
67 42.5 0.77 3.4 42.2 0.79 3.6 40.5 0.81 3.9 36.0 0.84 4.1 32.7 1.01 4.8 30.6 0.92 4.8
72 44.7 0.55 3.4 44.6 0.57 3.6 42.8 0.58 3.9 39.9 0.57 4.2 36.6 0.61 4.9 32.8 0.55 4.9
75
S/T kW* MBh†
85
S/T kW* MBh†
95
S/T kW* MBh†
105
S/T kW* MBh†
115
S/T kW* MBh†
125
S/T kW*
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
EXPANDED HEATING PERFORMANCE DATA - PHM342K00A Return Air (oF db) CFM (Std. Air) TC 1225 kW TC 1400 kW TC 1575 kW TC 1225 kW TC 1400 kW TC 1575 kW TC 1225 kW TC 1400 kW TC 1575 kW -10 13.0 12.0 2.24 13.0 12.1 2.22 13.1 12.1 2.21 12.3 11.4 2.37 12.4 11.5 2.36 12.5 11.5 2.35 11.2 10.4 2.46 11.4 10.5 2.45 11.5 10.6 2.45 0 16.0 14.7 2.37 16.1 14.8 2.34 16.8 15.5 2.32 15.5 14.3 2.54 15.6 14.4 2.51 15.7 14.5 2.49 14.8 13.6 2.71 15.0 13.8 2.68 15.1 13.9 2.66 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 47 30 17 20 40 19.2 17.7 21.7 19.8 23.2 21.1 28.6 25.0 34.8 34.8 37.3 37.3 2.48 2.56 2.63 2.85 3.06 3.24 19.3 17.7 21.9 20.0 23.4 21.2 28.8 25.2 34.9 34.9 37.6 37.6 2.44 2.52 2.58 2.78 3.00 3.14 19.4 17.8 22.0 20.1 23.5 21.3 28.9 25.3 33.2 33.2 37.7 37.7 2.41 2.49 2.55 2.73 2.91 3.07 18.9 17.3 21.3 19.4 22.7 20.6 28.0 24.5 34.0 34.0 38.8 38.8 2.68 2.78 2.85 3.10 3.36 3.57 19.0 17.4 21.4 19.5 22.8 20.7 28.1 24.6 34.3 34.3 39.0 39.0 2.64 2.73 2.80 3.02 3.25 3.46 19.0 17.5 21.5 19.6 22.9 20.8 28.3 24.8 34.4 34.4 37.0 37.0 2.61 2.69 2.75 2.96 3.20 3.34 18.4 16.9 21.0 19.1 22.3 20.2 27.4 24.0 33.3 33.3 38.1 38.1 2.89 3.01 3.09 3.36 3.66 3.88 19.0 17.4 21.1 19.2 22.4 20.3 27.6 24.2 33.6 33.6 38.3 38.3 2.85 2.96 3.03 3.29 3.55 3.76 18.7 17.1 21.1 19.3 22.5 20.4 27.7 24.3 33.7 33.7 38.9 38.9 2.82 2.92 2.99 3.23 3.48 3.62 10 50 39.1 39.1 3.30 39.4 39.4 3.20 39.4 39.4 3.12 40.6 40.6 3.64 38.6 38.6 3.47 38.8 38.8 3.40 39.9 39.9 3.95 40.1 40.1 3.83 40.9 40.9 3.65 60 45.3 45.3 3.52 45.3 45.3 3.40 45.2 45.2 3.31 44.7 44.7 3.83 44.8 44.8 3.69 44.8 44.8 3.60 44.0 44.0 4.17 44.2 44.2 4.02 44.7 44.7 3.82
60
70
80
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EXPANDED COOLING PERFORMANCE DATA - PHM348K00A - HIGH CAPACITY ID Airflow (SCFM) OD Ambient ( F)
o
1400
1600 Entering Indoor Temperature - Degrees F, Wet Bulb
1800
ID Airflow (SCFM)
MBh†
57 42.4 0.98 3.6 41.2 0.98 3.9 39.8 0.98 4.3 38.4 0.98 4.7 36.9 0.98 5.2 -
62 43.6 0.91 3.6 42.0 0.92 3.9 40.4 0.94 4.3 38.7 0.96 4.7 37.0 0.98 5.2 -
63
††
67 47.7 0.70 3.6 45.9 0.71 4.0 44.1 0.72 4.3 42.2 0.74 4.7 40.2 0.75 5.2 -
72 52.3 0.51 3.6 50.5 0.52 4.0 48.5 0.52 4.4 46.4 0.53 4.8 44.3 0.54 5.2 -
57 44.4 0.98 3.7 43.0 0.98 4.0 41.6 0.98 4.4 40.1 0.98 4.8 38.5 0.98 5.2 -
62 44.8 0.95 3.7 43.2 0.97 4.0 41.6 0.98 4.4 40.1 0.98 4.8 38.5 0.98 5.2 -
63
††
67 48.7 0.73 3.7 46.9 0.75 4.0 45.0 0.76 4.4 43.0 0.78 4.8 41.0 0.80 5.3 -
72 53.4 0.53 3.7 51.5 0.54 4.1 49.4 0.54 4.4 47.3 0.55 4.9 45.1 0.56 5.3 -
57 46.0 0.98 3.8 44.5 0.98 4.1 43.0 0.98 4.5 41.4 0.98 4.9 39.8 0.98 5.3 -
62 46.0 0.98 3.8 44.6 0.98 4.1 43.1 0.98 4.5 41.5 0.98 4.9 39.8 0.98 5.3 -
63
††
67 49.5 0.77 3.8 47.7 0.78 4.1 45.7 0.80 4.5 43.7 0.82 4.9 41.6 0.84 5.4 -
72 54.3 0.55 3.8 52.3 0.56 4.2 50.2 0.57 4.5 48.0 0.58 4.9 45.7 0.59 5.4 -
44.3 0.72 3.6 42.6 0.73 3.9 40.9 0.75 4.3 39.1 0.76 4.7 37.3 0.78 5.2 -
45.3 0.76 3.7 43.6 0.77 4.0 41.8 0.78 4.4 40.0 0.80 4.8 38.1 0.82 5.2 -
46.1 0.79 3.8 44.4 0.80 4.1 42.5 0.82 4.5 40.6 0.84 4.9 38.7 0.86 5.3 -
75
S/T kW* MBh†
85
S/T kW* MBh†
95
S/T kW* MBh†
105
S/T kW* MBh†
115
S/T kW* MBh†
125
S/T kW*
EXPANDED COOLING PERFORMANCE DATA - PHM348K00A - LOW CAPACITY ID Airflow (SCFM) OD Ambient o ( F) 950 1100 Entering Indoor Temperature - Degrees F, Wet Bulb 1250
ID Airflow (SCFM)
MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW*
57 29.4 0.98 2.1 28.6 0.98 2.4 27.8 0.98 2.8 26.9 0.98 3.1 25.9 0.98 3.5 24.9 0.98 3.9
62 30.3 0.90 2.1 29.3 0.92 2.4 28.2 0.94 2.8 27.1 0.95 3.1 26.0 0.97 3.5 24.9 0.98 3.9
63
††
67 33.1 0.70 2.2 32.0 0.71 2.5 30.8 0.72 2.8 29.6 0.73 3.2 28.3 0.75 3.5 26.9 0.76 4.0
72 36.3 0.51 2.2 35.1 0.52 2.5 33.8 0.52 2.8 32.5 0.53 3.2 31.1 0.54 3.6 29.6 0.55 4.0
57 30.9 0.98 2.2 30.0 0.98 2.5 29.1 0.98 2.8 28.2 0.98 3.2 27.1 0.98 3.6 26.0 0.98 4.0
62 31.1 0.96 2.2 30.2 0.97 2.5 29.2 0.98 2.8 28.2 0.98 3.2 27.2 0.98 3.6 26.1 0.98 4.0
63
††
67 33.9 0.73 2.2 32.7 0.75 2.5 31.5 0.76 2.9 30.2 0.78 3.2 28.9 0.79 3.6 27.5 0.81 4.0
72 37.1 0.53 2.3 35.8 0.54 2.6 34.5 0.55 2.9 33.1 0.55 3.3 31.7 0.56 3.7 30.1 0.58 4.1
57 32.1 0.98 2.3 31.2 0.98 2.6 30.2 0.98 2.9 29.2 0.98 3.3 28.1 0.98 3.7 26.9 0.98 4.1
62 32.2 0.98 2.3 31.3 0.98 2.6 30.3 0.98 2.9 29.3 0.98 3.3 28.2 0.98 3.7 27.0 0.98 4.1
63
††
67 34.5 0.77 2.3 33.3 0.79 2.6 32.0 0.80 3.0 30.7 0.82 3.3 29.4 0.84 3.7 27.9 0.86 4.1
72 37.7 0.55 2.4 36.4 0.56 2.7 35.1 0.57 3.0 33.6 0.58 3.3 32.1 0.59 3.7 30.5 0.60 4.2
75
85
95
105
115
125
30.8 0.72 2.1 29.8 0.73 2.4 28.7 0.74 2.8 27.5 0.75 3.1 26.3 0.77 3.5 25.0 0.79 3.9
31.5 0.76 2.2 30.5 0.77 2.5 29.4 0.78 2.8 28.2 0.80 3.2 26.9 0.82 3.6 25.6 0.84 4.0
32.2 0.80 2.3 31.0 0.81 2.6 29.9 0.82 2.9 28.7 0.84 3.3 27.4 0.86 3.7 26.0 0.88 4.1
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EXPANDED HEATING PERFORMANCE DATA - PHM348K00A - HIGH CAPACITY Return Air (oF db) CFM (Std. Air) TC 1400 kW TC 1600 kW TC 1800 kW TC 1400 kW TC 1600 kW TC 1800 kW TC 1400 kW TC 1600 kW TC 1800 kW -10 13.7 12.6 2.54 14.1 13.0 2.60 14.4 13.3 2.63 12.6 11.7 2.68 13.1 12.1 2.74 13.4 12.4 2.78 11.4 10.5 2.79 11.8 10.9 2.85 12.1 11.2 2.89 0 17.3 15.9 2.70 17.8 16.3 2.74 18.1 16.6 2.76 16.4 15.1 2.89 16.9 15.6 2.94 17.2 15.8 2.96 15.4 14.2 3.07 15.8 14.6 3.12 16.2 14.9 3.15 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 17 20 30 40 47 21.4 19.7 24.6 22.4 26.3 23.8 32.4 28.3 39.1 39.1 44.5 44.5 3.50 2.85 2.95 2.99 3.18 3.36 21.9 20.1 25.1 22.8 26.7 24.2 32.8 28.7 39.7 39.7 45.0 45.0 2.87 2.97 3.02 3.18 3.34 3.46 22.2 20.4 25.4 23.1 27.0 24.5 33.1 29.0 40.0 40.0 45.3 45.3 2.89 2.98 3.03 3.18 3.31 3.43 20.5 18.8 23.7 21.6 25.4 23.0 31.5 27.6 38.2 38.2 43.4 43.4 3.08 3.20 3.25 3.46 3.68 3.84 21.0 19.3 24.2 22.1 25.9 23.5 32.0 28.0 38.7 38.7 44.0 44.0 3.11 3.22 3.27 3.46 3.66 3.79 21.3 19.6 24.5 22.4 26.2 23.8 32.3 28.3 39.0 39.0 44.4 44.4 3.12 3.23 3.28 3.46 3.63 3.75 19.6 17.9 22.7 20.7 24.3 22.0 30.4 26.6 37.2 37.2 42.4 42.4 3.30 3.45 3.51 3.73 4.01 4.19 20.1 18.4 23.2 21.1 24.8 22.5 30.9 27.1 37.7 37.7 42.9 42.9 3.34 3.48 3.53 3.74 3.99 4.15 20.4 18.7 23.5 21.4 25.2 22.9 31.4 27.5 38.1 38.1 43.3 43.3 3.36 3.49 3.54 3.74 3.96 4.11 10 50 46.7 46.7 3.58 47.2 47.2 3.53 47.7 47.7 3.44 45.6 45.6 3.92 46.2 46.2 3.87 46.5 46.5 3.82 44.5 44.5 4.28 45.1 45.1 4.23 45.5 45.5 4.18 60 54.5 54.5 3.87 55.0 55.0 3.82 52.5 52.5 3.59 53.3 53.3 4.22 53.9 53.9 4.16 54.3 54.3 4.11 52.1 52.1 4.60 52.8 52.8 4.49 53.1 53.1 4.46
60
70
80
EXPANDED HEATING PERFORMANCE DATA - PHM348K00A - LOW CAPACITY PHM348K00A1 (Low Capacity)
Return Air o ( F db) CFM (Std. Air) TC 950 kW TC 1100 kW TC 1250 kW TC 950 kW TC 1100 kW TC 1250 kW TC 950 kW TC 1100 kW TC 1250 kW -10 10.5 9.7 2.04 10.6 9.8 2.02 9.8 10.6 2.00 9.5 10.3 2.21 9.5 10.3 2.18 9.5 10.3 2.15 10.0 9.3 2.22 10.3 9.5 2.20 9.5 10.3 2.17 0 13.0 11.9 2.16 13.1 12.0 2.14 13.1 12.1 2.12 12.6 11.6 2.30 12.6 11.6 2.27 12.7 11.7 2.25 12.2 11.2 2.47 12.3 11.3 2.43 12.3 11.3 2.41 Air Temperature Entering Outdoor Coil ( F db at 70% rh) 30 40 17 20 47 15.7 14.4 17.8 16.2 19.0 17.2 23.6 20.6 27.7 27.7 31.8 31.8 2.28 2.34 2.37 2.44 2.49 2.56 15.8 14.5 17.8 16.2 19.1 17.3 23.6 20.7 27.8 27.8 32.0 32.0 2.25 2.30 2.32 2.37 2.42 2.47 15.8 14.5 17.9 16.3 19.1 17.4 22.7 19.9 27.9 27.9 32.0 32.0 2.22 2.26 2.27 2.31 2.37 2.41 15.3 14.1 17.4 15.9 18.7 16.9 23.2 20.3 28.5 28.5 31.4 31.4 2.44 2.54 2.58 2.67 2.76 2.81 15.4 14.1 17.5 16.0 18.7 17.0 23.3 20.4 28.6 28.6 31.5 31.5 2.41 2.50 2.52 2.60 2.68 2.72 14.9 13.7 16.4 15.0 17.5 15.9 21.5 18.8 26.2 26.2 33.0 33.0 2.39 2.46 2.49 2.55 2.60 2.65 14.9 13.7 17.0 15.5 18.2 16.5 22.8 20.0 28.1 28.1 32.2 32.2 2.61 2.73 2.77 2.91 3.04 3.13 15.0 13.7 17.1 15.6 18.3 16.6 22.9 20.1 28.2 28.2 32.7 32.7 2.57 2.68 2.73 2.85 2.95 2.98 15.0 13.8 17.2 15.6 18.5 16.7 23.0 20.2 28.3 28.3 31.2 31.2 2.55 2.66 2.70 2.79 2.88 2.91 10
o
60
70
80
50 33.3 33.3 2.59 33.4 33.4 2.50 33.4 33.4 2.44 32.8 32.8 2.84 32.9 32.9 2.75 38.0 38.0 2.68 34.2 34.2 3.15 32.5 32.5 3.02 32.6 32.6 2.94
60 38.4 38.4 2.72 39.4 39.4 2.56 38.5 38.5 2.54 37.9 37.9 2.99 38.0 38.0 2.87 38.0 38.0 2.79 37.3 37.3 3.28 37.5 37.5 3.15 37.5 37.5 3.06
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EXPANDED COOLING PERFORMANCE DATA - PHM354K00A - HIGH CAPACITY ID Airflow (SCFM) OD Ambient (oF) 1750 1875 Entering Indoor Temperature - Degrees F, Wet Bulb 2000
ID Airflow (SCFM)
MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW*
57 51.5 0.95 4.3 49.7 0.95 4.7 47.8 0.95 5.2 45.8 0.95 5.7 43.8 0.95 6.3 -
62 52.1 0.92 4.3 49.9 0.94 4.7 47.8 0.95 5.2 45.9 0.95 5.7 43.8 0.95 6.3 -
63†† 52.8 0.73 4.3 50.5 0.74 4.7 48.1 0.76 5.2 45.8 0.78 5.7 43.4 0.80 6.3 -
67 56.7 0.71 4.4 54.1 0.72 4.8 51.5 0.74 5.3 49.0 0.76 5.8 46.3 0.78 6.3 -
72 62.0 0.51 4.5 59.2 0.52 4.9 56.3 0.53 5.4 53.5 0.54 5.9 50.4 0.55 6.4 -
57 52.7 0.95 4.4 50.7 0.95 4.8 48.7 0.95 5.3 46.7 0.95 5.8 44.6 0.95 6.4 -
62 52.8 0.94 4.4 50.8 0.95 4.8 48.8 0.95 5.3 46.8 0.95 5.8 44.7 0.95 6.4 -
63†† 53.4 0.75 4.4 51.0 0.76 4.8 48.6 0.78 5.3 46.2 0.80 5.8 43.7 0.82 6.4 -
67 57.2 0.73 4.5 54.6 0.74 4.9 52.0 0.76 5.4 49.4 0.78 5.9 46.7 0.80 6.4 -
72 62.6 0.52 4.6 59.7 0.53 5.0 56.8 0.54 5.5 53.9 0.55 6.0 50.6 0.56 6.5 -
57 55.5 0.95 4.5 53.3 0.95 5.0 51.2 0.95 5.4 48.9 0.95 5.9 46.6 0.95 6.5 -
62 55.5 0.95 4.5 53.4 0.95 5.0 51.2 0.95 5.4 49.0 0.95 5.9 46.7 0.95 6.5 -
63†† 54.8 0.80 4.5 52.2 0.82 4.9 49.7 0.84 5.4 47.2 0.87 5.9 44.7 0.89 6.5 -
67 58.6 0.78 4.6 55.9 0.80 5.0 53.1 0.83 5.5 50.4 0.85 6.0 47.6 0.88 6.5 -
72 64.0 0.55 4.7 60.9 0.56 5.1 57.9 0.58 5.6 54.8 0.59 6.1 51.4 0.61 6.6 -
75
85
95
105
115
125
EXPANDED COOLING PERFORMANCE DATA - PHM354K00A - LOW CAPACITY ID Airflow (SCFM) OD Ambient (oF) 1150 1300 Entering Indoor Temperature - Degrees F, Wet Bulb 1500
ID Airflow (SCFM)
MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW* MBh† S/T kW*
57 34.1 0.99 2.7 33.1 0.99 3.0 32.0 0.99 3.3 30.9 0.99 3.7 29.8 0.99 4.1 28.7 0.99 4.5
62 35.1 0.92 2.6 33.8 0.94 2.9 32.4 0.96 3.2 31.1 0.98 3.6 29.8 0.99 4.0 28.7 0.99 4.5
63†† 35.8 0.72 2.6 34.4 0.74 2.9 33.0 0.75 3.2 31.6 0.76 3.6 30.2 0.78 4.0 28.9 0.79 4.5
67 38.7 0.70 2.6 37.2 0.71 2.9 35.7 0.72 3.2 34.2 0.74 3.6 32.7 0.75 4.0 31.1 0.77 4.5
72 42.6 0.51 2.6 41.0 0.51 2.9 39.4 0.52 3.2 37.7 0.53 3.6 36.2 0.53 4.0 35.1 0.54 4.5
57 35.7 0.99 2.7 34.5 0.99 3.0 33.4 0.99 3.3 32.2 0.99 3.7 31.0 0.99 4.1 29.9 0.99 4.6
62 36.1 0.97 2.7 34.7 0.98 3.0 33.4 0.99 3.3 32.2 0.99 3.7 31.1 0.99 4.1 29.9 0.99 4.6
63†† 36.6 0.76 2.7 35.2 0.77 3.0 33.7 0.78 3.3 32.3 0.80 3.7 30.8 0.82 4.1 29.4 0.84 4.5
67 39.5 0.73 2.7 38.0 0.75 3.0 36.4 0.76 3.3 34.8 0.78 3.7 33.3 0.79 4.1 31.8 0.81 4.6
72 43.4 0.53 2.7 41.7 0.53 3.0 40.1 0.54 3.3 38.1 0.55 3.7 36.7 0.56 4.1 35.3 0.56 4.6
57 37.4 0.99 2.7 36.2 0.99 3.0 34.9 0.99 3.3 33.7 0.99 3.7 32.4 0.99 4.1 31.0 0.99 4.6
62 37.5 0.99 2.8 36.2 0.99 3.1 35.0 0.99 3.4 33.7 0.99 3.7 32.4 0.99 4.2 31.4 0.99 4.6
63†† 37.5 0.80 2.8 36.0 0.82 3.1 34.5 0.83 3.4 33.0 0.85 3.7 31.5 0.87 4.2 30.0 0.90 4.6
67 40.4 0.78 2.8 38.8 0.79 3.1 37.2 0.81 3.4 35.5 0.83 3.8 33.9 0.85 4.2 32.1 0.88 4.6
72 44.2 0.55 2.8 42.5 0.56 3.1 40.7 0.57 3.4 39.1 0.58 3.8 37.1 0.59 4.2 35.1 0.60 4.7
75
85
95
105
115
125
Notes:
When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. † Total capacities are net capacities. Blower heat has been subtracted †† At TVA rating indoor condition (75 F db/ 63 F wb), All other indoor air temperatures are at 80 F db * System kW is total unit kW Standard Rating
Key:
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
EXPANDED HEATING PERFORMANCE DATA - PHM354K00A - HIGH CAPACITY Return Air (oF db) CFM (Std. Air) TC 1750 kW TC 1875 kW TC 2000 kW TC 1750 kW TC 1875 kW TC 2000 kW TC 1750 kW TC 1875 kW TC 2000 kW -10 14.9 13.8 2.91 14.8 13.7 2.82 15.3 14.1 2.92 14.0 12.9 3.11 13.9 12.8 3.02 14.3 13.3 3.11 13.0 12.1 3.30 12.9 11.9 3.22 13.4 12.4 3.31 0 19.1 17.6 3.08 19.0 17.5 2.98 19.5 18.0 3.06 18.1 16.6 3.31 18.0 16.6 3.21 18.5 17.1 3.29 17.0 15.7 3.53 16.9 15.6 3.43 17.4 16.0 3.52 Air Temperature Entering Outdoor Coil (oF db at 70% rh) 17 20 30 40 47 23.6 21.6 27.1 24.7 29.3 26.6 37.6 33.0 44.7 44.7 51.9 51.9 3.24 3.36 3.45 3.72 3.94 4.16 23.5 21.6 27.1 24.7 29.3 26.6 37.7 33.0 44.7 44.7 51.5 51.5 3.12 3.24 3.32 3.55 3.77 3.97 24.0 22.1 27.6 25.2 29.8 27.0 38.3 33.6 45.1 45.1 51.5 51.5 3.19 3.31 3.38 3.57 3.80 3.99 22.7 20.8 26.0 23.7 28.4 25.8 36.7 32.2 46.4 46.4 51.0 51.0 3.50 3.63 3.72 4.05 4.34 4.53 22.7 20.8 26.1 23.8 28.4 25.8 36.8 32.2 43.8 43.8 51.0 51.0 3.39 3.51 3.59 3.89 4.12 4.33 23.2 21.3 26.7 24.4 29.0 26.3 37.3 32.7 44.4 44.4 51.4 51.4 3.46 3.57 3.66 3.92 4.14 4.34 21.6 19.9 25.2 22.9 27.3 24.7 35.8 31.3 45.3 45.3 53.0 53.0 3.77 3.93 4.02 4.37 4.73 4.98 21.6 19.9 25.1 22.9 27.3 24.7 35.9 31.4 45.4 45.4 50.0 50.0 3.65 3.80 3.88 4.22 4.53 4.72 22.2 20.4 25.7 23.4 28.0 25.4 36.4 31.9 46.2 46.2 50.7 50.7 3.73 3.87 3.95 4.26 4.53 4.72 10 50 54.1 54.1 4.23 53.5 53.5 4.04 53.4 53.4 4.06 53.5 53.5 4.61 53.3 53.3 4.40 53.4 53.4 4.41 55.5 55.5 5.09 52.5 52.5 4.79 53.0 53.0 4.80 60 61.5 61.5 4.54 60.5 60.5 4.31 59.6 59.6 4.30 61.4 61.4 4.93 60.6 60.6 4.70 60.3 60.3 4.69 60.9 60.9 5.35 60.4 60.4 5.11 60.4 60.4 5.10
60
70
80
EXPANDED HEATING PERFORMANCE DATA - PHM354K00A - LOW CAPACITY PHM354K00A1 (Low Capacity)
Return Air o ( F db) CFM (Std. Air) TC 1150 kW TC 1300 kW TC 1500 kW TC 1150 kW TC 1300 kW TC 1500 kW TC 1150 kW TC 1300 kW TC 1500 kW -10 13.6 12.6 2.58 13.7 12.7 2.56 13.8 12.7 2.54 12.9 11.9 2.73 13.0 12.1 2.71 13.1 12.1 2.70 11.8 10.9 2.83 12.0 11.1 2.82 12.1 11.2 2.82 0 16.8 15.5 2.72 16.9 15.6 2.69 16.8 15.5 2.67 16.3 15.0 2.92 16.4 15.1 2.89 16.5 15.2 2.86 15.6 14.3 3.12 15.7 14.5 3.09 15.8 14.6 3.06 Air Temperature Entering Outdoor Coil ( F db at 70% rh) 17 20 47 30 40 20.2 18.6 22.8 20.8 24.3 22.1 29.7 26.0 35.9 35.9 38.3 38.3 2.85 2.95 2.98 3.08 3.15 3.22 20.3 18.6 23.0 21.0 24.5 22.2 29.9 26.2 36.0 36.0 38.5 38.5 2.81 2.90 2.93 3.00 3.09 3.13 20.4 18.7 23.1 21.1 24.6 22.3 30.0 26.3 34.2 34.2 38.7 38.7 2.77 2.86 2.89 2.94 2.99 3.05 19.9 18.2 22.4 20.4 23.8 21.6 29.1 25.5 35.1 35.1 39.8 39.8 3.09 3.20 3.23 3.35 3.46 3.55 19.9 18.3 22.5 20.5 23.9 21.7 29.2 25.6 35.4 35.4 40.0 40.0 3.04 3.14 3.17 3.27 3.34 3.45 20.0 18.4 22.6 20.6 24.1 21.8 29.4 25.7 35.4 35.4 38.0 38.0 3.01 3.10 3.12 3.20 3.29 3.32 19.4 17.8 22.1 20.1 23.4 21.2 28.5 25.0 34.4 34.4 39.0 39.0 3.33 3.47 3.50 3.77 3.63 3.86 19.0 17.4 22.1 20.2 23.5 21.3 28.7 25.1 34.6 34.6 39.3 39.3 3.28 3.41 3.44 3.55 3.66 3.74 19.6 18.0 22.2 20.3 23.5 21.4 28.8 25.2 34.8 34.8 39.9 39.9 3.37 3.39 3.49 3.58 3.61 3.25 10
o
60
70
80
50 40.1 40.1 3.28 40.4 40.4 3.18 40.4 40.4 3.10 41.7 41.7 3.62 39.6 39.6 3.46 39.8 39.8 3.38 40.9 40.9 3.93 41.1 41.1 3.82 42.0 42.0 3.64
60 46.5 46.5 3.51 46.5 46.5 3.39 46.4 46.4 3.30 45.8 45.8 3.81 45.9 45.9 3.68 45.9 45.9 3.58 45.1 45.1 4.15 45.3 45.3 4.00 45.9 45.9 3.80
LEGEND TC = Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat.) db = Dry Bulb kW = Total power input (Includes motor power input) rh = Relative Humidity NOTES: 1. Indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
ELECTRICAL DATA TABLE: STRIP HEATERS
HEATER MODEL EHMA05KB EHMA05KN EHMA07KB EHMA07KN EHMA10KB EHMA10KN EHMA15KB Used With 2 to 5 Ton 2 to 5 Ton 2 to 5 Ton 3 to 5 Ton Supply Voltage 240--1--60 208--1--60 240--1--60 208--1--60 240--1--60 208--1--60 240--1--60 208--1--60 EHMA20KB 3 to 5 Ton 240--1--60 208--1--60 KW Rating 5.0 3.75 7.5 5.6 10.0 7.5 15.0 11.25 20 15.0 Nominal Heating BTUH 17,065 12,798 25,598 19,113 34,130 25,598 51,195 38,567 68,260 51,195 Supply Circuit No. L3 - L4 L3 - L4 L3--L4 L3--L4 L3 - L4 L3 - L4 L3 - L4 L5 - L6 L3 - L4 L5 - L6 L3 - L4 L5 - L6 L3 - L4 L5 - L6 Heater Amps 20.8 18.0 31.3 27.1 41.7 36.2 41.7 20.8 36.2 18.0 41.7 41.7 36.2 36.2 Mininum Circuit Ampacity 26.0 22.5 39.1 33.9 52.1 45.3 52.1 26.0 45.3 22.5 52.1 52.1 45.3 45.3 Maximum Overcurrent Protective Device (Amps) 30 25 40 35 60 45 60 30 45 25 60 60 45 45
PERFORMANCE DATA: ELECTRIC HEAT ACCESSORY
*Temperature Rise °F @ CFM Heater Model EHMA05KB EHMA05KN EHMA07KB EHMA07KN EHMA10KB EHMA10KN EHMA15KB EHMA20KB Use With 2 to 5 Ton 2 to 5 Ton 2 to 5 Ton 3 to 5 Ton 3 to 5 Ton Supply Voltage 240--1--60 208--1--60 240--1--60 208--1--60 240--1--60 208--1--60 240--1--60 208--1--60 240--1--60 208--1--60 KW Rating 5.0 3.75 7.5 5.6 10.0 7.5 15.0 11.25 20.0 15.0 Total Heating BTUH 17,065 12,798 25,598 19,113 34,130 25,598 51,195 38,567 68,260 51,195 600 26.4 19.8 39.5 29.5 52.7 39.5 -59.3 --800 19.8 14.8 29.6 22.1 39.5 29.6 59.3 44.5 -59.3 1000 15.8 11.9 23.7 17.7 31.6 23.7 47.4 35.5 -47.4 1200 13.1 9.9 19.8 14.7 26.4 19.8 39.5 27.3 52.7 39.5 1400 11.2 8.4 16.9 12.6 22.6 17.0 33.9 25.4 45.1 33.9 1600 9.9 7.4 14.8 11.1 19.8 14.8 29.6 22.2 39.5 29.6 1800 8.7 6.6 13.2 9.8 17.6 13.1 26.4 19.8 35.1 26.4 2000 7.9 5.9 11.9 8.8 15.8 11.9 23.7 17.8 31.6 23.7 2200 --10.8 8.0 14.4 10.7 21.2 16.1 28.7 21.2
SERIES ACCESSORIES HEATERS
EHMA05KB EHMA05KN EHMA07KB EHMA07KN EHMA10KB EHMA10KN EHMA15KB EHMA20KB 5 KW STRIP HEATER WITH BREAKER.* 5 KW STRIP HEATER WITHOUT BREAKER. ** 7.5 KW STRIP HEATER WITH BREAKER.* 7.5 KW STRIP HEATER WITHOUT BREAKER. ** 10 KW STRIP HEATER WITH BREAKER.* 10 KW STRIP HEATER WITHOUT BREAKER. ** 15 KW STRIP HEATER WITH BREAKER. * 20 KW STRIP HEATER WITH BREAKER. *
* Order unit breaker separately for unit protection and is listed in Table for Unit. Circuit Breakers. ** Order Disconnect Switch kit separately
9
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT CIRCUIT BREAKERS - (REQUIRED WITH BREAKER STYLE HEATER FOR UNIT DISCONNECT FEATURE ORDER FROM SERVICE PARTS
Breaker Amps 20 25 30 35 40 45 50 60 60 Switch AMM001DSA Part Number Application 1082007 N/A 1082008 2 TON 1082009 21/2 TON 1082010 3 TON 1082011 3 TON 1082012 31/2 TON 1082013 31/2 -- 4 TON 1082014 4 TON 1082042 Fits All -- Disconnect Switch Only (No Over Current Protection) DISCONNECT SWITCH KIT (includes 60A switch & rain shield) BREAKER FOR UNIT ONLY. FOR “NO HEAT” or PIGTAIL STYLE HEATER APPLICATION ONLY.
MODEL NUMBER IDENTIFICATION GUIDE
Product Family PAM -- Package A/C Mobile Home PHM -- Package H/P Mobile Home SEER 3 = 13 Nominal Cooling Capacity Btuh 24 = 24,000 30 = 30,000 36 = 36,000 42 = 42,000 48 = 48,000 54 = 54,000 Example: PHM 3 24 K 00 A 1 Voltage K = 208/230--1--60 Heat Options 00 = No Heat Design Code A Eng. Rev. Code 1
DIMENSIONS
ROUND FLANGE WILL ACCOMMODATE 14” DIA. RETURN DUCT
A
COIL ACCESS PANEL
17--1/8” (436) 10--1/4” (259) CONDENSATE DRAIN CONNECTION PRESSURE 30” PORTS (763) 51” (1295) 7/8” Low Voltage Wiring (22) 11--7/8” (301) 41--1/8” (1045) 9--1/8” (232)
1--3/8” (36)
Unit PHM324 & 30 PHM336 to 54
A Dim. 32--3/8 (821) 40--3/8 (1025)
All dimensions in inches (mm)
36--1/3” (923) 1--1/4” (33) *
11--1/4” (286) 7--3/8” (186) 1--3/8” (35) *
BLOWER ACCESS PANEL
1--1/4” (33) *
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE