Docstoc

LTE-012009 - Delhi Govt Portal

Document Sample
LTE-012009 - Delhi Govt Portal Powered By Docstoc
					PT.MADAN MOHAN MALAVIYA HOSPITAL GOVT. OF NCT OF DELHI MALVIYA NAGAR, NEW DELHI-110 017 PH : 26689999, FAX: 26676412 LTE-01/2009-10 LIMITED TENDER ENQUIRY FOR PORTABLE X-RAY MACHINE, EQUIPMENTS & INSTRUMENTS, AUDIOMETRY CHAMBER & LINEN ITEMS
Sealed tenders are invited from reputed firms or their authorized distributors for the supply, installation & successful commission of Mobile X-Ray Unit -100mA, equipments , instruments, Audiometry Chamber & linen items ,as per specifications, required for Pt. Madan Mohan Malaviya Hospital, Govt. of NCT of Delhi, Malviya Nagar, and New Delhi-110017. The tender should be submitted in two bid form in separate envelopes, each envelope shall be superscribed with the bid‘s name: Prequalification & Technical Bid (Annexure III-A & III-B)  Price bid (Annexure-III-C) Both the bids/envelopes should be placed in a single envelope and the envelope should be superscribed as ―Limited Tender Enquiry-01/2009-10 for Equipments & Instruments etc.”-Group-„A‟ or “B” with the S.No. of the item /items quoted Last date of submission of tender form 16.11.09 at 1.00 PM Date of opening of tender form 16.11.09 at 2.30 PM

Group A
S. No 1 Name of the items Portable X-Ray Machine Deptt. Swine Flu Wd. Qty. Demanded 01 EMD (Rs) 20,000

Group B
2 3 4 5 Transport Ventilator Pulse Oxymeter (Vital Sign Monitor-6 Parameter) Suction Machine [Low Pressure Noiseless] Pressure up to 400mmHg Suction Machine [ High Pressure Noiseless] Pressure up to 800mmHg Anaesthesia Machine (Boyle‘s Machine) Instrument for Measuring Hb A 1 C Spot Light (Gynae Examination) Wall Mounted or Portable Instruments for Major O.T. Linen items for Major O.T. Audiometry Chamber Swine Flu Wd. Swine Flu Wd. Swine Flu Wd. Major O.T. 01 02 02 02 7,500 10,000 2,500 5,000

6 7 8 9 10 11

Anaesthesia Lab Gynae Major O.T. Major O.T. ENT

02 01 03 72 items 12 items 01

25,000 5,000 3,000 12,000 5,000 15,000

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

2

The above mentioned items may be procured Under LTE through two groups which are as follows:Group A- X-Ray Items [Item No.1] Group B- Equipment & Instruments, Audiometry Chamber and Linen Items [Item No.2 to 11]
o o o o All the participating firms should ensure that they fulfill all the eligibility criteria as prescribed in the tender. The tenders not received in time & incomplete in any respect shall be summarily rejected.

The firm shall provide catalogues/literatures. The hospital committee may ask for demonstration for the equipment. List of Institutions to which similar equipment has been supplied to be provided by the tenderer.

PREQUALIFICATION REQUIREMENT:1. Earnest Money Deposit: - The firm has to submit Rs.20, 000- (Rupees Twenty Thousand Only) as earnest money in the form of FDR (valid for a period of 6 months) in favour of Medical Superintendent, Pt. Madan Mohan Malaviya Hospital, Govt. of NCT of Delhi, Malviya Nagar, New Delhi-110017, payable at Delhi from any of the scheduled/ Nationalized Bank. (D.D / Cheque not accepted) 2. I.T. Return latest 2008-09 financial yr. (duly attested) 3. VAT Certificate (duly attested) 4. Undertaking (Annexure –I) 5. Criminal Liabilities certificate (Annexure –II) 6. Audited annual turn over document. The documents to be attached in the same sequence.  Prequalification Check list to be duly filled and signed by the tenderer (Annexure –

III/A/B/C) along with Technical Bid & Price Bid. TERM & CONDITIONS:1. Delivery of Stores:Full delivery should be made to the hospital stores within 30 days from the date of dispatch of supply order (in case of imported items within 90days). II. In case the supplies are not delivered within the stipulated time, the supplier shall have to obtain a prior extension. However the extension of date of delivery is admissible at the discretion of M.S. PACKAGING OF STORES:Tenderers should supply the stores with proper packaging and marking of transit so as to be received at the hospital stores free from any loss or damage. I. PAYMENT:Payment will be made after the receipt of complete stores, due inspection after installation & successful commission of the equipment. No advance payment will be made. PRICES:The prices quoted should be at par and confirm to the prices quoted in other Govt. Hospitals/ Institutions and no item be quoted with price more than the M.R.P. The supplier should certify that the firm has not supplied/ quoted this item to any Govt. / Pvt. Undertaking at a price lower than the rates quoted. PENALTY CLAUSE:The date of delivery of stores stipulated in the supply order shall be deemed to be the essence of the contract and delivery must be completed not later than the dates as specified in the order and shall be within 30 days ( in case of imported items within 90days) from the actual date of dispatch of the supply order. The tenderer will be bound to supply the items within stipulated period, failing whichFor Delayed Supply:- a penalty of 2% of the value of the order per week will be imposed subject to a maximum 10% value of the orders. For Non-Supply:- EMD of the firm shall be forfeited.

2.

3.

4.

5.

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10 6. WARRANTY /GUARRANTY:The firm shall offer comprehensive warranty / guaranty for a period of 24 months from the date of installation of the equipment costing up to Rs 2.0 Lac. The firm will maintain the equipment for the next 36 months and the hospital shall pay only for spares and accessories.

3

For equipment costing more than Rs 2.0 Lac. the firm shall offer comprehensive warranty / guaranty for a period of 36 months from the date of installation. After 36 months the firm will provide maintenance free of cost for another 24 months and the hospital will pay only for spares and accessories. They will maintain the equipment / machine to the satisfaction of the hospital during this 5 years period and replace spare parts free of cost or as the case may be. The tenderer will have to give post repair / replacement warranty for a minimum period of 6 months for the period beyond 36 months. The tenderer should submit bank guarantee for 5% of the cost of the equipment for 60 months indemnifying the hospital against all loses incurred by the hospital during the guaranty period. List of spare parts with prevailing market prices. 7. A.M.C.:a) For each equipment the firm shall quote for AMC charges for the next 3 years after the expiry of the comprehensive warrantee period of 2 years in case of equipment costing up to 2 lacs and for a period of 5 years for the equipments costing more than 2.0 lacs. b) The firm should ensure that the spares /consumables are made available for the next 5 years after the expiry of the comprehensive warranty period.     The Quotation should be unconditional. Litigation, if any, will be settled in Delhi Jurisdiction only. Product should be standard quality and compatible with specification asked for. M.S. has full & exclusive right to accept / reject any tender without assigning any reason.

Sd/(DR. VINOD KUMAR) MEDICAL SUPDT. Pt. Madan Mohan Malaviya Hospital

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

4

TECHNICAL SPECIFICATIONS (Item no.1) MOBILE X-RAY UNIT(100mA)             100ma high frequency diagnostic mobile X-Ray Unit The output of X-Ray generator should be 10 KW or more Frequency -40KHz of more Max mAs should be 1.0 to 22 mAs Tube voltage should be 40 - 120 Kvp Tube current should be 100mA at 100KVp at 0.8mm of less focal spot Focal spot size 0.8mm or less Heart storage capacity of X-Ray tube min. 125KHU or more Multileaf collimator with built in Timer switches X-Ray telescopic arm +/ - 270 degree rotations Column up down met to take exposure at height of 70 Cm. or less X-Ray tube rotation on its horizontal axis +/- 180 degree & X-Ray tube of min. 90 degree

OTHER FEATURES:    

Should show digital display of parameters should have on / off switch, KV, mAs, bucky selection switch & collimator lamp switch, exposure release switch (stand by) Independent KVp & mA & timer technique Counter balanced column with dual wire rope Articulated tube arm 3 wheel / 4 wheel design for easier mobility & steering.

The control should be equipped with power pack to storage energy (Capacitors may be provided)    Tube should be filled up with transformer or 1, may also contains H.V. transformer, filament transformers H.V. rectifiers Warranty for 3 years including spare parts and X-Ray tube AMC for the next 2 years after warranty should be quoted.

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

5

(Item no.2) TRANSPORT VENTILATOR 1. Should be microprocessor controlled, portable, light weight should be < 10 Kg. 2. Should operate with main electric supply as well as with battery 3. Should be able to work both with cylinders and pipeline , connectors and high-pressure tubing of appropriate length to be supplied 4. Should have turbine /piston- technology for supplying air-oxygen mixture. 5. Should have following modes of ventilation CMV, Assist.-control, SIMV, PS-PEEP 6. Audio-visual alarm for A. Low supply pressure B. High/low airway pressure C. Leakage / disconnection D. Power failure E. Apnea F. Low battery 7. Should have following settings A. TV 50—1500ml. B. PEEP/CPAP & PS C. RR up to 40bpm D. 1: E ratio 1:3 to 2:1 E. FiO2 40 – 100% 8. Rechargeable batteries should provide battery back up minimum for two hours. 9. Should have additional port for recharging from ambulance 10. Should fix on rails of transport trolley and on stand with wheels 11. Two sets of reusable silicon ventilatory circuits 12. Product should be FDA US , CE , BSI / ISI approved 13. Demonstration is must 14. Warranty for 3 years 15. AMC for 5 years after warranty. (Item no.3) Vital Sign Monitor ( 6 Parameter) Specification:Multi Channel Monitor Capable of monitoring 6 parameters:ECG, SPO2, NIBP, Temperature, ETCO2 & Respiration Accessories:Patient Cable ---------------------------1 SPO2 Probes----------- (i) Adult------2 (ii) Paed.-------1 (iii) Neonatal—1 NIBP Cuff Reusable-(i) Adult--------2 (ii) Paed. -------1 (iii) Neonatal—1 Earth Cable------------------------------1 ETCO2 Tubing-------------------------2 Power Cord-----------------------------1 Temperature Probe---------------------1 Manual-----------------------------------1

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

6

(Item no.4) Low Pressure Noiseless Suction Unit: Should have fast vacuum build up. Vacuum should have maximum 7.5-60 mm Hg. Suction capacity 8 ltr/min. Suction system should have piston/ cylinder (self lubricating) Should have mechanical overflow protection system. Should have facility for electric as well as battery operation. Should have FDA or Equivalent standard certificate. (Item no.5) High Pressure Noiseless Suction Unit: High Suction Capacity of at least 45 liters/ minute Rapid Vacuum Creation of up to at least 80kPa Operable at normal voltage of 220V Maintenance free glass cylinder /piston system Hands free with foot operated vacuum regulator Low noise and vibration levels Trouble- free cleaning Hydrophobic bacterial filter for protection of the pump Trolley with 4 antistatic castors, 2 with brakes including fitting rail Hydrophobic bacterial filter (plus 10 spare filters) 5 Litre Jar-2 with interconnecting tubing (Item no.6) Anaesthesia Machine (Boyle‟s Machine) BASIC MACHINE: Compact 3 Gases (O2, N2O & Air) Anaesthesia machine for adult & paediatric application. Should have separate provision for connecting central pipe line supply & cylinder with pressure indicating gauges for both cylinder and pipeline of each gas. Should have integrated cylinder & pipeline pressure gauge. Should have Gas specific cylinder and pipeline Inlet fittings. Should have cylinder yoke two each for Oxygen and Nitrous Oxide and One each of pipeline connection for O2, N2O & Air. Should have precisely calibrated big size double cascade flow meters for O2, N2O & Air. Should have Guarded Flow control Knobs to prevent accidental operation. Should have Emergency Oxygen flush of 35 L pm. Should have reversible Common Gas Outlet to allow for left or right handed use. Full width Modura rail for Connection of Accessories. Should have pneumatically driven Mechanical Hypoxic Guard to ensure minimum supply of 27% Oxygen concentration at any time. Should have Oxygen failure warning without battery. Should have automatic N2O shut off in case of Oxygen failure.Should have Air/N2O interlock. Should have pressure relief valve, with auto-reset feature, non-return valves & Oxygen flush. Should have single system control switch for convenience. Should have facility of delivering minimal basal flow of 100 ml of Oxygen. Should have BIS/ ISI standard certificate. List of previous installation in Delhi Govt Hospitals/ Central Govt Hospital in Delhi. Demonstration of equipment before purchase. VAPORISER: Should have two selected type Temperature and back pressure compensated vaporizers. Each machine should be supplied with Maintenance free Halothane & Isoflurane vaporizers. Should be of lightweight design with large forward facing concentration Dial. Should have Agent Capacity be more than 225ml. Should be suitable for low flow applications. ABSORBER: Should be double chamber and allow quick change over from open circuit to closed circuit.

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

7

(Item no.7) Instrument for Measuring Hb A 1 C Fully automated operation. Result obtained within 10 minutes. A keypad and printer should be present. At least 100 previous reports are stored. Result should be obtained with 1 drop of blood sample. Cost of consumables and quality control should be provided (Item no.8) Spot Light (Gynae Examination) Wall Mounted or Portable Portable Flexible Spot Light Halogen Bulb approx. 5‖ diameter with reflector Illumination 5000Lux – 6000Lux Compact base Cool to touch 35 watt halogen bulb

Details of Instruments required for Major O.T. (Item no.9) Instruments for Major O.T. S.No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Name of the items Allis Forceps Large-(200mm.) Aneurysm Needle Artery Forceps (Curved)-5‖-Small Artery Forceps (Straight)-5‖ Artery Forceps- Curved- Medium size(180mm.) Artery Forceps-Long- Straight –(200mm.) Artery Forceps-Mosquito- curved size Artery Forceps-Straight- Medium size(180mm.) Babcock Forceps-4‖ Bladder Metal Catheter Bladder Retractor Bladder Sound BP Handle No. 3 BP Handle No.4 Cidex Tray Curette Double Ended (Sharp & Blunt) Daevers Retractor (Wide) Dilator Set Doyans Retractor (Medium) Formalin Chambers Green Armytage Forceps Haeneys Double Tooth Hysterectomy Clamps Curved Haeneys Double Tooth Hysterectomy Clamps Straight Instrument Box Large Instrument Box Medium Instrument Box Small Intestinal Clamps Non- Occluding Large Intestinal Clamps Non- Occluding Medium Intestinal Clamps Occluding Medium Kochers Artery Forceps- Medium Size Kochers Clamps Medium (Haemostated)-180mm. Lagenback Refractor Large Qty Reqd. 06 02 26 08 28 06 12 20 12 02 01 02 17 17 04 02 02 02 02 04 02 08 04 03 02 02 02 02 02 06 04 02

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

8
06 02 04 04 10 03 06 08 01 01 03 01 01 04 02 06 04 02 04 02 04 40 02 02 06 each 01 01 04 02 02 12 02 02 08 08 02 04 01 02 01

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72

Lagenback Retractor Medium Lagenback Retractor Small Lane‘s Tissue Holding Forceps Large Lane‘s Tissue Holding Forceps Small Large Bowls Malleable Refractor Small Mayo‘s Scissors Long(230mm. Mayo‘s Scissors- Medium (160mm.) Miya‘s Needle Medium Miya‘s Needle Small Morri‘s Abdominal Self Retaining Retractor Myoma Screw-( Small) Myoma Screw-(Medium) Needle Holder Long & Curved (250mm.) Ovum Forceps-Medium Size Plain Non-Tooth Forceps Long Right angle Forceps Right angle Vaginal Clamps Rt. Angle Retractor 210mm X 25mm x 6mm S.S. Drums Big S.S. Drums Medium S.S. Bowl ( Small-10cm) Sim‘s Speculum Double Blade (Medium) Sim‘s Speculum Single Blade (Medium) Sim‘s Speculum Double Blade ( one medium & one large) Sims Speculum Single Blade Large Sims Speculum Single Blade Medium Sponge Holding Forceps Small Size Suction Nozzle Suture Cutting Scissor- 5‖ Suture Cutting Scissor(Straight) Tenaculum (Double Tooth) Thump Forceps Long Tissue cutting Straight Scissors-230mm. Tooth Dissecting Forceps(180mm.) Tooth Forceps Long(200mm.) Tooth Forceps Small(150mm.) Uterus Holding Clamps Volsellum Large Size Tubal Hook, Ramathibodi

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

9

(Item no.10) Linen Items [ in Cotton] S.No 1 2 3 4 5 6 7 8 9 10 11 12 Name of the items Drape Sheets Green 1x1 mtr. Drape Sheets Green 3x1 1/2 Meter Cut Sheets Medium Size Patients OT Dress Adult Patients OT Dress Pediatric Surgeon Gown Surgeon Kurta Pajama Set (Pink Colour) Surgeon Kurta Pajama Set (Blue Color) Staff Kurta Pajama Set (Green) Maxi Staff (Green Colour) Legings—(Pairs) Perineal Cut Sheets Qty Reqd. 200 200 100 100 50 200 100 100 100 25 10 50

Specification for Audiometry Chamber (Item No.11) Should have following features:  External Size  Isolation at 8 KHz  Thickness of panels  External Finish  Double Glass window  Door Closes hermetically.  Internal Light Source  With silent block& non-assisted ventilation.  Double Panel for Connection with 6 Jacks.  ISO Certified manufacturing  CE certified product (attach certificate). : 110x110 x221 cm : 44 dB : +/- 90mm : Wood

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

10

Annexure-I UNDERTAKING (To be executed on Rs. 100/- Stamp Paper) Group Name : To The Medical Superintendent, Pt. MMM Hospital Govt. of NCT of Delhi New Delhi-110017. Sir, 1. The undersigned certify that I have gone through the terms and conditions mentioned in the tender document and undertake to comply with them. I have no objection to any of the contents of the tender document and I undertake not to submit any complaint/representation against the tender document after the date and time of submission of the tender. The rates quoted by me/us are valid to and binding on me/us for acceptance of the tender. 2. The articles supplied shall be of the best quality and kind as per the requirement of the institution. The decision of the Medical Superintendent, Pt. MMM Hospital, New Delhi (Herein after called the said officer) as regard to the quality and kind of article shall be final and binding on me. 3. Bid Security deposited by me in the form of FDR in the name of the Medical Superintendent, Pt. MMM Hospital, New Delhi, as attached herewith shall remain in the custody of the Medical Superintendent till the finalization of the tender or rejection of the bid. 4. I/We agree to forfeiture of the Bid Security in the case of non execution of supply order full or in part or if delay occurs on my part at the appointed place and time. 5. In case of the purchase of the articles approved in my favour for the supply are purchased from any other source, due to delay or non-supply, the extra amount paid shall be deducted from the Bid Security submitted by me. 6. Should the M.S. deem it necessary to change any article on being found of inferior quality, it shall be replaced by me/we free of cost in time to prevent inconvenience. 7. I/We declare that no legal/financial irregularities are pending against the proprietor/partner of the tendering firm or the manufacturer. Due on :

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

11

8. I/we undertake to supply the equipment/stores within 30 days for Indian make and within 90 days for imported items. I/We undertake to supply the order within stipulated period and if I/we fail to supply during the stipulated period the necessary action can be taken by the Medical Superintendent, Pt.MMM Hospital, New Delhi. 9. I/We undertake that the item supplied shall be as per sample/catalogue/technical literature description. 10. I/We undertake that the quoted rates are not higher than that approved in any for the same item other Govt. Institutions in Delhi as well as in India. 11. Affidavit that no CBI inquiry/criminal proceeding/black Listing is pending or going against the manufacturer/bidder firm is also enclosed. I undertake that I will not submit any irrelevant documents with the tender and in doing so I will not have any objection if my tender is rejected on that ground. Affirmation I pledge and solemnly affirm that the information submitted in tender documents is true to the best of my knowledge and belief. I further pledge and solemnly affirm that nothing has been concealed by me and if any thing adverse comes to the notice of purchaser. Medical Superintendent, Pt.MMM Hospital will have full authority to take appropriate action as he/she may deem fit, without assigning any reason. Place…………. Date………….. NOTE: 1. Undertaking as per above must be submitted only on non-judicial stamp papers of Rs. 100/= (Rs.One Hundred only) along with the tender.

Signature of Bidder

(Name of Bidder)

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

12

ANNEXURE-II CRIMINAL LIABILITIES UNDERTAKING
(On Non-Judicial Stamp Paper of Rs. 100/=)

AFFIDAVIT Limited Tender for the Year 2009-10 I………….…………………………………………….S/o Sh…………………………………… Resident of (Complete Address)…………………………………………………………………… ……………………………………………………………………………………………….……… do solemnly pledge and affirm:1. That I am the proprietor of M/S…………………………………………………… situated at …………………………………………………………………………

2. That no case of any nature i.e. CBI, Criminal / Income Tax / Sales Tax / Blacklisting is pending against my above mentioned firm.

___________________________________ Signature of the tenderer/ Manufacturer Rubber Stamp of Tenderer

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

13 ANNEXURE-III(A)

PT.MADAN MOHAN MALAVIYA HOSPITAL GOVT. OF NCT OF DELHI MALVIYA NAGAR, NEW DELHI-110 017

PRE QUALIFICATION BID CHECK LIST

(CERTIFICATES / DOCUMENTS TO BE SUBMITTED WITH PRE QUALIFICATION BID) NAME OF THE GROUP: ____________________________ DUE ON _____________ GROUP NO._________. Before submitting the tender, the tenderer should check the following enclosures (to be submitted with pre qualification bid). S.NO. 1. PARTICULARS EMD For Rs.……………..(as mentioned against each items) in the form of FDR in the name of Medical Superintendent, Pt. MMM Hospital. EMD by cheque / D. D or in any other form is not acceptable Proof of filing Income tax return ( latest ) Latest and valid VAT reg. Certificate/TIN No. certificate / STCC as applicable Undertaking Criminal liability undertaking. Cost of the tender form , if applicable YES NO

2. 3. 4. 5. 6.

Please note that failure to submit any one of the above certificates / documents shall render the tender invalid. Signature of tenderer (s) Name of the tenderer (s) Address of the tenderer (s) TENDER ACCEPTED FOR FURTHER PROCESSING________________________________ TENDER REJECTED FOR FURTHER PROCESSING_________________________________

TENDER OPENING COMMITTEE

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

14 ANNEXURE-III(B)

GOVT. OF NCT OF DELHI Pt. MMM HOSPITAL, MALAVIYA NAGAR, NEW DELHI-110017 LIMITED TENDER ENQUIRY FOR THE YEAR 2009-10 TECHNICAL BID
NAME OF THE GROUP ______________________________DUE ON _______________ GROUP NO. ____________________.
ITEM CODE NAME OF THE ITEM ( AS PER THE TENDER LIST OF ITEMS ) MAKE AND MODEL QUOTED INDIAN / IMPORTED * SAMPLES YES / NO CATALOGUES YES / NO

• The tenderer should indicate as to whether they are submitting samples or catalogues or both.

Name of the Firm

Name(s) & Signature of the tenderer(s)

PT.MMM HOSPITAL, GOVT. OF NCT OF DELHI’S LTE NO.01/2009-10

15

ANNEXURE-III(C) GOVT. OF NCT OF DELHI Pt. MMM HOSPITAL, MALAVIYA NAGAR, NEW DELHI-110017 LIMITED TENDER ENQUIRY FOR THE YEAR 2009-10 PRICE BID
NAME OF THE GROUP ______________________________DUE ON _______________ GROUP NO. ____________________.
ITEM CODE NAME OF THE ITEM (AS PER THE TENDER LIST OF ITEMS) MAKE AND MODEL QUOTED PRICE (IN RS.) PER PIECE OR PER NO. * TAXES IF ANY

• VAT:1) The rates should be inclusive of everything viz. freight charges, packing charges and octroi etc. but exclusive of VAT. 2) The rates of tax (State / Central) chargeable may, however, be given separately. 3) Price quotation like ―Tax included / Inclusive of all taxes / Tax paid‖ etc. are not acceptable. In such all cases, the tenderer must indicate the quantum of (percentage of) ‗Tax Included‘ or ‗Tax paid ‗as per the case. In no case the rate quoted should be higher than M.R.P. of that item

4)

Name of the Firm

Name (s) & Signature of the tenderer (s)


				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:16
posted:12/20/2009
language:English
pages:15