gfci specification by luckboy

VIEWS: 18 PAGES: 5

More Info
									                         深 圳 市 华 科 泰 科 技 有 限 公 司
                         Shenzhen HUACA Tech CO., LTD

                               GFCI HC-GFCI-CN Specification
The GFCI is a system that Huaca analyzed all kinds of the causes which could
lead to electric shock or wiring fire comply with PRCD the newest developed with
patents of varies countries,electric shock protect security product.When it
works it can inspect the outlet of electric equipments.When leakage occurs if
the leakage current is over the setted value the power will be interruptted
automaticly to prevent the hurt to customers.


1 Features instruction

  1.1 Features
 1.1.1 3 mandrel -based ,with LED indicator and button,convenient to use。

 1.1.2 The GFCI has ground inspect function, which advance the safety factor.

 1.1.3 When the electric equipment is well connected, if there is a ground fault, the GFCI will interrupt the

power in time to avoid the third party (human body or the other conductors) being as ground connection

and hurt.
 1.1.4 The GFCI adopts the temperature compensation method which make sure the uniformity of leakage
inspect (among all the other GFCIs, the parameter character will fluctuate greatly, as the sensor changes
because of temperature, which will result in the inaccurate leakage inspect and misjudge.. hence it can not
provide the due protection.)
 1.1.5 Manual reset, to prevent unexpected start-up after power interruption.
1.2 Model definitions

HC-GFCI-XX-XX
                             Rated electric current: Arabic numerals,10 signify 10A, 15 signify 15A, 16 signify16A

                             Area code: CN signify China, UA signify USA, EU signify Europe, UK signify the United
                             Kingdom, AU signify Australia

                             Ground Fault Circuit Interrupter

                             Company code
                                 深 圳 市 华 科 泰 科 技 有 限 公 司
                                 Shenzhen HUACA Tech CO., LTD
       Model
                  HC-GFCI-UA-XX       HC-GFCI-CN-XX       HC-GFCI-EU-XX        HC-GFCI-AU-XX       HC-GFCI-UK-XX
Index:

Rated
                           120                 220                 230                         240
      (
tension V)

Rated

frequency                  60                                             50

(HZ)

Rated                                                              10

electric                                                           15

      (
current A)                                                         16

Power line        neutral、hot、ground

Action

leakage
                                                           Less than 20
current

I△n(mA)

Full       load
                  100      thousand   100      thousand   100      thousand    100      thousand   100      thousand
operating
                  times of            times of            times of             times of            times of
life
                  on-off              on-off              on-off               on-off              on-off
(frequency)

Action
                  Less than 0.08 second
time
   1.3 GFCI protection condition
   1.3.1 When the leakage current GFCI is more than 20mA, the power of electric equipment will be cut
off, and shows abnormal state
   1.3.2 When the grounding GFI is abnormal the power of electric equipment will be cut off, and shows
abnormal state

  1.4 Outline dimension
                           深 圳 市 华 科 泰 科 技 有 限 公 司
                           Shenzhen HUACA Tech CO., LTD




2 Function description and introduction for installation

    2.1 Function description
     2.1.1.Leakage protection: when leakage current is greater than setted leakage current (eg: 20mA),
     GFCI will interrupt the load power instantly.
     2.1.2Grounding inspection: when grounding fails, (if not connected, or grounding resistance is
    immense), GFCI will interrupt the load power instantly.
     2.1.3 Work status indication:
         Work status indicated by LED light
          2.1.3.1 When turn off, LED light is off, the load is disconnected.
          2.1.3.2 When normal working, LED light turns green, and load power is connected.
          2.1.3.3 Leakage current is over standard scale, LED light turns red, the load is interruptted .
          2.1.3.4 When grounding fails, LED light turns pink, the load is interruptted.

  2.2 Button introduction
    2.2.1 ON/OFF button, control the on and off status of the product, when the GFCI is connected to the

circuit, it is in closing status, the LED light is off. Press it, the product starts to output, the LED light turns

green, then press the button again, output is interruptted, the LED light turns off. The output function is

closed, the electric equipment is disconnected.

    2.2.2 GFI button, the grounding fault simulation button, when press it, the GFCI simulates the

grounding fault, the LED light turns pink, The output function is closed, the electric equipment is

disconnected .
                         深 圳 市 华 科 泰 科 技 有 限 公 司
                         Shenzhen HUACA Tech CO., LTD
     2.2.3 GFCI button, leakage simulation button, after press it , the GFCI simulates the leakage, LED

light turns red The output function is closed ,The electric equipment is disconnected.
  2.3 Installation

Plug the GFCI into the outlet to test
①Press the ON/OFF button , the LED light turns green, which indicates that the grouding is well
connected ,the GFCI can be assured to use.
②Press the GFI button, test the grounding inspect function, the LED light turns pink, which indicates the
function is regular.
③Press GFCI button , test the leakage inspect function, the LED light turns red, which indicates the
function is regular.


3 Warnings and cautions

 3.1 Application environment
   3.1.1 The environment temperature -20℃—+40℃ , relative moisture less than 90%(when temperature
   is 25℃)immergence -avoidance
   3.1.2 Avoid solarization, rain, snow, corrosive and serious dust pollution, keep it away from explosive
inflammable gas and intense magnetic field, sharp pounding and drop off avoidance.
   3.1.3Contacting water or the other liquid directly is not allowed
 3.2 Attention
3.2.1To make sure the product can work normally, Inspect the grounding and leakage firstly everytime we
use it. If it goes well, press the ON/OFF button to use it
3.2.2After put it into use, if the LED light turns pink it indicates the grounding is abnormal, should inspect
the grounding.
3.2.3After put it into use, if the LED light turns red it indicates the leakage current is greater than 20mA
should inspect the electric application entirely.
3.2.4During use, if there is a fault condition on leakage inspection. Please contact the maker, distributer to

repair, Installing should not be dismantled without authorization

3.2.5The product should be connected to the fixed plug, when inspecting the electric equipment, should be

unplugged to keep it away from power

3.2.6Special attention: The product is not able to protect the shock caused by touching the neutral

and phase

3.2.7 1 year’s warranty for free from date of shipment by normal use, the manufacturer disclaim all

responsibility for damage caused by artificial factor, improper use or arbitrary dismantle if repair is

required, cost will be charged. The cost of element will be charged after 1 year for the normal repair.
                           深 圳 市 华 科 泰 科 技 有 限 公 司
                           Shenzhen HUACA Tech CO., LTD
3.2.8 Applied with high quality socket, high temperature caused by poor contact of an inferior socket will

do harm to the product.

3.2.9 It is inadvisable to use the product as switch.

Statement: patent product, any counterfeit is considered as tort, should be investigated.

Huaca reserves the right to make any change without further notice to any product herein to improve

reliability, function or design

Add: Nanshan International Business Incubator, Nanhai Rd No.1,Shenzhen China

Tel: 0755-26581852, (0) 13714090056

Fax: 0755-26581756

Contact: Johnny Han

E-Mail:info@huaca-e.com

Website :www.huaca-e.com

								
To top