					CONSUMER INFORMATION
Visual Appearance of Garage Doors - A new garage door can be a significant                              GRP DOORS
investment that will transform the appearance of your home. This information is a guide
                                                                                                        Mould Marks - GRP doors are individually handcrafted in a mould and are then hand
to the quality you can expect.
                                                                                                        finished. Some minor marks and blemishes will inevitably remain after this process.
The Quality Check - The quality check should be carried out in natural daylight, not direct             Translucency - When viewed from the inside it may be possible to see variations in the
sunlight. Stand at a distance of three metres from the door to view the overall appearance. The         translucency of the door, particularly around and between areas of relief. On particularly cold
door is acceptable if, taking into account the facts below, none of the following are readily visible   mornings, due to heat conductivity, the pattern of the bracing structure may be noticeable from
on the face of the door.                                                                                outside. Such variations do not detract from the overall strength or build quality of the door.
                                                                                                        ALL DOORS
Marks or distortion associated with the manufacturing process
                                                                                                        Colour Match - Pairs of doors should be ordered together to obtain the best colour match,
Minor indentations, marks or scuffs on the surface
                                                                                                        bearing in mind the limitations of the materials used in the construction.
Paint or stain blemishes
                                                                                                        Size Variations - As the size of a door changes in height and/or width, the panel
                                                                                                        frequency and profile can change, therefore doors of the same style but of different sizes can be
THE FACTS
                                                                                                        significantly different in appearance.
STEEL DOORS
                                                                                                        Clearances - All one-piece doors require operating clearances ie. the gap around the door
Panel Distortion - The rolling or pressing of steel panels during manufacture will cause                panel. These are inbuilt during manufacture and should not be reduced by means of non-
distortion in the steel and, while every effort is made to keep this to a minimum, inevitably some      Henderson sourced infills or draughtproofing.
visible distortion will remain. The application of high gloss paints will make this slight distortion
                                                                                                        Deflection - When in the open position all doors will display a level of vertical deflection or
more apparent, especially under certain lighting conditions, such as car head lamps or bright
                                                                                                        ‘sag’ across the width of the panel.
sunshine. It is therefore recommended that a matt or semi gloss finish be applied to primed doors
(see ‘Caring for your Garage Door’ information on page 31).
                                                                                                        REMOTE CONTROL GARAGE DOORS
Paint Finish - Primed doors - the primer coating is applied as a base coat only and requires
additional finishing with a good quality exterior paint. Any marks or scratches on the primer coat      A remote control electric operator is a significant benefit that not only provides the convenience of
should be rubbed down and repainted as part of this finishing process.                                  being able to open and close your garage door from the comfort of your car, but can also improve
                                                                                                        the security of your door, this information is a guide to the quality and standards you can expect.
Fully finished doors - the factory application of the paint finish is an automated process and this
may result in minor blemishes or slight inconsistencies in the paint, particularly in the area of       The Quality Check - Before having a remote control operator installed you need to ensure
panel joints.                                                                                           that the installing company is able to comply with the requirements of current UK Law relating to
                                                                                                        electric operators installed to domestic garage doors.
TIMBER DOORS
                                                                                                        All power operated garage doors must be CE marked, check that the proposed installer knows this,
Timber - Timber is a natural product and there will be variations in pattern, colour,
                                                                                                        and is able to provide a legal CE mark and a Declaration of Conformity.
shading and grains. No two doors will be the same. Because wood naturally expands and
contracts according to environmental conditions, joints will open and close and some minor              Also check that the installer is aware that a switched socket outlet must be installed adjacent to
curvature may occur.                                                                                    the motor head, in such a position that the factory fitted lead and plug can be connected without
                                                                                                        any wiring alteration being required.
Finishing - It is vital that timber doors are fully finished before exposure to the elements (see
‘Caring for your Garage Door’ information on page 31).




                                                                   U.K. Customer Services Department
                                                  Telephone: 0191 377 1441 Facsimile: 0191 377 2972
                                                                                  E-mail: sales@pchenderson.com

                                                            Durham Road, Bowburn, County Durham DH6 5NG, England
                                                               Telephone: 0191 377 0701 Facsimile: 0191 377 1309
                                                                                  www.pchenderson.com

                                                                             P C Henderson (Ireland) Ltd
                                                             West Link Industrial Estate, Kylemore Road, Dublin 10, Ireland
                                                                     Telephone: 01626 0444 Fax: 01626 0455
                                                                www.pchenderson.ie E-mail: sales@pchenderson.ie
REMOTE CONTROL
SYSTEMS




          If you’ve ever had to leave your car on a cold, wet or windy day to
          open your garage door, you can probably imagine the luxury a garage
          door remote control system could bring to your life. All Henderson
          up and over and sectional doors are available with remote control so
          you can open your garage at the push of a button, from the comfort
          of your car. The door will open automatically, a light will come on in
          the garage to welcome you home and you can close the door behind
          you before leaving the safety of your car. Remote control adds
          perceived value and differentiation to your home and you will be
          pleasantly surprised by how affordable it is.




          18
There’s a Henderson remote control system for virtually every               Whichever system is right for you, the benefits of a
preference and pocket.                                                      Henderson remote control operator are clear - luxury
From the very highest standards in garage door automation to                and safety at the touch of a button.
a reliable system at an affordable price, we have a Henderson               A Henderson remote control system can be fitted to most existing doors.
                                                                            If you wish to add a remote control system to a new one-piece door, we
remote control operator to transform your lifestyle.                        recommend you choose a door with tracked or Optimizer gear.




Henderson remote control systems feature
STRONG         A unique patented drive system using a static chain                            An inbuilt courtesy light. This comes on
 &
 SILENT
               and gliding DC motor. The result is an exceptionally quiet
               operation with the minimum of moving parts, keeping
                                                                                              as the door opens, to welcome you into
                                                                                              the garage and to help you park, before
               Henderson systems virtually maintenance free                                   it switches itself off automatically

               An in-built sensor which detects any obstruction and stops                     Two mini handtransmitters supplied as
               the door movement, reversing for two seconds, if on the                        standard. A switch is also provided for
               closing cycle, to allow any trapped object to free itself                      mounting on a wall inside the garage

               Self-inhibiting gearing in the motor, which means that the                     A rolling code security system with 74
               drive mechanism cannot be forced into reverse. When the                        trillion different combinations, which
               door is closed, the Henderson electric operator protects                       makes copying of the remote control
               against unauthorised entry                                                     signal virtually impossible

                                                                                              Automatic memorising of the force
                                                                                              needed to open and close the door and the
                                                                                              distance of travel. This allows every Henderson
                                                                                              operator to achieve a softer start and end to each
                                                                                              cycle, ensuring the final closing action of the door
                                                                                              is as quiet and as safe as possible


                                               More information on Henderson remote control systems is available in two leaflets
                                               ‘Remote Control Systems for Garage Doors’ and ‘Aperto Remote Control’. Ask your
                                                supplier for a copy, contact Henderson free on 0800 252 883 or download the
                                                 brochures from our website at www.pchenderson.com.


The transmitter
shown is supplied with
Marathon, Sprint and
Duo systems. The
                                                        Once your home has a Henderson
transmitter supplied with the
Aperto system and with
automated g30 doors features
different designs. The remote
                                                         remote control system fitted, you’ll
control system supplied with the g30
package may have slightly different
features to those shown above.
                                                           never want to be without one again.
                                                                      19
ROLLER
G A R AG E D O O R S
                       Henderson roller doors are the ideal solution for homes
                       where space on the driveway is at a premium or where the
                       entrance into the garage is narrow. The door curtain rolls up
                       around a drum, with no outswing or arc of travel as it opens
                       and closes, allowing you to park right up to the door.
                       There’s no need for a timber frame and, as the door is
                       installed behind the brickwork opening, it’s ideal for arched
                       garages.

                       All Henderson roller doors have a tough and durable fully
                       finished Plastisol exterior coat with a choice of ten attractive
                       colours (see page 23 for colour details). Once installed, your
                       door will not need to be painted - the occasional wash will
                       keep it looking like new.

                       For an added touch of luxury, Henderson roller doors can
                       be supplied with remote control electric operation to allow
                       you to open your door from the comfort and safety of your
                       car. All you need to do is tell us which side of the door
                       (viewed from inside the garage) is nearest to a power supply
                       and we will fit the motor as we build the door.

                       Remote controlled roller doors are supplied with two mini-
                       hand transmitters as
                       standard. With a ‘rolling
                       code’ transmission, the
                       security code moves
                       onto a new code within a
                       choice of two billion
                       options, making the code
                       virtually impossible to
                       copy.

                       An in-built obstruction
                       sensor and safety reverse
                       ensures that trapped
                       objects are sensed as the
                       door closes and it reverses to allow the
                       object to free itself. With an in-built automatic
                       light to welcome you home and even an auto-
                       close facility for the forgetful, an automatic roller
                       door could add a touch of luxury to your life.




                 20
                                                                                 DOOR CONSTRUCTION
Henderson roller doors are manufactured to a high                       Henderson roller doors feature a crisp square ribbed design.
specification to provide you with an attractive door that               Polyglide running strips, nylon drum wheels and springs
is smooth to open and close, space saving and                           inside the drum ensure smooth opening and closing and a
guaranteed to last.                                                     door which is light to lift by hand.

Henderson Roller garage doors ...                                          Cutaway view from inside the garage

Fit behind the brickwork opening, ideal for arched garages or
where the opening is awkward or not square                                                                                              Internal
                                                                                                                                          spring
                                                                                                                                      mechanism
Require no timber frame, keeping installation simple and giving
you the maximum possible drive through opening from
                                                                                                                                 Hardwearing
brickwork to brickwork                                                                                                      nylon drum wheel

Roll up around a neat drum located above the opening. With
no outswing or arc of travel, you can park right up to the door
(ideal if you have limited space on your driveway)                         ‘Polyglide’ allows
                                                                           effortless operation
                                                                                                                                  Roller door
Have an in-built ‘Polyglide’ running strips for smooth door                with minimal friction
                                                                                                                                      curtain,
operation                                                                                                                        exterior face
                                                                                                                                pre-coated in
                                                                                                                              HP 200 Plastisol
Have full height steel guides, a reinforced aluminium bottom
rail and full width dual locking bars for security
                                                                                                                                     Crisp square
Are supplied pre-finished in durable HP200 Plastisol with a                                                                         profile design

choice of ten attractive colours. Your door will not require re-
painting and the exterior finish is guaranteed by Henderson for            Full height
                                                                                                                                      Reinforced
                                                                           steel guides
10 years                                                                                                                              aluminium,
                                                                                                                                      bottom rail
Are fitted with a full width bottom PVC weatherseal to keep
rain and leaves out of your garage                                                                           Full width
                                                                                                             PVC weatherseal
Are available with the added luxury of remote control - supplied
factory pre-fitted to your door




                                                                        * HP200 Plastisol is a registered trademark of Corus Plc.




                                                                        FOR      COLOURS AND
                                                                                    FINISHES
                                                                                          SEE PAGE 23




                                                                   21
                                                                                                                           PREMIERE
                                                                                                                         STEEL DOORS
                                                                                                                   Premiere steel doors are supplied in a Matt
                                                                                                                 White primer, enabling you to paint the door to
                                                                                                                match the existing colour scheme of your home.
                                                                                                                   Also available is the option of factory applied
                                                                                                                deep textured fully finished White and a choice of




             COLOURS                                                                                             five factory finished colours. All Premiere Steel
                                                                                                                         doors are finished inside and out.




             & FINISHES
                                                                                                                                  Primed White



           g30 SECTIONAL                                                 TIMBER
                DOORS                                                    DOORS

g30 sectional doors are available in a choice of fully   All Timber doors are available unstained (with the
    finished White or Brown as standard. Both            exception of the Monarch which is supplied with a                     Fully finished White
   colours feature the unique g30 emboss detail.         Mahogany woodstain as standard). However, if the
                                                           thought of hand staining a timber door fills you
  All doors are also available in a Primed finish,         with dread, why not order a pre-finished door
   enabling you to paint the door to match the                from the Henderson range? The Brandon,
 existing colour scheme of your home. Or if you                Balmoral, Warwick, Lincoln, Gloucester,
   have a particular RAL number in mind, let us          Buckingham and Berkeley styles are all available in
  know and we’ll paint your door to the chosen           a factory applied woodstain finish, with a choice of
specification. All g30 doors are fully finished White              Mahogany or Dark Oak colour.
                    on the inside.                                                                                          Fully finished Oxford Blue




                                                                                                                           Fully finished Balmoral Green




                                                                             Unstained                                      Fully finished Ebony Black




                 Fully finished White                                        Mahogany                                       Fully finished Monarch Red


               Fully finished White




                Fully finished Brown                                         Dark Oak                                      Fully finished Conker Brown




                                                                              22
           GRP DOORS                                                   CASTLE STEEL & ROLLER DOORS

    All timber effect doors (Abbey, Ashton,           Roller doors are available in all colours except primed White. Castle steel doors are available in
Caversham and Cumberland) are available in a           primed White (for painting the door to match an existing colour scheme) or in Plastisol finish
   choice of seven hand-stained timber effect              with a choice of up to nine colours. The Mahogany and Golden Oak colours feature a
 finishes. The Consort, Solstice and President        woodgrain finish. All other colours feature an attractive leathergrain finish. The exterior face of
 designs are supplied in smooth Gloss White.                               Plastisol doors is guaranteed for a period of ten years.




                    Matt White                                       Primed White                                           Fully finished White
                All timber effect doors                          All Castle door styles.                                Roller and all Castle door styles.
                                                              Not available for Roller doors.




                     Mahogany                                  Fully finished Mahogany                                  Fully finished Burgundy Red
                All timber effect doors                      Roller and all Castle door styles.                     Roller & Durham & Warwick Castle only.




                     Light Oak                                                                                        Fully finished Van Dyke Brown
                                                          Fully finished British Racing Green                       Roller & Durham & Warwick Castle only.
                All timber effect doors
                                                         Roller & Durham & Warwick Castle only.




                      Mid Oak
                All timber effect doors                        Fully finished Mushroom                                   Fully finished Terracotta
                                                         Roller & Durham & Warwick Castle only.                     Roller & Durham & Warwick Castle only.




                     Dark Oak                                  Fully finished Night Blue
                All timber effect doors                                                                                      Fully finished Black
                                                         Roller & Durham & Warwick Castle only.                     Roller & Durham & Warwick Castle only.




                     Burnt Oak                                Fully finished Golden Oak
                All timber effect doors                             Roller doors only.
                                                              Not available for Castle doors.




                    Gloss White
           Consort, Solstice, President only          All finish and colour options are shown for guidance only. Due to the
                                                 limitations of the printing process colour likeness cannot be guaranteed. Your
                                                    Henderson supplier will be able to show you finish and colour samples.


                                                 Timber is a natural product and there will be variations in pattern, colour, shading and
                                                 grains. No two doors will be the same. Factory applied timber stain finishes are hand
                                                                applied and will raise the timber grain slightly when dry.
                        Beige
                All timber effect doors




                                                                        23
             GARAGE DOOR

             SECURITY
The security of property and possessions is important to every homeowner. At Henderson we understand the importance of
providing garage doors with the highest level of protection. We insist on it being at the forefront of product design and fitted as
standard with every door.




HENDERSON ROLLER DOOR                                                       HENDERSON g30 SECTIONAL DOOR
SECURITY                                                                    SECURITY
All Henderson roller doors are supplied with factory fitted dual            All Henderson g30 sectional doors are supplied with a spring
locking bars which locate into full height steel running guides             rod mechanism which locates into the full height
fixed to the garage wall on both sides of the door. A full width            steel track fixed to the garage wall. A separate handle and
reinforced aluminium bottom rail provides additional strength               eurocylinder lock mechanism give additional protection
to the door curtain.                                                        against attack.




                                       Roller door dual locking bars




     Full width reinforced
     aluminium bottom rail

     Full height steel
     running guide




                                                                       24
HENDERSON ONE-PIECE UP AND                                                               REMOTE CONTROL ELECTRIC
OVER DOORS                                                                               OPERATION
Henderson one-piece garage doors are supplied with a separate                            A Henderson remote control garage door system can be added
handle and eurocylinder lock (preventing attempted access by                             to your door, providing additional security as well as a
attacking a joint handle/lock mechanism) and factory fitted                              touch of luxury. The motors used by Henderson
multi-point security as standard.                                                        Sprint, Marathon, Duo and Aperto systems feature
                                                                                         self-inhibiting gearing. As it cannot be forced into
DOORS WITH CANOPY OPERATING                                                              reverse, a Henderson remote control system gives
GEAR                                                                                     unbeatable resistance to any attempt to force the
All doors with canopy operating gear are factory fitted with                             door open. There is even the unique facility to link
two point sprung lever action locking as standard.                                       a Henderson system to your house alarm.




                                                                                                      Henderson two point sprung lever action
                                                                                                      locking is factory fitted to all canopy
                                                                                                      doors, complete with anti-tamper plates.




DOORS WITH TRACKED AND
OPTIMIZER OPERATING GEAR
All doors with tracked and Optimizer operating gear are factory
fitted with four point sprung lever action locking as standard.




                                                                                                      Henderson four point sprung lever action
                                                                                                      locking is factory fitted to all tracked and
                                                                                                      Optimizer doors.




                                                                                                      A robust lock body featuring a separate
On doors with Optimizer operating gear, the top two locking points secure against                     handle and eurocylinder lock barrel, is
the frame head. On doors with tracked operating gear, the top two locking points                      factory fitted to all one-piece doors.
secure against the frame legs, as shown.


                                                                                    25
                  THE RIGHT SIZE
                  F O R YO U R H O U S E
Garage doors are not always straight forward to install and Henderson recommend that you use a recognised tradesperson to measure
for and install your new door. To help you understand the size of a garage door which is right for your property, use the guidelines below.

                                                     ONE-PIECE (UP AND OVER) DOORS
                                                     Up and over doors can be fitted either to a good quality timber frame or with a
                                                     Henderson metal frame and can be fitted either within the brickwork opening or behind it.
                                                     All door sizes are based on the inside frame dimensions. For example, if a door is said to
                                                     be 7'0" (2134mm) wide, this measurement is actually the distance between the inside
                                                     edges of the frame legs. The door itself is narrower and shorter than the inside frame sizes
                                                     so that the door has the necessary clearance to pass through the opening. In all instances,
                                                     quote the inner frame size, not the measurements of any existing door.

                                                     To fit an unframed Henderson Door to an existing timber frame:
                                                     Ensure the existing frame is sound, square and secure and the timber is the recommended
                                                     size of 76mm x 76mm (3"x3"). The minimum headroom and sideroom required is 70mm
                                                     and 57mm respectively for doors with canopy gear, 38mm and 70mm respectively for
Always measure from more than                        doors with tracked gear and 38mm and 60mm respectively for doors with Optimizer gear.
one point as brickwork or the                        To find the right size, measure timber to timber (A) and floor to timber (B)
timber frame may not be consistent.
Always ensure there is sufficient                    To fit a framed Henderson Door within the brickwork opening:
internal clearance in the garage for                 If the door is to be fitted with a Henderson metal frame, measure brickwork to brickwork
the door to be installed and operate                 (C) and floor to brickwork (D). For doors with a steel frame (Premiere steel, GRP, timber
fully.                                               doors and Castle steel doors over 8' wide), subtract 160mm from the opening width and
                                                     80mm from the opening height to allow for the frame. For doors with a narrow fit
Notes:                                               aluminium frame (Castle steel doors up to 8' wide and special request 7066 and 7070
1. The brickwork opening sizes for                   canopy doors in all ranges) subtract 130mm from the width and 80mm from the height.
   fitting a Henderson door in a metal
   frame ‘within the brickwork opening’
   include a 5mm gap between each                    To fit a framed Henderson door behind the brickwork opening:
   frame leg and the brickwork and a                 Measure brickwork to brickwork (C) and inside floor to brickwork (D). Subtract 20mm
   10mm gap between the frame head                   from the opening width to allow for variations in the brickwork.
   and the brickwork.
2. The brickwork opening sizes for
   fitting a Henderson door in a metal
   frame ‘behind the brickwork opening’
   are based on the frame overlapping                 BRICKWORK OPENING SIZES FOR COMMON SIZED DOORS WITH A HENDERSON METAL FRAME
   into the opening by 10mm on both
   sides to allow for brickwork. The                  All sizes shown are for the Henderson steel frame. For the Henderson narrow fit aluminium frame, subtract 30mm
   minimum amount of overlap is                       from C and 30mm from E.
   2.5mm each side and the maximum                      Order           Inner frame size            Outer frame size    Brickwork opening size if   Brickwork opening size if
   is 62.5mm each side (steel frame)
   and 40mm each side (narrow fit                      Number            A              B           C             D     fitted within the opening   fitted behind the opening
   aluminium frame).                                                   Width         Height        Width       Height   E Width         Height       Width          Height

Henderson Frame Dimensions                              6666        1981 (6'6")    1981 (6'6")     2131         2051      2141           2061         2001           1981
Steel Frame: Single sized doors:                        6670        1981 (6'6")    2134 (7'0")     2131         2204      2141           2214         2001           2134
75mm wide on the legs, 70mm high on                     7066        2134 (7'0")    1981 (6'6")     2284         2051      2294           2061         2154           1981
the head and 53mm deep all round.                       7070        2134 (7'0")    2134 (7'0")     2284         2204      2294           2214         2154           2134
Double sized doors: Depth 75mm on
the legs, 70mm on the head. Available for               7666        2286 (7'6")    1981 (6'6")     2436         2051      2446           2061         2306           1981
all Premiere steel, GRP, timber doors                   7670        2286 (7'6")    2134 (7'0")     2436         2204      2446           2214         2306           2134
and Castle steel doors (over 8’wide).                   8066        2436 (8'0")    1981 (6'6")     2588         2051      2598           2061         2458           1981
Narrow fit Aluminium Frame:                             8070        2438 (8'0")    2134 (7'0")     2588         2204      2598           2214         2458           2134
60mm wide on the legs, 70mm high on                     9066        2743 (9'0")    1981 (6'6")     2893         2051      2903           2061         2763           1981
the head and 48mm deep all round.                       9070        2743 (9'0")    2134 (7'0")     2893         2204      2903           2214         2763           2134
Available for Castle steel doors up to                  1466        4267 (14'0")   1981 (6'6")     4417         2051      4427           2061         4287           1981
8' wide and for special request 7066 and
7070 size canopy Premiere steel, GRP                 To work out          Steel Frame            = A+150mm = B+70mm = C+10mm = D+10mm = A+20mm                       =B
                                                     a size not
and timber doors.                                    shown use
                                                                       Aluminium Frame           = A+120mm = B+70mm = C+10mm =D+10mm = A+20mm                        =B
All sizes are subject to manufacturing tolerances.
                                                     this formula


                                                                                      26
                                     g30 SECTIONAL GARAGE DOORS
                                     The Henderson g30 sectional door can be fitted either to a good quality timber frame or
                                     direct to sound brickwork and can be fitted either within or behind the brickwork
                                     opening. If fitted within the brickwork opening, the door must be fitted to a timber frame.
                 HEIGHT B


                                     To fit a g30 door behind the brickwork opening
                                     Measure the brickwork opening width (A) and height (B). Ensure you have adequate
       WIDTH A
                                     sideroom, headroom and clear space (depth) into the garage. The space required is
                                     determined by the operating gear chosen. See the table below for details of the operating
                                     gear options.



                                     To fit a g30 door to a timber frame within the brickwork opening
                                     Measure the brickwork opening width (A) and height (B). Subtract the required side and
                                     headroom (as shown below) and install a timber frame to suit. For example, a door with
                                     standard tension gear will will require a timber frame of minimum nominal 3”x3” (70mm x
                                     70mm) for the frame legs and 6”x 3” (150mm x 70mm) for the frame head.



                                         SIDEROOM/HEADROOM REQUIRED AND DEPTH OF TRAVEL INTO GARAGE
                                                                          Sideroom     Headroom (mm)                  Depth into garage (mm)
                                                 Operating gear
                                                                            (mm)      Manual   Automatic        Manual*              Automatic

                                                                                                           opening height (B)   B ≤ 2250 = 3350
                                     Tension                                70         150       150
                                                                                                              + 700mm           B ≥ 2375 = 4450

                                                                                                           opening height (B)   B ≤ 2250 = 3350
                                     Tension (low headroom)                120         100       120
                                                                                                              + 750mm           B ≥ 2375 = 4450

                                                                                                           opening height (B)   B ≤ 2250 = 3350
                                     Torsion front                          70         200       200
                                                                                                              + 700mm           B ≥ 2375 = 4450

                                                                                                           opening height (B)   B ≤ 2250 = 3350
                                     Torsion rear (low headroom)            70         100       120
                                                                                                              + 800mm           B ≥ 2375 = 4450

                                                                                 * when opening height is 1900mm, add on an extra 100mm




                                     ROLLER GARAGE DOORS
                                     Henderson roller garage doors are designed to fit behind the brickwork opening and to
                                     overlap the brickwork slightly in width. To order the size of your Henderson roller door,
                                     follow these 3 steps:

                                     1. The headroom required          2. The door should overlap              3. The minimum sideroom
                                     from the top of the               the opening on each side                required between the
                                     opening to any obstruction        by: Series A:25mm, Series               opening and the side wall
                                     or the underside of the           AA:50mm. Therefore to                   of the garage at each side is
                                     ceiling/rafters is 420mm.         specify the opening width,              100mm. For remote
                                     A headroom as low as              state the opening +50mm                 controlled doors, add an
                                     300mm can be used, but            (Series A) or opening                   extra 25mm on each side.
Series A = Doors to 3710mm wide      the underside of the rolled       +100mm (Series AA).
Series AA = Doors over 3760mm wide   up door will show when            State the height from inside
                                     the door is in the open           floor to underside of the
                                     position. Headroom                brickwork.
                                     clearance must extend for
                                     a minimum of 450mm back
                                     from the opening.


                                                                  27
                    DESIGN DETAILS
                    F O R PA N E L L E D D O O R S
       This information is given for guidance purposes only. P C Henderson reserve the right to make changes to door specifications without prior notice.

       PREMIERE STEEL DOORS
       Premiere steel doors have three rows of embosses. The number of columns increases with the width of the door.
          Columns
                                                                       Inner frame size                                                Total number of
                                                                                                    Number of columns
                                                                         (width) mm                                                  embosses (columns x 3)
                                            Corinthian/Minster           1829 - 2079                        3                                  9
Rows                                                                     2080 - 2586                        4                                 12
                                                                         2587 - 3093                        5                                 15
                                                                         3094 - 3600                        6                                 18
                                                                         3601 - 4107                        7                                 21
       Corinthian       Doric                                            4108 - 4614                        8                                 24
                                                                         4615 - 4877                        9                                 27
                                            Doric/Victoria               1829 - 2588                        3                                  9
                                                                         2589 - 3599                        5                                 15
                                                                         3600 - 4877                        7                                 21
                                            Emboss sizing: Premiere steel, Doric/Corinthian               Emboss sizing: Premiere steel, Victoria/Minster
       Minster          Victoria                             Width (mm)              Height (mm)                           Width (mm)               Height (mm)
                                            Top                 406                       434*            Top                 406                        432
                                            Middle              406                       522             Middle              406                        434**
                                            Bottom              406                       434*            Bottom               406                       434**
                                                                                                           *Doors over 2286mm high = 522 **Doors over 2050mm high = 522

       CASTLE STEEL DOORS
       York and Rochester Castle steel doors have three rows of embosses. Arundel and Stirling have two rows of embosses.
       The number of columns increases with the width of the door.
                                                             Inner frame size          Number of          Total number of embosses                    Number of
                                                               (width) mm               columns       York/Rochester      Arundel/Stirling            infill strips
                                            Castle             1930 - 2134                3                   9                      6                     –
                                            steel              2135 - 2286                3                   9                      6                     2
                                            doors              2287 - 2438                3                  9                      6                      2
       York             Rochester
                                                               2625 - 2774                4                  12                      8                     1
                                                               2775 - 3063                4                  12                      8                     3
                                                               3180 - 3351                5                  15                     10                     –
                                                               3352 - 3691                5                  15                     10                     2
                                                               3885 - 4267                6                  18                     12                     1
       Arundel          Stirling            Emboss sizing: Castle steel, York/Rochester                   Emboss sizing: Castle steel, Arundel/Stirling
                                                            Width (mm)                Height (mm)                         Width (mm)                  Height (mm)
                                            Top                  500                      310             Top                  500                       1120
                                            Middle               500                      690             Bottom               500                        500
                                            Bottom               500                      500

       GRP DOORS
       GRP doors are hand made using moulds to create the door panel styling. All door sizes are shown in imperial.
                          Pattern width          Door Width                  Door Height             Border (per side)           Pattern              Number of
                                               From          To           From          To            Min           Max         Width (mm)             columns
                                                7'0"        9’6"           6'6"        7'6"          2.56"        17.5"            1985                     6
                                                9'7"      11'10"           6'6"        7'6"          3.93"       17.10"            2719                     8
                                               11'11"     13'11"           6'6"        7'6"           3.9"        15.9"            3415                    10
                                               14'0"       15'0"           6'6"        7'6"          2.69"         8.7"            4111                    12
                        Abbey
                                                 Door Width                  Door Height             Border (per side)           Pattern            Columns x rows
                                               From          To           From          To            Min          Max          Width (mm)          (width x height)
                                                7'0"         8'0"          6'6"        7'6"          3.64"       9.62"             1930                  6x4
                                               14'0"        14'0"          6'6"        7'0"          4.88"       4.88"             4000                 12 x 4
                                               14'0"        15'0"          6'6"        7'6"          3.93"      10.80"             3990                 12 x 4
                        Ashton
                                                Door Width                   Door Height              Border (per side)          Pattern             Columns x rows
                                               From         To            From          To            Min          Max          Width (mm)           (width x height)
                                                7'0"        8'6"           6'6"        7'6"          4.23"       13.22"            1900                   4x3
                                                8'7"       10'0"           6'6"        7'6"          3.68"      12.19"             2410                   5x3
                                               10'1"      11'11"           6'6"        7'6"          2.84"      14.33"             2910                   6x3
                        Consort                12'0"       13'6"           6'6"        7'6"          5.07"      14.07"             3400                   7x3
                                               13'7"       15'0"           6'6"        7'6"          4.05"      12.60"             3915                   8x3

                                                                                  28
                                  Columns


                                                                        Door Width                            Door Height       Border (per side)                     Pattern                         Columns x rows
                     Rows                                             From         To                       From        To       Min         Max                     Width (mm)                       (width x height)
                                                                       7'0"        8'6"                      6'6"       7'6"    4.23"      13.22"                       1900                               4x3
                                                                       8'7"       10'0"                      6'6"       7'6"    3.68"      12.19"                       2410                               5x3
                                                                      10'1"      11'11"                      6'6"       7'6"    2.84"      14.33"                       2910                               6x3
                               Caversham                              12'0"       13'6"                      6'6"       7'6"    5.07"      14.07"                       3400                               7x3
                                                                      13'7"       15'0"                      6'6"       7'6"    4.05"      12.60"                       3915                               8x3

                                                                        Door Width                            Door Height       Border (per side)                     Pattern                           Number of
                                                                      From         To                       From        To       Min         Max                     Width (mm)                         panels wide
                                                                       7'0"       8'5"                       6'6"       7'6"    3.64"     12.13"                       1930                                 24
                                                                       8'6"      10'0"                       6'6"       7'6"    3.18"     12.18"                       2410                                 30
                                                                      10'1"      11'6"                       6'6"       7'6"    3.23"     11.73"                       2890                                 36
                               Cumberland                             11'7"      12'9"                       6'6"       7'6"    3.14"     10.14"                       3352                              20 + 20
                                                                      12'10"     13'10"                      6'6"       7'6"    4.34"     10.34"                       3672                              22 + 22
                                                                      13'11"     15'0"                       6'6"       7'6"    4.54"     11.04"                       3992                              24 + 24

                                                                        Door Width                            Door Height       Border (per side)                     Pattern                           Number of
                                                                      From         To                       From        To       Min         Max                     Width (mm)                         panels wide
                                                                       7'0"       8'6"                       6'6"       7'6"    3.64"      12.60"                            1930                                4
                                                                      13'10"     15'0"                       6'6"       7'6"    4.35"      11.40"                            3960                                8

                               President


                                                                        Door Width                            Door Height       Border (per side)                     Pattern                      Columns x rows
                                                                      From         To                       From        To       Min         Max                     Width (mm)                    (width x height)
                                                                       7'0"       8'6"                       6'6"       7'6"    3.93"       13.38"                     1900                       4 x 2 (1 sunrise)
                                                                      13'6"      15'0"                       6'6"       7'6"    3.93"       13.38"                     3900                       8 x 2 (2 sunrises)

                               Solstice



g30 SECTIONAL DOORS
                        GEORGIAN DOOR - PANEL DETAILS                                                                                           RIBBED DOOR - PANEL DETAILS
     (H) PANEL        (DW) DAYLIGHT   NUMBER OF            (J) END      (S) LAND     (X) EMBOSS (G) EMBOSS (C) BOTTOM            (H) PANEL       NUMBER         (X) RIBBED        (Y) SPACE            (Z) RIB       (C) BOTTOM
      HEIGHT            WIDTH mm       EMBOSSES            SPACING      SPACING        HEIGHT     WIDTH      SPACING              HEIGHT         OF RIBS           AREA         BETWEEN RIBS           WIDTH           SPACING

                      1800-2399               3                                                                                 See number                                                                           Min 113mm
    See number
                      2400-3099               4           Min 71mm Min 100mm                                Min 91mm              of panels        6             300mm               58mm              9mm           Max 156mm
    of panels by                                                              310mm               500mm                        by door height
                      3100-3649               5           Max 231mm Max 200mm                               Max 151mm
    door height
                      3650-4249               6
                      4250-5000               7

                                                   Panel Width = Daylight Width + 42.5mm
                                                           Daylight Width (DW)
                                                                                                                                                                         H

                                                                                                                                         C                                       X
                                                                                                                                                                                                                 Y
H    X                                                                                                                                                                                            Z



       C                                                                                                                                                            SIDE VIEW

                                                      S        FRONT VIEW
                            G
             J



                            ELLIPSE DOOR - PANEL DETAILS
                                                                                                                                                 NUMBER OF PANELS BY
     (H) PANEL        (DW) DAYLIGHT   NUMBER OF            (J) END      (S) LAND     (X) ELLIPSE (G) ELLIPSE (C) BOTTOM
      HEIGHT            WIDTH mm       ELLIPSES            SPACING      SPACING        HEIGHT      WIDTH       SPACING                              DOOR HEIGHT
                      1800-2199                5                                                                                                     DOOR             NUMBER            PANEL
                      2200-2599                6                                                                                                  HEIGHT (mm)        OF PANELS       HEIGHT (mm)
    See number        2600-2999                7
    of panels by                                          Min 121mm                                         Min 113mm                                  3000              6                  483
                      3000-3399               8                          400mm        300mm       33mm
    door height                                           Max 321mm                                         Max 156mm                                  2800              5                  545
                      3400-3799                9                                                                                                       2650              5                  514
                      3800-4199               10                                                                                                       2500              5                  483
                      4200-4599               11                                                                                                       2375              5                  458
                      4600-5000               12                                                                                                       2250              4                  545
                                                                                                                                                       2125              4                  514
                                                                                                                                                       2000              4                  483
                                                   Panel Width = Daylight Width + 42.5mm
                                                                                                                                                       1900              4                  458
                                                           Daylight Width (DW)




H    X


       C

                                          G                    FRONT VIEW
                           S
                 J




                                                                                                                          29
                                OPERATING

                                SPECIFICATIONS
This information is given for guidance purposes only. P C Henderson reserve the right to make changes to door specifications without prior notice.


              DOORS WITH OPTIMIZER GEAR                                                                                                  DOORS WITH TRACKED GEAR
                                                                              1981mm (6'6") 2134mm (7'0")                                                       1981mm (6'6") 2134mm (7'0")
                                                                                high door     high door                                                           high door     high door
A : Kick out                                                                       940mm          1070mm          A : Kick out                                         944mm            998mm
B : Depth into garage                                                             1702mm          1702mm          B : Depth into garage                                1743mm          1920mm
C : Door kick out when fully open                                                  290mm           440mm          C : Door kick out when fully open                    138mm            114mm
D : Kick up                                                                        39mm            39mm           D : Kick up                                          11mm             10mm
E : Maximum drive through height                                                  1886mm          2038mm          E : Maximum drive through height                     1801mm          1954mm
F : Minimum opening width                                                         Door opening width -92mm        F : Minimum opening width                        Door opening width -88mm
G : Maximum opening width                                                         Door opening width -30mm        G : Maximum opening width                      Single door opening width -45mm
H : Height to which maximum                                                        983mm          1135mm                                                      Double door opening width -124mm
    opening width available                                                                                       H : Height to which maximum                          982mm           1058mm
                                                                                                                      opening width available
  KICK UP




                              A. KICK OUT                                     B
     D




                                                            C

                                                                                                                                           A. KICK OUT             B
                                                                                                                   KICK UP




                                                                                                                                                         C
                                                                                                                      D
  MAXIMUM PASS HEIGHT




                                                                                                                   MAXIMUM PASS HEIGHT
          E




                                                                                                                           E




                        NOTE:
                        For framed doors the kick
                        out when fully open (C)
                        increases to 410mm for
                        1981mm high doors. 560mm
                        for 2134mm high doors.




                                                                                     DOORS WITH CANOPY GEAR
                                      KICK UP




                                                                A. KICK OUT           B
                                         D




                                                                                                                                                             1981mm (6'6") 2134mm (7'0")
                                                                                                                                                               high door     high door
                                                                                                             A : Kick out                                       583mm              735mm
                                                                                                             B : Depth into garage                              1300mm             1300mm
                                      MAXIMUM PASS HEIGHT




                                                                                                             C : Door kick out when fully open               See A: kick out    See A: kick out
                                                                                                             D : Kick up                                         66mm               66mm
                                              E




                                                                                                             E : Maximum drive through height                   1826mm             1900mm

                                                                                                             Note: Minimum opening width for canopy doors is door opening width -50mm.




                                                                                                             30
PRODUCT GUARANTEE INFORMATION
1. GARAGE DOORS AND REMOTE CONTROL SYSTEMS                                                                     4. During the period of this guarantee the product must be subject to regular inspection for
                                                                                                               general wear and tear as well as correct operation by a competent person such as a trained garage
Garage doors and remote control systems are warranted for a period of two years from the date of               door installer. Please note that repairs made by a non-competent person will invalidate this
installation (see General Conditions 2) against defective manufacture for both materials and                   warranty.
workmanship, subject to the General Conditions stated below.                                                   5. Subject to these conditions Henderson will repair or replace the product or components at its
If the product has a Plastisol steel outer surface, that surface is warranted for a total period of ten        discretion. Any replaced product or component will become the property of P C Henderson Ltd.
years as standard, subject to the General Conditions stated below.                                             6. The maximum liability under this warranty shall be the purchase price, including Value Added
In the event that warranty service is required, you should immediately contact the retailer from               Tax, prevailing when the product was purchased. It does not cover consequential damage, nor does
whom the product was purchased.                                                                                it cover damage arising from incorrect handling, storage, installation or use, and impact or
                                                                                                               mechanical damage caused on or after delivery.
GENERAL CONDITIONS                                                                                             7. Corrosion, discolouration and other effects arising from elements within the building or from
1. The product must be used solely for the purpose for which it was designed and must not be                   abnormal pollution or contact with bird droppings or aggressive fumes, chemicals or other such like
modified in any way without prior written permission.                                                          environments are also excluded.
2. All claims under this guarantee must be made as soon as possible through the retailer or                    The guarantee under this warranty does not cover wear and tear on either the product or its
supplier from whom the goods were purchased and must be accompanied by an invoice or other                     component parts
recognised commercial document showing the date at which the guarantee commenced. The date of                  8. It is a fundamental condition of this guarantee that the product has been installed,
installation will normally be taken as the date of purchase except where a door is part of a newly             maintained and serviced correctly and is used solely for the purpose for which it was designed.
built property where the guarantee will commence from the date of first occupation provided the                Incorrect installation, maintenance and service will invalidate this warranty, as will the use of
delay between installation and occupation is of a reasonable duration.                                         spares not supplied by Henderson. The ‘caring for your garage door’ instructions are supplied with
3. All Henderson garage doors and associated products must have been installed maintained and                  the door.
serviced in accordance with the user care and maintenance instructions and installation instructions           9. Any claim made under this guarantee relating to a garage door must be accompanied by the
provided. In particular, all pivot points, bearings, springs and rollers (not tracks) on doors should          information shown on the information label that is normally attached to the door. This information
be oiled regularly and at least every six months. Certain Henderson steel and timber doors are                 will be needed when making a claim.
supplied in a "primed" state. These doors must be "finished" as stated in the ‘caring for your garage          10. Henderson products are sold subject to its Standard Terms and Conditions of Sale. This
door’ instructions immediately after installation. Because of the wide range of such paints and                guarantee shall only apply to goods sold against these Conditions and after 1st May 2002.
finishes that are available, this warranty does not apply to any finish applied after shipment. In
addition all doors should have their surfaces maintained and/or cleaned in accordance with these               All guarantees only apply to products, components and parts supplied
instructions at regular intervals and must have adequate air circulation and drainage to allow                 by this company.
rainwater to clear.


CARING FOR YOUR GARAGE DOOR
INSTALLATION                                                                                                   Before applying the paint ensure the surface of the door has been washed down using a mild
The instructions for installing this Henderson door are contained in the fittings pack supplied                solution of water and non-abrasive detergent, (such as washing up liquid). Then thoroughly
with the door and should be retained. It is recommended that this door is installed by a                       wash the door with warm water a number of times removing any evidence of the detergent.
competent person such as a trained garage door installer and that the installation instructions                Check the paint to be used on a small test area on the rear face before painting the whole door.
are read and understood before installation starts.                                                            The final door coating is not covered by the Henderson Guarantee. Fully Factory Finished doors
                                                                                                               (one piece, roller and sectional) should require no further painting. To help preserve the
OPERATING THE DOOR MANUALLY                                                                                    appearance of the door periodically wash with warm water.
A garage door offers a large surface area and can be affected by windy and blustery conditions.
For this reason, a manually operated one piece garage door should always be "parked" in a fully                GRP GARAGE DOORS
open or fully closed position. In the fully closed position, the door should be securely latched.              Gloss white GRP one-piece doors are supplied in a fully finished condition and require no further
When opened or closed, the door handle and/or leading edge of the door must be controlled                      painting or treatment. To help preserve the appearance it is recommended that the door is
throughout the opening or closing cycle until it is totally "parked". People, pets and objects                 periodically washed down with warm water and a non-abrasive detergent. To help preserve the
must be kept out of the way when the door is in motion. Your Henderson garage door can be                      appearance of Timber effect GRP one-piece doors a periodic dust down with a soft bristle brush
automated to open and close at the press of a button using a Henderson garage door operator.                   followed by a wash down with warm water is recommended.
Your retailer will be pleased to supply you with details. An automated garage door should be
operated as shown in the instructions supplied with the automatic operator.                                    TIMBER GARAGE
                                                                                                               Timber is a natural product which will vary in colour and shade and expand and contract
GENERAL MAINTENANCE AND SERVICING OF ALL DOORS                                                                 dependent on the weather conditions, causing noticeable swelling and movement at some joints.
Your Henderson garage door will give you years of service if you follow the simple routines as                 This is a natural phenomenon. All Henderson Timber doors are manufactured using only
stated below:                                                                                                  replenishable sources.
Ensure that all pivot points, bearings, springs and rollers are oiled. DO NOT oil tracks. Ensure
that there is no debris or dirt on or around the door so that rain water can drain away easily                 SEALED TIMBER DOORS
and that normal air circulation will allow the door to dry in good weather. AT LEAST EVERY 3                   Sealed Timber doors are supplied treated with industrial Sikkens CETOL WP560 range of
MONTHS: check, and if necessary, oil all pivot points, bearings, springs and rollers. DO NOT oil               microporous, water repellent coatings. For maximum protection against rot, mildew and other
the track. EVERY YEAR: check the following: The fixings between the door, any door frame and                   moisture induced deterioration, it is important that Sealed Timber doors are immediately
the building are solid and secure. The door lifting gear and its fixing points to the door and                 treated both externally and internally after installation with a minimum of two finishing coats
frame or building are solid and secure. All pivot points, bearings, springs and rollers are oiled.             of microporous water repellent stain. The final door coating is not covered by the Henderson
All items which are subject to wear and tear are inspected, these would include springs and                    Guarantee.
spring attachments, cones and cables and occasionally other items depending on the door type.                  N.B. Sikkens CETOL WP560 industrial range are selected for their compatibility with water based
It may be necessary to adjust the spring tension. This adjustment requires knowledge and care                  and solvent based top coats, both of which are available in a wide variety of opaque and
(i.e. never adjust a spring already in tension or compression) and for this reason it is                       translucent decorative finishes.
recommended that the annual inspection is carried out by a competent person such as a trained
garage door installer who should check the door and its installation thoroughly and advise you                 FACTORY STAINED TIMBER DOORS
of any requirement for replacement parts or adjustments which are necessary.                                   Stained Mahogany Timber doors are supplied treated with Sikkens CETOL HLS and finished with
                                                                                                               Sikkens industrial range CETOL WF755 (845) Mahogany. Dark Oak doors are finished with
STEEL GARAGE DOORS & FRAMES                                                                                    Sikkens CETOL Filter 7 (009) Dark Oak. For lasting protection of Sealed Timber doors, apply a
If your steel door is supplied in a factory primed finish, it will require painting with a good                single coat of Sikkens CETOL Filter 7 of applicable colour or the equivalent every 3-4 years in
quality semi-gloss or matt exterior household paint and appropriate undercoat as soon as                       accordance with the manufacturer's instructions.
possible after installation. The primer coat is applied as a base coat only. Any marks or scratches            A solid brass handle and fascia are supplied with timber doors. Over time the lacquer coat will
on the primer coat should be rubbed down and painted as part of the finishing process.                         wear through use and exposure to the elements.